• Title/Summary/Keyword: 2-color measurement

Search Result 440, Processing Time 0.029 seconds

Uncertainty Evaluation of Color Measurement on Light Sources and Display Devices (광원 및 디스플레이 기기의 색특성 측정의 불확도 평가)

  • Park, Seong-Chong;Lee, Dong-Hoon;Kim, Yong-Wan;Park, Seung-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.2
    • /
    • pp.110-117
    • /
    • 2009
  • This work introduces the uncertainty evaluation formulation on color measurement of light sources and display devices, such as CIE 1931 (x, y) chromaticity, CIE 1960 (u, v) chromaticity, correlated color temperature, and distribution temperature. All the mentioned quantities are reduced from spectral data in the visible range, for which uncertainties are strongly correlated between different wavelengths. Using matrix algebra we have formulated the uncertainty propagation from the SI- traceable spectral irradiance standard to the individual color related measurement quantities taking the correlation between wavelengths into account. As a result, we have demonstrated uncertainty evaluation examples of 3 types of light sources: CIE illuminant A, LED white light, and LCD white light. This method can be applied to any other quantities based on spectral measurement such as solar irradiance, material color measurement, etc.

A Study on the Measurement of Colour Fastness by CCM and New Fastness Formula (CCM을 이용한 변퇴색 견뢰도 등급의 판정 및 New Fastness Formula에 관한 연구)

  • Hong Min-Gi;Park Ju-Young;Park Yong-Mi;Koo Kang;Huh Man-Woo;Kim Sam-Soo
    • Textile Coloration and Finishing
    • /
    • v.18 no.2 s.87
    • /
    • pp.15-23
    • /
    • 2006
  • A new fastness formula based on CIEDE2000 color-difference formula is developed by B. Rigg and his coworkers. It is very simple to calculate fastness grade for color change than ISO 105-A05 fastness formula based on CIELAB color-difference formula. Sample pair sets which cover a wide range color space were accumulated from NCS(Natural Color System) color book. For those sample pair sets, visual measurement experiment and instrument measurement experiment of fastness grade were carried out and each performance of ISO 105-A02 fastness formula and newly developed fastness formula was compared through degree of agreement for visual measurement result. Newly developed fastness formula indicated improved performance for measuring fastness grade but current ISO fastness formula for assessing change in color, ISO 105-A05, was confirmed that it's performance is inadequate to measure fastness grade. Then fastness formulae were examined more closely according to particular color spaces and the correlation of hue, lightness and chrom for measuring fastness grade was also considered in this study.

A Study on the Subjective Evaluation of Color Appearance under the Different LED CCT Conditions (색온도별 LED 조명에 의한 색상별 색보임에 대한 주관평가 연구)

  • Kim, Hyun-Sun;Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.43-52
    • /
    • 2011
  • LED lighting may cause different sensation and color appearance due to the different spectral power distributions compared to those of conventional lightings. Particularly, the CCT (Correlated Color Temperature) of LED lighting has a major effect on color appearance so that this study conducted an experiment through a subjective evaluation and luminance measurement for effective color appearance in a space. This study performed a subjective evaluation under the seven different LED CCT conditions, and color appearance was evaluated with major five colors in a customized lighting box. In addition, luminance measurement was conducted for each CCT and color condition to compare the results from a subjective evaluation. The results of this study may help to select a proper LED CCT for specific color conditions.

Two-dimensional Oxygen Distribution in a Surface Sediment Layer Measured Using an RGB Color Ratiometric Oxygen Planar Optode (RGB color ratiomatric planar optode로 측정한 표층 퇴적물의 2차원 산소 분포)

  • Lee, Jae Seong;Kim, Eun-Soo;An, Sung-Uk;Kim, Jihye;Kim, Joung-Keun;Khang, Sung-Hyun;Kang, Dong-Jin
    • Ocean and Polar Research
    • /
    • v.35 no.3
    • /
    • pp.229-237
    • /
    • 2013
  • We measured two-dimensional (2-D) oxygen distribution in the surface sediment layer of intertidal sediment using a simple and inexpensive planar oxygen optode, which is based on a color ratiometric image approach. The recorded emission intensity of red color luminophore light significantly changed with oxygen concentration by $O_2$ quenching of platinum(II)octaethylporphyrin (PtOEP). The ratios between the intensity of red and green emissions with oxygen concentration variation demonstrated the Stern-Volmer relationship. The 2-D oxygen distribution image showed microtopographic structure, diffusivity boundary layer and burrow in surface sediment layer. The oxygen penetration depth (OPD) was about 2 mm and the one-dimensional vertical diffusive oxygen uptake (DOU) was 12.6 mmol $m^{-2}d^{-1}$ in the undisturbed surface sediment layer. However, those were enhanced near burrow by benthic fauna, and the OPD was two times deeper and DOU was increased by 34%. The simple and inexpensive oxygen planar optode has great application potential in the study of oxygen dynamics with high spatiotemporal resolution, in benthic boundary layers.

A new color management approach for dye manufacturing process with image processing and intelligent algorithm

  • Kyungwon Jang;Taechon Ahn;Lee, Dongyoon;Yangwoong Yoon;Jinhyun Kang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.56.2-56
    • /
    • 2002
  • A dye process of textile industry is important part that finally gives required quality to the textile material. To produce a proper dye for the customers, color management that precise color measurement from original color sample and rapid estimation of corresponding color recipe is most essential. In the practical dye manufacturing process, color management falls into two categories. First one is color management with an expert knowledge of colorist, the other one is computer aided way. In the former management way, color management fully depends on colorists' expert without support of the measurement and computational devices. Objective color management is impossible in this way. The...

  • PDF

Development of an Illumination Measurement Device for Color Distribution Based on a CIE 1931 XYZ Sensor

  • Son, Do-Ky;Cho, Eun-Byeol;Moon, In-Kyu;Park, You-Sang;Lee, Chung-Ghiu
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.44-51
    • /
    • 2011
  • In this paper, an easy-to-use measurement device for illumination distribution is developed. The device consists of a sensor array module, a control module, and a PC interface. The sensor array module incorporates CIE 1931 color sensors and the ARM-based 96 MHz microcontroller in the control module for measurement and data processing. The sensor array module contains 64 color sensors arranged in a $16{\times}4$ array. The sensitivity of the sensor array module can be adjusted depending on the illumination level to be measured. The measurement data and control signals are exchanged via USB 2.0 standard. To demonstrate the performance of the device, the illumination distribution is measured for colors of red, green, and blue and is graphically shown. The device can be used for measurement of the illumination distribution, design and adjustment of LED illumination.

Relationship between Soil Color Characteristics and Measurement Values by Colorimeter (토양의 색 특성과 색차계 측정치의 상호관계)

  • Kim, Ki-In;Hong, Soon-Dal
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.35 no.2
    • /
    • pp.77-86
    • /
    • 2002
  • Soil color characteristics were measured by a optical instrument, colorimeter, comparing with the conventional Munsell color chart and related to the chemical properties of soils. Total of the 67 experimental soils were taken from tobacco fields that located at Cheongwon, Enmseong, Boeun, Goesan, Jincheon, and Chungju countries in Chungbuk Province having the 29 soil series including Samgag. The values of L, a, and b measured by colorimeter were closely related with hue, value, and chroma of Munsell color chart, respectively, indicating the quantitative measurement of soil color characteristics. The standard deviations in measurement for L, a, and b values was smaller in soil sample passed by 0.5 mm sieve than 2 mm sieve, suggesting that soil particle size less than 0.5 mm was better condition for colorimeter measurement. The values of L and b measured by colorimeter showed a tendency to decrease as increase of soil moisture content but nearly on difference with moisture condition for the value of a. However, correlation coefficient between air dry samples and wet soil samples(soil moisture retension of -10 hPa) for measurements of L, a and b value were more than 0.9 showing the same tendency in measurement. Consequently, air dry soil passed by 0.5 mm sieve was recommended to desirable conditions for stable measurement by colorimeter. The measured values by colorimeter were significantly correlated with organic matter, CEC, exchangeable Ca and Mg, showing the highest correlation coefficient between L value and organic matter.

Testing the Reliability of the Pain Color Circle Measurement Tool (색채동통척도의 신뢰도 연구)

  • 김주희
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.339-348
    • /
    • 1991
  • The study problem was to determine the reliability of the Stewart pain circle measurement tool with Korean subjects. The purpose was to assess the tool for potential use in research in Korea. The subjects were 95 primary school students and 103 university students in Seoul. The study was conducted from May to June 1990, using Stewart's pain color circle tool. To determine the difference in the rated intensity of the order of the pain color circles, statistical mean and standard deviation were employed. Item reliability and test - retest reliability were used to test for reliability. ANOVA and t-test were used to explore for differences in the rated intensity of the order of the pain color circles according to the subjects' general characteristics. The findings were as follows ; 1. Higher level pain intensity was assigned to color circle numbers 2, 4, and 6 (These contain large amounts of color). Lower level pain intensity was assigned to numbers 1, 3, and 5(These contain small amounts of color). Higher and lower levels of pain intensity selection patterns were the same as Stewart's but the highest rating of pain was different. The highest pain intensity rating was given to the color red in this study instead of black as in Stewart's test. 2. University students and primary school students' ratings were not very difteferent. 3. Pain color circle reliability was $\alpha$=0.3468, Test - retest reliability was supported (t=0.02~0.97, p=0.337~0.988) 4. Differences in the rating of the pain intensity order were related to the subjects' age and sex, but not to religion. It was concluded that the pain color circle measurement tool is worth for further study as a research instrument with both Korean adult and child clients for validity and reliability.

  • PDF

Analysis of Facial Coloration in Accordance with the Type of Personal Color System of Female University Students (여대생의 퍼스널 컬러 시스템 유형에 따른 얼굴색 분석)

  • Lee, Eun-Young;Park, Kil-Soon
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.2
    • /
    • pp.144-153
    • /
    • 2012
  • This study performed a simultaneous sensory evaluation and color measurement, targeting 136 female university students who live in the Dae-Jeon region. the study measured participants'facial coloration under the condition of available light between 11 AM and 3 PM from Spring (May) to Autumn (October) in 2009. For statistical analysis, descriptive statistics, a member variate analysis, and discriminant analysis were executed using SPSS version 18.0 of the statistics program. The results of this study are as follows. First, as a result of the sensory evaluation, the blue undertone well matched to face type was dominantly distributed among the female university student participants. Second, the forehead showed a type of yellowish coloration and was relatively dark to cheeks. However the cheek displayed a reddish coloration and was relatively bright compared to the forehead from an evaluation of a cheek and forehead color measurement. Third, due to the investigation the of facial coloration variable, a yellowish and reddish chromaticity on the cheek were evident as a variable of facial coloration, which has an influence on the classification of the types of facial color. As a result of the induced discriminant through these two color variables, the yellowish chromaticity appeared as a color variable to have a greater influence than the reddish chromaticity on the cheek.

Improvement of Calibration Method of Thermochromic Liquid Crystal Reflecting Measurement Angle (측정각도를 고려한 액정교정기법의 개선)

  • Yoon, Soon-Hyun;Sim, Jae-Kyung;Woo, Chang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.188-194
    • /
    • 2000
  • Thermochromic liquid crystal reflect a unique color at even temperature. Therefore, they have been successfully applied to non-intrusive heat transfer research. Hue capturing method is widely used in the quantitative measurement from the TLC image. However it is affected by several measurement conditions. The distances of camera and light source have little influence on the color, but the value of hue is seriously affected by the measurement angle. In this study, the hue capturing method is improved by considering the effect of measurement angle. This improved calibration method can diminish the misreading of temperature caused by curvature of test surface.