• Title/Summary/Keyword: 2방향 장력측정

Search Result 11, Processing Time 0.021 seconds

Development of Measuring System of Membrane Stress for Membrane Structure (막구조물의 막장력 측정장치 개발에 관한 연구)

  • Jung, Hwan-Mok;Woo, Jae-Won;Cho, Byung-Wook;Lee, Seong-Yeun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.6
    • /
    • pp.67-74
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one.

  • PDF

실선의 선체저항 측정에 관한 연구

  • Jeong, Chang-Hyeon;Nam, Taek-Geun;Kim, Cheol-Seung;Kim, Jin-Man
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.06a
    • /
    • pp.17-19
    • /
    • 2014
  • 해양사고 발생 직후 2차적인 피해로의 확산을 방지하기 위한 조치로 사고선박을 안전한 장소로 이동하게 된다. 사고선박의 크기와 상태 그리고 해상조건을 고려하여 예선의 크기와 척수가 결정된다. 이 과정에서 사고선박의 선체저항을 계산하게 되는데, 기존의 이론식을 적용하여 계산하고 이에 대한 검증 단계로 예인실험을 실시하였다. 대상선박은 목포해양대학교 실습선 새유달호이며, 장력계, 외력 측정장치 등 실험장치는 실습선에 탑재하여 계측하였다. 실험장소는 목포해양대학교 인근 묘박지이며, 당시 풍속은 7m/s, 조류는 0.7m/s 전후이었으며, 횡방향 예인, 전방 2척 예인, 전 후방예인, 프로펠러고착, 예인속력의 변화 등 다양한 시나리오에 대하여 실험을 실시하였다. 장력의 계측은 예선의 예인삭을 사용하였으며, 실습선 선수미 비트에 장력계를 연결하여 측정하였고, 장력계의 최대측정 범위는 20톤을 사용하였다. 예인속력은 정지에서 3m/s까지 단계적으로 증가시키면서 해당 속력별 장력을 계측하여 속력증가에 따른 예인력을 확인하였다. 최종적으로 이론계산 결과와 실선실험 결과를 상호 비교하여 이론계산식의 유효성을 검증하였다.

  • PDF

Effects on Tensile Strength and Elasticity after Treatment with Glutaraldehyde, Solvent, Decellularization and Detoxification in Fresh Bovine Pericardium (소의 심낭 고정에서 용매 처치, 무세포화 혹은 항독성화 처치가 조직의 장력 및 신장도에 미치는 영향)

  • Jang, Woo Sung;Kim, Yong Jin;Kim, Soo Hwan
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Background: Bioprosthetic materials have been made using glutaraldehyde fixation of porcine or bovine pericardium during cardiovascular surgery. But these bioprostheses have the problems of calcification and mechanical failure. We determined changes in tensile strength and elasticity of pericardium after glutaraldehyde, solvent, decellularization and detoxification. Material and Method: Tissues were allocated to four groups: glutaraldehyde with and without solvent, decellularization, and detoxification. We studied tensile strength and strain on tissues. We measured the tensile strength of fresh pericardium stretched in six directions (with 5 mm width), and % strain, which we calculated from the breaking point when we pulled the pericardium in two directions. Result: Tensile strength was reduced when we used the usual concentrated glutaraldehyde fixation (n=83, $MPa=11.47{\pm}5.40$, p=0.006), but there was no change when we used solvent. Elasticity was increased after glutaraldehyde fixation (n=83, strain $(%)=24.55{\pm}9.81$, p=0.00), but there was no change after solvent. After decellularization of pericardium, the tensile strength was generally reduced. The decrease in tensile strength after concentrated glutaraldehyde fixation for a long time was significantly greater less than after concentrated solvent (p=0.01, p=0.00). After detoxification, the differences in strength and strain were not significant. Conclusion: After glutaraldehyde treatment of pericardium there is no loss in tensile strength (even though we did the glutaraldehyde, solvent and detoxification treatments LOGIC IS UNCLEAR). Also, these treatments had a tendency to increase elasticity. Although post-treatment decellularization led to a significant loss in strength, this effect could be attenuated using a low concentration of solvent or hypertonic solution.

Study on Basic Magnetic Characteristics in New Magnetic Materials(2) - Magnetic Properties of Amorphous $Fe_{80}B_{15}Si_{5}$ alloy Measures with Pulse Method (새 자성재료의 기초자기특성 연구(2) - 펄스측정법에 의한 비정질 $Fe_{80}B_{15}Si_{5}$ 합금의 자기특성)

  • 이용호;신용돌;김인수;이연숙;노태환;강일구
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.42-48
    • /
    • 1991
  • The basic soft magnetic characteristics of a typical Fe based amorphous $Fe_{80}B_{15}Si_{5}$ alloy were measured with pulse metheod. Quantitative relations between magnetostriction, anisotropy energy, reluctivity were investigated. The relative contribution factor of magnetostrictive and uniaxial anisotropy energy to the reluctivity were calculated. The internal stress and induced anisotropy were estimated. A tension applied to the long axis of the sample greatly enhanced induced anisotropy.

  • PDF

Dynamic Behavior of Model Set Net in the Flow (모형 정치망의 흐름에 대한 거동)

  • Jung, Gi-Cheul;Kwon, Byeong-Guk;Le, Ju-Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.275-284
    • /
    • 1997
  • This experiment was carried out to measure the sinking depth of each buoy, the change in the net shape of the net, and the tension of sand bag line according to the R (from bag net to the fish court) and L (from fish court to the bag net) current directions and their velocity by the model experiment. The model net was one-fiftieth of the real net, and its size was determined after considering the Tauti’s Similarity Law and the dimension of the experimental tank. 1. The changes of the net shape were as follows : In the current R, the end net of fish court moved 20mm down the lowerward tide and 10mm upper part. So the whole model net moved up at 0.2m/sec. The shape of the net showed an almost linear state from bag net to the fish court at 0.6m/sec. In the current L, the door net moved 242mm down the lowerward tide and 18mm upper part. So the whole model net moved up at 0.2m/sec. The net shape showed an almost linear state from the fish court to the bag net at 0.5m/sec. 2. The sinking depths of each buoy were as follows: In the current R, the head buoy started sinking at 0.2m/sec and sank 20mm, 99mm at 0.3m/sec and 0.6m/sec, respectively. The end buoy didn't sink from 0m/sec to 0.6m/sec but showed a slight quake. In the current L, the end buoy started sinking at 0.1m/sec, and sank 5mm and 108mm at 0.2m/sec and 0.6m/sec, respectively. The whole model net sank at 0.5m/sec except the head buoy. 3. The changes of the sand bag line tension were as follows: In the current R, the tension affected by the sand bag line of the head buoy showed 273.51g at 0.1m/sec increased to 1298.40g at 0.6m/sec. In the current L, the tension affected by the sand bag line of the end buoy on one side showed 137.08g at 0.1m/sec increased to 646.00g at 0.6m/sec. The changes in the sand bag line tension were concentrated on the sand bag line of the upperward tide with increasing velocity at the R and L current directions. However, no significant increase in tension was observed in the other sand bag lines.

  • PDF

Development and Application of Non-Contact Rock Fall Detection System utilizing Photo Sensor and Camera (광센서와 카메라를 활용한 비접촉식 낙석감지 시스템 개발 및 적용)

  • Jung, Yong-Bok;Song, Won-Kyong;Kim, Bok-Chul;Kim, Myung-Jin
    • Tunnel and Underground Space
    • /
    • v.20 no.3
    • /
    • pp.207-216
    • /
    • 2010
  • Rockfall monitoring systems generally used in the country are mainly based on the detection of tension of protection wire or tilting of protection post due to rock fall. However, rock fall protection net must be installed prior to the monitoring system and continual maintenance work after each rock fall event is required for a normal operation of these detection systems. To solve these problems, we suggested and implemented a non-contact rock fall detection system using multiple photo sensors and additional camera. After a laboratory experiment and field application, we can conclude that this system is effective and reliable for detecting, collecting and analyzing the rock fall information. In addition, lighten and difference operations on two captured images were able to yield rough estimation of size and direction of rock fall.

Development of Tilt angle measurement system of plastic thin-film using Position Sensitive Device (PSD를 이용한 플라스틱 박막 필름의 경사 각도 측정 시스템 개발)

  • Kim, Gi-Seung;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.134-138
    • /
    • 2021
  • Various types of precision plastic thin films are used widely in high-performance displays, such as smartphones. For plastic thin-films manufactured by the Roll-to-Roll process, the film thickness must be measured and managed while moving. In the Roll-to-Roll process, wrinkles are generated when tension is applied to the film, which causes an inclination on the optical axis of the thickness gauge, resulting in a loss of accuracy. Therefore, this study attempted to develop an optical interference tomography measurement system. In this study, the tilt angle of the film was measured to correct the measurement value error in the thickness gauge caused by the tilt of the film. The system was constructed so that the laser was irradiated on the tilted film, and the laser reflected from the film was formed on the PSD. The relationship between the tilt angle of the film and the output value of the PSD was obtained experimentally. Using this, a device to measure the tilt angle of the film was constructed, and angle measurements were taken at a speed of 250,000Hz.

Effect of Preparation Conditions of PAN-based Carbon Fibers on Electrochemical Characteristics of Rechargeable Lithium ion Battery Anode (PAN계 탄소섬유 제조조건에 따른 리튬이온 이차전지 음극의 전기화학적 특성)

  • An K. W.;Lee J. K.;Lee S. W.;Kim Y. D.;Cho W. I.;Ju J. B.;Cho B. W.;Park D. G.;Yun K. S.
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.2
    • /
    • pp.81-87
    • /
    • 1999
  • Poly-acrylonitrile (PAN) based carbon fibers were stabilized under various tensions in the presence of air at about $200^{\circ}C$ and sequentially carbonized under some different gas environments in the range of 700 to $1500^{\circ}C$. The prepared carbon fibers were used for rechargeable lithium ion battery anode to investigate preparation parameters effects on electrochemical characteristics. It was found that the tension during stabilization, carbonization temperature and gas atmospheres affect the carbon fiber properties such as conductivity, mechanical strength, surface morphology and diffusion coefficient of lithium ion, which are closely related to the on electrolchemical properties as well as the charge/discharge characteristics.

Studies on the Improvement of the Fishing Efficiency of Purse Seine in the Sea Area of Cheju Island -The Changes of Seine Volume and Tension in the Purseline During Pursing- (제주도 주변해역 선망의 어획성능 향상에 관한 연구 -짐줄 체결 중 선망의 용적과 짐줄의 장력 변화 -)

  • 김석종
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • A simple experimental method was used in an attempt to realize the elevation of the fishing ability of purse seine in the sea area of Cheju Island, the changes of seine volume and tension in the purseline during pursing. Experiments carried out on the six types simplified reduced model seines which were made of knotless nettings. The nettings were woven in different leg length 4.3, 5.0, 5.5, 6.0, 6.6 and 7.7mm of polyester 28 tex two threads two-ply twine, and each of the seines were named I, II, III, IV, V and Ⅵ seine. Dimension of seine models were 450cm for corkline and 85cmfor seine depth, each seines rigged up 160g of float for a floatline and 50g (underwater weight) of lead for a leadline. These model purse seines were made of the scale of 1/200 of its full scale, a 120 ton in the near sea of Cheju Island. Designing and testing for the model purse seines were based on the Tauti's law. Experiments were measured in the observation channel of a flume tank at the static conditions set up shooting and pursing equipments. Motion of purse seine during purse line was recorded by the two sets video camera for VTR which were placed in top and front of the model seine. The reading coordinate of seine volume carried out by the video digitization system, disk data for the purseline tension. An analysis were performed on the changes seine volume and tension in the purseline during pursing. The results obtained were as follows: 1. The seine volume during pursing was largest for Ⅵ seine with smallest d/l followed by V, IV, III, II and I seines, and tension in the purseline was small. 2. Seine volume during pursing can be expressed by the following equation; CVt=l-EXP[{2.79 (d/l)+0.35}t-33.37 (d/l) + 0.57] Where CVt is volume ratio, d is twine diameter, l is leg length and t is pursing time (sec). 3. Tension in the purse line during pursing can be expressed by the following equation; T= 1- EXP {0.57t + 13.36 (d/l)+2.97} Where T is tension (kg) in the purseline during pursing.

  • PDF

A Study on the Dynamic Behavior Characteristics of a Small Fishing Crane (소형 어로 크레인의 동적 거동 특성에 관한 연구)

  • 이원섭;이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.163-173
    • /
    • 2001
  • The dynamic behavior characteristics of a small fishing crane for inshore and coastal fishing vessels was experimentally analyzed in order to improve the fishing operation and to reduce considerably manual work of fisherman. The small fishing crane was designed to be controlled electro-hydraulically by means of proportional valves and solenoid valves, and also to be controlled the speed of each operation. The dynamic behavior characteristics was investigated by measuring the changes of parameters such as oil pressure, swing angle of load, load tension, the lifting angle and the swing angle of crane arm when the arms extended in a side way was given a test load. The results obtained are summarized as follows: 1. The designed small fishing crane can be proportionally controlled by means of proportional valves and rapidly by operating the solenoid valves, respectively. The capacity, turning angle, maximum reach of crane were 2 T-M, $180^\circ$, 3.7m, respectively. 2. The vertical change of crane arm on the extension of lifting cylinder was $1.2^\circ$/cm, and the swing speed of crane arm due to the extension of swing cylinder by on/off operations of solenoid valves was $15^\circ$/sec, with the swing period of 1.4 sec and the angle fluctuation of $\pm$11.0$^{\circ}$. 3. When changing simultaneously the horizontal and vertical positions of the lifting load by on/off operations of solenoid valves, the swing and lifting speeds of crane arm were $4.46^\circ$/sec and $6.4^\circ$/sec, respectively. 4. The movements of the designed crane were particularly smooth as they are controlled with the aid of proportional valves than by means of solenoid valves.

  • PDF