• Title/Summary/Keyword: 22kV class

Search Result 93, Processing Time 0.025 seconds

Analysis of Diagnosis and Very Low Frequency Experiment to Detect of Fault on 22.9kV Class Cable (22.9kV급 케이블 결함 검출을 위한 초저주파 실험 및 현장 진단 분석)

  • Kim, Young-Seok;Kim, Taek-Hee;Kim, Chong-Min;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1780-1785
    • /
    • 2016
  • This paper presents few case studies of state diagnosis of XLPE cables using very low frequency techniques. The power cables of 22.9kV which have installation fault were assessed using VLF technique in addition to other techniques like insulation resistance and DC voltage withstand test. From the experimental results, The dielectric loss($tan{\delta}$) values of degradation of the cable(joint, knife, needle) at $U_0$ were 5.839, 5.526 and 6.251, respectively and all values were "further study advised". VLF PD measurement was also found defective portion. These method was effective in defect to fault in the degradation of the cable. However, the breakdown did not occur in the degradation of the cable because of properties of XLPE insulation. Few case studies of using VLF $tan{\delta}$ diagnosis for fault are measured and analyzed. The $tan{\delta}$ values at $U_0$ were "further study advised" or "action required".

Design of Main Body and Edge Termination of 100 V Class Super-junction Trench MOSFET

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.565-569
    • /
    • 2018
  • For the conventional power MOSFET (metal-oxide semiconductor field-effect transistor) device structure, there exists a tradeoff relationship between specific on-state resistance (Ron,sp) and breakdown voltage (BV). In order to overcome this tradeoff, a super-junction (SJ) trench MOSFET (TMOSFET) structure with uniform or non-uniform doping concentration, which decreases linearly in the vertical direction from the N drift region at the bottom to the channel at the top, for an optimal design is suggested in this paper. The on-state resistance of $0.96m{\Omega}-cm2$ at the SJ TMOSFET is much less than that at the conventional power MOSFET under the same breakdown voltage of 100V. A design methodology for the edge termination is proposed to achieve the same breakdown voltage and on-state resistance as the main body of the super-junction TMOSFET by using of the SILVACO TCAD 2D device simulator, Atlas.

Optimization of the Large Scale Magnetic Pulse Compression System of 100 ns-order (100 ns급 대용량 자기펄스 압축시스템의 최적화)

  • 이용우;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.442-445
    • /
    • 2003
  • In this study, we developed the 40 J-class MPC(magnetic pulse compression) system for exciting excimer laser and investigated the optimal conditions of each stage of MPC circuit. This system consists of a DC power supply, a pulse transformer and four saturable inductors. The number of turns of saturable inductors at each stage of MPC circuit are 140, 25, 5, 1 and the optimal storage capacitance of each stage are 34 nF, 28.9 nF, 22.1 nF, respectively. In the improvement MPC system, we have obtained an output voltage of 43 kV, a current of 8.25 kA and a pulse duration of 360 ns. Also, the maximum pulse compression ratio of 77.7 and the current gain of 71.7 were obtained.

  • PDF

What was the vSim for nursing practice experience?

  • Kim, Jungae
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.3
    • /
    • pp.25-31
    • /
    • 2020
  • The study is a phenomenological analysis of the video simulation clinical practice experience recently conducted on nursing students due to the outbreak of corona 19 worldwide. A total of eight students participated in the vSim class who understood the purpose of the study and wanted to participate voluntarily. The data collection conducted a total of three interviews until no new data was available, and the collection period was from June 22, 2020 to July 10, 2020. The collected data were analyzed with the Giorgi's Phenomenological Analysis Method. As a result of the study, three components and 13 semantic units were derived. vSim was difficult for students, but it was an interesting experience that made them feel like nurses, and it was an experience in which they were immersed in learning rather than face-to-face classes, and their skills improved.

Real and Reactive power coordination control of Distributed Generation System for Distribution Voltage Regulation (배전계통 적정전압 유지를 위한 유효 무효전력 협조제어)

  • Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.153-155
    • /
    • 2000
  • This paper reveals some correlations between LDC voltage control method and the output of DGS, and also presents a method for determining the amounts of real, reactive Power of DGS for proper voltage regulation of power distribution system with LDC. Proposed method has been applied to a 22.9 kV class power distribution system, and those results show that the distribution system voltage profile is improved.

  • PDF

A Study on the Fire Properties of MOF Insulation Cover and Field Condition of 22.9kV Class Power Receiving System (22.9kV 수변전설비의 실태 및 계기용변성기 절연커버의 출화특성에 관한 연구)

  • Choi Chung-Seog;Kim Dong-Woo;Han Woon-Ki;Lee Ki-Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.56-60
    • /
    • 2005
  • We studied fire properties of MOF(Metering Out Fit) insulation cover and field condition of 22.9kV power receiving system. $49.5\%$ of formal equipments were installed indoors, whereas $40.8\%$ of informal equipments were installed as H-type. Insulation treatment was not done at a $22.4\%$ ratio of main line($27.7\%$ of transformer, $70.2\%$ of COS, $10.4\%$ of MOF). Fire pattern analysis showed that the fire started at the secondary part of OC wire. In the result of DTA(Differential Thermal Analysis), normal cover showed exothermic reactions at $310^{\circ}C,\;399^{\circ}C\;and\;510^{\circ}C$ (endothermic reactions at $382^{\circ}C$). Whereas damaged cover showed exothermic reactions at $412^{\circ}C$(endothermic reactions at $389^{\circ}C$). In the result of TGA(Thermo Gravimetric Analysis), the thermal weight change of normal cover was similar compared to damaged cover. In the result of FT-IR analysis, normal cover showed absorption peaks at $3,024cm^{-l},\;2,921cm^{-l},\;1,600cm^{-1},\;1,492cm^{-1},\;1,451cm^{-1},\;1,154cm^{-l},\;1,027cm^{-1},\;906cm^{-1}$. Whereas, in case of tracked cover, the absorption peaks that were shown in normal cover disappeared and different absorption peak was shown at $966cm^{-1}$.

Design of Termination Cryostat for HTS Power Cable (고온초전도 케이블 단말용 cryostat 설계)

  • 양형석;김승현;김동락;조승연;김도형;류희석;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.160-162
    • /
    • 2003
  • Termination cryostat for 22.9kV, 1.26kA-class HTS power cable has been designed. The cryostat consists of vacuum vessel, liquid nitrogen vessel, current lead and HTS power cable. The current lead and the HTS power cable are connected in liquid nitrogen vessel cooled by forced-circulation subcooled liquid nitrogen. The maximum total heat load of this cryostat is expected to be 150w. In this paper, the detailed design of the termination cryostat is mentioned.

  • PDF

Effect of Heat Input on the Mechanical Properties of SA508 class 3 Steel Weldments with Submerged Arc Welding (SA508 class 3 서브머지드 아크용접부의 기계적 성질에 미치는 입열량의 영향)

  • Seo Yun-seok;Koh Jin-Hyun;Kim Nam-Hoon;Oh Se-Yong;Choo Kee-Nam
    • Journal of Welding and Joining
    • /
    • v.22 no.5
    • /
    • pp.38-45
    • /
    • 2004
  • The present study is to investigate the effect of heat input on the microstructure, tensile properties and toughness of single-pass submerged arc bead-in-groove welds produced on SA508 class 3 steels. The heat input was varied in the range of 1.6, 3.2 and 5.0 kJ/mm. The toughness of weld metals was evaluated by using subsize Charpy V-notch specimens in the temperature range of -19$0^{\circ}C$ to 2$0^{\circ}C$. The weld microstructure and fractography were observed by optical and scanning electron microscopies, respectively. With increasing heat inputs, tensile strength and hardness of weld metals were decreased while elongation was increased. The poor notch toughness at 1.6 kJ/mm was attributed to the formation of ferrite with aligned second phase and banitic microstructure with high yield strength while that at 5.0 kJ/mm was due to the presence of grain boundary and polygonal ferrites. The microstructure of the intermediate energy input welds consisted of a high proportion of acicular ferrite with limited polygonal ferrites, which provide improved notch toughness.

Electrical Characteristics of Super Junction MOSFET According to Trench Etch Angle of P-pillar (P-pillar 식각 각도에 따른 Super Junction MOSFET의 전기적 특성 분석에 관한 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.8
    • /
    • pp.497-500
    • /
    • 2014
  • In this paper, we analyze electrical characteristics of n/p-pillar layer according to trench angle which is the most important characteristics of SJ MOSFET and core process. Because research target is 600 V class SJ MOSFET, so conclusively trench angle deduced 89.5 degree to implement the breakdown voltage 750 V with 30% margin rate. we found that on resistance is $22mohm{\cdot}cm^2$ and threshold voltage is 3.5 V. Moreover, depletion layer of electric field distribution also uniformly distributes.

Studies on the Estimation of Korean Pine(Pinus koraiensis) Stand Structure by Aerial Photographs (항공사진(航空寫眞)에 의한 잣나무 임분구조(林分構造)의 추정(推定)에 관한 연구(硏究))

  • Yun, Jong Wha;Cha, Du Song
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.4
    • /
    • pp.437-446
    • /
    • 1995
  • This study was carried out to estimate the Korean Pine stand structure such as coefficient of variation of mean DBH, number of trees and volume per ha by Weibull distribution for each age class from I to V, based on photo measurement and timber cursing in Kangwon National University Experimental Forests. The results were summarized as follows: 1) Coefficient of variation of mean DBH for each age class from I to V, which was obtained by converting DBH estimated from crown diameter by photo measurement into quadratic mean DBH, was estimated as 28.88%, 24.13%, 23.29%, 20.27%, and 18.79%, respectively. 2) Number of trees per ha of each age class by Weibull distribution was obtained as 2875, 2100, 1875, 800, and 325, respectively. 3) Volume per ha of each age class was estimated as $22.9m^3$, $66.8m^3$, $101.3m^3$, $209.6m^3$, and $266.8m^3$, respectively. 4) Therefore, aerial photographs will be helpful to estimate the stand structure effectively.

  • PDF