• 제목/요약/키워드: 2차원 9방향

검색결과 198건 처리시간 0.031초

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • 제29권2호
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

Consideration of New Convergence Security Threats and Countermeasures in the Zero-Contact Era (비대면 시대의 신 융합보안 위협과 대응 방안에 대한 고찰)

  • Yu, Dong-Hyun;Kim, Yong-Uk;Ha, Young-Jae;Ryu, Yeon-Seung
    • Journal of the Korea Convergence Society
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2021
  • Recently, new types of security crimes have been steadily occurring in Korea due to environmental changes such as the development of IT technology, and responding to these threats has become a key national task for the establishment of a safe society as well as individuals and businesses. Meanwhile, as the Zero-Contact Era has arrived since the COVID-19 Pandemics, a new convergence security threat that combines the characteristics of the Zero-Contact Era with the existing IT development is threatening our society. Research to prevent and correct these new levels of threats is continuously required in this study. Chapter 1 examined the causes of new convergence security threats and Chapter 2 discussed cybersecurity, fake news, remote voting·work and video security threats as five major threats.

A Design of Improved 100 GHz Lens Antennas for the ECEI System (ECEI 장치를 위한 향상된 성능의 100 GHz 렌즈 안테나 설계)

  • Lee, Gwan-Hee;Kim, Sung-Kyun;Mohyuddin, Wahab;Choi, Hyun-Chul;Kim, Kang Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제27권9호
    • /
    • pp.817-824
    • /
    • 2016
  • In this paper, a modified elliptical lens antenna design is proposed to improve the performance of 100 GHz mini-lens antennas used in the ECEI(Electron Cyclotron Emission Imaging) module at KSTAR. A hemispherical lens is added on the bottom plate of the conventional elliptic lens antenna, and a 100 GHz dipole antenna is located on the end point of the hemispherical lens. Using geometrical optics, antenna radiated EM fields are designed to be totally reflected from the inner surface of the hemispherical lens, and thereby the antenna patterns are more focused toward the main beam. The validity of the proposed design is confirmed by the 3D EM simulator. The modified elliptical lens antenna provides 23.8 dB maximum gain, which is 2.2 dB gain improvement as compared with the conventional elliptic lens. Also, the side love levels of E- and H-planes are decreased by 2.6 dB and 3.4 dB, respectively.

Performance Analysis of Secondary Gas Injection for a Conical Rocket Nozzle TVC(II) (2차 가스분사에 의한 원추형 로켓노즐 추력벡터제어 성능해석 (II))

  • Song, Bong-Ha;Ko, Hyun;Yoon, Woong-Sup;Lee, Sang-Kil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제5권1호
    • /
    • pp.18-25
    • /
    • 2001
  • The results of systematic numerical experiments of secondary gas injection thrust vector control are presented. The effects of secondary injection system such as injection location and nozzle divergent cone angle onto the overall performance parameters such as thrust ratio, specific impulse ratio and axial thrust augmentation, are investigated. Complex nozzle exhaust flows induced by the secondary jet penetration is numerically analyzed by solving unsteady three-dimensional Reynolds-averaged Navier-Stokes equations with Baldwin-Lomax turbulence model for closure. Numerical simulations compared with the experiments of secondary air injection into the rocket nozzle of $9.6^{\cire}$ divergent half angle showed good agreement. The results obtained in terms of overall performance parameters showed that locating the secondary injection orifice further downstream of primary nozzle ensures the prevention of occurrence of reflected shock wave, therefore is suitable for efficient and stable thrust vectoring over a wide range of use.

  • PDF

Analysis of the 2022 Revised Science Curriculum Grades 3-4 Achievement Standards Based on Bloom's New Taxonomy of Educational Objectives and Comparison to the 2015 Revised Curriculum (Bloom의 신교육목표분류에 따른 2022 개정 과학과 교육과정 초등학교 3~4학년군 성취기준 분석 및 2015 개정 교육과정과의 비교)

  • Kim, Woo-Joong;Kim, Dong-Suk;Shin, Young-Joon;Kwon, Nan-Joo;Oh, Phil-Seok
    • Journal of Korean Elementary Science Education
    • /
    • 제43권3호
    • /
    • pp.353-364
    • /
    • 2024
  • The purpose of this study is to analyze the achievement standards for grades 3-4 of the 2022 revised science curriculum and identify the goals of science education for grades 3-4 of the 2022 revised curriculum, as well as provide implications for the development of the science textbooks for grades 3-4 and the direction of teaching for teachers in the field. For this purpose, 57 achievement standards of the Science Department 2022 revised curriculum for grades 3-4 were analyzed as to their knowledge dimensions and cognitive processes according to Bloom's Taxonomy of the New Educational Objectives. In cases where an achievement standard is a double sentence or combines two or more knowledge dimensions or cognitive process dimensions, we separated the sentences after having consulted with a group of experts and divided the achievement standards into 57 sentences. We then analyzed the frequency of the categorization of concepts and descriptors by comparing them with the previously studied elementary science standards from the 2015 revised curriculum. The main findings of the study are as follows. First, in the knowledge dimension, the "factual knowledge" accounted for 50 items (86%), compared to "conceptual knowledge" (10%), and "procedural knowledge" (4%), and "metacognitive knowledge" was not analyzed at all. Second, in terms of the cognitive processes, "Understanding" was the highest at 60% with 34 items. It was followed by "applying" with 11%, "creating" with 19%, "evaluating" with 15%, and "analyzing" and "remembering" with 6%. Third, when analyzing the descriptors, "I can explain" was the highest with 9%, followed by "comparison" with 6%, and "practice" and "classification" with 5%. Fourth, compared to the 2015 revised curriculum, "conceptual knowledge" was reduced and "factual knowledge" was overwhelmingly increased. Fifth, in the cognitive process dimension, "understanding,' has increased significantly, while the other cognitive process dimensions have decreased. Conclusions and implications based on these findings are as follows: the focus of the Science Department for grades 3-4 in the 2022 revised curriculum is heavily weighted toward the "factual knowledge," with "understanding" dominating the cognitive process dimensions. As a result, many concepts and applications have been reduced. Based on the results of the comparison of the descriptors with the results of the 2015 revised curriculum, the implications for the development of the science textbooks for grades 3-4 of the 2022 revised curriculum were discussed, and so were the implications of the curriculum for the field.

Two-dimensional Velocity Measurements of Campbell Glacier in East Antarctica Using Coarse-to-fine SAR Offset Tracking Approach of KOMPSAT-5 Satellite Image (KOMPSAT-5 위성영상의 Coarse-to-fine SAR 오프셋트래킹 기법을 활용한 동남극 Campbell Glacier의 2차원 이동속도 관측)

  • Chae, Sung-Ho;Lee, Kwang-Jae;Lee, Sungu
    • Korean Journal of Remote Sensing
    • /
    • 제37권6_3호
    • /
    • pp.2035-2046
    • /
    • 2021
  • Glacier movement speed is the most basic measurement for glacial dynamics research and is a very important indicator in predicting sea level rise due to climate change. In this study, the two-dimensional velocity measurements of Campbell Glacier located in Terra Nova Bay in East Antarctica were observed through the SAR offset tracking technique. For this purpose, domestic KOMPSAT-5 SAR satellite images taken on July 9, 2021 and August 6, 2021 were acquired. The Multi-kernel SAR offset tracking proposed through previous studies is a technique to obtain the optimal result that satisfies both resolution and precision. However, since offset tracking is repeatedly performed according to the size of the kernel, intensive computational power and time are required. Therefore, in this study, we strategically proposed a coarse-to-fine offset tracking approach. Through coarse-to-fine SAR offset tracking, it is possible to obtain a result with improved observation precision (especially, about 4 times in azimuth direction) while maintaining resolution compared to general offset tracking results. Using this proposed technique, a two-dimensional velocity measurements of Campbell Glacier were generated. As a result of analyzing the two-dimensional movement velocity image, it was observed that the grounding line of Campbell Glacier exists at approximately latitude -74.56N. The flow velocity of Campbell Glacier Tongue analyzed in this study (185-237 m/yr) increased compared to that of 1988-1989 (140-240 m/yr). And compared to the flow velocity (181-268 m/yr) in 2010-2012, the movement speed near the ground line was similar, but it was confirmed that the movement speed at the end of the Campbell Glacier Tongue decreased. However, there is a possibility that this is an error that occurs because the study result of this study is an annual rate of glacier movement that occurred for 28 days. For accurate comparison, it will be necessary to expand the data in time series and accurately calculate the annual rate. Through this study, the two-dimensional velocity measurements of the glacier were observed for the first time using the KOMPSAT-5 satellite image, a domestic X-band SAR satellite. It was confirmed that the coarse-to-fine SAR offset tracking approach of the KOMPSAT-5 SAR image is very useful for observing the two-dimensional velocity of glacier movements.

Use of Audio-Band on the Interpretation of Magnetotelluric Data (MT 탐사자료의 해석에서 AMT 대역 자료의 효용성)

  • Lee, Tae-Jong;Lee, Seong-Kon;Song, Yoon-Ho;Uchida, Toshihiro
    • Geophysics and Geophysical Exploration
    • /
    • 제9권4호
    • /
    • pp.261-270
    • /
    • 2006
  • Two-dimensional (2-D) inversion of magnetotelluric (MT) data for two survey lines having south-north direction from Jeju Island has been carried out. Broad band MT sounding curves with good quality could be gathered by performing audio-frequency magnetotelluric (AMT) survey during the MT survey and by operating the remote reference in Kyushu Island, Japan. Comparison of the 2-D inversion model using MT band only and that using both AMT and MT bands for the field data as well as for the data from numerical 2-D modeling said that high frequency information from AMT survey can be useful for interpreting not only the shallow part but also the deep structures, especially when the formation is resistive. The 2-D inversion models of field data show a thick layer having around 10 ohm-m in the depth of a few hundred meters throughout the survey area, which can be considered as the unconsolidated sedimentary layer. And they also show a conductive anomaly at the central part of each survey lines. It can be either the effect of the surrounding sea water, or the structures due to ancient volcanic events. But unfortunately by now, we do not have any further information about the anomaly.

Hydraulic Impact Analysis of Geum River with the Operation of Diversion Tunnel for Low Flow Augmentation of Boryong Dam (금강-보령댐 도수터널 운영에 따른 수리영향 분석)

  • JANG, Suk-Hwan;OH, Kyung-Doo;OH, Ji-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.359-359
    • /
    • 2016
  • 본 연구에서는 최근 기후변화에 따른 가뭄으로 어려움을 겪고 있는 충청남도 서부권의 물 부족을 해결하기 위하여 금강 본류로부터 보령댐으로 일정 유량을 도수(diversion)하는 계획이 금강 본류에 미치는 수리적 영향을 검토하였으며 특히 금강 본류의 농공용수 취수에 제한을 초래할 수 도 있는 수위에 미치는 영향을 중심으로 분석하였다. 본 연구의 공간적 범위는 금강 하굿둑으로부터 하류 외해 방향으로 약 9km 지점에 위치한 금강 하구로부터 상류 방향으로는 금강 하굿둑으로부터 약 76km 지점에 위치한 공주시 반포면 검상동의 검상천 합류지점까지 총 85km에 이르는 구간에 대한 1차원 수리 모형을 구축하였으며, 시간적 범위는 보령댐으로의 도수가 갈수기에 이루어지는 것으로 가정하여 2015년 2월 1일부터 5월 31일까지 진두수위표의 시간별 유량과 8개 지천의 유입 유량, 장항검조소의 시간별 조위, 농공용수 취수시설 취수량 및 회귀수, 금강 배수갑문 운영 등을 고려하여 모형의 보정을 실시하였고, 유황분석에 따른 2016년 갈수기 예측 유량을 추정하여 보령댐으로의 도수에 따라 금강 본류 내 주요 구간의 수위에 미치는 영향을 분석하고자 하였으며, 서해안 조위에 따른 금강하굿둑 배수갑문의 운영에 직접적인 영향을 받는 배수위 구간임을 감안하여 비정상류 해석(unsteady flow analysis)을 수행하였다. 갈수기 예측 유량 추정 결과 2015년과 같은 가뭄이 지속될 경우, 2016년의 유황은 2015년 대비 21%로 분석되었으며 이는 보령댐 도수 여부에 관계없이 물 부족이 발생할 수 있는 상태인 것으로 분석되었고, 하천유지유량 정도의 유황이 유지되는 상태에서 보령댐으로 도수를 실시할 경우, 도수시 금강호 최저 수위는 각각 EL(+)0.94m와 EL(+)0.72m로 모의되어 농업용수를 비롯한 기존 취수시설 뿐만 아니라 보령댐 도수시설의 운영에도 어려움이 생길 것으로 예상되었다. 2016년 갈수기 동안 과업 대상 구간인 금강 하류부의 유황은 농업용수 취수가 본격화되기 이전인 2월에는 하천유지유량 정도의 유황을 유지하는데 별 어려움이 없지만 3월 이후농업용수 취수가 본격화되면 농업용수 취수시설이 집중된 입포수위표 ~ 금강 하굿둑 사이 구간은 하천유지유량 이하로 유량이 크게 감소할 것으로 예상되었다.

  • PDF

Examination of Dose Change at the Junction at the Time of Treatment Using Multi-Isocenter Volumetric Modulated Arc Therapy (용적조절호형방사선치료(VMAT)의 다중치료중심(Multi- Isocenter)을 이용한 치료 시, 접합부(Junction)의 선량 변화에 대한 고찰)

  • Jung, Dong Min;Park, Kwang Soon;Ahn, Hyuk Jin;Choi, Yoon Won;Park, Byul Nim;Kwon, Yong Jae;Moon, Sung Gong;Lee, Jong Oon;Jeong, Tae Sik;Park, Ryeong Hwang;Kim, Se young;Kim, Mi Jung;Baek, Jong Geol;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제33권
    • /
    • pp.9-14
    • /
    • 2021
  • This study examined dose change depending on the reposition error of the junction at the time of treatment with multi-isocenter volumetric modulated arc therapy. This study selected a random treatment region in the Arccheck Phantom and established the treatment plan for multi-isocenter volumetric modulated arc therapy. Then, after setting the error of the junction at 0 ~ 4 mm in the X (left), Y (upper), and Z (inner and outer) directions, the area was irradiated using a linear accelerator; the point doses and gamma indexes obtained through the Phantom were subsequently analyzed. It was found that when errors of 2 and 4 mm took place in the X and Y directions, the gamma pass rates (point doses) were 99.3% (2.085) and 98% (2.079 Gy) in the former direction and 98.5% (2.088) and 95.5% (2.093 Gy) in the latter direction, respectively. In addition, when errors of 1, 2, and 4 mm occurred in the inner and outer parts of the Z direction, the gamma pass rates (point doses) were found to be 94.8% (2.131), 82.6% (2.164), and 72.8% (2.22 Gy) in the former part and 93.4% (2.069), 90.6% (2.047), and 79.7% (1.962 Gy) in the latter part, respectively. In the X and Y directions, errors up to 4 mm were tolerable; however, in the Z direction, error values exceeding 1 mm were beyond the tolerance level. This suggests that for high and low dose areas, errors in the direction same as the progress direction in the treatment region have a more sensitive dose distribution. If the guidelines for set-up errors are established at the institutional level through continuous research in the future, it will be possible to provide good quality treatment using junctions.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • 제38권4호
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.