• 제목/요약/키워드: 20 kHz power system

검색결과 133건 처리시간 0.025초

Decomposition of NO$_2$ by SPCP

  • Kang, Hyun Choon;An, Hyung Whan;Lee, Han Seob;Hwang, Myung Whan;Woo, In Sung;Kang, An Soo
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.52-57
    • /
    • 2002
  • The Decomposition of NO$_2$ (nitrogen dioxide), one of the Hazardous Air Pollutant (HAP), was studied by utilizing the SPCP (Surface induced discharge Plasma Chemical Processing) reactor so as to obtain optimum process variables and maximum decomposition efficiencies. Experimental results showed that for the frequency of 10kHz, the highest deco position efficiency of 84.7% for NO$_2$ was observed at the power consumptions of 20W. The decomposition efficiency of $NO_2$ was found to be: 1) proportional to the residence times, and inversely proportional to the initial concentrations of $NO_2$; 2) the maximum when the electrode diameter was 3mm; 3) influenced by the electrode material, decreasing in the order of W>Cu>Al; and 4) proportional to the $CH_4$ content, due to which the highest efficiency of 98% was obtained with almost all the $NO_2$ removed.

10 Gbps Transimpedance Amplifier-Receiver for Optical Interconnects

  • Sangirov, Jamshid;Ukaegbu, Ikechi Augustine;Lee, Tae-Woo;Cho, Mu Hee;Park, Hyo-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.44-49
    • /
    • 2013
  • A transimpedance amplifier (TIA)-optical receiver (Rx) using two intersecting active feedback system with regulated-cascode (RGC) input stage has been designed and implemented for optical interconnects. The optical TIA-Rx chip is designed in a 0.13 ${\mu}m$ CMOS technology and works up to 10 Gbps data rate. The TIA-Rx chip core occupies an area of 0.051 $mm^2$ with power consumption of 16.9 mW at 1.3 V. The measured input-referred noise of optical TIA-Rx is 20 pA/${\surd}$Hz with a 3-dB bandwidth of 6.9 GHz. The proposed TIA-Rx achieved a high gain-bandwidth product per DC power figure of merit of 408 $GHz{\Omega}/mW$.

Yohimbine과 Atipamezole이 Xylazine-Ketamine 병용 마취견의 뇌파에 미치는 영향 (Effects of Yohimbine and Atipamezole in Dogs Anesthetized with Xylazine-Ketamine Combination on EEG)

  • 장환수;장광호;이만기;장인호
    • 한국임상수의학회지
    • /
    • 제19권2호
    • /
    • pp.174-185
    • /
    • 2002
  • We investigated the effects of yohimbine and atipamezole in dogs anesthetized with xylazine-ketamine combination on electroencephalography (EEG) . Experiment groups were divided into three according to antagonists . Saline (1 ml) was used as an antagonist in group C, yohimbine (0.1 mg/kg) in group Y and atipamezole (50 ug/kg) in group A. Each group consisted of 5 dogs. Glycopyrrolate was injected 15 minutes prior to xylazine injection. Xylazine (1.1 mg/kg, IM) and ketamime (10 mg/kg, IV) were injected with the interval of 10 minutes. After 15 minutes, antagonists were administered intravenously. For EEG measurements, a recording electrode was positioned at Cz, which was applied to International 10-20 system. Heart rates, body temperature, respiratory rates, arterial blood pressure, $PaO_2$$PaCO_2$$PaCO_2$ at S4 in group Y was significantly decreased(p<0.05). Changes of electrolytes were not significant, except value of $Cl^-$ at S3 in group A. Mean head-up time (the time dogs showing head-up movement after antagonist injection, minutes) was $38.23^{\circ}$ae6.46 in group C, 2.54 $\pm$ 0.93 in group Y and 2.12$\pm$ 1.32 in group A. Mean sternal recumbent time (the time dogs showing sternal recumbency after antagonist injection, minutes) was 45.93$\pm$ 10.27 in group C, 11.91 $\pm$ 7.19 in group Y and 9.88$\pm$ 3.38 in group A. Mean walking time (minutes) was 53.49$\pm$ 9.21 in group C, 22.10$\pm$ 11.10 in group Y and 18.48$\pm$ 4.39 in group A. In group Y all dogs showed excitation and muscle rigidity in emergence. In group A, two dogs were also showed excitation and muscle rigidity, but were weaker than those of group Y.

초음파 폴리싱 시스템의 개발 및 특성 (The Polishing Characteristics and Development of Ultrasonic Polishing System)

  • 문홍현;박병규;김성청;이찬호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1014-1020
    • /
    • 2003
  • We have developed the ultrasonic polishing system to get super finishing that consist of machine part that can rotate and travel the main shaft with power 1.5kW, ultrasonic generator with frequency 20kHz. By using this system we were investigated the characteristics of ultrasonic polishing and deduced the major facters which affect the surface roughness by the experimental plans for three different materials such as ceramic, glass, and wafer, and so could be obtained following results. We could be obtained the excellent surface for hard-to-difficult cutting materials. The rotating speed could be found to be major factor influencing the surface roughness. In the case of ceramic and wafer, we were able to obtain good surface roughness when the feed rate and ultrasonic output is higher. In the case of glass, the surface roughness becames worse when ultrasonic output is higher because of increasing of load affacting on the particles in slurry.

  • PDF

A DSP Implementation of Subband Sound Localization System

  • Park, Kyusik
    • The Journal of the Acoustical Society of Korea
    • /
    • 제20권4E호
    • /
    • pp.52-60
    • /
    • 2001
  • This paper describes real time implementation of subband sound localization system on a floating-point DSP TI TMS320C31. The system determines two dimensional location of an active speaker in a closed room environment with real noise presents. The system consists of an two microphone array connected to TI DSP hosted by PC. The implemented sound localization algorithm is Subband CPSP which is an improved version of traditional CPSP (Cross-Power Spectrum Phase) method. The algorithm first split the input speech signal into arbitrary number of subband using subband filter banks and calculate the CPSP in each subband. It then averages out the CPSP results on each subband and compute a source location estimate. The proposed algorithm has an advantage over CPSP such that it minimize the overall estimation error in source location by limiting the specific band dominant noise to that subband. As a result, it makes possible to set up a robust real time sound localization system. For real time simulation, the input speech is captured using two microphone and digitized by the DSP at sampling rate 8192 hz, 16 bit/sample. The source location is then estimated at once per second to satisfy real-time computational constraints. The performance of the proposed system is confirmed by several real time simulation of the speech at a distance of 1m, 2m, 3m with various speech source locations and it shows over 5% accuracy improvement for the source location estimation.

  • PDF

High Efficient Inductive Power Supply System Implemented for On Line Electric Vehicles

  • 허진;박은하;정구호;임춘택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.105-110
    • /
    • 2009
  • The On Line Electric Vehicles(OLEV) that can pick up inductive power from underground coils on driving with high efficiency have been developed this year, and is now proposed in this paper. The IPS(Inductive Power Supply) system consists of power supply inverters, power supply rails, pick up modules, and a regulator. There are 3 generations of IPS have been developed so far, and the $4^{th}$ generation IPS is being developed. The $1^{st}$ generation has been demonstrated this Feb. 27, which is equipped with mechanically auto tracking pick-up module with 1cm air gap, and showed 80% power efficiency. The $2^{nd}$ generation IPS applied to an 120kW (average)/240kW(peak) motor powered electric bus has 17cm air gap with 72% power efficiency. For the $2^{nd}$ generation IPS, the Power supply inverter has 440V, 3phase input and 200A @ 20kHz output. The test power supply rail of 240m long is segmented by 60m each, where newly developed core structure and power cable are constructed under the road covered with asphalt of 5cm thickness. The pick-up modules which consist of core, winding wire, and rectifiers are fixed to the bottom of the bus which can carry more than 40 passengers and can pick up max. 60kW. To remove parasitic component and to transfer maximum power between them resonant circuit topology is applied to the primary and secondary sides. The EMF level is below 62.5mG at 1.75m from the center of the road to meet the regulation. Several effective ways of reducing EMF levels have been developed. In addition, effective ways to solve problems related high frequency power cables buried in ground and it's proof from soil have been studied also. This development shows that the IPS system is capable of supplying enough power to the pick-up of OLEV and can reduce battery size, weight and cost, which means the IPS with OLEV is one of the best candidate for EV.

  • PDF

수산음향계측장치의 탐지범위에 대한 연구 (A Study on the Detection Range of Acoustic Instruments for Fisheries)

  • 박주삼
    • 수산해양기술연구
    • /
    • 제41권1호
    • /
    • pp.54-63
    • /
    • 2005
  • 어군탐지기, 계량어군탐지기, 바이오텔레메터리등 음향을 이용하여 해중의 어군의 정보를 탐색하는 수산음향계측장치의 탐지범위와 그 음향특성에 대해 검토, 분석할 결과를 요약하면 다음과 같다. 1. 탐지범위는 송 ${\codt}$ 수파기 직경, 송파음의 강도의 증가와 함께 저주파로 이동하여 어군탐지기의 경우 20${\sim}$50kHz, 바이오텔레메터리의 경우 40${\sim}$80kHz에서 최대치를 나타내었다. 2. 탐지거리는 주파수의 증가와 함께 증가하였지만, 고주파에서는 흡수계수의 영향으로 급격하게 감소하였다. 즉, 송 ${\codt}$ 수파기 직경, 송파음의 강도, TS의 증가 효과는 저주파에서는 크고 고주파에서는 적은 경향을 나타내었다. 3. 바이오텔레메터리에서는 어군탐지기와 같은 송파의 지향성 이득을 얻을 수 없기 때문에 탐지체적의 최대치가 수파기의 직경과 함께 미소하게 감소하였다. 4. 탐지범위는 주파수 특성에 의한 어군탐지기의 음향산란신호를 분석하건, 수산음향계측장치의 설계 및 성능평가에 유효하게 사용될 수 있다.

전침 자극이 정상 성인의 심박변동에 미치는 영향 (Effect of Electroacupuncture Stimulation on Heart Rate Variability in Healthy Adults)

  • 김민수;곽민아;장우석;이기태;정기삼;정태영;서정철;서해경;안희덕
    • Journal of Acupuncture Research
    • /
    • 제20권4호
    • /
    • pp.157-169
    • /
    • 2003
  • Objective : The effects of electroacupuncture(EA) stimulation on heart rate variability(HRV) for healthy adults are investigated with power spectrum analysis(PSA) of HRV. Methods : The HRVs of every 10 minute for 22 healthy volunteers(13 men and 9 women) were measured for an hour with SA-3000P(Medicore Co., Ltd., Korea). The median age with arithmetic range of 13 men and 9 women was 26.00 years with 22.75~27.00 years. The initial 20 minutes were defined as baseline period(pre-EA period), the following 20 minutes as the EA period and the last 20 minutes as the post-EA period. In each EA periods, volunteers received EA(2Hz, 0.6~0.8ms duration, maximal tolerated stimulation without discomfort) on the right Zusanli(ST36), Shangjuxu(ST37) acupoints while supine, resting. Results : Heart rate of volunteers at post-EA period was significantly decreased compare to that of pre-EA period, while SDNN at post-EA period was significantly increased. Heart rate at EA period was significantly decreased compare to that of pre-EA period, but Ln(LF) and LF/HF at EA period were significantly increased. Ln(HF) at post-EA period was significantly decreased compare to that of EA period, while the other variables were not significantly changed. Conclusions : The results suggest that EA in healthy adults is associated with changed activity in the sympathetic and parasympathetic nervous system. Further study is needed for investigating the effects of EA on HRV and autonomic nervous system.

  • PDF

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • ;;김영민;오승진;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

전동력설비의 운전에 의해 발생되는 자계의 측정과 해석 (Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations)

  • 이복희;길경석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권2호
    • /
    • pp.58-67
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]~0.234[mV/$\mu$T]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

  • PDF