• 제목/요약/키워드: 2차원 Monte Carlo 모의

Search Result 18, Processing Time 0.032 seconds

The Calculation of Response Matrix of 2-Dimensional Radiation Monitoring System Using EGS4 Simulation (EGS4 simulation을 이용한 2차원 방사선준위 분포측정 시스템의 Response Matrix 계산)

  • Kim, S.H.;Han, S.H.;Kang, H.D.;Kim, J.C.;Park, I.K.;Choi, Y.S.;Lee, Y.B.;Lee, J.M.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.127-133
    • /
    • 1997
  • In this study an EGS4 simulation code was used to calculate real energy spectrum from measured ${\gamma}$-ray energy spectrum obtained using 2-dimensional radiation monitoring system. As a result, the $39{\times}39$ response matrix was calculated the energy range of 0.1 to 2 MeV which energy interval of 50 keV The real energy spectrum for Co-60 radioisotope was calculated using inverse of response matrix. It was confirmed that the calculated response matrix was useful to the analysis of the measured energy spectrum for the radiation monitoring system.

  • PDF

Flood Estimation Considering Uncertainty (불확실성을 고려한 홍수량 추정)

  • Seo, Young-Min;Kim, Sung-Bum;Jang, Kwang-Jin;Jee, Hong-Kee;Lee, Soon-Tak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1900-1904
    • /
    • 2007
  • 지금까지 수공구조물의 설계와 기존 시설의 안전도를 평가시 수문, 수리 및 경제학적 함수들에서 발생하는 불확실성을 설명하기 위하여 안전율 또는 여유고를 증가시키거나 이들 정보의 양과 질을 증가시켜 데이터베이스를 확장하고 측정오차를 최소화시키며, 전통적인 통계해석을 적용하였다. 공공의 안전을 확보하기 위하여 설계과정에 안전율 또는 여유고가 도입되었으나 이것은 단순히 보다 높은 재현기간의 적용을 의미하며, 수문현상이 가지는 추계학적 특성보다 확정론적인 근거로부터 안전설계 개념이 개발되었다. 수자원 계획시 고려되는 부하와 저항은 확정론적인 고정치가 아니라 시간에 따라 변하고 동적이며, 무작위적이므로 확률 변수로서 고려되어야 한다. 이에 따라 최근 수자원 계획과정에서 불확실성 해석에 의한 위험도 분석 개념이 도입되고 있으며, 특히 이상기후 및 집중호우의 빈발, 급격한 도시화로 인한 유출양상의 변화 등으로 급증하고 있는 훙수피해를 감안할 때 설계빈도의 상향조정과 같은 확정론적인 방법보다는 매개변수 또는 함수의 불확실성을 고려한 위험도 해석의 필요성이 더욱 증대되고 있는 실정이다. 따라서 본 논문에서는 수자원 계획시 입력자료 및 매개변수의 불확실성과 불확실성의 분리를 고려한 홍수량의 산정 및 각 매개변수의 영향을 평가하여 홍수위험도 해석에 있어서 모델 매개변수의 영향 규명과 처리방안을 제시하고자 한다.

  • PDF

Chi-Squared Test of Independence in Case that Two Marginal Distributions are Given Exactly (모집단 부분정보가 주어진 상황에서의 분할표 독립성 검정)

  • 이광진
    • The Korean Journal of Applied Statistics
    • /
    • v.17 no.1
    • /
    • pp.89-103
    • /
    • 2004
  • If the given information is exact, though it is the little, we had better use it than not use in analysis. In this article, the problem of independence test in a contingency table is considered when two marginal distributions of a population are given exactly. For that case, a likelihood-ratio chi-squared test statistic and its Pearsonian type chi-squared test statistic are derived. By Monte Carlo Simulations the traditional chi-square tests and the derived tests are compared. And the related some testing problems are synthetically explained on a geometrical viewpoint.

Analysis of Photon Characteristics and Absorbed Dose with Cone Beam Computed Tomography (CBCT) using Monte Carlo Method (몬테칼로 기법을 이용한 CBCT의 광자선 특성 및 선량 분석)

  • Kim, Jong-Bo;Kim, Jung-Hoon;Park, Eun-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • The cone beam computed tomography(CBCT) which can acquire 3-dimensions images is widely used for confirmation of patient position before radiation therapy. In this study, through the simulation using the Monte Carlo technique, we will analyze the exposure dose by cone beam computed tomography and present the standardized data. For the experiment, MCNPX(ver. 2.5.0) was used and the photon beam spectrum was analyzed after Cone beam was simulated. As a result of analyzing the photon beam spectrum, the average energy ranged from 25.7 to 37.6 keV at the tube voltage of 80 ~ 120 kVp and the characteristic X-ray energy was 9, 60, 68 and 70 keV. As a result of using the water phantom, the percentage depth dose was measured, and the maximum dose appeared on the surface and decreased with depth. The absorbed dose also decreased as the depth increased. The absorbed dose of the whole phantom was 9.7 ~ 18.7 mGy. This is a dose which accounts for 0.2% of about 10 Gy, which is generally used for radiation therapy per week, which is not expected to have a significant effect on the treatment effect. However, it should not be overlooked even if it is small compared with prescription dose.

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF

Application of the Poisson Cluster Rainfall Generation Model to the Urban Flood Analysis (포아송 클러스터 강우 생성 모형을 이용한 도시 홍수 해석)

  • Park, Hyunjin;Yang, Jungsuk;Han, Jaemoon;Kim, Dongkyun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.729-741
    • /
    • 2015
  • This study examined the applicability of MBLRP (Modified Bartlett-Lewis Rectangular Pulse) rainfall generation model for an urban flood simulation which is a type of Poisson cluster rainfall generation model. This study constructed XP-SWMM model for Namgajwa area of Hongjecheon basin, which is a two-dimensional pipe network-surface flood simulation program and computed a flood discharge and a flooded area with input data of synthetic rainfall time series of 200 years that were generated by the MBLRP model. This study compared the data of flood with synthetic rainfall and flood with corresponding values which were based on design rainfall. The results showed that the flooded area computed with MBLRP model was somewhat smaller than the corresponding values on the basis of the design. A degree of underestimation was from 8% (5 year) to 34% (200 year) and the degree of underestimation increased as a return period increased. This study is meaningful in that it proposes methodology that enables quantifiability of uncertain variables which are related to a flooding through Monte Carlo analysis of urban flooding simulation and applicability and limitations thereof.

Identification of soil Remedial Goal due to Arsenic in Soil near Abandoned Mine- Approach to Regarding Future Land Use - (폐광산 지역의 비소오염에 대한 복원목표 설정 - 미래 토지용도를 고려한 접근방법 -)

  • 이효민;윤은경;최시내;박송자;황경엽;조성용;김선태
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.2
    • /
    • pp.13-29
    • /
    • 1998
  • Recently, It is increasing popularity to research on the soil remediation in aspect of management by reason of the hazardous impact on the contaminated soil in Korea. It was investigated high levels of arsenic salts in soil near abandoned five mines(Darak, Daduk, Jingok, Dalsung, Ilkwang) located in Youngnam area. Arsenic, classified as group A(Human Carcinogens) from IRIS, have shown statistically significant increment in skin cancer with oral exposure. This paper was conducted to predict excess cancer risk value (to the skin cancer) based on multiple pathway such as soil ingestion, dermal uptake and food(plant) ingestion contaminated by arsenic, and also, to identify the remedial goal regarded in future land use. The mine having the highest arsenic level was Daduk(mean : 1950mg/kg) and the next rank was Jingok(1690mg/kg), Ilkwang(352.37mg/kg), Dalsung(86.08mg/kg), Darak(0.83mg/kg). The chronic daily intake to the multiple exposure were calculated using Monte-Carlo simulation regarded in future land use and used q: value was $1.5(mg/kg/day)^{-1}$ to the oral proposed by IRIS(1997). The computated excess cancer risk 95th value to all the mine regarding future land use as residential and rural area were more than $10^{-4}$. If the level of acceptable risk is aimed for 1$\times$$10^{-6}$, it could be used Darak as commercial and industrial area without soil remediation due to the lowest risk value(6$\times$$10^{-8}$ and 3$\times$$10^{-8}$). Computated remedial goal based on 1$\times$$10^{-6}$ of acceptable risk to the future land use as the residential, rural, commercial and industrial area were 0.02mg/kg, 0.003mg/kg, 97.31mg/kg and 194.62mg/kg, respectively.

  • PDF

Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer (전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향)

  • Kwak, Jung-Won;Shin, Jung-Wook;Kim, Jin-Sung;Park, Sung-Yong;Shin, Dong-Ho;Yoon, Myong-Geun;Park, So-Ah;Kim, Dong-Wook;Lim, Young-Gyeung;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.291-297
    • /
    • 2010
  • This study examined the dosimetric influence of implanted gold markers in proton therapy and the effects of their positions in the spread-out Bragg peak (SOBP) proton beam. The implanted cylindrical gold markers were 3 mm long and 1.2 mm in diameter. The dosimetric influence of the gold markers was determined with markers at various locations in a proton-beam field. Spatial dose distributions were measured using a three-dimensional moving water phantom and a stereotactic diode detector with an effective diameter of 0.5 mm. Also, a film dosimetry was performed using Gafchromic External Beam Treatment (EBT) film. The GEANT4 simulation toolkit was used for Monte-Carlo simulations to confirm the measurements and to construct the dose-volume histogram with implanting markers. Motion data were obtained from the portal images of 10 patients to investigate the effect of organ motions on the dosimetric influence of markers in the presence of a rectal balloon. The underdosed volume due to a single gold marker, in which the dose was less than 95% of a prescribed amount, was 0.15 cc. The underdosed volume due to the presence of a gold marker is much smaller than the target volume. However, the underdosed volume is inside the gross tumor volume and is not smeared out due to translational prostate motions. The positions of gold markers and the conditions of the proton-beam field give different impacts on the dose distribution of a target with implanted gold markers, and should be considered in all clinical proton-based therapies.