• Title/Summary/Keyword: 2-phase model

Search Result 2,349, Processing Time 0.03 seconds

A Economic Evaluation for APR+ Standard Design (APR+ 표준설계에 대한 경제성 분석)

  • Ha, Gag-Hyeon;Lee, Jae-Ho
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.43-47
    • /
    • 2016
  • KHNP CRI has developed APR+ nuclear power plant since 2007, which is GEN III+ model with 1500 MWe capacity. To develop safer nuclear power plant than APR1400, we investigated advanced design features of ALWR being constructed in Korea and being developed/constructed in foreign countries. We applied the advanced design features and lessons learned from Fukushima accident to develop APR+ standard design suitable for both domestic construction and overseas construction business. One economic assessments have performed during safety design improvement phase(2013.1 ~ 2015.12) of APR+. The result of the economic analysis for APR+ safety inhancement design showed that APR+ N-th plant is about 39.2% more economical than coal-fired 1,000MW power plant. Also APR+ plant is more cost advantage over foreign advanced nation ALWRs.

A Study on Upper Ocean Response to Typhoon Ewiniar (0603) and Its Impact (태풍 에위니아 (0603) 통과 후 상층해양 변동 특성과 영향)

  • Jeong, Yeong Yun;Moon, Il-Ju;Kim, Sung-Hun
    • Atmosphere
    • /
    • v.23 no.2
    • /
    • pp.205-220
    • /
    • 2013
  • Upper ocean response to typhoon Ewiniar (0603) and its impact on the following typhoon Bilis (0604) are investigated using observational data and numerical experiments. Data used in this study are obtained from the Ieodo Ocean Research Station (IORS), ARGO, and satellite. Numerical simulations are conducted using 3-dimensional Princeton Ocean Model. Results show that when Ewiniar passes over the western North Pacific, unique oceanic responses are found at two places, One is in East China Sea near Taiwan and another is in the vicinity of IORS. The latter are characterized by a strong sea surface cooling (SSC), $6^{\circ}C$ and $11^{\circ}C$ in simulation and observation, under the condition of typhoon with a fast translation speed (8m $s^{-1}$) and lowering intensity (970 hPa). The record-breaking strong SSC is caused by the Yellow Sea Bottom Cold Water, which produces a strong vertical temperature gradient within a shallow depth of Yellow Sea. The former are also characterized by a strong SSC, $7.5^{\circ}C$ in simulation, with a additional cooling of $4.5^{\circ}C$ after a storm's passage mainly due to enhanced and maintained upwelling process by the resonance coupling of storm translation speed and the gravest mode internal wave phase speed. The numerical simulation reveals that the Ewiniar produced a unfavorable upper-ocean thermal condition, which eventually inhibited the intensification of the following typhoon Bilis. Statistics show that 9% of the typhoons in western North Pacific are influenced by cold wakes produced by a proceeding typhoon. These overall results demonstrate that upper ocean response to a typhoon even after the passage is also important factor to be considered for an accurate intensity prediction of a following typhoon with similar track.

In situ viscoelastic properties of insoluble and porous polysaccharide biopolymer dextran produced by Leuconostoc mesenteroides using particle-tracking microrheology

  • Jeon, Min-Kyung;Kwon, Tae-Hyuk;Park, Jin-Sung;Shin, Jennifer H.
    • Geomechanics and Engineering
    • /
    • v.12 no.5
    • /
    • pp.849-862
    • /
    • 2017
  • With growing interests in using bacterial biopolymers in geotechnical practices, identifying mechanical properties of soft gel-like biopolymers is important in predicting their efficacy in soil modification and treatment. As one of the promising candidates, dextran was found to be produced by Leuconostoc mesenteroides. The model bacteria utilize sucrose as working material and synthesize both soluble and insoluble dextran which forms a complex and inhomogeneous polymer network. However, the traditional rheometer has a limitation to capture in situ properties of inherently porous and inhomogeneous biopolymers. Therefore, we used the particle tracking microrheology to characterize the material properties of the dextran polymer. TEM images revealed a range of pore size mostly less than $20{\mu}m$, showing large pores > $2{\mu}m$ and small pores within the solid matrix whose sizes are less than $1{\mu}m$. Microrheology data showed two distinct regimes in the bacterial dextran, purely viscous pore region of soluble dextran and viscoelastic region of the solid part of insoluble dextran matrix. Diffusive beads represented the soluble dextran dissolved in an aqueous phase, of which viscosity was three times higher than the growth medium viscosity. The local properties of the insoluble dextran were extracted from the results of the minimally moving beads embedded in the dextran matrix or trapped in small pores. At high frequency (${\omega}>0.2Hz$), the insoluble dextran showed the elastic behavior with the storage modulus of ~0.1 Pa. As frequency decreased, the insoluble dextran matrix exhibited the viscoelastic behavior with the decreasing storage modulus in the range of ${\sim}0.1-10^{-3}Pa$ and the increasing loss modulus in the range of ${\sim}10^{-4}-1\;Pa$. The obtained results provide a compilation of frequency-dependent rheological or viscoelastic properties of soft gel-like porous biopolymers at the particular conditions where soil bacteria produce bacterial biopolymers in subsurface.

The Functional Effects for the Prevention and Treatment on Hair Loss from Astringent Persimmon Fruit Extracts (떫은감 추출물의 발모 및 탈모의 기능성 효과)

  • Im, Hyung SiK
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.3
    • /
    • pp.253-259
    • /
    • 2018
  • Astrigent persimmon fruit resources have been used traditionally to treat different systemic diseases and acclaimed for various biological activities including hair growth. This study investigates the hair restoration efficacy of astrigent persimmon fruit extracts on genetically predisposed to balding pattern Black mice model. Water extract of astrigent persimmon fruit(10 mg/mouse/day) with standardized vehicle formulation, only vehicle and positive control minoxidil (2%) were applied daily until completion of two full hair growth generations. The changing pattern of hair growth were observed through two hair growth generations of C57BL/6 Black mice. The hair existing area and hair length was increased significantly (P > 0.001) in astrigent persimmon fruit treated mice than vehicle-treated control mice. Furthermore, histological assessment revealed that the number of hair follicles did not remarkably increase after astrigent persimmon fruit treatment in compare to control mice. Thus, our data revealed that the topical application of astrigent persimmon fruit may promote hair growth in nude mice by extend the hair existing area and increase hair length which is an indicator of prolong anagen phase.

Comparative Evaluation of Intron Prediction Methods and Detection of Plant Genome Annotation Using Intron Length Distributions

  • Yang, Long;Cho, Hwan-Gue
    • Genomics & Informatics
    • /
    • v.10 no.1
    • /
    • pp.58-64
    • /
    • 2012
  • Intron prediction is an important problem of the constantly updated genome annotation. Using two model plant (rice and $Arabidopsis$) genomes, we compared two well-known intron prediction tools: the Blast-Like Alignment Tool (BLAT) and Sim4cc. The results showed that each of the tools had its own advantages and disadvantages. BLAT predicted more than 99% introns of whole genomic introns with a small number of false-positive introns. Sim4cc was successful at finding the correct introns with a false-negative rate of 1.02% to 4.85%, and it needed a longer run time than BLAT. Further, we evaluated the intron information of 10 complete plant genomes. As non-coding sequences, intron lengths are not limited by a triplet codon frame; so, intron lengths have three phases: a multiple of three bases (3n), a multiple of three bases plus one (3n + 1), and a multiple of three bases plus two (3n + 2). It was widely accepted that the percentages of the 3n, 3n + 1, and 3n + 2 introns were quite similar in genomes. Our studies showed that 80% (8/10) of species were similar in terms of the number of three phases. The percentages of 3n introns in $Ostreococcus$ $lucimarinus$ was excessive (47.7%), while in $Ostreococcus$ $tauri$, it was deficient (29.1%). This discrepancy could have been the result of errors in intron prediction. It is suggested that a three-phase evaluation is a fast and effective method of detecting intron annotation problems.

A Study on the Fundamental Cause of Stall Stagnation Phenomena in Surges in Compressor Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.2
    • /
    • pp.119-137
    • /
    • 2017
  • Although the stall stagnation phenomena have often been experienced in site and also analytically in numerical experiments in surges in systems of compressors and flow paths, the fundamental causes have not been identified yet. In order to clarify the situations, behaviours of infinitesimal disturbance waves superposed on a main flow were studied in a simplified one-dimensional flow model. A ratio of the amplifying rate of the system instability to the characteristic slope of the compressor element was surveyed as the instability enhancement factor. Numerical calculations have shown the following tendency of the factor. In the situation where both the sectional area ratio and the length ratio of the delivery flow-path to the suction duct are sufficiently large, the enhancement factors are greater in magnitude, which means occurrence of ordinary deep surges. However, in the situation where the area ratio and/or the length ratio is relatively smaller, the enhancement factor tends to lessen significantly, which situation tends to suppress deep surges for the same value of the characteristic slope. It could result in the stall stagnation condition. In the domain of area ratio vs. length ratio of the delivery duct to the suction duct, contour-lines of the enhancement factor behave qualitatively similar to those of the stall stagnation boundaries of a fan analytically obtained, suggesting that a certain range of the enhancement factor values could specify the stagnation occurrence. The significant decreases in the factors are observed to accompany appearances of phase lags and travelling waves in the wave motions, which macroscopically suggests breaking down of the complete surge actions of filling and emptying of the air in the delivery duct. The strength of the action is deeply related with acoustic interferences and is evaluated in terms of the volume-modified reduced resonance frequency proposed by the author. These observations have shown the fundamental cause and the sequence of the stall stagnation in principle.

Transient analysis of marine propulsion motor and shaft under abnormal conditions (이상상태 발생 시 선박용 추진전동기 및 추진축의 과도상태 해석)

  • Oh, Sae-Gin;Kim, Jong-Su;Kim, Seung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.34-38
    • /
    • 2016
  • Recently, electric propulsion systems are been increasingly used in large cruise ships and merchant vessels. When abnormal electrical conditions occur in the motor of an electric propulsion ship, they can cause serious damage to the motor and propeller shaft. Research on abnormal conditions of propulsion motors used in electric propulsion vessels and electric ships difficult to find. In this study, a mathematical model of the electric propulsion system is proposed to analyze transient phenomena that occur in the case of electric propulsion motor or propeller shaft malfunction. A synchronous motor was used in the MATLAB computer simulation of this study. In the event of electrical malfunction of the electric propulsion motor at rated operation, over current occurs in the condition of 1 phase ground, over torque occurs at 3 and 2 phases ground and over current and torque occur when exciting power fails at rated operation.

A Study of the Properties of Magnetic Particles in Medicinal Ointments (의학용 연고제에 포함된 자성물질 입자들의 성질에 대한 연구)

  • Do, Tae-Sung;Nam, Hyo-Duk;Park, Se-Gon;Hwang, Hyeun-Gook;Hwang, Yong-Soon;Kim, Eng-Chan;Park, Eun-Jung;V. I. Nikolaev;A. V. Bykov
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.69-79
    • /
    • 1997
  • Stability of the properties of magnetite particles in novel medicinal magnetic ointments of multipurpose application has been studied by M ssbauer spectroscopy. It has been found that the comparative analysis of the results obtained by model fitting of $^{57}$ Fe nuclei spectra with those known for the system Fe$_3$O$_4$-${\gamma}$-Fe$_2$O$_3$ allows to identify the phase composition of the particles. It is noted that this composition, as well as that of the initial pure component in the form of a highly dispersed fraction (~100$\AA$), differs noticeably from the stoichiometric one. From the magnetic hyperfine field despite small particle sizes, the particles exhibit no superparamagnetism (in the temperature range from 95 to 300K). Radiative sterilization of the ointments has no effect on the magnetic component composition.

  • PDF

A numerical study on the combined natural convection and radiation in a partially open complex enclosure with a heater and partitions (발열체와 격막이 있고 일부가 열린 복합공간내의 자연대류-복사열전달에 관한 수치적 연구)

  • Kim, Tae-Guk;Min, Dong-Ho;Han, Gyu-Ik;Son, Bong-Se;Seo, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.235-251
    • /
    • 1997
  • A numerical simulation on the combined natural convection and radiation is carried out in a partially open rectangular enclosure with a heater by using the finite volume and the S-8 discrete ordinate methods. The fluid inside the enclosure is considered as an absorbing, emitting and anisotropic scattering media. The heater causes a natural circulation of the fluid (10$^{5}$ $^{9}$ ) which results in significant in-flow of the ambient cold fluid through the partially open wall. Comparing the results of pure convection with those of the combined convection- radiation, the combined heat transfer results with small Planck numbers (P$_{l}$ <1.0) show much stronger circulation than those of the pure convection, and the fluid circulation is more evident for larger Rayleigh numbers. When one of three radiative properties - the medium absorption coefficient, the wall reflectivity, and the scattering albedo - increases, the fluid circulation and the heat transfer in the enclosure are reduced. The location of the heater and the open ratio of the right wall are also shown to affect the fluid circulation and heat transfer significantly. However, the anisotropy of the scattering phase function is shown to be unimportant for the fluid circulation and heat transfer within the enclosure considered in this study.

A Proposal of Risk Management Framework for Design as a Secure Power Control System (안전한 전력 제어시스템 설계를 위한 위험관리 프레임워크 제안)

  • Park, Jun Yong;Shin, Sumin;Song, Kyoung-Young
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.425-433
    • /
    • 2016
  • In smart grid, enhancement of efficiency and interoperability of electric power system is achieved through the connection with outer network, and this induces that power grid system is threatened increasingly, becomes the main target of cyber terrorism, and is sincerely required to design the secure power system. Although SSDLC(Secure System Development Life Cycle) is used for risk management from the design phase, traditional development life cycle is somewhat limited for satisfaction of information security indicator of power control system. Despite that power control system should reflect control entities of information security considering its own characteristics, validation elements are insufficient to apply into real tasks based on existing compliance. To make design of diagnostic model and assessment process for power control system possible and to give a direction for information security and present related indicator, we propose the new risk management framework of power control system which is applied operational security controls and standard architecture presented by IEC 62351 TC 57 with enterprise risk management framework.