• Title/Summary/Keyword: 2-axis

Search Result 4,923, Processing Time 0.035 seconds

Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma (간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Keum Ki Chang;Lee Sang-wook;Shin Hyun Soo;Kim Gwi Eon;Sung Jinsil Seong;Lee Chang Geol;Chu Sung Sil;Chang Sei-Kyung;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • Purpose : The goal of this study 닌as to improve the accuracy of three-dimensional conformal radiotherapy (3-D CRT) by measuring the treatment setup error and physiological movement of liver based on the analysis of images which were obtained by electronic portal imaging device (EPID). Materials and Methods : For 10 patients with hepatocellular carcinoma, 4-7 portal images were obtained by using EPID during the radiotherapy from each patient daiiy. We analyzed the setup error and physiological movement of liver based on the verification data. We also determined the safety margin of the tumor in 3-D CRT through the analysis of physiological movement. Results : The setup errors were measured as 3mm with standard deviation 1.70 mm in x direction and 3.7 mm with standard deviation 1.88 mm in y direction respectively. Hence, deviation were smaller than 5mm from the center of each axis. The measured range of liver movement due to the physiological motion was 8.63 mm on the average. Considering the motion of liver and setup error, the safety margin of tumor was at least 15 mm. Conclusion : EPID is a very useful device for the determination of the optimal margin of the tumor, and thus enhance the accuracy and stability of the 3-D CRT in patients with hepatocellular carcinoma.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Analysis of Image Processing Characteristics in Computed Radiography System by Virtual Digital Test Pattern Method (Virtual Digital Test Pattern Method를 이용한 CR 시스템의 영상처리 특성 분석)

  • Choi, In-Seok;Kim, Jung-Min;Oh, Hye-Kyong;Kim, You-Hyun;Lee, Ki-Sung;Jeong, Hoi-Woun;Choi, Seok-Yoon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.97-107
    • /
    • 2010
  • The objectives of this study is to figure out the unknown image processing methods of commercial CR system. We have implemented the processing curve of each Look up table(LUT) in REGIUS 150 CR system by using virtual digital test pattern method. The characteristic of Dry Imager was measured also. First of all, we have generated the virtual digital test pattern file with binary file editor. This file was used as an input data of CR system (REGIUS 150 CR system, KONICA MINOLTA). The DICOM files which were automatically generated output files by the CR system, were used to figure out the processing curves of each LUT modes (THX, ST, STM, LUM, BONE, LIN). The gradation curves of Dry Imager were also measured to figure out the characteristics of hard copy image. According to the results of each parameters, we identified the characteristics of image processing parameter in CR system. The processing curves which were measured by this proposed method showed the characteristics of CR system. And we found the linearity of Dry Imager in the middle area of processing curves. With these results, we found that the relationships between the curves and each parameters. The G value is related to the slope and the S value is related to the shift in x-axis of processing curves. In conclusion, the image processing method of the each commercial CR systems are different, and they are concealed. This proposed method which uses virtual digital test pattern can measure the characteristics of parameters for the image processing patterns in the CR system. We expect that the proposed method is useful to analogize the image processing means not only for this CR system, but also for the other commercial CR systems.

Comparison of mandibular anterior alveolar bone thickness in different facial skeletal types (성인에서의 수평적, 수직적 안면 골격 형태에 따른 하악 전치부 치조골 두께의 비교)

  • Kim, Yoon-Soo;Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.314-324
    • /
    • 2010
  • Objective: The purpose of this study was to determine differences of mandibular anterior alveolar bone thickness and symphysial cross sectional area in 9 different horizontal and vertical facial types. Methods: By using the initial cephalometric radiographs of 270 adult patients (male 135, female 135), the authors measured the buccolingual thickness of anterior alveolar bone on the basis of the root axis and symphysial cross sectional distance. Results: The high angle group showed significantly thinner buccolingual alveolar bone width except for the CEJ area and lingual alveolar bone width ($p$ < 0.05). The low angle group and Class I, II average group showed similar or significantly thicker alveolar bone width than the Class I average group ($p$ < 0.05). The Class III average group showed significantly thinner buccolingual and lingual alveolar bone width than Class I and II average groups ($p$ < 0.05). The Class III high angle group showed minimal alveolar bone width in all facial skeletal types. No significant difference was found in the symphysial cross sectional area of the different vertical facial skeletal types ($p$ > 0.05). Conclusions: The results of this study found that Class III high angle patients have thinner mandibular anterior alveolar bone thickness; therefore, more attention will be needed to determine the incisor position during orthodontic treatment for this group of patients.

Leaf epidermal structure of the Allium L. and its taxonomic significance (부추속(Allium L.) 잎 표피의 구조와 이의 분류학적 중요성)

  • Choi, Hyeok-Jae;Jang, Chang-Gee;Ko, Sung-Chul;Oh, Byoung-Un
    • Korean Journal of Plant Taxonomy
    • /
    • v.34 no.2
    • /
    • pp.97-118
    • /
    • 2004
  • A comparative anatomical and ultrastructural study was undertaken to investigare on the leaf epidermis by light microscopy (LM) and scanning electron microscopy (SEM). On the basis of results from this study, it was grasped major characters of taxa and variation range of each character on the level of species, section and subgenus respectively. The shape of leaf epidermal cell was oblong to linear, which was varied by each taxon. Epidermal cell of taxa in sects. Microscordum, Anguinum, and Rhizirideum, which had wide leaf blade, oblong instead of linear shape in others examined taxa in this study. The leaf of taxa in sect. Anguinum was hypostomatic, while the rest of taxa had amphistomatic leaf. This was also one of characters which could discriminate taxa of sect. Anguinum from others. The guard cell in investigated taxa had not so much variation in the respect of its size. The number of stomata per unit area reduced by increasing size of epidermal cell, the fewest number of stomata per unit area was found in the taxa of sect. Anguinum. The type of stomatal apparatus of observed all taxa was anomocytic. It was found to know ultrastructural variation in the epidermal cell, like as patterns of sculpture on the cell wall, and features of deposition of wax by SEM. There were no depositions of wax in the taxa of sect. Microscordum and Anguinum, but fine thread-like structures which were parallel or cross to axis was found on the surface of epidermal cell respectively. The patterns of sculpture on the cell were prominent straight in sects. Recticulato-bulbosa and Rhizirideum, discontinuous line in the sect. Oreiprason. The epicuticular wax had been deposited on the surface of its epidermal cell in all taxa except sects. Microscordum and Anguinum.

Study on Analysis of Influence Factor for Wildbirds' Appearance in Urban Area around Urban Green Axis - A Case Sturdy of Gangdong-gu in Seoul - (도시 녹지축 주변 시가화지역 내 야생조류 출현 영향요인 분석 연구)

  • Kwak, Jeong-In;Lee, Kyoung-Jae;Han, Bong-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.2
    • /
    • pp.166-177
    • /
    • 2010
  • This study is to identify potential factors to impact on appearance of wildbirds which live in the core forest around urban area in Gangdong-gu, Seoul. As a result of analysis of, studies on biotope showed most of urbanization biotope was biotope of residential areas with high green coverage and biotope of residential and business areas with low green coverage while most of biotope of green and openspace was core green biotope. The research area was divided into several blocks based on biotope types in the urbanization areas excluding green and openspace. As a result of research on wildbirds, total 51 species 3,419 individuals appeared in spring and total 35 species 4,213 individuals appeared in winter. 24 wild bird species were selected as subjects of this study among 31 species seen in urbanization areas, since urban birds, rapacious birds, waterside birds were excluded from the study for the proper consideration. Then this study looked at how many species and individuals of the subjects were observed at each research block in urbanization areas during spring and winter separately. Landuse structure and green structure in each block were examined to see whether these structures affect the number of wild birds observed in urbanization areas of Gangdong-gu. Furthermore, the distance between these blocks and green was assessed. While studying the potential links between the landuse structure and the number of wild birds observed in urbanization areas of Gangdong-gu, block area, green coverage, and building-to-land ratio were believed to affect the number of types and species of wild birds in the research area. In terms of correlation analysis of whether green structure affected the number of wild birds observed in urbanization areas of Gangdong-gu, crown volume of layers, the average green patch area, the average height of canopy layer were found to have an impact not only on the number of types but also species of wild birds in the research area.

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

Studies on the Construction and the Artificial Mountain Theory of Amisan in the Gyeongbok Palace (경복궁 아미산의 조영과 조산설(造山說)에 관한 고찰)

  • Jung, Woo-Jin;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.30 no.2
    • /
    • pp.72-89
    • /
    • 2012
  • This study aimed to reconsider the theory that the renowned Amisan(峨眉山) terraced garden at north of Gyotaejeon(交泰殿) was artificially made, by reviewing the historical records and drawings. It has been widely accepted that Amisan was made of the digged soil from Gyeonghoeji(慶會池). But several arguments about artificial mountain theory of Amisan that completely not be found in historical records have been raised in this study. The results were summarized as follows; the inherent contradiction in existing opinion, the discordance between the time of building Gyeonghoeji and Gyotaejeon, the existence of the mountain range which connect Baekaksan and Amisan appeared in Dohyeong(圖形), historical documents written in the years of kingdoms of Youngjo(英祖) and Gojong(高宗), a high position seen from Heungbogjeon(興復殿) in the north Amisan through the wall in the east but impassable, an opinion about realization Amisan as geomantic term of Amisa(蛾眉砂) at the time of Gyeongbok Palace reconstruction, and preservation of the mountain range in Gyeongbok Palace that comes from the result of the arguments in main mountain of Gyeongbok Palace in the year of Sejong(世宗). In addition, it was investigated why the slop in the north of Gyotaejeon was named as Aminsan and why the artificial mountain theory is appeared and made a conclusion that the Amisan comes from the change of the pronunciation of the geomantic term "Amisa", and modeling the yijing[意景] of Amisan which is a sacred place of Taoism and Buddhism in Sichuan[四川] of Chinaand the view of construction to mean defeating a spirit of smallpox which had to be cured. And it seems to be a result which retroactively applied the artificial mountain theory of Amisanis the technique of 'constructing mountain with digged pond dirt' to the relationship between Gyeonghoeji and Amisan. The greater part of mountain range which was connecting with Baekaksan and Amisan was seriously disconnected with large scale of exposition by the Japanese colonial period in 1915. But low slope is kept about 70 meters along the trail northeast of Gyotaejeon. Accordingly, it is judged that the range has not been entirely destroyed. And according to the result of elevation analysis, discontinuous slope form certain axis is found, so the mountain range of Amisan is approximately estimated. This basic research about the mountain range of Amisan might provide a critical clue about restoration of topography in Gyeongbok Palace.

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.