• 제목/요약/키워드: 2-D measurement

검색결과 3,175건 처리시간 0.035초

PSD sensor array design for the 3D measurement of moving objects (이동 물체의 3차원 계측을 위한 PSD 센서 배열 설계)

  • Kim, Jon-Man;Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • 제17권2호
    • /
    • pp.106-113
    • /
    • 2008
  • Perceiving a 3D moving target is important for automated machines including robots in a factory. Although stereovision or ultrasonic ranging is often employed for the purpose, the former requires high-cost systems, and the latter suffers from low-resolution. In this paper, we propose a PSD sensor array to acquire the 3D profile of an object conveyed by a belt. Rectangular parallelepiped target objects at random positions and orientations are assumed. Nine PSD sensors are configured in a $3{\times}3$ array above the belt, and fired in a sequence so that cross-talk can be avoided. Time gaps among sensor readings are compensated to get a result that is obtainable when sensors' measurements are made simultaneously along a sensing line. The system designed is tested with various objects in experiments.

The Measurement of Femoral Neck Anteversion by 3D Modeling of Femoral Major Axes (대퇴골 주요축의 3차원 모델링에 의한 전염각의 측정)

  • Kim, Jun-Sik;Kim, Seon-Il
    • Journal of Biomedical Engineering Research
    • /
    • 제19권4호
    • /
    • pp.341-350
    • /
    • 1998
  • The accurate measurement of the femoral anteversion is important for the derotational osteotomy. To estimate femoral anteversion, following three major parameters are required; the neck axis, the long axis, and the knee axis. Conventional methods on the basis of 2D images are ambiguous to determine these major axes. As the femur has a complex 3 dimensional structure, the 3 dimensional model should be applied for accurate and reliable measurement of femoral anteversion. In this thesis, we model femur and define three parameters. The neck axis is defined from the femoral head and neck model. The long axis is determined from the cylindrical model of the femoral shaft. The knee axis is also determined from the model of femoral condyles. According to the definition of the femoral anteversion, the femoral anteversion is efficiently estimated from these models. 20 specimens were tested by the conventional 2D imaging method and 3D imaging method witch was developed by authors and the new 3D modeling method. The study provides accurate, fast and human factor free measurement for femoral anteversion.

  • PDF

Performance Test on 2-Dimensional PIV and 3-Dimensional PIV Using Standard Images (표준영상을 이용한 2차원 PIV와 3차원 PIV 성능시험)

  • Hwang, Tae-Gyu;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제28권11호
    • /
    • pp.1315-1321
    • /
    • 2004
  • Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV(Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements test. It has been shown that the results obtained by 2D-PIV on average values are slightly closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV.

Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication (고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구)

  • 이재조;유정훈;홍충선;이대영
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • 제53권5호
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

Newly Designed HRTF Measurement System and its Analysis (머리전달함수 측정시스템의 개발과 분석)

  • Lee, Yun-Jae;Park, Young-Jin;Park, Youn-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제16권2호
    • /
    • pp.202-205
    • /
    • 2010
  • When we render 3D sound images using headphones or speakers, the main key of this technology is the Head-related transfer function (HRTF) database. Even though there are various HRTF databases, they have some drawbacks such as detrimental effects caused by imperfect measuring environment and insufficient measurement points. Moreover there is no database with Korean subjects. We are planning to develop the HRTF database for Korean. As a first step to establish the HRTF database aimed at Korean, the new HRTF measurement system with minimized aforementioned drawbacks is designed. In this paper, the newly designed HRTF measurement system is introduced and the overall effects caused by the diffraction of the apparatus, especially the headrest and backrest of the chair, are analyzed. The backrest of the chair does not distort the HRTFs significantly while the headrest makes significant distortion on the HRTFs and it could have significant effects on directional perception. We determined acceptable head rotation angle and head position of the subject for accurate HRTF measurement based on the experiments with B&K HATS. We conclude that the 3 degrees of the head rotation and the 1.5cm front/back/left/right shift of the head do not distort the HRTFs significantly.

Extracting Frequency-Frequency Correlation Function from Two-Dimensional Infrared Spectroscopy: Peak Shift Measurement

  • Kwak, Kyung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권10호
    • /
    • pp.3391-3396
    • /
    • 2012
  • Two-dimensional infrared (2D-IR) spectroscopy can probe the fast structural evolution of molecules under thermal equilibrium. Vibrational frequency fluctuation caused by structural evolution produced the time-dependent line shape change in 2D-IR spectrum. A variety of methods has been used to connect the evolution of 2D-IR spectrum with Frequency-Frequency Correlation Function (FFCF), which connects the experimental observables to a molecular level description. Here, a new method to extract FFCF from 2D-IR spectra is described. The experimental observable is the time-dependent frequency shift of maximum peak position in the slice spectrum of 2D-IR, which is taken along the excitation frequency axis. The direct relation between the 2D-IR peak shift and FFCF is proved analytically. Observing the 2D-IR peak shift does not need the full 2D-IR spectrum which covers 0-1 and 1-2 bands. Thus data collection time to determine FFCF can be reduced significantly, which helps the detection of transient species.

Impact of Health Insurance Type on the Quality of Hemodialysis Services: A Multilevel Analysis (의료보장 형태가 혈액투석 서비스 제공에 미치는 영향에 대한 다수준 분석)

  • Jung, Jin-Hee;Kwon, Soon-Man;Kim, Kyoung-Hoon;Lee, Seon-Kyoung;Kim, Dong-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • 제43권3호
    • /
    • pp.245-256
    • /
    • 2010
  • Objectives: This study aims to compare quality indicators for the hemodialysis services between patients with health insurance and those with medical aid. Methods: This study used data from sampled hospitals that provided a hemodialysis service. A total of 2287 patients were selected, and the information for hemodialysis service has been granted from medical record reviews. A multi-level regression analysis was used to examine the differences in process and outcome indicators for hemodialysis between patients with health insurance and those with medical aid. Process indicators were defined as: frequency of hemodialysis, hemodialysis time, erythropoietin (EPO) use, measurement of hemodialysis dose at least once a month, measurement of phosphate at least once every three months, and measurement of albumin at least once every three months. Outcome indicators were defined as: hemodialysis adequacy, anemia management, blood pressure management, and calcium, phosphate and nutrition management. The total scores for outcome indicators ranged from 0 (worst) to 4 (best). Results: There was a significant difference in the measurement of hemodialysis dose at least once a month between patients with health insurance and those with medical aid (OR 0.66, 95% CI = 0.43 - 0.99). However, frequency of hemodialysis, hemodialysis time, EPO use, measurement of phosphate at least once every three months, measurement of albumin at least once every three months, hemodialysis adequacy management, Hb${\geq}$11 g/dL, blood pressure within the range of 100-140 /60-90 mmHg, calcium x phosphate${\leq}$55 $g^2/dL^2$ and albumin${\geq}$4 g/dL were not significantly different between the groups. Conclusions: There were no significant differences in outcome indicators for hemodialysis between the groups. Further studies are warranted into the mechanism that results in no differences in the outcome indicators for hemodialysis.

Measurement uncertainty in heavy-weight floor impact sounds (측정 불확도에 따른 중량충격음 측정편차에 관한 연구)

  • Yoo, Seung-Yup;Kim, Yong-Hee;Sim, Myoung-Hee;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.826-829
    • /
    • 2008
  • In a field measurement, measurement errors are produced by measuring environments and systematic errors in the measurement procedure. Measurement errors can be expressed as a measurement uncertainty. In this study, the measurement uncertainty and various measuring factors are investigated in heavy-weight impact sounds. According to KS 2810-2, the model functions, which is the estimation of the maximum SPL measurement in each octave band frequency, are determined. From this estimation model, 3.53dB is shown in 63Hz. This level is caused by the sound field of the receiving room, which does not meet the diffusing field.

  • PDF

An experimental study of a flow field generated by a rotating cylinder on a plane moving at free stream velocity (자유흐름 속도의 이동면과 맞닿은 회전실린더 주위 유동장의 실험적 해석)

  • Park, Un-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제21권5호
    • /
    • pp.700-712
    • /
    • 1997
  • The flowfield generated by a 2-D rotating cylinder on a plane moving at freestream velocity was experimentally investigated in a wind tunnel to simulate aerodynamic characteristics of rotating wheels of an automobile. In the flowfield around a rotating cylinder at 3*10$^{3}$ < Re$_{d}$<8*10$^{3}$, unique mean flow and turbulence characteristics were confirmed by hot-wire measurements as well as frequency analysis, which was supported by flow visualization. In the vicinity of a rotating cylinder, a unique turbulence structure on .root.over bar u'$^{2}$ profiles was formed in hump-like shape at 1 < y/d < 3. A peak frequency which characterized the effect of a rotating cylinder had the same value of the rotation rate of a cylinder. In case of cylinder rotation, the depths of mean velocity -defect and turbulent-shear regions were thickened by 20-40% at 0 < x/d < 10 compared with the case of cylinder stationary. Far downstream beyond x/d > 10, the flowfield generated by a rotating cylinder showed self-similarity in the profiles of mean velocity and turbulence quantities. The effect of a rotating cylinder was independent of its rotation rate and Reynolds number in the measurement range.

A Study on the Standardization In the Mandibular First Premolar of the Middle Aged Korean (하악 제1소구치의 표준화 연구)

  • Lee H.J.;Chun K.J.;Chung D.T.;Cho C.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.252-255
    • /
    • 2005
  • Mandibular first premolars obtained from the middle-aged men about the ages of 50 were scanned using a Micro-CT. A Jig was made for a Micro-CT measurement to get reliable data from irregular teeth shape. Data were measured from the scanned 2-D images by way of measurement software. the methodology fer measurement of the mandibular first premolar was presented and according to this, the standardized mandibular first premolars of middle aged Korean males and females were made by using a rapid prototyping system.

  • PDF