• Title/Summary/Keyword: 2-D analysis

Search Result 15,492, Processing Time 0.056 seconds

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.

Discrimination of Geographical Origin for Astragalus Root (Astragalus membranaceus) by Capillary Electrophoresis and Near-Infrared Spectroscopy (Capillary electrophoresis 및 근적외선분광분석기를 이용한 황기의 원산지 판별)

  • Kim, Eun-Young;Kim, Jung-Hyun;Lee, Nam-Yun;Kim, Soo-Jeong;Rhyu, Mee-Ra
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.818-824
    • /
    • 2003
  • Capillary electrophoresis (CE) and near-infrared spectroscopy (NIRS) were performed to discriminate astragalus roots (Astragalus membranaceus) according to geographical origin (domestic or foreign). Two-hundred-and-four astragalus roots were extracted with 30% methanol in 0.1 M phosphate buffer (pH 2.5) and separated in a uncoated fused-silica $(50\;{\mu}m{\times}27\;cm)$ capillary. Conditions for optimal analysis included: temperature $-45^{\circ}C$, voltage -14 kV, and pressure injection time -8 sec. The optimal separation buffer was 0.1 M phosphate buffer (pH 2.5) containing 40 mM hexane sulfonic acid with 20% 2-methoxy ethanol. Raw NIR spectra were obtained using NIRS, and modified partial least square regression was used to develop the prediction model. The correlation coefficient and standard error of prediction were 0.915 and 14.3%, respectively. Under the optimal conditions established for CE and NIRS, the geographical origins of the astragalus roots were correctly identified in 80 and 97%, respectively. Astragalus roots that were not discriminated by NIRS were correctly discriminated by CE. Hence, CE and NIRS are potential methods for discriminating the geographical origins of astragalus roots that complement one another.

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

Purification of Thiazole- and Pyrazine-inducible Microsomal Epoxide Hydrolase: Induction of Epoxide Hydrolase-related Novel 43 kDa Protein (Thiazole 또는 Pyrazine유도성 Microsomal Epoxide Hydrolase의 순수정제: Epoxide Hydrolase-관련성 43 kDa 단백질의 유도증가)

  • Kim, Sang-Geon
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.2
    • /
    • pp.275-282
    • /
    • 1993
  • Liver microsomal epoxide hydrolase (mEH) is active in the detoxification of epoxide-containing reactive intermediate. Previous studies in this laboratory have shown that thiazole and pyrazine are efficacious inducers of mEH in rats with large increases in mEH mRNA levels (Carcinogensis, Kim et al, 1993). mEH was purified to electrophoretic homogeneity from thiazole-induced rat hepatic microsomes using DEAE-cellulose column chromatography whereas another protein $({\sim}43\;kDa)$ was co-purified with mEH from pyrazine-induced rat hepatic micrsomes (200 mg/kg body weight/day, ip, 3d). The antibody raised from a rabbit against mEH protein purified from thiazole-induced rat hepatic microsomes appeared to specifically recognize mEH protein in rat hepatic microsomes, as assessed by immunoblotting analysis. Immunoblotting analyses revealed a 10- and 7-fold increase in mEH levels in the hepatic microsomes isolated from thiazole- and pyrazine-treated rats, respectively. Moreover, immunoblotting analysis showed cross-reactivity of the mEH antibody with a 43 kDa protein in pyrazine-induced rat hepatic microsomes and with co-purified 43 kDa protein in purified fractions. The ratio between the 43 kDa protein and mEH in pyrazine-induced rat microsomes or in purified fractions was ${\sim}1$ to 15. N-terminal amino acid sequence analysis of both purified rat mEH and 43 kDa protein revealed that 10 out of 12 amino acids in N-terminus of the 43 kDa protein were identical with the mEH sequence with two amino acid residues of the 43 kDa protein undetermined. Either thiazole or pyrazine treatment, however, failed to increase the levels of mEH protein in rabbits while pyrazine caused elevation of the 43 kDa protein in this species, as determined by irnrnunoblotting analysis. These results demonstrated that treatment of rats with either thiazole or pyrazine causes elevation in hepatic mEH expiession whereas pyrazine treatment results in induction of another mEH-related 43 kDa protein and that a distinct species difference exists between rats and rabbits in the induction of mEH by these xenobiotics.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.

Long-term Clinical Outcomes after Primary Percutaneous Coronary Intervention in Patients with Acute Myocardial Infarction-on the basis of 65 Years (급성 심근경색증 환자에서 일차적 관상동맥 중재술 후 장기적 임상 경과-65세를 기준으로)

  • Lee, Han-Ol;Jang, Seong-Joo;Kim, In-Soo;Han, Jae-Bok;Park, Soo-Hwan;Kim, Jeong-Hun;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.251-261
    • /
    • 2014
  • Primary percutaneous coronary intervention (PCI) has been found to be superior, in terms of hospital mortality and long-term outcome, compared with thrombolytic therapy in patients with acute myocardial infarction (AMI). However, the clinical benefits of primary PCI have not been precisely evaluated in elderly patients.1,974 patients (Group I: n=1,018, $age{\geq}65years$, $73.8{\pm}5.99years$; Group II: n=956, age<65years, $52.8{\pm}7.96years$) who underwent primary PCI for AMI at Chonnam National University Hospital between 2006 and 2010 were analyzed according to their clinical, angiographic characteristics for hospital and one-year survival. Group I had a higher percentage of women, diabetes mellitus, hypertension, multi-vessel disease and lower prevalence of current smoking, hyperlipidemia, familial history than Group II. Culprit lesions were at the left anterior descending artery, left circumflex artery, right coronary artery and left main artery in 42.8% vs. 45.0%, 34.1% vs. 29.6%, 14.6% vs 14.6, 2.7% vs. 1.6%, respectively (p=0.007). Stent diameter was smaller in group I ($3.17{\pm}0.39$ vs. $3.29{\pm}0.42mm$, p=0.001). In-hospital mortality was higher in group I (8.4 vs. 1.9%, p<0.001). There were significant differences in the rates of major adverse cardiac events between the two groups during one-year clinical follow-up (20.1 vs.14.0%, p<0.001). On multiple logistic regression analysis, systolic blood pressure<100mmHg, serum $creatinine{\geq}1.3mg/dL$, Killip class> I, multivessel disease, left ventricular ejection fraction <40% and cerebro vascular disease were independent predictors of one-year motality in patients over 65 years after PCI.

Impact of Compositions and Concentrations of Fertilizer Solution on Growth of Lettuce and Changes in Chemical Properties of Root Media (관비용액의 비료 조성 및 농도가 상추의 생장과 근권 환경 변화에 미치는 영향)

  • Shin, Bo Kyuong;Son, Jung Eek;Choi, Jong Myung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.193-201
    • /
    • 2013
  • This research was conducted to investigate the influence of compositions and concentrations of fertilizer solution on growth of lettuce as well as changes in chemical properties of root media. To achieve this three kinds of fertilizers such as acidic (AF), neutral (NF), and alkaline fertilizer (BF) were formulated and applied with the concentrations of 100 or $200mg{\cdot}L^{-1}$ based on nitrogen concentrations. The growth characteristics were investigated 10 weeks after transplant and the analysis of soil solution for chemical characteristics were conducted in every week. The BF was more effective than AF in crop growth of blue leaf lettuce 10 weeks after transplant and the treatment of BF200 showed the heaviest fresh and dry weights among all treatments tested. The treatment of BF also showed the highest growth followed by those of NF and AF in growth of red leaf lettuce, but the growth in treatments of $100mg{\cdot}L^{-1}$ were higher than those of $200mg{\cdot}L^{-1}$ in the three kinds of fertilizers. The differences among treatments in soil solution pH became larger from week 6. The pH in the treatment of $200mg{\cdot}L^{-1}$ was lower than that of $100mg{\cdot}L^{-1}$ when AF was applied, but the treatment of $200mg{\cdot}L^{-1}$ showed higher pH than that of $100mg{\cdot}L^{-1}$ in case of BF. The electrical conductivity of soil solution in treatments of $200mg{\cdot}L^{-1}$ were 0.2 to 0.4 unit higher than those of $100mg{\cdot}L^{-1}$ when those are measured as $dS{\cdot}m^{-1}$ in three kinds of fertilizers. The $NH_4$ concentrations were higher in the treatments of AF than those of BF, but the concentrations of Ca, Mg and $NO_3$ were vice verse. The concentrations of $PO_4^{-3}$ were the highest in the treatments of AF followed by those of NF and BF when three kinds of fertilizers were applied with equal nitrogen concentrations. The differences of nutrient concentrations in soil solution of root media were influenced by composition of fertigation solution and varied soil solution pH.

Development of the Perceived Stress Response Inventory (스트레스반응 지각척도의 개발)

  • Koh, Kyung-Bong;Park, Joong-Kyu;Kim, Chan-Hyung
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.7 no.1
    • /
    • pp.26-41
    • /
    • 1999
  • The perceived stress response inventory(PSRI) was developed to measure 4 types of current stress responses : emotional, somatic, cognitive, and behavioral responses. 242 patients with psychiatric disorders(71 patients with anxiety disorders, 73 patients with depressive disorders, 47 patients with somatoform disorders, 51 patients with psychosomatic disorders) and 215 healthy subjects completed the questionnaire including the PSRI. Global assessment of recent stress(GARS) scale, perceived stress questionnaire(PSQ) and symptom checklist-90-revised(SCL-90-R) were also administered at the same time. Factor analysis for each of 4 types of stress responses yielded 8 factors : negative emotional responses, general somatic symptoms, specific somatic symptoms, lowered cognitive function and general negative thinking, self-depreciative thinking, impulsive-aggressive thinking, passive-responsive and careless behavior, and impulsive-aggressive behavior. Both test-restest reliability(r= .83 -.93) and internal consistency(Cronbach's alpha : .79 -.96 for each of 8 subscales and .98 for total items of the scale) were all at statistically significant levels. Total scores of the PSRI significantly correlated with total scores of GARS scale, PSQ, and global indicies of SCL-90-R, respectively. The patient group had significantly higher scores than healthy subjects in each of all the subscales except impulsive-aggressive behavior subscale. These results suggest that the PSRI is a reliable and valid tool stable over time which may be effectively used for the research in stress-related field including psychosomatic medicine.

  • PDF

Study on Strain Measurement of Agricultural Machine Elements Using Microcomputer (Microcomputer를 이용(利用)한 농업기계요소(農業機械要素)의 Strain 측정(測定)에 관(關)한 연구(硏究))

  • Kim, Kee Dae;Kim, Tae Kyun;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.8 no.1
    • /
    • pp.90-96
    • /
    • 1981
  • To design more efficient agricultural machinery, the accurately measuring system among many other factors is essential. A light-beam oscillographic recorder is generally used in measuring dynamic strain but it is not compatible with the extremely high speed measuring system such as 1,000 m/s, also is susceptable to damage due to vibration while using the system in field. The recorder used light sensitive paper for strip chart recording. The reading and analysis of data from the strip charts is very cumbersome, errorneous and time consuming. A microcomputer was interfaced with A/D converter, microcomputer program was developed for measuring, system calibration was done and the strain generated from a cantilever beam vibrator was measured. The results are summarized as follows. 1. Microcomputer program was developed to perform strain measuring of agricultural machine elements and could be controled freely the measuring intervals, no. of channels and no. of data. The maximum measuring speed was $62{\mu}s$. 2. Calibration the system was performed with triangle wave generated from a function generator and checked by an oscilloscope. The sampled data were processed using HP 3000 minicomputer of Chungnam National University computer center the graphical results were triangle same as input wave and so the system have been out of phase distorsion and amplitude distorsion. 3. The strain generated from a cantilever beam vibrator which has free vibration period of 0.019 second were measured by the system controlled to have l.0 ms of time interval and its computer output showing vibration curve which is well filted to theoretical value. 4. Using microcomputer on measuring the strain of agricultural machine elements could not only save analyzing time and recording papers but also get excellent adaptation to field experiment, especially in measurement requiring high speed and good precision.

  • PDF