• Title/Summary/Keyword: 2-D PIV

Search Result 153, Processing Time 0.02 seconds

Three Dimensional Vortex Behavior of LEX Delta Wing by Dynamic Stereo PIV (Dynamic Stereo PIV에 의한 델타형 날개에서의 3차원 와류 유동에 관한 연구)

  • Lee Hyun;Kim Mi-Young;Choi Jang-Woon;Choi Min-Seon;Lee Young-Ho
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.39-42
    • /
    • 2003
  • Leading edge extension(LEX) in a highly swept shape applied to a delta wing features the modern air-fighters. The LEX vortices generated upon the upper surface of the wing at high angle of attack enhance the lift force of the delta wing by way of increased negative suction pressure over the surfaces. The present 3-D stereo PIV includes the Identification of 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criterion and so on. A delta wing model with or without LEX was immersed in a circulating water channel. Two high-resolution, high-speed digital cameras$(1280pixel\times1024pixel)$ were used to allow the time-resolved animation work. The present dynamic stereo PIV represents the complicated vortex behavior, especially, in terms of time-dependent characteristics of the vortices at given measuring sections. Quantities such as three velocity vector components, vorticity and other flow information can be easily visualized via the 3D time-resolved post-processing to make the easy understanding of the LEX effect or vortex emerging and collapse which are important phenomena occurring in the field of delta wing aerodynamics.

  • PDF

Flow Analysis on Near Field of Elliptic Jet Using a Single-Frame PIV (고해상도 PIV 기법을 이용한 타원형 제트의 근접 유동장 해석)

  • Shin, Dae-Sig;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.459-466
    • /
    • 2000
  • Flow characteristics of turbulent elliptic jets were experimentally investigated using a single-frame PIV system. A sharp-edged elliptic nozzle with aspect ratio(AR) of 2 was tested and the experimental results were compared with those of circular jet having the same equivalent diameter($D_e$). The Reynolds number based on the nozzle exit velocity and nozzle equivalent diameter was about $1{\times}10^4$. The spreading rate along the major and minor axis are different remarkably. The jet half width along the major axis decreases at first and then increases with going downstream. But along the minor axis the jet width increases steadily. The elliptic jet of AR=2 has one switching points at $X/D_e=2$ within the near field. Turbulence properties are also found to be significantly different along the major and minor axis planes.

An Analysis of 2-D Bluff Bodies Flows by Multi-Vision PIV (Multi-Vision PIV에 의한 2차원 단순물체의 유동장 해석)

  • Song, K.T.;Lee, H.;Kim, Y.T.;Lee, Y.H.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.573-580
    • /
    • 2002
  • Animation and time-resolved analysis of the wake characteristics of 2-D bluff body flows were examinated by applying the multi-vision PIV to square cylinders(three angles of attack: $0^{circ}, 30^{circ} and 45^{\circ}$) and circular cylinders(three rotating speeds: 0rpm, 76rpm, 153rpm) submerged within a circulating water channel $(Re=10^4)$, The macroscopic shedding patterns and their dominant frequencies were discussed in terms of instantaneous velocity, vorticity and turbulent quantities such as turbulent intensity, turbulent kinetic energy and three Reynolds stresses. Particularly the time-averaged distribution of turbulent intensity 'islands' where their peak magnitudes were focused always small regions behind the bodies without noticeable spatial migration were particularly discovered in all cases. And the dominant frequencies of the turbulent quantities in the wake regions were two times larger than those of the velocity and vorticity.

Application of Holographic Interferometry and 2-D PIV for HSC Convective Flow Diagnostics (Hele-Shaw Cell 내부의 열유동 해석을 위한 홀로그래픽 간섭계와 2차원 PIV의 적용)

  • Kim, Seok;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.682-687
    • /
    • 2003
  • The variations of temperature and velocity fields in a Hele-Shaw convection cell (HSC) were investigated using a holographic interferometry and 2-D PIV system with varying Rayleigh number. To measure quasisteady changes of temperature field, two different measurement methods of holographic interferometry; double-exposure method and real-time method, were employed. In the double-exposure method, unwanted waves can be eliminated effectively using digital image processing technique and the reconstruction images are clear, but transient flow structure cannot be reconstructed clearly. On the other hand, transient convective flow can be reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noises, compared with the double-exposure method. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow structure at high Rayleigh numbers. The periodic flow pattern at high Rayleigh numbers obtained by the real-time holographic interferometer method is in a good agreement with the PIV results.

  • PDF

A Study on Flow Characteristics of ERF Between Two Parallel-Plate by Using PlV (평형평판 간극사이에서 PIV를 이용한 ER유체의 유동특성에 관한연구)

  • Jung Wan-Bo;Park Young-Seuk
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2006
  • An experimental investigation was performed to study the characteristics of ER(Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C voltage. To determine some characteristics of the ER flow, 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0kV/mm, 1.0kV/mm and 1.5kV/mm for Re = 0, 0.62, 1.29 and 2.26. When the strength of the electric field increased, the cluster of ERF are clearly strong along the test tube and the flow rate decreased. In this study, the rheology of ER fluid stagnating or flowing through a dispersion meter will be investigated by PIV method. And then the ER effect, which appears at the ER valves and their appliance will be visualized.

Development of Hybrid Micro/Nano PIV system (하이브리드 마이크로/나노 PIV 시스템 개발)

  • Min, Young-Uk;Lee, Dong-Yeop;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.31-37
    • /
    • 2010
  • In this study, a novel hybrid micro/nano PIV system combining defocusing and TIRFM technique has been developed for the multiscale flow measurement. With the developed system, both far and near field velocity fields have been measured simultaneously in a 2D straight microchannel and the particle trajectories were extracted by the nearest tracking algorithm. The shear rate values taken from experimental results have been estimated by comparing with the analytical solution of 2D Poiseuille flow and it is confirmed that the result shows good agreement with the theoretical value.

The Visualization of the Flowfield around Three Circular Cylinders in the Tandem Arrangement by the PIV (PIV에 의한 직렬배열 상태에 놓인 3원주 주위의 유동장 가시화)

  • Ro, Ki-Deok;Jang, Dong-Hyu;Bae, Hung-Sub;Kim, Won-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.264-270
    • /
    • 2011
  • The Characteristics of the flowfield around three circular cylinders in tandem arrangement was investigated by PIV. Strouhal numbers, vorticity, velocity vectors and velocity profiles were observed at centre-to-centre space ratios of P/D=1.25~3.75, and Reynolds number of Re=$3.0{\times}10^3{\sim}5.0{\times}10^3$. As the results the Strouhal numbers measured in the rear region of 3rd the cylinder were distinguished three kind of regions with the space ratios and The flow pattern in the wake of each cylinder was different according to these regions. The time averaged flow at region of each cylinder was almost stagnated and the size of the stagnated region was small in order of 1st, 2nd and 3rd cylinder. The direction of vortex at the front and rear region of 2nd cylinder was opposed each other with the small difference(${\alpha}= {\pm}5^{\circ}$) of the attack angle ${\alpha}$.

Development of 3-D Stereo PIV and Its Application to a Delta Wing

  • Kim, Beom-Seok;Lee, Hyun;Choi, Jang-Woon;Kadooka, Yoshimasa;Tago, Yoshio;Lee, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.658-663
    • /
    • 2003
  • A process of 3-D stereo particle image velocimetry(PIV)was developed for the measurement of an illuminated sliced section field of 3-D complex flows. The present method includes modeling of camera by a calibrator based on the homogeneous coordinate system, transformation of the oblique-angled image to the right-angled image, identification of 2-D velocity vectors by 2-D cross-correlation equation, stereo matching of 2-D velocity vectors of two cameras, accurate calculation of 3-D velocity vectors by homogeneous coordinate system, removal of error vectors by a statistical method followed by a continuity equation criteria, and finally 3-D display as the post processing. An experimental system was also used for the application of the proposed method. Two high speed digital CCD cameras and an Argon-Ion Laser for the illumination were adopted to clarify the time-dependent characteristics of the leading edge extension(LEX) in a highly swept shape applied to a delta wing found in modern air-fighters.

  • PDF

Dual-plane Stereoscopic PIV Measurement on the Lobed Jet Mixing Flow

  • SAGA Tetsuo;KOBAYASHI Toshio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.108-122
    • /
    • 2001
  • In a continuing effect to study the mixmg enhancement by large-scale streamwise vortices in lobed mixing flows, an advanced PIV system named as dual-plane stereoscopic PIV system was used in the present study to conduct simultaneous vorticity (all three components) measurement of an air jet exhausted from a lobed nozzle. Unlike 'classical' 2-D PIV system or conventional 'single-plane' stereoscopic PIV system, the dual-plane stereoscopic PIV system used in the present study can obtain the flow velocity (all three components) fields at two spatially separated planes simultaneously. Therefore, it can provide the distributions of all the three components of vorticity vectors instantaneously and simultaneously. The evolution and interaction characteristics of the large-scale streamwise vortices and azimuthal Kelvin-Helmholtz vortices in the lobed jet mixing flow were revealed instantaneously and quantitatively from the measurement results of the dual-plane stereoscopic PIV system. The characteristics of the mixing process in the lobed jet mixing flow were analyzed based on the simultaneous measurement results of the steamwise vorticity and azimuthal Kelvin-Helmholtz vorticity distributions.

  • PDF

A Study on PIV Measurement of Unsteady Flow around Disk caused by Slide Type Valve Quick Closing (슬라이드 밸브 급폐쇄에 따른 디스크 주위 비정상유동의 PIV계측에 관한 연구)

  • Lee, Chul-Jae;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.251-256
    • /
    • 2009
  • In this research, we experimentally studied flow characteristic by applying PIV measuring techniques which could measure the point velocity of all flow field and measuring the unsteady velocity of surrounding disk generated in a short time. Time range of great velocity change following quick closing of the slide valve was within 0.1s and the cycle was presumed to be 0.12s as a result of comparison study between the result of point flow field and of existing pressure change. Also, surrounding disk flow inside the circular pipe was closed from the upper part and flow road was getting narrow and advanced to the lower part incidentally quickly there was a tendency that the size of the flow back velocity to the upper part immeadiately after the closure decreased to 4/120s and increased again. There was flow back velocity component in y/D=0.2 lower part by the influence of flow back to the upper part after complete closure and the vortex flow of 0.2D-size near y/D=0.7, x/D=-0.3 was observed.

  • PDF