• 제목/요약/키워드: 170[kV] GIS

검색결과 34건 처리시간 0.03초

GIS 단로기의 부분방전 신호해석 (The signal interpretion of PD on DS for GIS)

  • 김종서;박용필;이은석;정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 제6회 학술대회 논문집 일렉트렛트 및 응용기술연구회
    • /
    • pp.1-4
    • /
    • 2004
  • Recently, because GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this anslysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected singals with the application of neural network algorithm.

  • PDF

부분방전 검출을 이용한 GIS 단로기 내부이상 진단 (The diagnosis of internal trouble on DS for GIS using PD detection)

  • 김종서;이은석;천종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.575-578
    • /
    • 2003
  • Recently, because GIS equipment has problems on confidence according to long-time usage, development of diagnosis technique has been importantly recognized. Therefore. measurement and analysis of PD has been generally used much equipment of GIS. But, in case of measurement of PD at field, real trouble signals are difficult to classify noise. Accordingly, a variety of trouble conditions for DS were simulated, and detected signals were analyzed by the application of electrical and mechanical methods. For this analysis, detected signals were accumulated according to phase-magnitude with the application of Induction sensor, and then we analyzed the characteristics. For the simulation experiment, we made DS for 170kV GIS and analyzed the characteristics of detected singals with the application of neural network algorithm.

  • PDF

송전선로 유도전압으로 진공중인 170kV GIS의 절연파괴 사례분석 (Analysis of Breakdown of 170kV GIS in a vacuum due to transmission line inducted voltage)

  • 김진환;서정철;박한우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.54-56
    • /
    • 2008
  • 전력계통에서 사용하는 고전압급의 차단기의 절연은 대부분이 SF6 GAS를 사용하고 있으며 (22.9kV급에서는 진공차단기가 주종을 이룸) 운전중 압력은 약 $3.6-6.0kg/cm^2$이다. 내부점검을 위해서는 무압상태에서 Gas를 회수장치에 옮겨 보관후 작업을 수행한다. 그러나 다시 Gas를 용기(容器)내로 담아 넣기 위해서는 진공(眞空)하여야 하는 공정이 필요하며,. 이 과정의 진공은 진공초기 단계정도로 절연내력을 가지는 진공상태라 할 수 없다. 진공작업과정에 발생한 고장사례를 통해 전기절연 상애의 선행 조건이 어떠해야 하는지 살펴보고자 한다.

  • PDF

170 kV GIS용 Composite Hollow Insulator 특성 평가 (Characteristices of Composite Hollow Insulator for 170 kV GIS)

  • 장윤기;정용수;이동원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1534-1535
    • /
    • 2011
  • Composite hollow insulator consist of an insulating tube bearing the mechanical load protected by an elastomer housing the loads being transmitted to the tube by metal fittings. The core processes are comprised briefly and the electrical and mechanical performance were examined according to the IEC standards. In this study, we have manufactured the composite hollow insulator, and carry out the insulator and busing type test according to the IEC standards. Comprehensive approach followed by the test results would give feasible hollow composite insulator compliable to the IEC standards.

  • PDF

An Application of the Novel Techniques Detecting Partial Discharge Employable to GIS Using Optical Sensor

  • Ryu, Cheol-Hwi;Jung, Seung-Yong;Koo, Ja-Yoon;Yeon, Man-Seung
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.396-400
    • /
    • 2007
  • A novel technique has been proposed and related experimental works have been performed in order to detect the partial discharges and the location of the possible defects introduced into the Gas Insulated Switchgear. For this purpose, a prototype HY Pockels sensor has been developed and then employed in order to investigate its field applicability for finding the location of the defects using a 170kV GIS mock-up. Our proposed sensor enables us to measure the electric field variation due to the PD occurrence. In addition, the different PD patterns are observed, which might be dependant on the location and the distance of the sensor with respect to the PD source. Throughout this work, its linear response has been proved to be admissible as a function of the applied voltage. And also the position of the PD source might be distinguished by comparing the PD patterns.

신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석 (The Analysis of trouble signal on DS for GIS using Neural Network)

  • 김종서;박용필;천종철;이은석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1196-1199
    • /
    • 2003
  • Recently, the development of diagnosis technique with high confidence is important on power equipment, for this reason is use for measurement and analysis of PD with prior appearance of insulation breakdown. In this paper, we presents the analysis of trouble signal to use ${\phi}-Q$ method which display 2D and 3D Equipment of simulation has made independently DS for 170kV GIS of one phase with same on field. The detected signal through the sensor of Induction and Acoustic Emission is classified to use characteristic neural network algorithm and then it is analysis.

  • PDF

가스절연기기(GIS)의 인위적 결함에 의한 부분방전의 검출을 위한 Probe-Type Pockels Sensor의 적용 가능성 (A possible application of the partial discharge measurement due to artificial defect using Pockets sensor in GIS(Gas Insulated Switchgear))

  • 류철휘;이재호;마지훈;강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1770-1772
    • /
    • 2003
  • 본 연구는 국내에서 최초로 제안되고 적용가능성이 입증되어 설계, 제작된 Probe-type Pockets sensor(HY-Pockets Sensor)를 GIS등의 고전압 장비들에 응용한 레이저 부분방전 진단 시스템 개발을 목표로 하고 있다. 이러한 목적으로, 170kV 급 실 규모 GIS내부의 전류 도체에 다양한 곡률 반경의 침 전극을 부착시켜 부분 방전에 기인된 불평등 전계를 형성시켜 개발된 센서의 실규모 적용 가능성을 고찰하였다. 본 레이저 계측 시스템은 He-Ne laser, single multi-mode optical fiber, $2{\times}2$ 50/50 laser to single mode fiber coupler, probe-type Pockets sensor, photo detector 등으로 구성하여 레이저의 진행을 유도하고, 신호의 특성을 분석하였다. probe-type Pockets sensor로부터 의 출력 신호는 photo detector를 통해 전기적 신호로 변환되어 digital oscilloscope에 의해 측정되고, 또한 PC를 통해 데이터의 저장과 통계적, 분석적 처리 과정을 수행하게 된다. 본 연구의 결과로서 부분방전원에서 생성된 방전 신호에 대한 거리에 따른 센서 감도 결정, 그에 대한 센서 감도의 보정 향상, 전계의 세기의 변화에 따른 센서의 선형성 등이 도출되었고, 이러한 실험결과를 통해 실 GIS(170kv급) 내부에서 발생하는 부분방전의 검출에 본 레이저 부분방전 진단 시스템의 적용 가능성이 제시 되었다.

  • PDF

부분방전 검출을 이용한 GIS용 단로기의 이상신호 분석 (The Analysis of trouble signal on DS for GIS using detection of PD)

  • 김종서;이은석;천종철;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 학술대회 논문집 일렉트렛트 및 응용기술연구회
    • /
    • pp.29-32
    • /
    • 2003
  • Recently, the development of diagnosis technique with high confidence is important on power equipment, for this reason is to use for measurement and analysis of PD with prior appearance of insulation breakdown In this paper, we presents the analysis of trouble signal to use both method of general analysis of $\Phi$-Q-N in PD and statistical parameter by this interpretation Equipment of simulation has made independently DS for 170kV GIS of one phase with same on field. The detected signal through the sensor of Induction and Acoustic Emission is classified which used to characteristic neural network algorithm and then it is analysis.

  • PDF

GIS용 외장형 광대역 극초단파 부분방전 센서의 구조에 따른 특성 비교 (Comparison of the characteristics related to the structure of external-type UHF UWB PD sensors for GIS)

  • 황철민;구자윤;박기준;구선근;윤진열;이영상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1769-1771
    • /
    • 2004
  • 가스절연 개폐장치(GIS)용 극초단파 부분 방전 측정장치에 다양하게 사용 할 수 있는 외장형 부분 방전 (PD) 센서를 제작하였다. Fat-dipole, 대수주기(log-periodic), spiral 및 log-spiral 형 패치안테나를 이용한 외장형 PD 센서의 주파수 특성과 검출감도를 기본 Dipole형 센서와 비교하였다. 제작된 센서는 170kV 단상 GIS의 스페이서에 장착하여 5 pC PD에 대한 각 센서의 주파수 특성과 감도를 측정 하였다.

  • PDF

광섬유를 이용한 170 kV GIS용 전류 측정 장치의 개발 (Development of optical current transformer used an optical fiber for 170 kV GIS)

  • 정재용;김덕래;김병태;박정남;김영근;서정민;함길호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1978-1980
    • /
    • 2003
  • 본 논문에서는 광을 이용한 전류 측정 장치의 연구 내용에 대하여 기술하였다. 광을 이용한 전류 측정 장치의 가장 큰 문제점은 감도 저하를 주는 선형 복굴절 양이며, 이러한 선형 복굴절을 줄이는 방법은 광섬유를 비틀어서 선형 복굴절 양에 비해 원형 복굴절의 양을 크게 해주는 방법을 사용하였다. 광섬유를 비틀어서 측정한 결과는 측정 감도가 약 3배의 증가를 보였으며, 측정오차의 경우도 1 % 이내의 선형성을 나타내었다. 본 실험의 결과로 광섬유를 비트는 방법이 광을 이용한 전류 측정 장치의 선형 복굴절을 크게 감소시킴을 알 수 있었으며, 대전류 측정에 측정도를 높일 수 있다고 판단된다.

  • PDF