• Title/Summary/Keyword: 2-D PIV

Search Result 153, Processing Time 0.022 seconds

A Study on Ventilation Characteristics of LNG Carrier Hood room by PIV and CFD (PIV와 CFD에 의한 LNG선박의 Hood room 환기특성에 관한 연구)

  • Cho, D.H.;Kim, D.C.;Kim, M.E.;Lee, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.673-679
    • /
    • 2000
  • LNG Carriers are currently known as sole commercial means of shipping natural gas on the sea. They are designed to proven dangerous explosion for shipping a lot of gas over long distance. In this study. In this study, a scaled model chamber was made to investigate ventilation characteristics of the hood room in LNG carrier. Experimental study was performed in model using visualization equipments with laser apparatus and image intensifier CCD camera gated by an AOM controller Twelve different kinds of measuring area were selected as experimental condition. Instant simultaneous velocity vectors at whole field were measured by using 2-D PIV system which software adopts two-frame grey-level cross correlation algorithm. To look into stagnation area of hood room for LNG carrier, a three-dimensional numerical simulation with standard ${\kappa}-{\varepsilon}$ model was carried out by using PHOENICS for three kinds of Reynolds number, $6.5{\times}10^3$, $9.7{\times}10^3\;and\;1.29{\times}10^4$, based on the cavity inlet velocity and cavity height. The flow pattern showed the large scale counter-clockwise forced-vortex rotated at center area, small eddies at each corner and stagnation area located at left-back upper side of model.

  • PDF

A Study on Flow Structure of Breaking Wave through PIV Analysis (PIV기법을 활용한 쇄파의 유동구조 해석)

  • Jo, Hyo-Jae;Lee, Eon-Ju;Doh, Deog-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.43-47
    • /
    • 2009
  • This paper compares theoretical wave profile and particle kinematics with experimental results generated by a 2 D wave tank. Particle velocity fields of compound waves were acquired using a PIV technique. Synchronization was applied to acquire images of the wave fields, and the time gap between these images was controlled by the user. This technique was applied to investigate the wave breaking mechanism, and the wave profile and velocity distribution in a wave breaking field was obtained.

Experimental Study on Turbulent Structure of Flow over a Micro Riblet Plate (미세 Riblet 평판에서의 난류구조 변화에 관한 실험적 연구)

  • Choi, Yong-Seok;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.375-376
    • /
    • 2006
  • Turbulent structure of a boundary-layer over a flat plate coated with micro riblet film(MRF) has been investigated experimentally. The turbulent structure was visualized using a dynamic particle image velocimetry (Dynamic PIV) system. We identified the vortex structures from 2-D velocity field data by applying the complex eigenvalue definition. The velocity field images acquired by using the complex eigenvalue definition showed the whole 2-D vortex structures clearly. In addition, the spatial distributions of small-scale vortices as well as large-scale vortices were obtained with high accuracy. The difference of vortex structures between the MRF coated flat plate and the smooth flat plate was analysed in detail. With varying upstream flow speed, the characteristics of vortex structure over the MRF coated flate plate was compared with those over the smooth flat plate.

  • PDF

Experimental Study on Flow Characteristics of ERF Between Two Parallel-Plate Electrodes by using PIV Technique (평행평판 전극사이에서 PIV 기법을 이용한 ER 유체의 유동특성에 관한 실험적 연구)

  • Chang Tae-Hyun;Chang Ki-Won
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.103-106
    • /
    • 2003
  • An experimental investigation was peformed to study the characteristics of ER(Electro-Rheological) fluid water flow in a horizontal rectangular tube with or without D.C volatage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0 kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the claster of ERF are clearly strong along the test tube and the flow rate decreased.

  • PDF

Experimental Study on Flow Characteristics of ERF by using PIV Technique (PIV 기법을 이용한 ER 유체의 유동특성에 관한 실험적 연구)

  • 장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.116-123
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of ER (Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C volatage. To determine some characteristics of the ER flow. 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0 kV/mm. 1.0kV/mm and 1 5kV/mm for Re=0, 0.62, 1.29 and 2.26. When the strength of the electric field increased. the claster of ERF are clearly strong along the test tube and the flow rate decreased.

PIV System for the Flow Pattern Anaysis of Artificial Organs ; Applied to the In Vitro Test of Artificial Heart Valves

  • Lee, Dong-Hyeok;Seh, Soo-Won;An, Hyuk;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.489-497
    • /
    • 1994
  • The most serious problems related to the cardiovascular prothesis are thrombosis and hemolysis. It is known that the flow pattern of cardiovascular prostheses is highly correlated with thrombosis and hemolysis. Laser Doppler Anemometry (LDA) is a usual method to get flow pattern, which is difficult to operate and has narrow measure region. Particle Image Velocimetry (PIV) can solve these problems. Because the flow speed of valve is too high to catch particles by CCD camera, high-speed camera (Hyspeed : Holland-Photonics) was used. The estimated maximum flow speed was 5m/sec and maximum trackable length is 0.5 cm, so the shutter speed was determined as 1000 frames per sec. Several image processing techniques (blurring, segmentation, morphology, etc) were used for the preprocessing. Particle tracking algorithm and 2-D interpolation technique which were necessary in making gridrized velocity pronto, were applied to this PIV program. By using Single-Pulse Multi-Frame particle tracking algorithm, some problems of PIV can be solved. To eliminate particles which penetrate the sheeted plane and to determine the direction of particle paths are these solving methods. 1-D relaxation fomula is modified to interpolate 2-D field. Parachute artificial heart valve which was developed by Seoul National University and Bjork-Shiely valve was testified. For each valve, different flow pattern, velocity profile, wall shear stress and mean velocity were obtained.

  • PDF

PIV measurement of step cavity with driven flow (구동류를 갖는 계단 캐비티의 PIV계측)

  • 조대환;김진구;이영호
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • An experimental study was carried out in a three-dimensional cubic cavity driven by 2-dimensional plane Poiseuille flow for three kinds of Reynolds number, $10^4$, 3 $\times$ $10^4$ and 5 $\times$ $10^4$ based on the cavity width and cavity inlet mean flow velcoity. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system. Laser based illumination and two-frame grey-level cross correlation algorithm are adopted. Severe unsteady flow fluctuation within the cavity are remarkable at above Re = 3 $\times$ $10^4$ Reynolds numbers and sheared mixing layer phenomena are also found at the region where inlet driving Poiseuille flow is collided with the clock-wise rotating main primary vortex at upper center area. Instant velocity profiles reveal that deformed forced vortex formation is observed throughout the separate two areas.

  • PDF

Papers : A Study on the Characteristics of the Ramjet Engine Combustor using a Two Color PIV Technique (논문 : Two Color PIV 기법을 이용한 램제트엔진 연소기 특성에 대한 연구)

  • An,Gyu-Bok;Yun,Yeong-Bin;Jeong,In-Seok;Heo,Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • A two color PIV technique has been developed for visualization of complex and high speed flow in a ramjet combustor. Two color PIV has the advantages that velocity distribytions in high speed flowfields can be measured simply by varying the time interval between two different laser beams and a directional ambiguity problem can be solved by color separation, and then a singnal-to-noise ratio can be increased through nearly perfect cross-correlation. As a basic research of the ramjet engine, a 2-D shaped combustor with two symmetric air intakes has been manufactured and an experimental study has been conducted using a two color PIV technique. The flow characteristics such as recirculation zones and two intake air mixing have been investigated varying inlet angles and dome heights. It is found that the size and air mass ratio of reciculation zones are affected mainly by an inlet angle, but not much by a dome height.

Flow control on the near wake of a circular cylinder attached with control rods (제어봉 부착에 따른 원형실린더 근접 후류 유동제어에 관한 실험적 연구)

  • Gim, Ok-Sok;Lee, Gyoung-Woo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.453-458
    • /
    • 2008
  • Flow characteristics of the control-rod-attached 2-dimensional circular cylinder was accomplished using by PIV techniques. model tests had been carried out with different diameters of control rods(d/D=0.1 through d/D=0.5). and the Reynolds number Re=15,000 based on the cylinder diameter(D=50mm) to predict the performance of the model and the two-frame grey-level cross-correlation method had been used to obtain the velocity distribution in the flow field. 50mm circular cylinder had been used during the whole experiments and measured results had been compared with each other. The measured results have been compared with each case. therefore this article identifies not only the mean velocity profiles but also the control effects of the control rods.

PIV Analysis of the Flow Inside a Home Refrigerator and the Design of a Higher Efficiency Cooling Duct (PIV 계측을 이용한 가정용 냉장고의 냉기 유동특성 파악과 고효율 냉기 유로 설계)

  • Choi, Jay-Ho;Cho, Sung-Ho;Nam, Young-Sok;Lee, In-Seop
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.405-409
    • /
    • 2001
  • An experimental analysis of the flow inside the refrigeration compartment of a home refrigerator was conducted in order to achieve better performances in terms of uniform temperature distribution and cooling speed. 2D PIV and stereoscopic PIV were used for the experiments on an actual-size refrigerator at operating conditions. Two CCD cameras were employed for a wider field of view in the measurement of the shelf, and stereoscopic PIV was used to measure the three velocity components at the various cooling duct outlets and the mean velocity fields were area-integrated to calculate the flow-rates. 50 to 100 instantaneous velocity fields were time averaged for the mean velocity fields. With the result of this analysis, a new cooling duct system was developed, with the refrigerator's cooling performance increasing 11% in terms of cooling speed, and 25% in temperature uniformity.

  • PDF