• Title/Summary/Keyword: 19-gauge

Search Result 134, Processing Time 0.02 seconds

Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration

  • Mitsuru Okuno;Keisuke Iwata;Tsuyoshi Mukai;Yusuke Kito;Takuji Tanaka;Naoki Watanabe;Senji Kasahara;Yuhei Iwasa;Akihiko Sugiyama;Youichi Nishigaki;Yuhei Shibata;Junichi Kitagawa;Takuji Iwashita;Eiichi Tomita;Masahito Shimizu
    • Clinical Endoscopy
    • /
    • v.57 no.3
    • /
    • pp.364-374
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML). Methods: Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles. Results: Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1-6] vs. 4 [1-6], p=0.023). There were no significant differences in cytological/ histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group. Conclusions: Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.

Evaluation of Rain Gauge Distribution Characteristics by Altitude using Optimization Technique (최적화 기법을 통한 강우관측소의 고도별 분포특성 검토)

  • Lee, Ji Ho;Kim, Jong Geun;Joo, Hong Jun;Jun, Hwan Don
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.103-111
    • /
    • 2017
  • In this study, we estimate the NNI(Nearest Neighbor Index) which is considered altitude of rain gauge network as a method for evaluating appropriateness of spatial distribution and the current rain gauge network is evaluated. The altitude is divided by equal-area-ratio and optimal NNI within given basin condition is estimated using harmony search method for considering geographical conditions that vary from altitude to altitude. After calculating current state and optimal NNI for each altitude, the distribution of the rain gauge network is evaluated based on the difference between the two NNIs. As a result, it founds that the density of rain gauge networks is relatively thin as the altitude increases. Furthermore, it will be possible to construct an efficient rain gauge network if the characteristics of different altitudes are considered when a new rain gauge network is newly constructed.

Deposition Characteristics of Water-soluble Inorganic Ions in the Iksan Ambient Air during Fall, 2004 (가을철 대기환경 중 수용성 이온성분의 침적특성)

  • Kang, Gong-Unn;Kim, Nam-Song;Jeon, Seon-Bok
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.359-372
    • /
    • 2006
  • In order to investigate the daily deposition characteristics of water-soluble inorganic components in airborne deposit on the Iksan, deposition samples were collected using a deposition gauge from October 16 to November 1, 2004. Deposition samples were collected using two different sampling gauges, a dry gauge and a wet gauge, respectively. To get wet the bottom of wet gauge during the sampling period, the volume of $30{\sim}50ml$ distilled ionized water was added in a wet gauge before the beginning of each deposition sampling. Deposition samples were collected twice a day and analyzed for inorganic water-soluble anions ($Cl^-,\;{NO_3}^-,\;{SO_4}^{2-}$) and cations (${NH_4}^+,\;Na^+,\;K^+,\;Mg^{2+},\;Ca^{2+}$) using ion chromatography. Qualify control and quality assurance of analytical data were checked by the data obtained from reinjection of standard solution, Dionex cross check standard solutions, and random several deposition samples, and measured data was estimated to be reliable. Considering the deposition sample volume, the sampling time, the surface area of sampling container, and the ion concentration measured, the daily deposition amounts for measured ions were calculated in $mg/m^2$. The total daily deposition amounts of all measured ions for dry and wet gauge were $7.5{\pm}2.8$ and $17.7{\pm}4.2mg/m^2$, respectively. A significant increase in deposition amount during rainfall days was observed for both wet gauge and dry gauge, having no difference of deposition amount between in wet gauge and in dry gauge. The mean deposition of all ions measured in this study were higher in wet gauge than in dry gauge because of the surface difference of the sampling container, especially for ${NH_4}^+\;and\;{SO_4}^{2-}$. The mean deposition amounts of ${NH_4}^+\;and\;{SO_4}^{2-}$ in wet gauge were found to be about 10 times and 3 times higher than those in dry gauge, while the rest of the chemical species were equal or a little higher in wet gauge than in dry gauge. Dominant species in dry gauge were ${NO_3}^-\;and\;Ca^{2+}$, accounting for 21% and 28% of the total ion deposition, whereas those in wet gauge were ${SO_4}^{2-}\;and\;{NH_4}^+$, accounting for 19% and 41% of the total ion deposition, respectively.

A Study on the Gauge Types Comparative Analysis of Basic Jacquard Structure (기본 자카드 조직의 게이지 변화에 따른 특성에 관한 연구)

  • Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.19 no.4
    • /
    • pp.1-15
    • /
    • 2017
  • The aim of this study is to plan a design that satisfies consumer needs by forecasting future properties following changes of gauge in basic Jacquard structure and to provide helpful data for a variety of knit-wear development. Four basic Jacquard knit samples (Normal Jacquard, Bird's eye Jacquard, Floating Jacquard, Tubular Jacquard) were selected and projected by using three types of gauges (7G, 12G, 14G) with an SES-122S type Computer Knitting machine of Shimaseiki MFG. Twelve different types of samples with Jacquards and gauges were tested on a flat table by measuring the course and wale in a 1cm area to calculate the gauge of samples. The mechanical properties of 12 types of Jacquard samples were measured using KES-FB (Kawabata Evaluation System for Fabric, Kata Tech Co. Ltd). As the result of comparing the number of patterns, courses and wales depending on the change of gauge of the basic Jacquard structure, it was observed that the number of patterns per specific length, course and wale has increased from 7G to 14G, a high-gauge. According to objective research regarding Jacquard structure, 7G Tubular Jacquard, which is low gauge, seems to be suitable for masculine design as it is heavy and thick, and has rigid and rough texture due to a high level of flexural strength and shear property. 14G Floating Jacquard, which is high gauge, seems to be suitable for feminine, silhouette design as it is light, thin, soft, flexible and has high drape. The result of this study provides a theoretical foundation for knit-wear development considering basic Jacquard structure and gauge-specific properties. This study can be used to provided directions for the development of knit industry.

  • PDF

Mass Transfer of Gas-Liquid in Agitated Vessel Using Wire Gauge Impeller (금망임펠러를 이용한 교반조에서의 기-액 물질이동)

  • Lee, Young-Sei
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • The gas-liquid mass transfer volumetric coefficients in gas-liquid agitated vessels with wire gauge impellers were measured to be compared with those in vessels with disk turbine and paddle impellers. Also mass transfer volumetric coefficients for disk turbine, paddle impeller and wire gauge impeller in cylindrical agitated vessel was measured over a wide range of Reynolds number from turbulent flow to transition regions. The effect of geometries on $k_La$ is clarified experimentally. Mass transfer volumetric coefficients $k_La$ depends only on the power consumption ($P_{gv}+P_{av}$) per unit volume.

  • PDF

Development of High-Temperature Heat Flux Gauge for Steel Quenching (강재 급속냉각용 고온 열유속게이지 개발)

  • Lee, Jungho
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.6
    • /
    • pp.323-330
    • /
    • 2010
  • The present study was motivated by increasing demands on quantitative measurements of the heat flux through the water cooling and quenching process of hot steel. The local heat flux measurements are employed by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are directly used to measure the heat flux variation during water cooling and quenching of hot steel. The heat flux can be directly achieved by Fourier's law and is also compared with numerical estimation which is solved by inverse heat conduction problem (IHCP). The high-temperature heat flux gauge developed in this study can be applicable to measure cooling rate and history during the actual cooling applications of steelmaking process. In addition, the measurement uncertainty of heat flux is calculated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard.

Earthquake Movement Measurement of the Top of Bridge Pier Using Fiber Optic Smart Structure Concept (광섬유 스마트 구조물의 개념을 이용한 교량상부 내진거동 측정)

  • Kim Ki-Soo;Han In-Dong
    • Composites Research
    • /
    • v.19 no.3
    • /
    • pp.43-49
    • /
    • 2006
  • In this paper, a long gauge Fiber Bragg Grating (FBG) sensor system is described and long gauge FBGs are well-suited for measuring the upper parts of the bridge piers under the extremely severe movement conditions. In the experiments, we used more than 30m long FBG sensors to measure the movement of top part of the bridge piers which are separated from the main bridge by cutting the decks. With the actuator, the deck and girders were pushed and released. We checked the movement of the top of the pier while releasing the pressure of the actuator with the long gauge fiber sensor. In order to measure the movement of the upper part of the pier, the reference point must be outside of the pier. Using the optical fiber sensors, one end of the sensor is attached to the top of the pier and the other end is attached to the bottom of the next pier. The fiber sensors showed good response to the release loading and we could calculate the movement of the top part of the pear.

Comparison and analysis between TOPEX/POSEIDON Altimeter data and In-Situ Tide Gauge Data in the Eastern Asian Marginal Seas (동아시아 주변해역에서의 TOPEX/POSEIDON 위성 고도자료와 Tide Gauge 현장자료 간의 비교 및 해석 연구)

  • 윤홍주
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.606-609
    • /
    • 2000
  • These results indicate that the low-Sequency signal of T/P data (with periods greater than 200 days) can be interpreted most safely. Similarly to the case of the T/P data, corrections were also applied to those of tide gauge counterparts. Hence, when the 200-day effect was filtered out, the agreement between T/P and TG data sets was optimized.

  • PDF

MACHINE TOOL TECHNOLOGY;THE PRESENT AND THE FUTURE(8) (공작기계 기술의 현재와 미래(8))

  • 강철희
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.11
    • /
    • pp.5-19
    • /
    • 1995
  • 항공기 기술의 발전은 다양한 과학기술 분야의 발달에 끊임없이 큰 영향을 주어왔고, 또 기기서 파생된 신 기술도 수없이 발생하였다. NC 공작기계도 그 하나이다. 제 2차 세계대전 후 미공군은 복잡한 형상의 항공기 부품가공과 고정밀도의 검사용 Gauge를 제작할 필요성을 얻게 되었다. Helicopter의 Rotor blade의 Prifile 검사용 Plate gauge를 가공할 수 있는 기계를 개발 중에 있었던 J.T.Person이 Jig boring machine을 저자적으로 제어하면서 Gauge를 가공하는 방법을 1947년 미공군에 제안하게 되었다. 이것이 NC 발달사에 기록된 역사적인 사실이며 이 Project는 후에 MIT로 넘아가고 1952년에 NC milling machine을 완성시켰다. 그 후, 1955년 Gidding & Lewis사가 최초로 NC 공작기계를 공업화한 제1호기 Numericord를 시장에 내 놓게 되었다.

  • PDF

Performance tests and uncertainty analysis of tipping bucket rain gauge (전도형 강수량계의 성능시험 및 불확도 분석)

  • Hong, Sung-taek;Park, Byung-don;Shin, Gang-wook;Jung, Hoe-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.595-597
    • /
    • 2018
  • Precipitation has a wide range of applications, such as the management and operation of dams and rivers, supply of dranking water for urban and industrial complex, farming and fishing, forest greening, and safety management. In order to prepare for disasters and to obtain economical effects in case of flood damage, it is necessary to measure accurate precipitation. In this study, we carried out the characteristics tests for various types of rainfall gauge using integrated verification system, which can analyze the performance of collective type rainfall gauge. The uncertainty for tipping bucket rain gauge was 0.2887 mm. Therefore, it can be seen that the uncertainty is calculated differently depending on the characteristics of the rainfall gauges. The uncertainty is also influenced greatly by the resolution.

  • PDF