Development of 765kV Shell Type Transformers for Generator Step-up (발전소용 외철형 765kV 변압기 개발)

  • Kim Yungmin;Kim Dogyoon;Joe Gwangje;Bae Yongbae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.515-519
    • /
    • 2005
  • We have developed shell type 765kV transformers for generator step-up. Our research and development for shell type 765kV transformers have been continued since 1990. The shell type 765kV transformers of single phase 3MVA for step-up and 500MVA for power transmission were developed in Dec. 1992 and Oct. 1996, respectively. 204MVA 765kV transformer for generator step-up was also developed with the basis of technique and experience to the present. Total 12 phases of 204MVA 765kV transformers will be delivered at Tangjin thermal power plant by 2006. This paper describes electrical and structural features of the shell type 204MVA 765kV transformer.

Effect of "Green-one" organic nutrient on mycelial growth and fruiting of Pleurotus ostreatus (유기농 자재 『그린원』이 느타리버섯(Pleurotus ostreatus)의 균사생장 및 자실체 생육에 미치는 영향)

  • Chang, H.Y.;Kim, S.J.;Kim, J.K.;Kim, J.H.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.12 no.1
    • /
    • pp.21-27
    • /
    • 2010
  • The objective of this study was to determine the effects of "Green-one" organic nutrient on mycelial growth and fruiting of P. ostreatus. The dilution concentrations of "Green-one" was treated as follows. There was control, 100, 200, 400 concentrations. That treatments were treated with step of each mycelial growth step. The best of growth steps was mycelial scratching step. At that time, DPI(Day required for primordial formation after inoculation) was shortened for 1 day. Valid germination stipe are 15 pieces, 3 pieces more than control. Stipe length and stipe diameter was long each 4mm, 3mm more than control. Pileus size is shortened than control. Yields per one bottle(g/850cc) was 146g increased 6.5% than control 137g/850cc.

High Step-up DC-DC Converter by Switched Inductor and Voltage Multiplier Cell for Automotive Applications

  • Divya Navamani., J;Vijayakumar., K;Jegatheesan., R;Lavanya., A
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.189-197
    • /
    • 2017
  • This paper elaborates two novel proposed topologies (type-I and type-II) of the high step-up DC-DC converter using switched inductor and voltage multiplier cell. The advantages of these proposed topologies are the less voltage stress on semiconductor devices, low device count, high power conversion efficiency, high switch utilization factor and high diode utilization factor. We analyze the Type-II topologies operating principle and mathematical analysis in detail in continuous conduction mode. High-intensity discharge lamp for the automotive application can use the derived topologies. The proposed converters give better performance when compared to the existing types. Also, it is found that the proposed type-II converter has relatively higher voltage gain compared to the type-I converter. A 40 W, 12 V input voltage and 72 V output voltage has developed for the type-II converter and the performances are validated.

Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter (단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선)

  • 최세완;양승욱
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.21-26
    • /
    • 2001
  • This paper proposes a new double-connected 3-phase voltage source inverter with improved output voltage waveform. An auxiliary single-phase inverter injects a ripple voltage into the double-connected inverter to converter 12-step operation to 36-step operation. The KVA rating of the output phase-shifting transformer is reduced by employing a harmonic canceling reactor. The whole rectifier-inverter system including the proposed technique is introduced, and the experimental results are provided.

  • PDF

Design of Prototype Rotary-Lineat Step Motor by the Finite Element Method (유한 요소법에 의한 2자유도 스텝모터의 설계)

  • 정태경;한송엽;원종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.12
    • /
    • pp.567-572
    • /
    • 1986
  • In this paper, a new type of step motor with two degree of mechanical freedom, which is named rotary-Linear Step Motor(RLSM), is presented. Its rotor axis can perform linear and rotary motions either separately or simultaneously. This paper discribes the design of RLSM using finite element method in which the magnetic saturation effect of the iron core is taken into account. The design parameters such as torques, forces and inductances are obtained from the computed magnetic vector potentials. A new type of Rotary-Linear Step Motor was constructed. The calculated parameters agree well with measurements.

  • PDF

New Double-Connected Multi-Step Inverter for SVC (SVC를 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • 최세완;양승욱;김기용
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.460-463
    • /
    • 1999
  • A new multi-step voltage source inverter is proposed in this paper. The proposed scheme is composed of the double-connected 12-step inverter with an auxiliary circuit. The auxiliary circuit includes two voltage dividing capacitors, two switching devices and a low KVA autotransformer. The resultant system is shown to be a 24-step inverter suitable for large scale SVC applications in which the PWM method can not be employed. The design parameters are derived from the analysis of voltages and currents by means of switching functions. The simulation results verify the proposed concept.

  • PDF

Effects of Step-up Training on Walking Ability of Stroke Patients by Different Support Surface Characteristics

  • Oh, Geun-Sik;Choi, Yu-Ran;Bang, Dae-Hyouk;Cha, Yong-Jun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • PURPOSE: Gait disturbances in patients with hemiplegic stroke involve asymmetry of stance time. Step box training is used to supplement the limitations of stair walking training and increasing the torque value of the paralyzed lower leg's strength. This study aimed to investigate whether step-up training on unstable support could change walking ability in patients with chronic stroke. METHODS: Thirty stroke patients were randomly assigned to the step-up training group (experimental group), that performed training on an unstable surface, and the control group, that performed training on a stable surface. Walking speed, step length, and cadence were measured before and after training. Paired t-tests were used to compare pre- and post-intervention data, while the independent samples t-test was used to determine intergroup differences. Values of p < .05 were considered statistically significant. RESULTS: There was a significant difference in walking ability before versus after the intervention in both groups, although the experimental group showed greater differences than the control group (walking velocity by 8.1%; step length of the non-paralyzed side by 6.9%, respectively; p<.05). CONCLUSION: Step-up training might be more effective on an unstable surface than on a stable surface for increasing walking speed and step length of the non-paralyzed side.

Long-term Effect of Robot-assisted Step Training on the Strength of the Lower Extremity and Gait Speed in a Chronic Stroke Patient: A Preliminary Study (장기간의 로봇 보조 스텝훈련이 만성 뇌졸중 환자의 하지 근력과 보행속도에 미치는 영향: 예비 연구)

  • Se-Jung, Oh;Yong-Jun, Cha;Jongseok, Hwang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.65-73
    • /
    • 2022
  • PURPOSE: The present research examined the effects of progressive robot-assisted step training on the strength of the lower extremity and gait speed of an individual with stroke through changes between the baseline and the intervention stage (1, 3, 6, 9, and 12 months). METHODS: A single-subject (A-B) design was performed for a chronic stroke patient aged 70 years old. The robot-assisted step training was conducted three times a week during 12 months (40 minutes/session), and the assessment was conducted a total of seven times between the baseline and the intervention (No. 1, 3, 6, 9, and 12 months) to determine the effect of the intervention. RESULTS: As a result of the intervention, the muscle strength at the lower extremity of the paralysis side increased by the greatest extent 12 months after the intervention compared to the baseline, and the gait speed via the 10-meter walk test was increased as well. CONCLUSION: Long-term robot-assisted step training might be an effective intervention for improving the strength of the paretic lower extremity muscles and gait speed in stroke patients with difficulty walking independently. Further studies with sufficient sample sizes and a randomized control group will be needed to evaluate the long-term effects of robotic stepping rehabilitation.

Transition of Turbulent Boundary Layer with a Step Change from Smooth to Rough Surface (표면 형상 변화에 따른 난류경계층 유동장 분석)

  • Lee, Jae Hwa
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.3
    • /
    • pp.15-20
    • /
    • 2014
  • Direct numerical simulation (DNS) dataset of a turbulent boundary layer (TBL) with a step change from smooth to rough surface is analyzed to examine spatially developing flow characteristics. The roughness elements are periodically arranged two-dimensional (2-D) spanwise rods with a streamwise pitch of ${\lambda}=8k$ ($=12{\theta}_{in}$), and the roughness height is $k=15{\theta}_{in}$, where ${\theta}_{in}$ is the inlet momentum thickness. The step change is introduced $80{\theta}_{in}$ downstream from the inlet. For the first time, full images from the DNS data with the step change from the smooth to rough walls is present to get some idea of the geometry of turbulent coherent structures over rough wall, especially focusing on their existence and partial dynamics over the rough wall. The results show predominance of hairpin vortices over the rough wall and their spanwise scale growth mechanism by merging.

Systems for Production of Calves from Hanwoo IVM/IVF/IVC Blastocyst. IV. Direct Transfer of Vitrified and One-Step Diluted Hanwoo Blastocysts

  • 김은영;박세필;김덕임;이문걸;이종우;이금실;박세영;박은미;윤지연
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.73-73
    • /
    • 2001
  • This study was to examine whether the vitrified, one-step diluted and direct transferred Hanwoo IVM/IVF/IVC blastocysts can be successfully survived in vivo and they were succeeded into the live birth. For vitrification, blastocysts were serially exposed in glycerol (G) or/and ethylene glycol (EG) mixtures [10% (v/v) G for 5 min, 10% G plus 20% EG (v/v) for 5 min, and 25% G plus 25% EG (v/v) for 30 sect] which is diluted in 10% FBS added D-PBS. Thawing of straw was carried out in air for 10 sec and then in water bath of $25^{\circ}C$ for 20 sec. One-step dilution within the straw was done in water bath of $25^{\circ}C$ for 1 min. Vitrified and one-step diluted embryos were directly transferred into 36 (natural or hormone induced synchronized) recipient cows in 6 areas of Kyungsang Buk-Do. Pregnancies were confirmed at first when recipient cows did not return to the subsequent estrus cycle, and later by manual palpation per rectum on day 45, 90 and then living calves were derived into parturition. Overall pregnancy was 33.3%(12/36), However, higher pregnancy was obtained when the recipients exhibited estrus one day earlier than the age of transferred embryos (53.3 vs 25.0-27.3%), irrespective of synchronization methods. Also, parous recipients became pregnant higher than nulliparous heifers, And, there were not different in pregnancy rates by the aspect of corpus luteum (CL) quality of recipients (good, 29.4; fair, 37.5; poor, 33.3%). One hundred eight of frozen-thawed Hanwoo blastocysts were directly transferred into 36 recipient cows. In 12 of pregnant cows, 3 cows were aborted and 9 cows were calved [single, 66.7% (6/9): twin, 33.3% (3/9)]. Total embryo implantation rate was 11.1% (12/108). However, 9 Hanwoo calves were lived. Therefore, these results demonstrate that direct transfer technique of vitrified and one-step diluted bovine blastocysts can be applied easily and effectively with the higher pregnancy rate on field trial without the equipment and embryological skills.

  • PDF