Use of a gesture user interface as a touchless image navigation system in dental surgery: Case series report

  • Rosa, Guillermo M.;Elizondo, Maria L.
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.155-160
    • /
    • 2014
  • Purpose: The purposes of this study were to develop a workstation computer that allowed intraoperative touchless control of diagnostic and surgical images by a surgeon, and to report the preliminary experience with the use of the system in a series of cases in which dental surgery was performed. Materials and Methods: A custom workstation with a new motion sensing input device (Leap Motion) was set up in order to use a natural user interface (NUI) to manipulate the imaging software by hand gestures. The system allowed intraoperative touchless control of the surgical images. Results: For the first time in the literature, an NUI system was used for a pilot study during 11 dental surgery procedures including tooth extractions, dental implant placements, and guided bone regeneration. No complications were reported. The system performed very well and was very useful. Conclusion: The proposed system fulfilled the objective of providing touchless access and control of the system of images and a three-dimensional surgical plan, thus allowing the maintenance of sterile conditions. The interaction between surgical staff, under sterile conditions, and computer equipment has been a key issue. The solution with an NUI with touchless control of the images seems to be closer to an ideal. The cost of the sensor system is quite low; this could facilitate its incorporation into the practice of routine dental surgery. This technology has enormous potential in dental surgery and other healthcare specialties.

Oil-Air Lubrication Characteristics of a High Speed Spindle System for Machine Tools(I) Effect of Oil Supply Rate, Rotational Spindle Speed and Spindle System Structure (공작기계용 고속주축계의 오일에어윤활특성에 관한 연구 (I) 공급유량, 주축회전수 및 주축계 구조의 영향)

  • 김석일;최대봉;박경호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.351-358
    • /
    • 1993
  • Recently a high speed spindle system for machine tools has attracted considerable attention to reduce the machining time, to improve the machining accuracy, to perform the machining of light metals and hard materials and to unite the cutting and grinding processes. In this study, a high speed spindle system is developed by applying the oil-air lubrication method, angular contact ball bearings, injection nozzles with dual orifices and so on. And a lubrication experiment for evaluating the performance of the spindle system is carried out. Especially, in order to establish the lubrication conditions related to the development of a high speed spindle system, the effects of oil supply rate, rotational spindle speed and so on are studied and discussed on the bearing temperature rise, bearing temperature distribution and frictional torque. And the effect of spindle system structure on the bearing temperature distribution is investigated.

A Study on Performance Characteristics of Propane/Isobutane Refrigerant Mixtures in a Domestic Small Multi-Refrigeration System (프로판/이소부탄(R-290/R-600a) 혼합 냉매를 적용한 가정용 소형 멀티 냉동시스템의 성능특성에 관한 연구)

  • Kim Sanguk;Lee MooYeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.271-278
    • /
    • 2005
  • In this paper, the performance of Kim-chi refrigerator with three evaporator and one compressor was investigated in employing $55\%$ propane and $45\%$ isobutane (R290/R600a) refrigerant mixture as an alternative refrigerant of R134a. The drop-in test was performed by varying both refrigerant charge and capillary tube length in order to find both the performance and reliability of a small multi-refrigeration system. Results show that the power consumption is decreased by about $15\%$ and COP is increased by about $10\%$, respectively as compared to the baseline system using R-134a. In addition, the propane/isobutane refrigerant mixture system took advantage of the minimization of modification and redesigning of system components because thermodynamic properties such as saturation pressure, temperature, normal boiling point(NBP) characteristics are similar to those of R134a. The reduction of sales cost is caused by the decrease of refrigerant cost per unit mass and refrigerant charge amount necessary for the refrigeration system.

Study on Applicability of Household Fuel Cell System with Operating Methods (운전방법에 따른 가정용 연료전지 시스템의 적용성 검토)

  • Park, Deaheum;Cha, Kkwangseok;Jung, Younguan
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.2
    • /
    • pp.139-144
    • /
    • 2014
  • A Fuel Cell is one of the solving to reduce greenhouse gases. Despite the high efficiency and environmental friendly of Household Fuel Cell System it has hardly obtained popularity mainly due to its high prices. In order to encourage use of the system prices and operational expenses need to become economical. In this study, optimization through simulation was conducted to find out the optimal operational condition. As a result of simulation the system is operated with DSS operation from 5 O'clock until 19 O'clock for 13 hours at the constant output of 0.4kW to maximize reduction of energy rate. Furthermore, instead of the domestic system with the rated output of 1kW, rated output of the system should be reduced to 0.4 - 0.6kW which can promote installation of household Fuel Cell System.

The Modernization of Automatic Control facilities of Hydro Power Plant (수력발전소 자동제어설비의 현대화)

  • Kwon, O-Geuk;Kwon, Young-June;Song, Young-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.69-70
    • /
    • 2008
  • Automatic control systems(AVR, Governor, Synchronizer) installed $1970{\sim}1980$ in K-water were considered to be rehabilitated around 2000. Moreover, Korea Power Exchange market system was changed from PPA (Power Purchase Agreement) to a bidding system. Therefore, depending on the power quality, the power provider could achieve additional profits. It is the excitation system and governor that have the functions of enhancing power necessities. During the 20 to 30 years of generator operation, there were many major and minor problems. Examples are SCR burnout (Andong: Excitation system), hunting (Imha: governor), field circuit breaker failure (Chungju 1st: excitation system), the rise of leakage current (Chungju 2nd: excitation system), power supply burnout (Chungju 2nd: governor). These are the typical examples of malfunction which hindered the generator operation and, consequently, diminished the profit of power business. In order to satisfy the needs of the power market and prevent malfunctions mentioned above, the rehabilitation of AVRs and governors were executed. A new system was made to have the flexibility of ancillary service (GF, AGC, etc.), PSS function. With user friendly HMI software, it is more convenient for the operator to fulfill suitable maintenance. It was possible to connect SCADA system by opening protocol of AVR, governor for the efficiency of operation and maintenance.

  • PDF

The case report on pain treatment by extravascular laser system (비침습 레이저 조사기를 이용한 통증 치료에 대한 증례 보고)

  • Hwang, Young-Jun;Kim, Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.51-60
    • /
    • 2006
  • Objectives : The purpose of this study was to assess the ability of Extravascular Laser System on pain treatment. Methods : On this study, we carried out with the 9 cases of children who visited in the Department of Pediatrics, OO University Oriental Hospital as pain. 9 children suffering from pain were treated with Extravascular Laser System, and two of these were treated with combined acupuncture. In order to determine the degree of pain relief, a visual analogue scale was used. Results : Extravascular Laser System for pain resulted in a significant decline in the visual analogue scale. For Extravascular Laser System combined with acupuncture, VAS score has fallen by 30% each time compared to 17.5% of Extravascular Laser System only. In 2 cases of chronic pain, VAS score decreased to 0. In 7 cases of acute pain, All of 7 children improved 50% on VAS score, On average VAS score have seen 79.2% reduction. The average treatment times of chronic pain were 5 times, while that of acute pain were 4.1 times. Conclusions : We report the good result of the efficacy of extravascular laser system on children's pain. but, this study's cases were small in number. so more study is need.

  • PDF

A Study on Establishment of Regional Information System for Regional Equal Development (지역균형발전을 위한 지역정보체계의 구축에 관한 연구)

  • 황명린;최상철;조주현
    • Journal of the Korean Regional Science Association
    • /
    • v.8 no.1
    • /
    • pp.99-118
    • /
    • 1992
  • In spite of the rapid development of information and computer technology, the software side of those technologies has not been well studied especially in the area of regional planning. Throughout this study we identified some critical facts as below: 1) the necessity of region-specific information which is vital for urban and regional development, 2) the necessity of integration of information system into a regional unit rather than setoral unit, 3) aggravated regional inequality through the spread of communication and computing tools, and 4) advanced regional information system linking satellite and graphic computers in developed countries. From these facts, we recommend some policy directions as below: 1) It is desperately needed to establish a regional information center covering large administrative area. 2) In establishing these system, we can utilize existing communication network or estblish a brand new system. Utilization of existing administrative network and board of statistics for data collection and management, and the utilization of postal office or telephone company for distribution are recommended through the evaluation of those two alternatives, 3) It is also recommended that one-step data collection system should be established. 4) The Dat Base should be organized in many steps in close relationship with development goal and planning process. In order to make most use of this system, we need to develop a monitoring system, regional indicators and ex-ante impact studies.

  • PDF

Study on the Development of Meridian Impedance Measurement System (경락 임피던스 측정 시스템 개발에 관한 연구)

  • Lee, Woo-Cheol;Yin, Chang-Shik;Min, Kyoung-Kee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

Direct assignment of the dynamics of a laboratorial model using an active bracing system

  • Moutinho, C.;Cunha, A.;Caetano, E.
    • Smart Structures and Systems
    • /
    • v.8 no.2
    • /
    • pp.205-217
    • /
    • 2011
  • This article describes the research work involving the implementation of an Active Bracing System aimed at the modification of the initial dynamics of a laboratorial building structure to a new desired dynamics. By means of an adequate control force it is possible to assign an entirely new dynamics to a system by moving its natural frequencies and damping ratios to different values with the purpose of achieving a better overall structural response to external loads. In Civil Engineering applications, the most common procedures for controlling vibrations in structures include changing natural frequencies in order to avoid resonance phenomena and increasing the damping ratios of the critical vibration modes. In this study, the actual implementation of an active system is demonstrated, which is able to perform such modifications in a wide frequency range; to this end, a plane frame physical model with 4 degrees-of-freedom is used. The Active Bracing System developed is actuated by a linear motor controlled by an algorithm based on pole assignment strategy. The efficiency of this control system is verified experimentally by analyzing the control effect obtained with the modification of the initial dynamic parameters of the plane frame and observing the subsequent structural response.

A Study on the Development of Integrated Logistics System for Hospital Logistics Cooperation (병원물류 공동화를 위한 통합물류 시스템 구축에 관한 연구)

  • Park, Jong Suk;Kim, Han Sung;Lee, Jae Gun;Choi, Hoon Young;Kang, Kyung Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.139-146
    • /
    • 2014
  • In Korea's distribution and production field establishment of logistics information system and automation of logistics were greatly developed. But there is no characteristic and professionalism about hospital logistics, and distribution center is located in outside warehouse, logistics system is very important. Since hospital has human power to receive product, system is not as much required, but outside warehouse requires system for arrival from medicine and medical supplies wholesale dealer and vender, warehousing, storage, and automation facilities, and system for various works such as peaking instruction, classification, packing, cargo-working, delivery, order of medicine from hospital and non-medicine in hospital is essential. Therefore, This study is about development of automatic identification of slide which cannot be overlooked in efficiency of hospital logistics, establishment of database, and information interlocking between automatic storage system and outside warehouse.