• 제목/요약/키워드: 2-D measurement

검색결과 3,175건 처리시간 0.031초

450自由衝突 噴射 의 亂流流動 에 관한 實驗的 硏究 (An Experimental Study on the Turbulent Flow of a 45$^{\circ}C$ Free Cross Jet)

  • 노병준;김장권
    • 대한기계학회논문집
    • /
    • 제8권5호
    • /
    • pp.442-449
    • /
    • 1984
  • 본 연구에서는 두 분류가 교우되어 배합이 이루어지는 유동역에서 3차원 방향 에 대하여 평균속도분포, 난류강도분포, 난류전단응력분포, 상관계수의 분포 및 난류 운동에너지와 운동량의 변화 등을 측정 분석하였다.

복합 유기용제 취급 근로자의 혈액 및 뇨검사 결과 분석 (Hematologic Findings & Urinalysis of Workers Exposed to Mixed Organic Solvents)

  • 정귀원;김대환;엄상화;김성준;김정호;문선순;전진호;김용완
    • Journal of Preventive Medicine and Public Health
    • /
    • 제24권3호
    • /
    • pp.314-327
    • /
    • 1991
  • To evaluate the effects on health by exposure to mixed organic solvents, the author analyzed some labortory findings of blood (hemoglobin, hematocrit RBC, WBC, SGOT, SGPT) and urine (protein, blood, sugar) that were obtained from 722 workers (male:446, female:276) who worked in plywood, painting and shoes factories in Pusan area from January to December, 1990. The result were as follows ; 1. The mean values of each hematologic findings were all within normal limit but there were significant differences at hematocrit, RBC, WBC, SGOT in male and at WBC, SGPT in female at the comparison of the mean values and the distribution according to the normal criteria by type of work. 2. There were no differences in urinalysis(protein, blood, sugar) by type of work. 3. In stepwise multiple regression, analysis of hematologic findings on age, working duration and type of work, regression coefficients on age and type of work were relatively high in male and female sub1, respectively. As a result of this study, it is considered that the measurement of WBC with morphology is significant in hematologic findings and instead of spot urine and urinstix, 24 hours urine and quantitative analysis is required in urinalysis in screening test for healthy status of workers who deal with the organic solvents.

  • PDF

핵의학 영상기기의 최근 진보 (Recent Advances in Nuclear Medicine Imaging Instrumentation)

  • 정진호;최용;홍기조;민병준;호위;강지훈
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

BATHYMETRIC MODULATION ON WAVE SPECTRA

  • Liu, Cho-Teng;Doong, Dong-Jiing
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.344-347
    • /
    • 2008
  • Ocean surface waves may be modified by ocean current and their observation may be severely distorted if the observer is on a moving platform with changing speed. Tidal current near a sill varies inversely with the water depth, and results spatially inhomogeneous modulation on the surface waves near the sill. For waves propagating upstream, they will encounter stronger current before reaching the sill, and therefore, they will shorten their wavelength with frequency unchanged, increase its amplitude, and it may break if the wave height is larger than 1/7 of the wavelength. These small scale (${\sim}$ 1 km changes is not suitable for satellite radar observation. Spatial distribution of wave-height spectra S(x, y) can not be acquired from wave gauges that are designed for collecting 2-D wave spectra at fixed locations, nor from satellite radar image which is more suitable for observing long swells. Optical images collected from cameras on-board a ship, over high-ground, or onboard an unmanned auto-piloting vehicle (UAV) may have pixel size that is small enough to resolve decimeter-scale short gravity waves. If diffuse sky light is the only source of lighting and it is uniform in camera-viewing directions, then the image intensity is proportional to the surface reflectance R(x, y) of diffuse light, and R is directly related to the surface slope. The slope spectrum and wave-height spectra S(x, y) may then be derived from R(x, y). The results are compared with the in situ measurement of wave spectra over Keelung Sill from a research vessel. The application of this method is for analysis and interpretation of satellite images on studies of current and wave interaction that often require fine scale information of wave-height spectra S(x, y) that changes dynamically with time and space.

  • PDF

상수리나무와 자작나무 소재(素材)에 대한 Nitrocellulose Clear Lacquer 도막(塗膜)의 할열(割裂)에 관(關)한 연구(硏究) (Studies on the Cracking of Nitrocellulose Clear Lacquer Coasted Films on Solid Woods of Quercus acutissima and Betula platyphylla var. japonica)

  • 김현중;이필우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제17권1호
    • /
    • pp.55-68
    • /
    • 1989
  • This experiment was carried out to investigate the crack of coated Nitrocellulose Lacquer on flatand edge-grained boards of Quercus acutissima, ring-porous wood, and Betula platyphylla var. japonica, diffuse-porous wood, by variations of moisture contents at 7, 13 and 21%. Cold check system was used as an accelerating method for crack development, in which one cycle of the system consisted of 10 replications of each unit cycle, $60^{\circ}C$ for 4hr followdd by $-20^{\circ}C$ for 4hr. The analysis of Nitrocellulose Lacquer characteristics was made by means of water permeation measurement, F.T.I.R. spectroscopy, N.M.R. spectroscopy, gel permeation chromatography, gas chromatography, and D.S.C. The results obtained were as follows: 1. The number of cracks increased with the increasing moisture content of board. 2. The crack of coated film on flat-grained board was fewer in number than on edge-grained board. 3. The crack occurred in Quercus acutissima was more numerous on edge-grained board but less frequent on flat-grained board compared with that in Betula platyphylla var. japonica, respectively. 4. The cold crack vertically developed to the grain both in Quercus acutissima and Betula platyphylla var. japonica. 5. Water permeability in intermediate coated film was lower than in under and top coated film, but the difference was not confirmed between under and top coated film.

  • PDF

한강원수 자연유기물의 특성분석 및 강화응집 기준 평가 (Characteristics of Natural Organic Matter (NOM) on Han River and Criterion of Enhanced Coagulation)

  • 정영미;권지향;이상협
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.653-661
    • /
    • 2007
  • The Disinfectants/Disinfection By-products (D/DBP) Rule proposed by the US Environmental Protection Agency requires the implementation of enhanced coagulation as a control strategy for natural organic matter (NOM) removal and as a means of limiting the formation of all DBPs, i.e., not just the trihalomethanes and haloacetica acids. To control DBP formation, several best available technologies (BATs) were determined for removal of DBPs and DBP precursors. The enhanced coagulation is one of the BATs for DBP precursors removal. Treatment facilities that achieve a specified percent removal of total organic carbon (TOC) prior to the application of a continuous disinfectant or that achieve a residual TOC concentration < 2mg/L prior to the application of a continuous disinfectant are considered to be in compliance with enhanced coagulation. The enhanced coagulation was applied to raw water in Korea, the Han River. Raw water were examined and effects of different raw water qualities on enhanced coagulation were investigated. Three analyses were used for raw water characteristics, water quality measurement, molecular weight distributions, hydrophobic/hydrophilic fractionation. The Han River had the relatively low alkalinity and low organic carbon concentration. The results of molecular weight distributions showed significant portions of low molecular weight organics, which is very different from most water in USA. The alum doses for the required TOC removal guided from USEPA manual were quite low (i.e. 10~30 mg/L alum) for the water, probably due to the specific water quality of the Han River.

마이크로 머시닝 기술을 이용한 니켈기반의 압전 진동형 에너지 하베스터 제작 (Fabrication of Nickel-based Piezoelectric Energy Harvester from Ambient Vibration with Micromachining Technology)

  • 차두열;이재혁;장성필
    • 한국전기전자재료학회논문지
    • /
    • 제25권1호
    • /
    • pp.62-67
    • /
    • 2012
  • Owing to the rapid growth of mobile and electronic equipment miniaturization technology, the supply of micro mobile computing machine has been fast raised. Accordingly they have performed many researches on energy harvesting technology to provide promising power supply equipment to substitute existing batteries. In this paper, in order to have low resonance frequency for piezoelectric energy harvester, we have tried to make it larger than before by adopting nickel that has much higher density than silicon. We have applied it for our energy harvesting actuator instead of the existing silicon based actuator. Through such new concept and approach, we have designed energy harvesting device and made it personally by making with micromachining process. The energy harvester structure has a cantilever type and has a dimension of $10{\times}2.5{\times}0.1\;mm^3$ for length, width and thickness respectively. Its electrode type is formed by using Au/Ti of interdigitate d33 mode. The pattern size and gap size is 50 ${\mu}m$. Based on the measurement of the nickel-based piezoelectric energy harvester, it is found to have 778 Hz for a resonant frequency with no proof mass. In that resonance frequency we could get a maximum output power of 76 ${\mu}W$ at 4.8 $M{\Omega}$ being applied with 1 g acceleration.

3 차원 레이저 스캐닝을 이용한 터널의 천단 및 내공 변위 관측 (Tunnel Convergence and Crown Settlement Using 3D Laser Scanning)

  • 이재원;윤부열
    • 대한공간정보학회지
    • /
    • 제15권2호통권40호
    • /
    • pp.67-75
    • /
    • 2007
  • 터널 구조물 시공시에 수많은 위험요소를 가지고 있다. 이러한 요소들을 미연에 방지하고 안정성 확보를 위해서는 터널 내부의 변위에 대한 정확하고 신속한 관측이 요구된다. 그러나 현재 천단침하, 내공변위, 지표침하 등은 토탈 스테이션. 각종 계측기를 이용하는 보편적인 측량 방법에 의존하고 있는 실정이다. 최근 측량기술의 향상과 개발에 따른 구조물의 유지관리에 대한 자료를 제공하기 위한 방법으로 3차원 레이저 스캐닝을 이용하여 기존 구조물의 변형량 계측방법의 신뢰성 문제를 해결하고, 구조물의 형태 변화를 3차원화 하여 시각적으로 판단할 수 있는 자료를 제시하고 빠른 대책을 강구할 수 있도록 하여 구조물의 유지관리 및 현장계측에 능률적으로 활용할 수 있도록 하였다.

  • PDF

Acquisition of Grass Harvesting Characteristics Information and Improvement of the Accuracy of Topographical Surveys for the GIS by Sensor Fusion (I) - Analysis of Grass Harvesting Characteristics by Sensor Fusion -

  • Choi, Jong-Min;Kim, Woong;Kang, Tae-Hwan
    • Journal of Biosystems Engineering
    • /
    • 제40권1호
    • /
    • pp.28-34
    • /
    • 2015
  • Purpose: This study aimed to install an RTK-GPS (Real Time Kinematic-Global Positioning System) and IMU (Inertial Measurement Unit) on a tractor used in a farm to measure positions, pasture topography, posture angles, and vibration accelerations, translate the information into maps using the GIS, analyze the characteristics of grass harvesting work, and establish new technologies and construction standards for pasture infrastructure improvement based on the analyzed data. Method: Tractor's roll, pitch, and yaw angles and vibration accelerations along the three axes during grass harvesting were measured and a GIS map prepared from the data. A VRS/RTK-GPS (MS750, Trimble, USA) tractor position measuring system and an IMU (JCS-7401A, JAE, JAPAN) tractor vibration acceleration measuring systems were mounted on top of a tractor and below the operator's seat to obtain acceleration in the direction of progression, transverse acceleration, and vertical acceleration at 10Hz. In addition, information on regions with bad workability was obtained from an operator performing grass harvesting and compared with information on changes in tractor posture angles and vibration acceleration. Results: Roll and pitch angles based on the y-axis, the direction of forward movements of tractor coordinate systems, changed by at least $9-13^{\circ}$ and $8-11^{\circ}$ respectively, leading to changes in working postures in the central and northern parts of the pasture that were designated as regions with bad workability during grass harvesting. These changes were larger than those in other regions. The synthesized vectors of the vibration accelerations along the y-axis, the x-axis (transverse direction), and the z-axis (vertical direction) were higher in the central and northwestern parts of the pasture at 3.0-4.5 m/s2 compared with other regions. Conclusions: The GIS map developed using information on posture angles and vibration accelerations by position in the pasture is considered sufficiently utilizable as data for selection of construction locations for pasture infrastructure improvement.