• Title/Summary/Keyword: 2-D measurement

Search Result 3,175, Processing Time 0.031 seconds

Analysis on the Shape and Size of Sanitary Pads and User Experience Evaluation (여성위생용품 형태 및 사이즈 분석과 사용성 평가)

  • Kim, Yeon Soo;Kim, Sujeung;Lee, Sujin;Kim, Dong-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.3
    • /
    • pp.485-498
    • /
    • 2020
  • Sanitary pads are used with for the sanitization of menstruation bleeding. In this research, twenty medium size disposable sanitary pads were selected from domestic and international brands in order to analyze their shape and size. Additionally, 6 sanitary pads were selected among the 20, and user experience evaluations were completed. The analysis on the shape of the 20 sanitary pads showed that straight-shape pads existed more than curved-shape pads. The means of total pad length, wing length, wing width, front pad width, back pad width, front pad length, and back pad length were 24.5 cm, 8.8 cm, 3.0 cm, 10.0 cm, 10.2 cm, 11.6 cm, and 13.0 cm, respectively. All selected pads were medium size; however, detailed sizes varied between brands. Eighty-one women participated on user experience evaluation. Participants felt that brand F was the longest and brand D the shortest. The results matched with the results on actual pad length measurement. Participants evaluated the fit of brand E most positively and fit of brand A most negatively. The current study provides valuable information for developing disposable sanitary pads.

CHARACTERISTICS OF THE CONTAMINATED LANGMUIR PROBE (오염된 LANGMUIR 탐침의 특성)

  • Pyo, Y. S.;Min, K. W.;Choi, Y. W.;Lee, D. H.;Kang, K. M.;Hwang, S. M.;Kim, B. C.;Kim, J.;Lee, S. J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.234-243
    • /
    • 1995
  • Korea's third rocket, which is currently under development for launch in 1997, is expected to reach as high as 160km and thus, it will provide a good opportunity for the direct measurement of the plasmas in the E-region ionosphere of the Korean peninsula. Langmuir probe techniques, which are the basic tools of the plasma experiment, may yield inaccurate results if they are applied in the conventional form as they are used in the laboratory experiments because of the contamination. In the present paper we study the contamination problem by performing the ground experiments in the vacuum chamber using the contaminated probe. The result show that the contamination effect is reduced when the plasma density is low or when the frequency of the sweep voltage is fast. We propose a modified Langmuir probe based upon our experiments which is suitable for the rocket experiments.

  • PDF

Genetic Association of the Porcine C9 Complement Component with Hemolytic Complement Activity

  • Khoa, D.V.A.;Wimmers, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.9
    • /
    • pp.1354-1361
    • /
    • 2015
  • The complement system is a part of the natural immune regulation mechanism against invading pathogens. Complement activation from three different pathways (classical, lectin, and alternative) leads to the formation of C5-convertase, an enzyme for cleavage of C5 into C5a and C5b, followed by C6, C7, C8, and C9 in membrane attack complex. The C9 is the last complement component of the terminal lytic pathway, which plays an important role in lysis of the target cells depending on its self-polymerization to form transmembrane channels. To address the association of C9 with traits related to disease resistance, the complete porcine C9 cDNA was comparatively sequenced to detect single nucleotide polymorphisms (SNPs) in pigs of the breeds Hampshire (HS), Duroc (DU), Berlin miniature pig (BMP), German Landrace (LR), Pietrain (PIE), and Muong Khuong (Vietnamese potbelly pig). Genotyping was performed in 417 $F_2$ animals of a resource population (DUMI: $DU{\times}BMP$) that were vaccinated with Mycoplasma hyopneumoniae, Aujeszky diseases virus and porcine respiratory and reproductive syndrome virus at 6, 14 and 16 weeks of age, respectively. Two SNPs were detected within the third exon. One of them has an amino acid substitution. The European porcine breeds (LR and PIE) show higher allele frequency of these SNPs than Vietnamese porcine breed (MK). Association of the substitution SNP with hemolytic complement activity indicated statistically significant differences between genotypes in the classical pathway but not in the alternative pathway. The interactions between eight time points of measurement of complement activity before and after vaccinations and genotypes were significantly different. The difference in hemolytic complement activity in the both pathways depends on genotype, kind of vaccine, age and the interaction to the other complement components. These results promote the porcine C9 (pC9) as a candidate gene to improve general animal health in the future.

Real-time moving object tracking and distance measurement system using stereo camera (스테레오 카메라를 이용한 이동객체의 실시간 추적과 거리 측정 시스템)

  • Lee, Dong-Seok;Lee, Dong-Wook;Kim, Su-Dong;Kim, Tae-June;Yoo, Ji-Sang
    • Journal of Broadcast Engineering
    • /
    • v.14 no.3
    • /
    • pp.366-377
    • /
    • 2009
  • In this paper, we implement the real-time system which extracts 3-dimensional coordinates from right and left images captured by a stereo camera and provides users with reality through a virtual space operated by the 3-dimensional coordinates. In general, all pixels in correspondence region are compared for the disparity estimation. However, for a real time process, the central coordinates of the correspondence region are only used in the proposed algorithm. In the implemented system, 3D coordinates are obtained by using the depth information derived from the estimated disparity and we set user's hand as a region of interest(ROI). After user's hand is detected as the ROI, the system keeps tracking a hand's movement and generates a virtual space that is controled by the hand. Experimental results show that the implemented system could estimate the disparity in real -time and gave the mean-error less than 0.68cm within a range of distance, 1.5m. Also It had more than 90% accuracy in the hand recognition.

Predictive Factors of Postoperative Pain and Postoperative Anxiety in Children Undergoing Elective Circumcision: A Prospective Cohort Study

  • Zavras, Nick;Tsamoudaki, Stella;Ntomi, Vasileia;Yiannopoulos, Ioannis;Christianakis, Efstratios;Pikoulis, Emmanuel
    • The Korean Journal of Pain
    • /
    • v.28 no.4
    • /
    • pp.244-253
    • /
    • 2015
  • Background: Although circumcision for phimosis in children is a minor surgical procedure, it is followed by pain and carries the risk of increased postoperative anxiety. This study examined predictive factors of postoperative pain and anxiety in children undergoing circumcision. Methods: We conducted a prospective cohort study of children scheduled for elective circumcision. Circumcision was performed applying one of the following surgical techniques: sutureless prepuceplasty (SP), preputial plasty technique (PP), and conventional circumcision (CC). Demographics and base-line clinical characteristics were collected, and assessment of the level of preoperative anxiety was performed. Subsequently, a statistical model was designed in order to examine predictive factors of postoperative pain and postoperative anxiety. Assessment of postoperative pain was performed using the Faces Pain Scale (FPS). The Post Hospitalization Behavior Questionnaire study was used to assess negative behavioral manifestations. Results: A total of 301 children with a mean age of $7.56{\pm}2.61$ years were included in the study. Predictive factors of postoperative pain measured with the FPS included a) the type of surgical technique, b) the absence of siblings, and c) the presence of postoperative complications. Predictive factors of postoperative anxiety included a) the type of surgical technique, b) the level of education of mothers, c) the presence of preoperative anxiety, and d) a history of previous surgery. Conclusions: Although our study was not without its limitations, it expands current knowledge by adding new predictive factors of postoperative pain and postoperative anxiety. Clearly, further randomized controlled studies are needed to confirm its results.

DEVELOPMENT OF LANGMUIR AND ELECTRON PROBE FOR KSR-III (KSR-3 과학로켓용 전자환경 측정기 개발)

  • Hwang, S. H.;Kim, J.;Kim, J. K.;Lee, S. J.;Jang, Y. S.;Park, J. J.;Cho, G. R.;Won, Y. I
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.249-256
    • /
    • 2001
  • KARI(Ko.ea Aerospace Research Institute) has measured the ionospheric electron temperature and density over the Korean Peninsular with the Langmuir and Electron Probe(LEP) onboard the Korean Sounding Rocket-II(KSR-II) In 1998. The purpose of LEP is to measure the electron density and temperature profile in the ionosphere. LEP consists of the Langmuir probe(LP) and the Electron temperature Probe(ETP) which are widely used for the measurement of the ionospheric plazma environment . We discuss the development of the Langmuir and Electron Probe which will be onboard the KSR-III and some test results in a simulated space plasma environment with the plasma chamber at the ISAS in Japan. These measurements could contribute to the basic study of ionospheric environment which also can be compared with other reference models such as IRI and PIM.

  • PDF

Radiologic Assessment of Subsidence in Stand-Alone Cervical Polyetheretherketone (PEEK) Cage

  • Ha, Sung-Kon;Park, Jung-Yul;Kim, Se-Hoon;Lim, Dong-Jun;Kim, Sang-Dae;Lee, Sang-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.6
    • /
    • pp.370-374
    • /
    • 2008
  • Objective : Aim of study was to find a proper method for assessing subsidence using a radiologic measurement following anterior cervical discectomy and fusion (ACDF) with stand-alone polyetheretherketone (PEEK), $Solis^{TM}$ cage. Methods : Forty-two patients who underwent ACDF with $Solis^{TM}$ cage were selected. With a minimum follow-up of 6 months, the retrospective investigation was conducted for 37 levels in 32 patients. Mean follow-up period was 18.9 months. Total intervertebral height (TIH) of two fused vertebral bodies was measured on digital radiographs with built-in software. Degree of subsidence (${\Delta}TIH$) was reflected by the difference between the immediate postoperative and follow-up TIH. Change of postoperative disc space height (CT-MR ${\Delta}TIH$) was reflected by the difference between TIH of the preoperative mid-sagittal 2D CT and that of the preoperative mid-sagittal T1-weighted MRI. Results : Compared to preoperative findings, postoperative disc height was increased in all cases and subsidence was observed only in 3 cases. For comparison of subsidence and non-subsidence group, TIH and CT-MR ${\Delta}TIH$ of each group were analyzed. There was no statistically significant difference in TIH and CT-MR ${\Delta}TIH$ between each group at 4 and 8 weeks, but a difference was observed at the last follow-up TIH (p=0.0497). Conclusion : ACDF with $Solis^{TM}$ cage was associated with relatively good radiologic long-term results. Fusion was achieved in 94.5% and subsidence occurred in 8.1% by the radiologic assessment. Statistical analysis reveals that the subsidence seen later than 8 weeks after surgery and the development of subsidence does not correlate statistically with the change of the postoperative disc space height.

A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building (상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.

Pseudolite/Ultra-low-cost IMU Integrated Robust Indoor Navigation System Through Real-time Cycle Slip Detection and Compensation

  • Kim, Moon Ki;Kim, O-Jong;Kim, Youn Sil;Jeon, Sang Hoon;No, Hee Kwon;Shin, Beom Ju;Kim, Jung Beom;Kee, Changdon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.6 no.4
    • /
    • pp.181-194
    • /
    • 2017
  • In recent years, research has been actively conducted on the navigation in an indoor environment where Global Navigation Satellite System signals are unavailable. Among them, a study performed indoor navigation by integrating pseudolite carrier and Inertial Measurement Unit (IMU) sensor. However, in this case, there was no solution for the cycle slip occurring in the carrier. In another study, cycle slip detection and compensation were performed by integrating Global Positioning System (GPS) and IMU in an outdoor environment. However, in an indoor environment, cycle slip occurs more easily and frequently, and thus the occurrence of half cycle slip also increases. Accordingly, cycle slip detection based on 1 cycle unit has limitations. Therefore, in the present study, the aforementioned problems were resolved by performing indoor navigation through the integration of pseudolite and ultra-low-cost IMU embedded in a smartphone and by performing half cycle slip detection and compensation based on this. In addition, it was verified through the actual implementation of real-time navigation.

Three Dimensional In-situ Stress Distribution in the Southern Korean Peninsula and Its Application in Tunnel Analysis (한반도 3차원 지중응력의 분포와 이를 고려한 터널해석에 대한 연구)

  • 김동갑;박종관
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.65-74
    • /
    • 2002
  • The measurement of in-situ stress is essential to estimate the ground displacement and the stress distribution of a tunnel and an underground structure. In this study, the in-situ stress distribution of the Southern Korean peninsula was re-evaluated by the new 380 in-situ data which were determined by overcoring and hydrofracturing methods, and the three-din erosional numerical analysis of tunnelling was performed. The results of in-situ stress distribution show that the distribution of horizontal stress tends to be more irregular in metamorphosed(gneiss) and granite areas than in sedimentary and volcanic areas. The ratio of horizontal to vertical stresses(K-value) in volcanic area is less than 1 below the depth of 150m. The direction and magnitude of three dimensional in-situ stresses were shown simultaneously in a figure for the first time in Korea. The three-dimensional numerical analysis of tunnelling indicates that the orientation and magnitude of displacement around a tunnel are controlled mainly by the difference between the maximum and minimum horizontal stresses.