• Title/Summary/Keyword: 2 전극

Search Result 3,932, Processing Time 0.033 seconds

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

A STUDY ON THE CHANGE OF SALIVARY FLUORIDE CONCENTRATION WITH TIME AFTER VARIOUS TOPICAL FLUORIDE TREATMENTS (각종 불소처치 이후 시간변화에 따른 타액내 불소농도 변화에 관한 연구)

  • Park, Soo-Jin;Kim, Hyung-Doo;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.262-274
    • /
    • 1999
  • Several alternatives for increasing the fluoride concentration in the mouth, such as water fluoridation, ingestion of fluoride supplements, fluoride paste, fluoride mouthrinse, application of fluoride gel are available. There is an impressive body of evidence that the topically deliverd fluorides are clinically effective in inhibiting the progression of dental caries. Recent studies on the cariostatic action of fluoride have indicated the importance of fluoride in the fluid environment of the teeth. The fluoride levels in unstimulated whole saliva can be considered indicative of F in the aqueous phase available for interaction with the tooth surface at a given time. The retention of F in the mouth after topical fluoride treatment is considered to be an important factor in the clinical efficacy of F. The aim of this study was to determine the elevation and clearance of fluoride in whole saliv after the following topical flouride treatments using HMDS-diffusion technique and fluoride ion electrode. The obtained results were as follow: 1. Average salivary fluoride concentration in the unstimulated whole saliva was $0.0152ppm{\pm}0.0091ppm$. Unstimulated salivary flow rate was between 0.34-0.36ml/min and there was no statistically significant difference among the groups(p>0.05). 2. Except for the immediate time after treatment, fluoride levels followed as APF gel>neutral gel>F-rinse>F-paste. There was no statistical difference between the salivary F concentration of F-paste group and that of control group after 2 hours. In case of F-rinse group, after 3 hours the concentration had dropped to baseline value. But there was statistically significant difference among the F concentraion of F gel groups and that of control group(p<0.05). 3. The mean $AUC_{0-120min}$ values were followed as neutral gel>APF gel>F-rinse>F-paste, and the values of the two former groups were significantly higher than those of the two latter groups(p<0.05).

  • PDF

Melting Characteristics for Radioactive Aluminum Wastes in Electric Arc Furnace (아크 용융로에서 방사성 알루미늄 폐기물의 용융특성)

  • Min, Byung-Youn;Song, Pyung-Seob;Ahn, Jun-Hyung;Choi, Wang-Kyu;Jung, Chong-Hun;Oh, Won-Zin;Kang, Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.33-40
    • /
    • 2006
  • The characteristics of the aluminum waste melting and the distribution of the radioactive nuclides have been investigated for the estimation on the volume reduction and the decontamination of the aluminum wastes from the decommissioning of the TRIGA MARK it and III research reactors at the Korea Atomic Energy Research Institute(KAERI). The aluminum wastes were melted with the use of the fluxes such as flux $A:NaCl-KCl-Na_3AlF_6$, flux B:NaCl-NaF-KF, flux $C:CaF_2$, and flux $D:LiF-KCl-BaCl_2$ in the DC graphite arc furnace. For the assessment of the distribution of the radioactive nuclides during the melting of the aluminum, the aluminum materials were contaminated by the surrogate nuclides such as cobalt(Co), cesium(Cs) and strontium(Sr). The fluidity of aluminum melt was increased with the addition of the fluxes, which has slight difference according to the type of fluxes. The formation of the slag during the aluminum melting added the flux type C and D was larger than that with the flux A and B. The rate of the slag formation linearly increased with increasing the flux concentration. The results of the XRD analysis showed that the surrogate nuclide was transferred to the slag, which can be easily separated from the melt and then they combined with aluminum oxide to form a more stable compound. The distribution ratio of cobalt in ingot to that in slag was more than 40% at all types of fluxes. Since vapor pressures of cesium and strontium were higher than those that of the host metals at the melting temperature, their removal efficiency from the ingot phase to the slag and the dust phase was by up to 98%.

  • PDF

Surgical Treatment of Ventricular Tachycardia After Total Correction of Tetralogy of Fallot- Report of a case (TOF 완전교정술후 발생한 심실빈맥의 외과적 절제술 -치험1례보고-)

  • 장병철;김정택
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.639-645
    • /
    • 1996
  • A 14-year-old male patient with previous surgical repair of tetralogy of Fallot was admitted with hemodynamically significant ventricular tachycardia (VT). On preoperative electrophysiologic study (EPS), the morphology of documented VT was RBBB of vertical axis with 320 msec cycle length. The endocardial mapping during VT delineated the origin of VT at right ventricular outflow tract (RVOT), where the patch was attached. The clinical VT had a clockwise reentry circuit around the patch with the earliest activation at the same site seen during the preoperative EPS. The previously placed right ventricular outflow patch and fibrous tissue were removed. During a postoperative EPS, it was no longer possible to induce the VT. Ventricular tachycardia following repair of tetralogy of Fallot seen in this patient was caused by a macro-reentry around the right ventricular outflow patch. We were able to ablate the VT with the aid of a detailed mapping of its epicardial activation sequence.

  • PDF

Response of Electrocardiogram to Mirror carp, Cyprinus carpio of Body Length (체장에 따른 향어, Cyprinus carpio의 심전도)

  • 김영기;양용림;안영일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.284-288
    • /
    • 2002
  • The authors examined the response of electrocardiogram (ECG) to Mirror carp, Cyprinus carpio of body length. The experiments were performed of three classes (10~15, 15~20 and 20~25cm) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 30 minutes in 16-18$^{\circ}C$. The results which are divided into by day and by night and then analyzed by fishes' conditions are as follows; 1 In case of body length 10~15 cm, the average heart rate 43.4 beat/min by day and 45.9 beat/min by night, the average action potential 4.38 $mutextrm{V}$ by day and 3.64 $mutextrm{V}$ by night, in narcotism condition(0~9 min). the average heart rate 69.4 beat/min by day and 67.4 beat/min by night, the average action potential 3.82 $mutextrm{V}$ by day and 3.50 $mutextrm{V}$ by night, in stable condition(9~30 min). 2. In case of body length 15~20 cm, the average heart rate 42.2 beat/min by day and 45.4 beat/min by night, the average action potential 4.13 $mutextrm{V}$ by day and 3.95 $mutextrm{V}$ by night, in narcotism condition(0-5 min). the average heart rate 67.6 beat/min by day and 65.3 beat/min by night, the average action potential 4.58$mutextrm{V}$ by day and 4.61 $mutextrm{V}$ by night, in stable condition (5~30 min). 3. In case of body length 20~25 cm, the average heart rate 47.5 beat/min by day and 47.5 beat/min by night, the average action potential 4.81 $mutextrm{V}$ by day and 4.20 $mutextrm{V}$ by night, in narcotism condition(0-4 min). the average heart rate 67.5 bea/min by day and 64.8 beat/min by night, the average action potential 5.31 $mutextrm{V}$ by day and 4.90 $mutextrm{V}$ by night, in stable condition (4~30 min).

Effect of Prenatal Fluoride on Bone Compositions of Rat (태생 전 불소투여로 인한 태생직후 백서 골조성 변화)

  • Kim, Hye-Young;Kwun, Hyun-Sook;Song, Keun-Bae;Hong, Suk-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.2 no.2
    • /
    • pp.175-186
    • /
    • 2002
  • Fluoride has been one of the most widely studied caries-preventive agents. But the effect of prenatal administration had been controversies for many years. The results showed that there were no influence on reproductive rate of rats with administration of fluoride from 0 to 20 ppm during pregnancy(p>0.05). There was a trend towards slightly increased the mean ash weight in the 1, 5 and 20 ppm groups, as compared with the control group. However, there was no significant differences among groups (p>0.05). The contents of calcium, magnesium and phosphorus in the total bone were increased with the administrated fluoride concentration were increased, but there were no statistically significant differences among groups(p>0.05). The mean fluoride level of 1 ppm group was significantly higher than that of control group, but the concentrations of fluoride in total carcass pups of 5 and 20 ppm groups were significantly less than that of 1 ppm group(p>0.05). The results of this study indicate that the amount of fluoride transferred to the offspring, which may produce anticariogenic effects in the primary teeth of their effects in the primary teeth of their offspring.

  • PDF

Monthly HPLC Measurements of Pigments from an Intertidal Sediment of Geunso Bay Highlighting Variations of Biomass, Community Composition and Photo-physiology of Microphytobenthos (HPLC를 이용한 근소만 조간대 퇴적물내의 저서미세조류 현존량, 군집 및 광생리의 월 변화 분석)

  • KIM, EUN YOUNG;AN, SUNG MIN;CHOI, DONG HAN;LEE, HOWON;NOH, JAE HOON
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.1
    • /
    • pp.1-17
    • /
    • 2019
  • In this study, the surveys were carried out from October (2016) to October (2017) along the tidal flat of Geunso Bay, Taean Peninsula of the western edge of Korea. The sampling trips were carried out for a total of 16 times, once or twice a month. In order to investigate the monthly variation of the microphytobenthos (MPB) biomass, community composition and photo-physiology were analyzed by HPLC (High performance liquid chromatography). The total chlorophyll a (TChl a) concentrations used as an indicator of biomass of MPB in the upper 1 cm sediment layer ranged from 40.4 to $218.9mg\;m^{-2}$ throughout the sampling period. TChl a concentrations showed the maximum level on $24^{th}$ of February and remained high throughout March after which it started to declined. The biomass of MPB showed high values in winter and low values in summer. The monthly variations of Phaeophorbide a concentrations suggested that the low grazing intensity of the predator in the winter may have partly attributed to the MPB winter blooming. As a result of monthly variations of the MPB community composition using the major marker pigments, the concentrations of fucoxanthin, the marker pigment of benthic diatoms, were the highest throughout the year. The concentrations of most of the marker pigments except for chlorophyll b (chlorophytes) and peridinin (dinoflagellates) increased in winter. However, the concentrations of fucoxanthin increased the highest, and the relative ratios of the major marker pigments to TChl a except fucoxanthin decreased during the same period. The vertical distribution of Chl a and oxygen concentrations in the sediments using a fluorometer and an oxygen micro-optode Chl a concentrations decreased with oxygen concentrations with increasing depth of the sediment layers. Moreover, this tendency became more apparent in winter. The Chl a was uniformly vertical down to 12 mm from May to July, but the oxygen concentration distribution in May decreased sharply below 1 mm. The increase in phaeophorbide a concentration observed at this time is likely to be caused by increased oxygen consumption of zoobenthic grazing activities. This could be presumed that MPB cells are transported downward by bioturbation of zoobenthos. The relative ratios (DT/(DD+DT)) obtained with diadinoxanthin (DD) and diatoxanthin (DT), which are often used as indicators of photo-adaptation of MPB, decreased from October to March and increased in May. This indicated that there were monthly differences in activity of Xanthophyll cycle as well.

Implementation of Capacitor and Inductor Applied LCP Substrate for 35-GHz frequency band (35 GHz 대역을 위한 LCP 기판 적용된 커패시터 및 인덕터 구현)

  • Lee, Jiyeon;Ryu, Jongin;Choi, Sehwan;Lee, Jaeyoung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.67-75
    • /
    • 2020
  • In this paper, by applying LCP substrate, the capacitor and inductor are implemented with a variety of value that can be used in 35 GHz circuits. Depending on how to apply it to the circuit, it is required high value by designing the basic structures such as electrode capacitor and spiral inductor. However they are not available in high-frequency domain, because their SRF(Self-Resonant Frequency) is lower than the frequency of 35-GHz. By finding the limit, this paper devised classifying passive devices for the DC and the high-frequency domain. The basic structure is suitable for DC and microstrip λ/8 length stub structure can be used for high-frequency. The open and short stub structure operate as a capacitor and inductor respectively in the frequency of 35 GHz. If their impedance is known, it is possible to extract the value through the impedance-related equation. By producing with the permittivity 2.9 LCP substrate, the basic structure which are available in the DC constituted a library of capacitance of 1.12 to 13.9 pF and inductance of 0.96 to 4.69 nH, measured respectively. The stub structure available in the high-frequency domain were built libraries of capacitance of 0.07 to 2.88 pF and inductance of 0.34 to 1.27 nH, calculated respectively. The measurements have proven how to diversify value, so libraries can be built more variously. It is possible to integrate with the operation circuit of TRM(Transmit-Receive Module) for the frequency 35-GHz, it will be an alternative to the passive devices that can be properly utilized in the circuit.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.

FES Exercise Program for Independent Paraplegic Walking (하반신 마비환자의 FES 독립보행을 위한 근육 강화 프로그램)

  • Khang, Seon-Hwa;Khang, Gon;Choi, Hyun-Joo;Kim, Jong-Moon;Chong, Soon-Yeol;Chung, Jin-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.69-80
    • /
    • 1998
  • This research was designed to investigate how the exercise program affects paraplegic standing and walking employing functional electrical stimulation(FES). Emphasis was also given to fatigue of major lower extremity muscles induced by different types of electrical stimulation. We applied continuous and intermittent rectangular pulse trains to quadriceps of 10 normal subjects and 4 complete paraplegic patients. The frequencies were 20Hz and 80Hz, and the knee angle was fixed at 90$^{\circ}$and 150$^{\circ}$to investigate how muscle fatigue is related to muscle length. The knee extensor torque was measured and monitored. We have been training quadriceps and gastrocnemius of a male paraplegic patient by means of electrical stimulation for the past two year. FES standing was initiated when the knee extensors became strong enough to support the body weight, and then the patient started FES walking utilizing parallel bars and a walker. We used an 8-channel constant-voltage stimulator and surface electrodes. The experimental results indicated that paralyzed muscles fatigued rapidly around the optimal length contrary to normal muscles and confirmed that low frequency and intermittent stimulation delayed fatigue. Our exercise program increased muscle force by approximately 10 folds and decreased the fatigue index to half of the initial value. In addition, the exercise enabled the patient to voluntarily lift each leg up to 10cm, which was of great help to the swing phase of FES walking. Both muscle force and resistance to fatigue were significantly enhanced right after the exercise was applied every day instead of 6 days a week. Up to date, the patient can walk for more than two and half minutes at 10m/min while controlling the on/off time of the stimulator by pushing the toggle switch attached to the walker handle.

  • PDF