• Title/Summary/Keyword: 2D/3D simultaneous

Search Result 283, Processing Time 0.025 seconds

The Experimental Study on the Direct Synthesis of DME (Dimethyl Ether) in the Fixed Bed Reactor. (고정층 반응기에서 DME 직접합성에 관한 실험 연구)

  • Choi, Chang Woo;Cho, Wonihl;Ju, Woo-Sung;Lee, Seung-Ho;Baek, YoungSoon;Row, Kyung Ho
    • Journal of Hydrogen and New Energy
    • /
    • v.15 no.4
    • /
    • pp.283-290
    • /
    • 2004
  • The single-step process for conversion of syngas to DME give higher conversion than the syngas-to-methanol process. This arises because of a synergy among the three simultaneous reaction, methanol synthesis, methanol dehydration and water gas shift reaction, in the process. we would find the optimal condition of the process which these advantages. The optimal condition of DME synthesis reaction over a commercial $Cu/Zn/Al_2O_3$ catalyst and Hybrid catalyst in a fixed bed reactor. The syngas-to-dimethyl ether conversion was examined on various reaction condition (Temperature 473~553K, $H_2/CO$ ratio 1~3, Pressure 30'50atm, GHSV 1000~4000).

Initial Nutritional Status and Clinical Outcomes in Patients With Deep Neck Infection

  • Park, Marn Joon;Kim, Ji Won;Kim, Yonghan;Lee, Yoon Se;Roh, Jong-Lyel;Choi, Seung-Ho;Kim, Sang Yoon;Nam, Soon Yuhl
    • Clinical and Experimental Otorhinolaryngology
    • /
    • v.11 no.4
    • /
    • pp.293-300
    • /
    • 2018
  • Objectives. The current study aims to determine the correlation between nutritional status upon presentation and disease severity, as well as treatment and survival outcomes. Methods. Patients who were diagnosed with deep neck infection, underwent at least one surgical drainage/debridement, and had more than 1 week of hospitalization at a tertiary medical center from 2007 to 2015 were retrospectively included. Thereafter, initial serum albumin, C-reactive protein (CRP), and body mass index (BMI) were reviewed. Results. A total of 135 patients were included in the final analysis. Accordingly, the proportion of patients with simultaneous mediastinitis (21.0%), necrotizing fasciitis (12.9%), disease extent >1 cervical level (72.6%), mean CRP (22.4 mg/dL), mean length of hospitalization (25.0 days), and mean 1-week follow-up CRP (7.2 mg/dL) was significantly higher in the hypoalbuminemia group (initial serum albumin <3.0 g/dL) than in the normoalbuminemia group (all P<0.05). No significant correlations had been observed according to BMI status. After adjusting for age and Charlson comorbidity index, odds ratios for the following outcomes were calculated in patients initially presenting with hypoalbuminemia: simultaneous mediastinitis (3.07), necrotizing fasciitis (7.89), disease extent >1 cervical level (2.12), initial serum CRP over 20 mg/dL (3.79), hospitalization of more than 14 days (4.10), 1-week follow-up CRP over 5 mg/dL (3.78), and increased duration for an over 50% decrease in initial CRP (2.70) (all P<0.05). Although intravascular albumin replenishment decreased the proportion of patients with hypoalbuminemia after 2 weeks (P<0.05), it did not significantly predict better treatment outcomes. Conclusion. Among the markers reflecting an individual's nutritional state, an initial serum albumin of less than 3.0 g/dL was an independent serologic marker predicting increased disease severity and complications in patients with deep neck infection.

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) Method and Artery-Vein Color Mapping in 0.3T MRI System (0.3T MRI 시스템에서의 동.정맥 동시 획득을 위한 자기공명 혈류 영상 기법(SAAV)과 동.정맥 color mapping)

  • 조종운;조지연;서성만;은충기;문치웅
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.275-280
    • /
    • 2003
  • The method of simultaneous data acquisition of arteries and veins(SAAV) was suggested to obtain MR angiography of arteries and veins at 0.3T low filed MRI system (Magfinder, AlLab. Korea). Two separated artery- and vein-images were put together using AVCM(Artery-Vein Color Mapping) algorithm and presented in the same image. In this study, artery- and vein-separated angiograms of volunteer's neck were obtained. Two dimensioal blood-enhanced images wre sequentially obtained using SAAV pulse sequence based on time-of-flight(TOF) method with flow compensation. Imaging parameters were TR/TE=70/12msec. FOV=230mm, slice thickness = 3mm, flip angle=90$^{\circ}$, matrix size=256${\times}$256${\times}$64mm. TSat TH/SPA=15/20mm, Ts_v=10msec and Ts_a=40ms. 3D MRA images were reconstructed using the maximum intensity projection(MIP) and the artery-vein color mapping(AVCM) algorithm. This study showed good possibility of clinical applications of MRA in 0.3T which provides valuable diagnostic information of clinical vascular diseases.

The Effect of N2 Dilution on the Flame Stabilization in a Non-Premixed Turbulent H2 Jet with Coaxial Air (질소 희석이 수소 난류확산화염의 화염안정성에 미치는 영향)

  • Oh, Jeong-Seog;Yoon, Young-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.477-485
    • /
    • 2009
  • The study of nitrogen dilution effect on the flame stability was experimentally investigated in a non-premixed turbulent lifted hydrogen jet with coaxial air. Hydrogen gas was used as a fuel and coaxial air was used to make flame liftoff. Each of hydrogen and air were injected through axisymetric inner and outer nozzles ($d_F=3.65\;mm$ and $d_A=14.1\;mm$). And both fuel jet and coaxial air velocity were fixed as $u_F=200\;m/s$ and $u_A=16\;m/s$, while the mole fraction of nitrogen diluents gas was varied from 0.0 to 0.2 with 0.1 step. For the analysis of flame structure and the flame stabilization mechanism, the simultaneous measurement of PIV/OH PLIF laser diagnostics had been performed. The stabilization point was selected in the most upstream region of the flame base and defined as the point where the turbulent flame propagation velocity was equal to the axial component of local flow velocity. We found that the turbulent flame propagation velocity increased with the decrease of nitrogen mole fraction. We concluded that the turbulent flame propagation velocity was expressed as a function of turbulent intensity and axial strain rate, even though nitrogen diluents mole fraction was changed.

Simultaneous Quantitative Analysis of Flavonoids Isolated from the Leaves of Diospyros kaki (감나무 잎으로부터 분리된 플라보노이드의 동시 정량분석)

  • Kim, Ga-Ram;Kim, Eun-Nam;Jeong, Gil-Saeng
    • Korean Journal of Pharmacognosy
    • /
    • v.51 no.2
    • /
    • pp.139-145
    • /
    • 2020
  • The leaves of Diospyros kaki Thunb. were used to treat heart disease and hypotension in traditionally East Asia. The purpose of this study is to simultaneously quantitiative analyze the content of flavonoids in leaves of D. kaki. The isolated flavonoids from the leaves of D. kaki, and the structure of the isolated flavonoids were analyzed based on 1H and 13C NMR spectrum compared to literature data. Simultaneous quantitative analysis of the isolated flavonoids was validated using high performance liquid chromatography (HPLC). Results showed that the calibration curves of the flavonoid compounds were confirmed that they have a large linearity with a correlation coefficient (R2) of 0.99. In the intra-day and inter-day analysis, accuracy and precision of five compounds were measured that accuracy was 94.39 to 114.47% and precision was less than 3.00%. Content analysis showed hyperoside (1.30 ± 0.09%), astragalin (0.81 ± 0.06%), trifoline (1.58 ± 0.07%), quercetin (0.13 ± 0.02%) and kaempferol (1.33 ± 0.25%).

An implementation of 2D/3D Complex Optical System and its Algorithm for High Speed, Precision Solder Paste Vision Inspection (솔더 페이스트의 고속, 고정밀 검사를 위한 이차원/삼차원 복합 광학계 및 알고리즘 구현)

  • 조상현;최흥문
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.139-146
    • /
    • 2004
  • A 2D/3D complex optical system and its vision inspection algerian is proposed and implemented as a single probe system for high speed, precise vision inspection of the solder pastes. One pass un length labeling algorithm is proposed instead of the conventional two pass labeling algorithm for fast extraction of the 2D shape of the solder paste image from the recent line-scan camera as well as the conventional area-scan camera, and the optical probe path generation is also proposed for the efficient 2D/3D inspection. The Moire interferometry-based phase shift algerian and its optical system implementation is introduced, instead of the conventional laser slit-beam method, for the high precision 3D vision inspection. All of the time-critical algorithms are MMX SIMD parallel-coded for further speedup. The proposed system is implemented for simultaneous 2D/3D inspection of 10mm${\times}$10mm FOV with resolutions of 10 ${\mu}{\textrm}{m}$ for both x, y axis and 1 ${\mu}{\textrm}{m}$ for z axis. Experiments conducted on several nBs show that the 2D/3D inspection of an FOV, excluding an image capturing, results in high speed of about 0.011sec/0.01sec, respectively, after image capturing, with $\pm$1${\mu}{\textrm}{m}$ height accuracy.

A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration field with Stereo-PIV/PLIF Technique (Stereo-PIV/LIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구)

  • Min, Young-Uk;Kim, Yun-Gi;Kim, Kyung-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.365-370
    • /
    • 2004
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereo Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K${\times}$2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent flow around Rushton turbine were identified by the calculation of synchronized data of the velocity field and concentration field.

Mechanical Properties and Fabrication of WC-Co Hard Materials by Rapid Sintering Method for Friction Stir Welding Tool Application (급속소결 방법을 이용한 마찰교반 접합 툴용 WC-Co 소결체 제조 및 특성 평가)

  • Park, Hyun-Kuk;Youn, Hee-Jun;Ryu, Jung-Han;Jang, Jun-Ho;Shon, In-Jin;Oh, Ik-Hyun
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.92-97
    • /
    • 2012
  • Using the pulsed current activated sintering method, the WC-10wt.% Co materials were densified using a WC and Co powder. The WC-Co almost completely dense with a relative density of up to 99.5 % after the simultaneous application of a pressure of 60 MPa and an electric current for 3 minutes almost without any significant change in the grain size. The average grain size of about $0.3{\mu}m$. The hardness and fracture toughness at $1000^{\circ}C$ were about $2200kg/mm^2$ and $9.8MPa.m^{1/2}$, respectively.

Comparative Study on the Interface and Interaction for Manipulating 3D Virtual Objects in a Virtual Reality Environment (가상현실 환경에서 3D 가상객체 조작을 위한 인터페이스와 인터랙션 비교 연구)

  • Park, Kyeong-Beom;Lee, Jae Yeol
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.1
    • /
    • pp.20-30
    • /
    • 2016
  • Recently immersive virtual reality (VR) becomes popular due to the advanced development of I/O interfaces and related SWs for effectively constructing VR environments. In particular, natural and intuitive manipulation of 3D virtual objects is still considered as one of the most important user interaction issues. This paper presents a comparative study on the manipulation and interaction of 3D virtual objects using different interfaces and interactions in three VR environments. The comparative study includes both quantitative and qualitative aspects. Three different experimental setups are 1) typical desktop-based VR using mouse and keyboard, 2) hand gesture-supported desktop VR using a Leap Motion sensor, and 3) immersive VR by wearing an HMD with hand gesture interaction using a Leap Motion sensor. In the desktop VR with hand gestures, the Leap Motion sensor is put on the desk. On the other hand, in the immersive VR, the sensor is mounted on the HMD so that the user can manipulate virtual objects in the front of the HMD. For the quantitative analysis, a task completion time and success rate were measured. Experimental tasks require complex 3D transformation such as simultaneous 3D translation and 3D rotation. For the qualitative analysis, various factors relating to user experience such as ease of use, natural interaction, and stressfulness were evaluated. The qualitative and quantitative analyses show that the immersive VR with the natural hand gesture provides more intuitive and natural interactions, supports fast and effective performance on task completion, but causes stressful condition.

A Design of Ultra Wide-Band Feedforward Amplifier Using Equal Group-Delayed Signal Canceller (동일 군속도 지연 신호 상쇄기를 이용한 광대역 Feedforward증폭기 설계)

  • Jeong Yong-Chae;Ahn Dal;Kim Hong-Gi;Kim Chul-Dong;Chang Ik-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.825-834
    • /
    • 2005
  • In this paper, a new signal canceller that input signals are equally group-delayed and cancelled each other is proposed and feedforward linearizing power amplifier that adopt the proposed signal cancellers is fabricated. Although the conventional signal canceller can't matches the phase and the group delay time of input signals simultaneously, the proposed signal canceller matches those simultaneously. Simultaneous matching of the phase and the group delay time can makes wideband signal cancellation. The main signal cancellation loop of the fabricated feedforward amplifier with the proposed signal cancellers cancel input signal more than 26.3 dB and the intermodulation distortion signal cancellation loop cancel more than 15.2 dB for 200 MHz bandwidth. And the proposed feedforward power amplifier improves C/I ratio by 20.8 dB with two tones at 2,115 MHz, 2,165 MHz, respectively.