• Title/Summary/Keyword: 19-gauge

Search Result 134, Processing Time 0.024 seconds

Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration

  • Mitsuru Okuno;Keisuke Iwata;Tsuyoshi Mukai;Yusuke Kito;Takuji Tanaka;Naoki Watanabe;Senji Kasahara;Yuhei Iwasa;Akihiko Sugiyama;Youichi Nishigaki;Yuhei Shibata;Junichi Kitagawa;Takuji Iwashita;Eiichi Tomita;Masahito Shimizu
    • Clinical Endoscopy
    • /
    • 제57권3호
    • /
    • pp.364-374
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML). Methods: Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles. Results: Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1-6] vs. 4 [1-6], p=0.023). There were no significant differences in cytological/ histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group. Conclusions: Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.

최적화 기법을 통한 강우관측소의 고도별 분포특성 검토 (Evaluation of Rain Gauge Distribution Characteristics by Altitude using Optimization Technique)

  • 이지호;김종근;주홍준;전환돈
    • 한국습지학회지
    • /
    • 제19권1호
    • /
    • pp.103-111
    • /
    • 2017
  • 본 연구에서는 강우관측소의 고도별 공간분포의 적정성을 평가하기 위한 방안으로 고도별 강우관측소의 최근린지수를 산정하고, 현재 강우관측소 공간분포의 적정성을 평가하였다. 등면적비를 이용하여 고도를 구분하고, 고도마다 다른 지형적인 조건을 고려하기 위하여 주어진 지형조건내에서 가능한 최대 NNI을 최적화 기법의 하나인 화음탐색법을 이용하여 산정하였다. 이와 같이 고도별로 현재 상태 및 최대 NNI를 산정한 후 이 두 값의 차이를 바탕으로 고도별로 강우관측소 분포를 평가하였다. 그 결과 고도가 높아질수록 공간분포가 상대적으로 취약함을 확인하였다. 추후 강우관측망을 신설할 경우 고도별 특성을 반영한다면 보다 효율적인 강우관측망의 구축이 가능할 것으로 판단된다.

가을철 대기환경 중 수용성 이온성분의 침적특성 (Deposition Characteristics of Water-soluble Inorganic Ions in the Iksan Ambient Air during Fall, 2004)

  • 강공언;김남송;전선복
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.359-372
    • /
    • 2006
  • In order to investigate the daily deposition characteristics of water-soluble inorganic components in airborne deposit on the Iksan, deposition samples were collected using a deposition gauge from October 16 to November 1, 2004. Deposition samples were collected using two different sampling gauges, a dry gauge and a wet gauge, respectively. To get wet the bottom of wet gauge during the sampling period, the volume of $30{\sim}50ml$ distilled ionized water was added in a wet gauge before the beginning of each deposition sampling. Deposition samples were collected twice a day and analyzed for inorganic water-soluble anions ($Cl^-,\;{NO_3}^-,\;{SO_4}^{2-}$) and cations (${NH_4}^+,\;Na^+,\;K^+,\;Mg^{2+},\;Ca^{2+}$) using ion chromatography. Qualify control and quality assurance of analytical data were checked by the data obtained from reinjection of standard solution, Dionex cross check standard solutions, and random several deposition samples, and measured data was estimated to be reliable. Considering the deposition sample volume, the sampling time, the surface area of sampling container, and the ion concentration measured, the daily deposition amounts for measured ions were calculated in $mg/m^2$. The total daily deposition amounts of all measured ions for dry and wet gauge were $7.5{\pm}2.8$ and $17.7{\pm}4.2mg/m^2$, respectively. A significant increase in deposition amount during rainfall days was observed for both wet gauge and dry gauge, having no difference of deposition amount between in wet gauge and in dry gauge. The mean deposition of all ions measured in this study were higher in wet gauge than in dry gauge because of the surface difference of the sampling container, especially for ${NH_4}^+\;and\;{SO_4}^{2-}$. The mean deposition amounts of ${NH_4}^+\;and\;{SO_4}^{2-}$ in wet gauge were found to be about 10 times and 3 times higher than those in dry gauge, while the rest of the chemical species were equal or a little higher in wet gauge than in dry gauge. Dominant species in dry gauge were ${NO_3}^-\;and\;Ca^{2+}$, accounting for 21% and 28% of the total ion deposition, whereas those in wet gauge were ${SO_4}^{2-}\;and\;{NH_4}^+$, accounting for 19% and 41% of the total ion deposition, respectively.

기본 자카드 조직의 게이지 변화에 따른 특성에 관한 연구 (A Study on the Gauge Types Comparative Analysis of Basic Jacquard Structure)

  • 기희숙
    • 한국의상디자인학회지
    • /
    • 제19권4호
    • /
    • pp.1-15
    • /
    • 2017
  • The aim of this study is to plan a design that satisfies consumer needs by forecasting future properties following changes of gauge in basic Jacquard structure and to provide helpful data for a variety of knit-wear development. Four basic Jacquard knit samples (Normal Jacquard, Bird's eye Jacquard, Floating Jacquard, Tubular Jacquard) were selected and projected by using three types of gauges (7G, 12G, 14G) with an SES-122S type Computer Knitting machine of Shimaseiki MFG. Twelve different types of samples with Jacquards and gauges were tested on a flat table by measuring the course and wale in a 1cm area to calculate the gauge of samples. The mechanical properties of 12 types of Jacquard samples were measured using KES-FB (Kawabata Evaluation System for Fabric, Kata Tech Co. Ltd). As the result of comparing the number of patterns, courses and wales depending on the change of gauge of the basic Jacquard structure, it was observed that the number of patterns per specific length, course and wale has increased from 7G to 14G, a high-gauge. According to objective research regarding Jacquard structure, 7G Tubular Jacquard, which is low gauge, seems to be suitable for masculine design as it is heavy and thick, and has rigid and rough texture due to a high level of flexural strength and shear property. 14G Floating Jacquard, which is high gauge, seems to be suitable for feminine, silhouette design as it is light, thin, soft, flexible and has high drape. The result of this study provides a theoretical foundation for knit-wear development considering basic Jacquard structure and gauge-specific properties. This study can be used to provided directions for the development of knit industry.

  • PDF

금망임펠러를 이용한 교반조에서의 기-액 물질이동 (Mass Transfer of Gas-Liquid in Agitated Vessel Using Wire Gauge Impeller)

  • 이영세
    • 한국산업융합학회 논문집
    • /
    • 제11권1호
    • /
    • pp.19-26
    • /
    • 2008
  • The gas-liquid mass transfer volumetric coefficients in gas-liquid agitated vessels with wire gauge impellers were measured to be compared with those in vessels with disk turbine and paddle impellers. Also mass transfer volumetric coefficients for disk turbine, paddle impeller and wire gauge impeller in cylindrical agitated vessel was measured over a wide range of Reynolds number from turbulent flow to transition regions. The effect of geometries on $k_La$ is clarified experimentally. Mass transfer volumetric coefficients $k_La$ depends only on the power consumption ($P_{gv}+P_{av}$) per unit volume.

  • PDF

강재 급속냉각용 고온 열유속게이지 개발 (Development of High-Temperature Heat Flux Gauge for Steel Quenching)

  • 이정호
    • 열처리공학회지
    • /
    • 제23권6호
    • /
    • pp.323-330
    • /
    • 2010
  • The present study was motivated by increasing demands on quantitative measurements of the heat flux through the water cooling and quenching process of hot steel. The local heat flux measurements are employed by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are directly used to measure the heat flux variation during water cooling and quenching of hot steel. The heat flux can be directly achieved by Fourier's law and is also compared with numerical estimation which is solved by inverse heat conduction problem (IHCP). The high-temperature heat flux gauge developed in this study can be applicable to measure cooling rate and history during the actual cooling applications of steelmaking process. In addition, the measurement uncertainty of heat flux is calculated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard.

광섬유 스마트 구조물의 개념을 이용한 교량상부 내진거동 측정 (Earthquake Movement Measurement of the Top of Bridge Pier Using Fiber Optic Smart Structure Concept)

  • 김기수;한인동
    • Composites Research
    • /
    • 제19권3호
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, a long gauge Fiber Bragg Grating (FBG) sensor system is described and long gauge FBGs are well-suited for measuring the upper parts of the bridge piers under the extremely severe movement conditions. In the experiments, we used more than 30m long FBG sensors to measure the movement of top part of the bridge piers which are separated from the main bridge by cutting the decks. With the actuator, the deck and girders were pushed and released. We checked the movement of the top of the pier while releasing the pressure of the actuator with the long gauge fiber sensor. In order to measure the movement of the upper part of the pier, the reference point must be outside of the pier. Using the optical fiber sensors, one end of the sensor is attached to the top of the pier and the other end is attached to the bottom of the next pier. The fiber sensors showed good response to the release loading and we could calculate the movement of the top part of the pear.

동아시아 주변해역에서의 TOPEX/POSEIDON 위성 고도자료와 Tide Gauge 현장자료 간의 비교 및 해석 연구 (Comparison and analysis between TOPEX/POSEIDON Altimeter data and In-Situ Tide Gauge Data in the Eastern Asian Marginal Seas)

  • 윤홍주
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.606-609
    • /
    • 2000
  • T/P자료를 처리한 결과, M$_2$, S$_2$ 분조에 의한 주기가 62.1일, 58.7일의 조석변형 오차와 Kl 분조에 의한 173.2일 주기의 조석변형 오차가 나타났다. 따라서 이러한 오차의 영향들을 제거하기 위하여 가우시안 필터를 사용하여 200일에 대한 lowpass liter를 행하였다. 이때 전 조위관측점들에 대한 RMS의 평균값은 4.19 cm 이고 상관계수의 평균간 0.9로 나타났다. 특히 상관계수값은 우리나라의 서귀포와 일본의 Chichijima에서 0.96으로 가장 높게 나타났다.

  • PDF

공작기계 기술의 현재와 미래(8) (MACHINE TOOL TECHNOLOGY;THE PRESENT AND THE FUTURE(8))

  • 강철희
    • 한국정밀공학회지
    • /
    • 제12권11호
    • /
    • pp.5-19
    • /
    • 1995
  • 항공기 기술의 발전은 다양한 과학기술 분야의 발달에 끊임없이 큰 영향을 주어왔고, 또 기기서 파생된 신 기술도 수없이 발생하였다. NC 공작기계도 그 하나이다. 제 2차 세계대전 후 미공군은 복잡한 형상의 항공기 부품가공과 고정밀도의 검사용 Gauge를 제작할 필요성을 얻게 되었다. Helicopter의 Rotor blade의 Prifile 검사용 Plate gauge를 가공할 수 있는 기계를 개발 중에 있었던 J.T.Person이 Jig boring machine을 저자적으로 제어하면서 Gauge를 가공하는 방법을 1947년 미공군에 제안하게 되었다. 이것이 NC 발달사에 기록된 역사적인 사실이며 이 Project는 후에 MIT로 넘아가고 1952년에 NC milling machine을 완성시켰다. 그 후, 1955년 Gidding & Lewis사가 최초로 NC 공작기계를 공업화한 제1호기 Numericord를 시장에 내 놓게 되었다.

  • PDF

전도형 강수량계의 성능시험 및 불확도 분석 (Performance tests and uncertainty analysis of tipping bucket rain gauge)

  • 홍성택;박병돈;신강욱;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 춘계학술대회
    • /
    • pp.595-597
    • /
    • 2018
  • 강수량의 계측은 댐 및 하천의 안정적인 운영 및 유지관리, 도시 및 산업단지의 먹는 물 및 용수공급, 농어촌의 영농 및 산림녹화 등 광범위한 범위에서 필요로 하고 있으며, 재난재해를 대비하고 강우 발생시 경제적인 효과를 얻기 위해서는 정확한 강수량의 측정이 필요하다. 본 연구에서는 강수량계의 성능을 분석할 수 있는 교정시스템을 이용하여 전도형 강수량계에 대한 강우강도 20 ~ 100 mm/h에 대한 특성시험을 실시하였으며, 측정값은 19.30 ~ 19.59 mm, 오차율은 0.31 ~ 0.35 mm로 측정되었으며, 불확도는 0.2887 mm로 산출되었다. 이러한 특성시험을 통하여 기상 및 수문 관측 데이터의 신뢰성을 확보하고자 하였다.

  • PDF