• Title/Summary/Keyword: 22kV class

Search Result 93, Processing Time 0.031 seconds

A STUDY ON THE SHEAR BOND STRENGTHS AND MICROLEAKAGES OF THREE BONDING AGENTS ON DENTIN (상아질 접착제의 전단결합강도와 미세누출에 관한 연구)

  • Kim, Jeong-Ho;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.680-692
    • /
    • 1997
  • New bonding agent systems have been supplied which operators can simply apply to conditioned tooth surfaces. The purpose of this study was to evaluate the shear bond strengths and the microleakages of three bonding agents and composite resins to dentin. Seventy-five extracted human maxillary and mandibular molar teeth were used in this study. For the shear bond strength test, the entire occlusal dentin surfaces of thirty teeth were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A). For the microleakage test, Class V cavities were prepared in the buccal surfaces of fourtyfive teeth. They were randomly assigned into 3 groups according to dentin bonding agents ($Scotchbond^{TM}$ Multi-Purpose plus, ONE-$STEP^{TM}$ and Prime & $Bond^{TM}$)and composite resins (Z-100, $Aelitefil^{TM}$ and TPH $Spectrum^{TM}$) to be used. Bonding agents and composite resins were bonded to exposed dentin surfaces of the tooth crown and to Class V cavities on the buccal surfaces respectively according to manufacturer's directions. The shear bond strengths were measured by universal testing machine($U^{TM}$ AGS-100, Japan). In addition, the degree of micro leakage at the occlusal and gingival margin was examined by 2 % methylene blue and stereomicroscope(Olymous SZH 10, Japan). The results were as follows: 1. The shear bond strength to dentin was the highest value in SBMP-Plus group($16.68{\pm}7.38$ MPa) and the lowest value in Prime & Bond group($11.61{\pm}5.82$ MPa), but there was no significant difference of shear bond strength among three groups. 2. The degree of microleakage at both occlusal and gingival margin was showed the lowest in SBMP-Plus group and the highest in ONE-STEP group. 3. At both occlusal and gingival margin, there was significant difference of microleakage between SBMP-Plus and ONE-STEP/ Prime & Bond groups(p<0.05), but no significant difference of microleakage between ONE-STEP and Prime & Bond group(p>0.05).

  • PDF

Introduction of KEPCO's distribution class SFCL fabricated for verification test (실증시험용 배전급 초전도 한류기의 특성 평가 및 운전 시험)

  • Yim, Seong-Woo;Park, Chung-Ryul;Yu, Seung-Duck;Kim, Hye-Rim;Hyun, Ok-Bae;Park, Kwon-Bae;Sim, Jung-Wook;Lee, Kyoung-Ho;Oh, Ill-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.294_295
    • /
    • 2009
  • Superconducting fault current limiter (SFCL) is an power device of a novel concept. While SFCLs generate no ohmic loss during the operation carrying normal currents, they can limit fault currents very fast making large impedance by their quench characteristics. In 2006, KEPCO has developed a distribution class hybrid type SFCL by a collaborative research project with LS industrial systems. The SFCL has merits in practical and economical points of view. In the SFCL, the superconductor just plays a role of a fault detector and the current limiting is completed by the other current limiting element made of normal metals throu호 the line commutation. As a result, the required amounts of superconductors can be reduced considerably. Consequently, the hybrid SFCL can be fabricated with small size and cost, maintaining perfect current limiting performance. Currently, KEPCO is carrying out a research project at Gochang power test center for the purpose of the verification test of the 22.9 kV/ 630 A class SFCL for the practical application in real grid. Through the project, a long term operational test and fault current test will be done. In this paper, the back ground of development and installation of the SFCL will be explained and the operation plan of the SFCL for the verification test is also introduced.

  • PDF

The Properties of Breakdown and Test for Resistance to Cracking of Power Cable for PL Countermeasure (PL법 대응을 위한 전력케이블의 열 충격 및 절연파괴 특성)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.349-352
    • /
    • 2007
  • It is impossible to database(DB) the patterns of cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to nicking of cable below the 22.9kV class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). First of all, set the cable in the thermal stress instrument, temperature changed from -20 degree to 120 degree. After thermal stress, we observed a surface crack of cable through microscope and carried out AC withstand voltage test.

  • PDF

Development of Power Cable Diagnostic and Insulation Measurement System (전력케이블 열화진단용 측정장치 개발)

  • Yi, Dong-Young;Kwon, Hyuk-Il;Chung, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2126-2129
    • /
    • 1999
  • We have developed the automatic diagnostic system for power cable insulation using DC voltage decay method in this work. Test condition, test method and diagnose criteria of our diagnostic system are adjustable to a class of power cables such as 3.3, 6.6, 11 and 22kV power cables. We have also developed measurement and diagnostic programs for win95 which is suitable for the management of database such as test condition, diagnose results and cable operation data.

  • PDF

Characteristics of Joint High Temperature Superconducting tape (High Temperature Superconducting tape(Bi-2223)의 접속시 통전특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Cho, Jeon-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.244-245
    • /
    • 2007
  • Specially, High Temperature Superconducting power-transmission cable(HTS cable), 3-phase 100m long, 22.9kV class HTS power transmission cable system have been developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. that is one of 21st century frontier project in Korea. This cable was installed in KEPCO(Go-chang) testing site. In case of manufacturing HTS cable, superconducting joint is very important because they need very long tapes. Therefore, this paper gives some investigation of AC Loss in joined HTS tape by using several joint methods. Finally, this paper was shown background data for the form of HTS cable joint.

  • PDF

A Economic feasibility of HTS cable by estimating the Life-Cycle cost (Life-cycle 비용 산정을 통한 초전도케이블 경제성 검토)

  • Kim Jong Yul;Lee Seong Ryul;Yoon Jae Young
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.424-426
    • /
    • 2004
  • As power demand increases gradually, the call for underground transmission system increases. But it is very difficult and high in cost to construct new ducts and/or tunnels for power cables in metropolitan areas. HTS (High Temperature Superconducting) cable has the several useful characteristics such as increased power density, stronger fields and/or reduced losses. Therefore HTS cable can allow more power to be moved in existing ducts, which means very large economical and environmental benefits. In these days, companies world-wide have conducted researches on HTS cable. A development project for a 22.9kV class HTS cable is proceeding at a research center and university in Korea. In this paper, we investigate the expected price of HTS cable to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional cable is calculated and based on this, the expected price of HTS cable is evaluated, which HTS cable is competitive against conventional cable.

  • PDF

A Study on Operation Method of Power Distribution System Integrated with Dispersed Generation System (분산형전원이 도입된 복합배전계통의 운용방안에 대한 고찰)

  • Kim, Jae-Eon;Jo, Seong-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.692-698
    • /
    • 1999
  • This paper analyzes the effect of DGS(Dispersed Generation System) on the voltage regulation of the traditional distribution system of which the voltage is controlled by the bank LDC(Line Drop Compensator). Through the simulation results for 22.9kV class distribution system with DGSs, some general relationships among the operating power factor and introduction limit of DGS, and the sending-end reference voltage determined by internal setting coefficients of the LDC are derived. Those relationships are that the introduction limit of DGS increases as the power factor of DGS goes from lagging to leading and also as the allowance of the sending-end reference voltage increases. From the relationships, a operation method of the power distribution system integrated with DGSs is proposed from the view point of the operating power factor of DGS and new voltage regulation method.

  • PDF

Suitability Grouping System of Paddy Soils for Multiple Cropping -Part II : Criteria of the Suitability Grouping (다모작(多毛作)을 위한 답토양(畓土壤) 적성등급(適性等級) 구분(區分) -제(第)2보(報) : 적성등급(適性等級) 구분기준(區分基準))

  • Jung, Yeun-Tae;Park, Eun-Ho;No, Yeong-Pal;Um, Ki-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.19 no.4
    • /
    • pp.283-289
    • /
    • 1986
  • To establish a suitability grouping system of paddy soils for multiple cropping of rice with other upland crops, the study was carried out after a few basic experiments. In succession to the results on basic experiment prior, the suitability system proposed and the results of application mentioned in this report were summarized as follows; 1. The factors of soil properties in the system were productivities represented by soil texture and drainage class, as well as salinity of surface and sub-soil pH of chemical properties were considered together with slope, warmth index, ground water table, parent materials etc. of soil physical or environmental conditions. The weights of the factors were combined with multiplicatively and additively so as the total marks of ideal soil to be 100. The system was composed with 5 suitability classes; over 91 mark is class I, under 60 mark class V, and each 10 point interval between classes. The limiting factors "P" (in the case that Physical properties or Productivity marks under 24), "S" (Surface slope less than 15) and "C" (Chemical condition below 15) etc. were appended up to two kinds to the classes except a part of soils in class I. 2. The areas where the warmth index exceed 110 in Yeongnam were 19% for class I, 22.7% for class II, 44.7% for class III, 11.5% for class IV, and 2.1% for class V. The rates in class I and II were slightly more than those of the whole country. 3. The points of each soil gained by the system had a positive correlation ($r=.922^{**}$) with the potential productivities.

  • PDF

High-Efficiency CMOS Power Amplifier Using Uneven Bias for Wireless LAN Application

  • Ryu, Namsik;Jung, Jae-Ho;Jeong, Yongchae
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.885-891
    • /
    • 2012
  • This paper proposes a high-efficiency power amplifier (PA) with uneven bias. The proposed amplifier consists of a driver amplifier, power stages of the main amplifier with class AB bias, and an auxiliary amplifier with class C bias. Unlike other CMOS PAs, the amplifier adopts a current-mode transformer-based combiner to reduce the output stage loss and size. As a result, the amplifier can improve the efficiency and reduce the quiescent current. The fully integrated CMOS PA is implemented using the commercial Taiwan Semiconductor Manufacturing Company 0.18-${\mu}m$ RF-CMOS process with a supply voltage of 3.3 V. The measured gain, $P_{1dB}$, and efficiency at $P_{1dB}$ are 29 dB, 28.1 dBm, and 37.9%, respectively. When the PA is tested with 54 Mbps of an 802.11g WLAN orthogonal frequency division multiplexing signal, a 25-dB error vector magnitude compliant output power of 22 dBm and a 21.5% efficiency can be obtained.

Cooling Performance Test of the KEPCO HTS Power Cable

  • Yang, H.S.;Kim, D.L.;Sohn, S.H.;Lim, J.H.;Choi, H.O.;Choi, Y.S.;Ryoo, H.S.;Hwang, S.D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.41-43
    • /
    • 2009
  • The HTS power cable system of 3-phase 100-m class has been tested at the KEPCO's Gochang power testing center in Korea during 8,000 hours or more for investigating long-term operating performance. The system is rated 22.9kV, 1250A and is cooled with sub cooled liquid nitrogen. Several cooling performance tests such as cooling capacity, heat load, AC loss, temperature stability and thermal cycle were performed at operating temperature of 66.4K and several different temperatures.