• Title/Summary/Keyword: 2 order system

Search Result 14,807, Processing Time 0.044 seconds

A Study on the Improvement of Weapon System T&E performance System (국방 무기체계 시험평가 수행체계 개선방안 연구)

  • BaekJung Kim;Sukjae Jeong
    • Journal of The Korean Institute of Defense Technology
    • /
    • v.5 no.2
    • /
    • pp.1-9
    • /
    • 2023
  • The purpose of this study is to derive the need to improve the test and evaluation(T&E) performance system of the weapon systems to which advanced science and technology is applied, evaluate priorities, and present development plans. T&E of Al-based weapon systems through a literature research and case analysis on changes in the T&E environment for weapon system, 11 detailed evaluation items were derived from the in terms of the T&E system, structure, and technology. Al-based weapon system test evaluation should be performed in parallel with data-based performance evaluation and actual T&E, and performance measurement using a separate T&E data set is required for AI models performance evaluation. As a result of analyzing the importance of T&E through AHP analysis, the order of T&E system-technology-structure was evaluated, and the priority of detailed evaluation items was evaluated in the order of T&E result judgment-T&E organization and expert training-scientific T&E. For evaluation items with high priority, measures to improve the T&E performance system were presented.

  • PDF

cis-trans Isomeric and Substituent Effects on the Lanthanide Induced Shifts in 2-Phenylcyclopropanic System

  • So, Jung-Ho;Cho, Nam-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.6
    • /
    • pp.226-230
    • /
    • 1984
  • LIS's of cis and trans-methyl-2-phenylcyclopropanecarboxylate, cis and trans-t-butyl-2-phenylcyclopropanecarboxylate, cis and trans-N,N-dimethylcyclopropanecarboxamide, trans-2-phenylcyclopropyl methyl ketone and trans-2-phenylcyclopropyl t-butyl ketone have been studied. The LIS's hold the McConnell-Robertson relation and are mainly influenced by the steric effect. LIS's of trans isomers are larger than those of cis isomers. In trans isomers, the LIS's decrease in the following order: methyl ketone > methyl ester > N,N-dimethyl amide > t-butyl ketone${\sim}$t-butyl ester.

Analytical Study on the Optimal Operating Control of A Hybrid Geothermal Plant (지열복합 열원가기 최적운전채어에 관한 해석적 연구)

  • Jeon, Jong-Ug;Park, Jong-Sam;Myung, Woo-Ho;Kim, Young-Ki;Kim, Yong-Chan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • The objective of this study is to find the optimal control algorithm of a hybrid Plant, which is combined by renewable energy plant of the GSHP(Geothermal Source Heat Pump) and the normal plant (Chiller, boiler). The work presented in this study was carried out in the EnergyPlus(Version 2.0). The EnergyPlus was modified in order to simulate the hybrid plant. The plant system was controlled by the load-range-based operation in which schemes select a user specified set of equipment for each user specified range of a particular simulation condition. In the use of the load-range-based operation, four kind of control cases were defined and simulated in order to obtain the optimal control algorithm of the hybrid plant. The result showed that the Case 2 was the optimal control algorithm which used the GSHP as a base operating plant and the normal plant as an assistant operating plant. Even though the normal plant was operated in full load and the renewable energy plant of the GSHP was operated in partial load, the annual energy consumption of the normal plant was larger than that of the GSHP plant.

7×7 MIMO System Using Extended 13-Element ESPAR Antenna (확장 13-Element EPSAR 안테나를 사용한 7×7 MIMO 시스템)

  • Bok, Junyeong;Lee, Seung Hwan;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.2
    • /
    • pp.69-76
    • /
    • 2014
  • Multiple-input and multiple-output (MIMO) technique is used in many communication fields in order to increase the channel capacity. However, this MIMO system has difficulty of miniaturization of antenna size due to the multiple RF chains Also, multiple RF chain raises some problems which increase power consumption at RF circuit and degrade the system performance due to the interference between RF chains. Because of these reasons, beamspace MIMO (BS-MIMO) technique with only single RF chain was proposed for MIMO transmission. This BS-MIMO system basically uses electronically steerable parasitic array radiator (ESPAR) antenna. Existing ESPAR antenna has a 5-element structure. So, it is possible to do only $3{\times}3$ MIMO transmission. Therefore, in order to extend BS-MIMO dimension, extension of ESPAR antenna structure is essential. In this paper, we show that BS-MIMO dimension can be increased according to the extension of structure of the ESPAR antenna, as in the conventional MIMO techniques. For example, we show that it is possible to design the $7{\times}7$ BS-MIMO transmissions with the 13-element ESPAR antenna. Also, when the number of parasitic elements of ESPAR antenna increases by two elements, MIMO dimension is expanded by 1.

Development of Digital Controller and Monitoring System for UPS Inverter (UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발)

  • Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • In this paper, a new fully digital control method for UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The inner current control loop is adopted by an internal model controller. The internal model controller is designed to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. The outer voltage control loop employing P-Resonance controller is proposed. The resonance controller has an infinite gain at resonant frequency, and the resonant frequency is set to the fundamental frequency of the reference voltage in this paper. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been verified by the simulation and experimental results respectively.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

The effective implementation of adaptive second-order Volterra filter (적응 2차 볼테라 필터의 효율적인 구현)

  • Chung, Ik Joo
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.570-578
    • /
    • 2020
  • In this paper, we propose an efficient method for implementing the adaptive second-order Volterra filter. To reduce computational load, the UCFD-SVF has been proposed. The UCFD-SVF, however, shows deteriorated convergence performance. We propose a new method that initializes the adaptive filter weights periodically on the fact that the energy of the filter weights is slowly increased. Furthermore, we propose another method that the interval for the weight initialization is variable to guarantee the performance and we shows the method gives the better performance under the non-stationary environment through the computer simulation for the adaptive system identification.

Research on the development of demand for medical and bio technology using big data (빅데이터 활용 의학·바이오 부문 사업화 가능 기술 연구)

  • Lee, Bongmun.;Nam, Gayoung;Kang, Byeong Chul;Kim, CheeYong
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.345-352
    • /
    • 2022
  • Conducting AI-based fusion business due to the increment of ICT fusion medical device has been expanded. In addition, AI-based medical devices help change existing medical system on treatment into the paradigm of customized treatment such as preliminary diagnosis and prevention. It will be generally promoted to the change of medical device industry. Although the current demand forecasting of medical biotechnology commercialization is based on the method of Delphi and AHP, there is a problem that it is difficult to have a generalization due to fluctuation results according to a pool of participants. Therefore, the purpose of the paper is to predict demand forecasting for identifying promising technology based on building up big data in medical biotechnology. The development method is to employ candidate technologies of keywords extracted from SCOPUS and to use word2vec for drawing analysis indicator, technological distance similarity, and recommended technological similarity of top-level items in order to achieve a reasonable result. In addition, the method builds up academic big data for 5 years (2016-2020) in order to commercialize technology excavation on demand perspective. Lastly, the paper employs global data studies in order to develop domestic and international demand for technology excavation in the medical biotechnology field.

Independent MPP Tracking Method of Hybrid Solar-Wind Power Conditioning Systems Using Integrated Dual-Input Single-PWM-Cell Converter Topology

  • Thenathayalan, Daniel;Ahmed, Ashraf;Choi, Byung-Min;Park, Jeong-Hyun;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.790-802
    • /
    • 2017
  • This paper proposes the modeling and control strategy to track the MPPs of hybrid PV and Wind power systems, using a new dual input boost converter. The dual input power conditioning system with an independent MPPT control scheme is introduced with minimum number of circuit elements in order to reduce the switching loss, size and cost of the system. Since the operating conditions for the PV and Wind power systems are very distinct from each other, an efficient and superior control system is required to track the MPPs of both renewable sources with the use of a simply-structured single-ended single-inductor converter. The design of Power-Conditioning System (PCS) and detail control strategy are presented in this paper. To provide independent tracking of MPPs, a variable duty-cycle control strategy is employed for the wind system and a variable frequency strategy is employed for the PV system. Finally, the proposed dual-input converter for hybrid power conditioning system is implemented and the hardware test results are presented. From the hardware experiment, it is concluded that the proposed system successfully tracks the MPPs of both of the renewable power systems independently.

A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer (Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究))

  • Suh, W.M.;Min, Y.B.;Yoon, Y.C.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF