• Title/Summary/Keyword: 165cm

검색결과 296건 처리시간 0.026초

165cm 이상 키 큰 여성의 체형 유형 (Body Types of Tall Women Over 165cm)

  • 차수정
    • 한국의류학회지
    • /
    • 제48권3호
    • /
    • pp.528-542
    • /
    • 2024
  • The aim of this study was to analyze and typify the body shape of tall women aged 20-69 using 3D measurement data from the 2020 8th Human Dimensions Survey data with greater than 165.0 cm in height defined as large stature. Each body type's characteristics were examined to derive points of differentiation compared to women of average body type. The analysis showed that as height increases, body height, length, and generally body circumference, thickness, and width also increase. However, taller women were found to have thinner waists, indicating a wider, flatter waist area. Waist circumference was also smaller, albeit not at a statistically significant level. Body shapes of adult women over 165.0 cm tall were classified into three types. The following body types were analyzed: thick ankles and drooping shoulders, thin and short torso, tall and long, long torso and thick ankles, large body circumference, thickness and width, normal torso length, and short stature and thin ankles. To develop garments for adult women over 165.0 cm tall, a new drafting method was required set the waist, knee height, and shoulder width.

투수성 콘크리트포장의 실용화를 위한 실험적 연구 (An Experimental Study of Permeable Concrete Pavement for Application)

  • 문한영;김성수;정호섭
    • 콘크리트학회지
    • /
    • 제10권3호
    • /
    • pp.165-173
    • /
    • 1998
  • 투수성 콘크리트포장은 우천시 도로포장 노면의 배수, 차량 주행 안전성의 향상 및 소음의 저감등을 목적으로 개발된 포장이지만 주행환경 및 도로주변과의 환경조화에도 기여한다. 일반적인 배수성 아스팔트 콘크리트포장에서는 투수계수 1$\times$10-2cm/sec를 목표로 정하고 있으나 본 연구에서는 투수성 콘크리트포장의 실용화를 위한 연구의 일환으로 투수계수1$\times$10-1cm/sec를 목표로 정하여 골재의 최대치수, 잔골재율 및 단위시멘트량을 변화시킨 투수성 콘크리트의 공극률, 연속공극률 및 투수계수와 제강도를 측정한 결과에 대하여 고찰하였다. 투수성 콘크리트의 목표투수계수 1$\times$10-1cm/sec 일 때 공극률 및 연속공극률은 각각 15 %와 12%정도이며, 압축강도는 240kg/$\textrm{cm}^2$정도의값을 나타내었으며, 골재의 최대치수가 10~13mm일 경우, 잔골재율 10~20%, 단위시멘트량 380 kg/$\textrm{cm}^2$정도가 적절한 배합으로 생각된다.

교목류 뿌리의 비탈면 안정효과 분석 - 뿌리의 인장강도를 중심으로 - (Analysis of Slope Stability Effect of Arbors' Roots - On Tensile Strength of the Roots -)

  • 오재헌;황진성;차두송
    • 한국환경생태학회지
    • /
    • 제25권1호
    • /
    • pp.31-36
    • /
    • 2011
  • 본 연구는 사면안정해석에 필요한 기초자료를 제공하고자 잣나무, 낙엽송, 소나무, 신갈나무, 오리나무를 대상으로 교목류 뿌리의 인장력 및 인장강도를 측정 분석하였다. 그 결과 인장력은 대부분 뿌리 직경의 거듭제곱의 형태로 증가하는 것으로 나타났다. 또한 뿌리의 평균 인장강도는 잣나무 $165.38kgf/cm^2$, 낙엽송 $172.78kgf/cm^2$, 소나무 $176.25kgf/cm^2$, 오리나무 $214.29kgf/cm^2$, 신갈나무 $224.19kgf/cm^2$로 나타났으며, 뿌리의 직경이 커질수록 인장강도가 감소하는 경향을 나타냈다. 측정 분석된 인장강도를 기초자료로 토양의 전단강도 증가값을 산출한 결과 잣나무 $0.099kgf/cm^2$, 낙엽송 $0.104kgf/cm^2$, 소나무 $0.106kgf/cm^2$, 오리나무 $0.129kgf/cm^2$, 신갈나무 $0.135kgf/cm^2$인 것으로 나타났다.

심폐소생술 제공자의 발판 높이와 자세가 기본심폐소생술의 정확도에 미치는 영향 (The Impact on the accuracy of the basic CPR according to position and foot-board height of the basic CPR provider)

  • 최은숙;조근자
    • 한국응급구조학회지
    • /
    • 제12권3호
    • /
    • pp.27-41
    • /
    • 2008
  • Purpose : The purpose of this study was to supply basic data for the impact on the accuracy of basic CPR according to position and foot-board height of basic CPR provider. Methods : Study design was within - group design. Subjects were 25 EMT-P Students in K city. Interventions was basic CPR performed on a resuscitation manikin placed on a hospital bed, kneeling on the bed adjacent to the manikin. Data was analyzed using descriptive statistics and Friedman test. Results : In case of the basic CPR performed on a resuscitation manikin placed on a hospital bed, ventilation accuracy was the highest in less than 160 cm height, foot-board height : $34.2{\pm}1.48cm$, 91.4% and in 161-165 cm height, foot-board height : $26.0{\pm}2.14cm$, 88.4% and in 171-175 cm height, foot-board height : $23.0{\pm}1.41cm$, 91.3% and in the above 176 cm, kneeling on the bed, 95%. Chest compression accuracy was the highest in less than 160 cm height, foot-board height : $30.2{\pm}1.48cm$, 95.6% and in 161-165 cm height, kneeling on the bed, 97.6% and in 171-175 cm height, kneeling on the bed, 98.5% and in the above 176 cm, kneeling on the bed, 98.7% and foot-board height : $20.5{\pm}1.91cm$, 98.7%. Chest compression error was due to too weak : 2.0-35.4 times. There were ststistically significant differences in 191-195 cm group according to chest compression mean depths($x^2=10.824$, p = .013) and chest compression error (p = .040). Conclusion : In contrast to current guidelines, the position and foot-board height of basic CPR provider are very important to the accuracy of the basic CPR. Furthermore, we recommend that a using real time audiovisual feedaback system significantly improve the quality of chest compression and ventilation during resuscitation.

  • PDF

유기용제의 피부흡수 연구 (Study on the Skin Absorption of the Organic Solvents)

  • 김현영;정용현;정재황;서길수;문영한
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.279-288
    • /
    • 1997
  • The penetrating speeds of organic solvents into the nude mouse skin were measured by in vitro methods(diffusion cell methods) and in vivo methods(measuring internal residues of the organic solvents). The results were as follows: 1. The penetrating speeds of toluene, m-xylene, MEK, MIBK, ethanol, IPA and 2-bromopropane into the skin were $0.4832mg/cm^2/h$, $0.1738mg/cm^2/h$, $1.124mg/cm^2/h$, $0.6627mg/cm^2/h$, $1.747mg/cm^2/h$, $1.359mg/cm^2/h$, and 2-bromopropane $4.165mg/cm^2/h$ respectively. 2. The penetrating speeds of the mixtures of two, toluene and m-xylene, the mixture of three, IPA, ethyl acetate, and MIBK, the mixture of five, toluene, m-xylene, IPA, ethyl acetate, and MIBK were $0.172mg/cm^2/h$, $1.431mg/cm^2/h$, and $2.983mg/cm^2/h$ respectively. 3. The absorption speeds of 2-bromopropane and styrene which were measured by in vivo processes were $3.12mg/cm^2/h$ and $1.44mg/cm^2/h$ respectively. The absorption speed of 2-bromopropane mesured in vivo was 74.9% of that measured by in vitro methods, $4.165mg/cm^2/h$.

  • PDF

이성분계 고분자 블렌드의 형태학에 미치는 사출 조건의 영향 (Effect of injection molding conditions on morphology of binary polymer blends)

  • 손영곤
    • 한국산학기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.165-169
    • /
    • 2008
  • 사출 조건이 이성분계 고분자 블렌드의 형태학에 미치는 영향을 관찰하기 위해 폴리페닐렌옥사이드 (PPO)/폴리아마이드 6 (PA 6) 블렌드를 선정하였다. 두께가 3.2 mm이고 한 변의 길이가 15 cm인 정사각형의 평판 형태의 사출물을 여러 사출 조건에서 제조하고 각 위치별로 파단시편을 제조하여 형태학을 관찰하였다. 그 결과 수지가 스크류, 노즐 스프루 게이트를 지나 최종위치에 자리 잡을 때까지 복잡한 온도, 전단력과 신장력의 영향으로 복잡한 형태학을 가짐을 알 수 있었다.

한방성장촉진제(韓方成長促進劑)에 관(關)한 임상보고서(臨床報告書) (Report of Oriental Medicine growth factor)

  • 박승만
    • 대한한방소아과학회지
    • /
    • 제15권1호
    • /
    • pp.195-202
    • /
    • 2001
  • 1. Purpose : Clinically I have studied efficacy of herb treatment and development of herb growth palpation about handicapped children for growth. 2. Methods : 165 patients who visited hospital from January, 2000 to January 2001 3. Results : Average growth of children who visited hospital was less than 4cm but boys have grown 9.8cm/year and girls grown 7.8cm/year at average after treatment by herb. 4. Conclusion : In case of decreasing growth to have get less growth hormone, it has confirmed positive effectiveness by herb treatment even if it is normal.

  • PDF

중국(中國) 성인여성용(成人女性用) 의류치수규격(衣類値數規格) 설정(設定) 연구(硏究) (제1보)(第1報) - 전체집단(全體集團)을 대상(對象)으로 - (A Study on Development of Apparel Sizing System for Chinese Adult Female I - focused on the entire group -)

  • 위혜정;손희순
    • 패션비즈니스
    • /
    • 제10권5호
    • /
    • pp.135-158
    • /
    • 2006
  • The purpose of this study was to provide for the useful fundamental data by developing an appearl sizing system according to body types for Chinese Adult Female. Thus, it was to improve of fittness and coverage rate of exporting domestic clothing to China. For study, It was measured 1360 female women aged between 19 and 50 who resident in Beijing and Shanghai in China. as a sample, 1381 female women was seleted for development of apparel sizing system. Thus, this study was to characterize body types of Chinese adult female by classifying them into groups and set coverage rate of ready-made clothes by developing an apparel sizing system according to the Women's Wear Specifications(GB/T 1335.2-1997), National Standards of People's Republic of China. As for the method of this study was done during Jun. 23 $\sim$ Aug. 7, 2004. Data analysis were processed by SPSS WIN 10.0 Program was used to for technical statistical analysis. The result was as follows: The clothes dimension for upper and lower body and the coverage rate of body size that had the highest appearance ratio from the entire group was Y-type 160-84$\cdot$160-64(4.6%) and the section 160cm 32.4%, A-type 160-88$\cdot$160-72(3.3%) and the section 160cm 28.1%, B-type 155-88$\cdot$155-78(3.8%) and the section 155cm 27.8%, C-type 150-96$\cdot$150-88(2.5%). The result By setting of representative size number and production coverage rate for Chinese adult female. The representative size number of the entire group was set for 150-80A$\cdot$150-64A(1.0%), 155-84A$\cdot$155-68A(2.6%), 160-88A$\cdot$160-72A(3.3%), 165-84A$\cdot$165-68A (2.8%), 170-96A$\cdot$170-80A(0%). The production coverage rate for each representative size number was SS size the section 150cm 2.8%, size the section 155cm 17.0%, M size the section 160cm 31.6%, L size the section 165cm 25.0%, XL size the section 170cm 12.6% that covered 85.0%.

중국 성인여성용 의류치수규격 설정 연구 (제II보) - 20대 연령집단을 중심으로 -

  • 위혜정;손희순
    • 패션비즈니스
    • /
    • 제12권4호
    • /
    • pp.56-72
    • /
    • 2008
  • The purpose of this study was to provide with the useful fundamental data by developing the appearl sizing system according to body types for the Women's Wear Specifications(GB/T 1335.2-1997), National Standards of People's Republic of China. Thus, it was to improve of the garment fit and coverage rate for the apparel production assortment and stock of exporting domestic clothing to China. For this study, 581 female women aged in their twenties who lived in Beijing and Shanghai were selected for the development of the apparel sizing system who resident in Beijing and Shanghai in China. As for the method of this study was made three primary items(length, bust girth, waist girth) and seven secondary items. Data analysis were processed by SPSS WIN 10.0 Program was used. The research selected 3 major body measurements, such as stature, bust girth, waist girth and 7 secondary measurements to investigate the body features of the Chinese adult women. The data throughout the study were analyzed by using SPSS WIN version 10.0 S/W. The result were as follows: The clothes dimensions for upper and lower body and the coverage rate of body size that had the highest appearance ratio from the selected age group in 20's were: Y-type 160-84 155-64(5.9%) and the section 160cm 22.6%, A-type 160-80 160-62(39%) and the section 160cm 27.9%, B-type 155-80 155-66(6.2%) and the section 160cm 24.7%. The representative size codes of the Chinese adult women aged in their 20's were set for representing certain body dimensions such as 150-76A 150-60A(0.0%), 155-80A 155-64A(2.4%), 160-84A 160-68A(3.9%), 165-88A 165-72A(0.3%), 170-92A 170-76A(0.0%). The production coverage rates for the each representative size codes were S size the section 150cm 1.5%, M size the section 155cm 15.3%, L size the section 160cm 36.0%, XL size the section 165cm 29.7%, XXL size the section 170cm 11.4% that covered 93.9%.

류마티스 관절염 치료용 디스프로슘-165금속 응집입자($^{165}Dy-MA$)의 제조에 관한 연구 (Studies on Preparation of Dysprosium-165 Metallic Macroaggregates for the Treatment of Rheumatoid Arthritis)

  • 박경배;김재록
    • 대한핵의학회지
    • /
    • 제28권2호
    • /
    • pp.227-233
    • /
    • 1994
  • Irradiation of 20mg of natural $Dy(NO_3)_3$ in a neutron flux of $2{\times}10^{13}n/cm^2$ sec for 4 hours gave 5.76 Ci of $^{165}Dy$(specific activity, 610mCi/mg Dy) with high radionuclidic purity (>99.9 %). $^{165}Dy-MA$ was prepared in a quantitative yield by reacting the aqueous solution of $^{165}Dy(NO_3)_3$ with sodium borohydride solution in 0.2N NaOH. Coulter particle analyzer exhibited mean particle size of $2.6{\mu}m$ (range $1{\sim}6{\mu}m$), Even though the $^{165}Dy-MA$ suspension in saline was stored at $37^{\circ}C$ for 24 hours or autoclaved at $121^{\circ}C$ for 30minutes, there was no significant change in particle size and leakage problem indicating the prepared $^{165}Dy-MA$ is sufficiently stable. In-vivo retention studies were carried out by administering $^{165}Dy-MA$ into the knee joint space of normal rabbits. Gamma camera analysis showed high retention in joint space of normal rabbits. Gamma camera analysis showed high retention in joint space even at 24 hours after administration (> 99.9%). The ease with which the $^{165}Dy-MA$ can be made in the narrow size range and their high invitro and vivo stability make them attractive agents for radiation synovectomy.

  • PDF