• Title/Summary/Keyword: 1-D Simulation

Search Result 3,654, Processing Time 0.037 seconds

Analysis of Integrated Navigation Performance for Sensor Selection of Unmanned Underwater Vehicle (UUV) (무인잠수정 센서 선정을 위한 복합항법 성능 분석)

  • Yoo, Tae-Suk;Kim, Moon Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.566-573
    • /
    • 2014
  • This paper presents the results of an integrated navigation performance analysis for selecting the sensor of an unmanned underwater vehicle (UUV) using Monte Carlo numerical simulation. An inertial measurement unit (IMU) and Doppler velocity log (DVL) are considered to build the integrated navigation system. The position error and price of the sensor are selected as performance indices to evaluate the volunteer integrated navigation systems. Monte-Carlo simulation is introduced to analyze the circular error probability (CEP) and its variance. Simulation results provide the proper sensor combination for integrated navigation in relation to the performance and price.

Comparison Between Simulation and Test Result of Sigma-Delta STAP (Sigma-Delta STAP의 시뮬레이션과 시험 결과 비교)

  • Kwon, Bojun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.457-463
    • /
    • 2018
  • This paper compares the results of ${\Sigma}{\Delta}-STAP$ applied to actual radar test data and simulation data. The radar received a target signal from a virtual target generator and the clutter signal from a signal generator in an anechoic chamber. The simulation data were generated from ideal baseband radar signal modeling using the same parameter as that for the test radar. The ${\Sigma}{\Delta}-STAP$ results of the test and simulation data are similar in terms of the target signal shape and noise level. The SINR(Signal-to-Interfrence-plus-Noise Ratio) loss also had similar aspects, but the simulation result shows 1~2 dB higher SINR loss than the test result. This result verified that the simulation data can be a reasonable alternative test data when the ${\Sigma}{\Delta}-STAP$ is applied.

Study on Co-Simulation Method of Dynamics and Guidance Algorithms for Strap-Down Image Tracker Using Unity3D (Unity3D를 이용한 스트랩 다운 영상 추적기의 동역학 및 유도 법칙 알고리즘의 상호-시뮬레이션 방법에 관한 연구)

  • Marin, Mikael;Kim, Taeho;Bang, Hyochoong;Cho, Hanjin;Cho, Youngki;Choi, Yonghoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.11
    • /
    • pp.911-920
    • /
    • 2018
  • In this study, we performed a study to track the angle between the guided weapon and the target by using the strap-down image seeker, and constructed a test bed that can simulate it visually. This paper describes a method to maintain high-performance feature distribution in the implementation of sparse feature tracking algorithm such as Lucas Kanade's optical flow algorithm for target tracking using image information. We have extended the feature tracking problem to the concept of feature management. To realize this, we constructed visual environment using Unity3D engine and developed image processing simulation using OpenCV. For the co-simulation, dynamic system modeling was performed with Matlab Simulink, the visual environment using Unity3D was constructed, and computer vision work using OpenCV was performed.

3-Port Circulator for X-Band Radar (X-Band 레이더를 위한 3-포트 서큘레이터)

  • Yoon, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.355-362
    • /
    • 2015
  • In this study, we have fabricated 9.385[GHz] circulator that is composed of WR112 waveguide and Ferrite for X-band radar. For designing Ferrite, B/R mode(Below Resonance mode) was used and calculated the condition of 120 degree rotation of the electric field in Ferrite and calculated internal DC magnetic field and external DC magnetic field. Also, dielectric materials of the same shape with Ferrite was filled between two Ferrite for improving the performance of the circulator, including impedance matching, bandwidth, quality factor, insertion loss. To obtain optimum shape of the Ferrite and dielectric material, we used CST MWS. Simulation result of the circulator is that 1.02 : 1 VSWR, -40dB isolation, 0.2dB insertion loss and measurement result is that 1.03 : 1, -38dB, 1.2dB at 9.385[GHz]. We can get good agreement at isolation and VSWR, but insertion loss was 1 dB great than simulation result.

Performance Analysis of OFDM M-ary QAM System with One Tap Equalizer in Rummler Fading Channel (룸머 페이딩 환경 하에서 단일 탭 등화기를 사용한 OFDM M-ary QAM 시스템의 성능 분석)

  • 심재옥;김언곤
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.2
    • /
    • pp.175-180
    • /
    • 2002
  • In this paper, the system performace with the convolution rode using a Viterbi decoding and the one tap LMS(Least Meam Square) equalizer applied to the OFDM(Orthogonal Frequency Division Multiplexing) system, is analyzed through computer simulation. DMRS(Digital Microwave Radio System)is modeled as Rummler fading channel. In Simulation result, we known that the coding system improved about 3.6dB~10.5dB when BER is 10 $^3$and b is 0.1~0.2 in case of 16QAM(Qurdrature Amplitude Modulation). Also, we known that was improved about 19.7dB when the b is 0.1 and was demanded about 10.5dB when the b is 0.2 in case of 64QAM. we known that the soft decision improved about 2~0.9dB when the b is 0.1~0.2 in case of 16QAM and about 3.3~7.8dB in case of 64QAM. In the equalizer system, efficiency improved from the case of that Eb/No is more than 13dB.

Heated temperature and Range of the Oxy-acetylene Cutting Reinforcing Bar by Simulation and Experiment (시뮬레이션과 실험에 의한 산소절단기 절단시 철근의 수열온도 분포)

  • Kim, Bong-Joo;Kim, Jae-Hun;Cho, Byoung-Hoo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.1-5
    • /
    • 2008
  • The object of this experimental and simulation study is to find out heated temperature and range from the Oxy-acetylene cutting point of reinforcing bars (D10, D13, D16, D19, D22, D25 for each cases of SD3O and SD40) in room temperature ($20{\sim}22^{\circ}C$). This cutting is under the condition that a skilled worker cut one bar per a time. The results are these. 1. The temperature of the point 1 of reinforcing bars cut with Oxy-acetylene cutter is over 700$^{\circ}C$ under 1000$^{\circ}C$, but the temperature of the point 2 of reinforcing bars cut with Oxy-acetylene cutter is under 200$^{\circ}C$ 2. The temperature of the point that is apart 2cm from Oxy-acetylene cutting point is not over 200$^{\circ}C$, so reinforcing bars has not transform to be brittle. The results of simulation for temperatures of the each point apart from Oxy-acetylene cutting point is similar to upper experimental results.

Analysis of the Metal Flow in H-Beam Rolling using Beam Blank (빔 블랑크를 이용한 H 형강 압연 거동 연구)

  • Kim, J.M.;Choi, W.N.;Park, C.S.;Kim, K.W.
    • Transactions of Materials Processing
    • /
    • v.22 no.7
    • /
    • pp.383-388
    • /
    • 2013
  • Metal flow of the beam blank during H-beam rolling was examined in order to correlate the rolling defects with the beam blank configuration. For this purpose, H-beam rolling was performed on the beam blank where stainless steel bolts were inserted as the marker at the web and flange. The positional variation of the marker was monitored at each rolling pass, and the result was compared with the 3D FEM simulation employing the point tracking function. The simulation results were reasonably agreed with the experimental within the error of 0.5~1mm on both web and flange of the H-beam. It is anticipated that the 3D FEM simulation employing the point tracking function provides the guidance information on analyzing the correlation between the rolling defects and the beam blank configuration in H-beam rolling.

Knit Design Using 3D Virtual Clothing Simulation Program of Knit CAD System (니트 CAD시스템의 3D 가상착의 프로그램을 활용한 니트디자인)

  • Lee, Seul-A;Lee, Yoon Mee;Lee, Younhee
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.1
    • /
    • pp.104-117
    • /
    • 2015
  • Recently, the fashion industry has been integrating with The IT industry in order to develop in various ways. This study looks into ways to utilize the 3D CAD system, which would reduce time and cost while producing samples, and strengthen the communication between the brand and its cooperators by deploying knit designs using Knit CAD system's 3D virtual clothing program. The research method was reference, Internet resources 3D fashion CAD system and 3D Knit CAD system. Based on the data, simulation of the complete design of 4 deployed knit designs was done by using 3D virtual clothing program of the Knit CAD system utilizing knit design elements. One of each design element among the virtual clothing designs was chosen to produce real clothing, and the experts did verification on the appearance assessment of 3D virtual clothing knit designs of the Knit CAD system. As a result, 3D virtual clothing knit design of the Knit CAD system proved itself as an efficient system in terms of time and cost.

A Study on the Development and Optimization Design of Isolator by Using the 3D Simulator (3D Simulator를 이용한 아이솔레이터 최적화 설계 및 개발에 관한 연구)

  • Jung Seung-Woo;Choi U-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.229-238
    • /
    • 2006
  • In this paper, developed study about isolator that after design and optimizes center strip to use 3-D simulator. We use the factor about the change and propose simple mode of the simulation. Design strip line that center frequency is 1.85 GHz by software that use 3-D finite element method(FEM) and confirmed variable. Developed isolator were shown that more than isolation 25 dB, reflection loss has the more than 25 dB and insertion loss does not 0.2 dB. We could confirm that compare with simulation and manufacture sample propertied agrees more than 90 %.

Segmentation and 3D Visualization of Medical Image : An Overview

  • Kang, Jiwoo;Kim, Doyoung;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • In this paper, an overview of segmentation and 3D visualization methods are presented. Commonly, the two kinds of methods are used to visualize organs and vessels into 3D from medical images such as CT(A) and MRI - Direct Volume Rendering (DVR) and Iso-surface Rendering (IR). DVR can be applied directly to a volume. It directly penetrates through the volume while it determines which voxels are visualizedbased on a transfer function. On the other hand, IR requires a series of processes such as segmentation, polygonization and visualization. To extract a region of interest (ROI) from the medical volume image via the segmentation, some regions of an object and a background are required, which are typically obtained from the user. To visualize the extracted regions, the boundary points of the regions should be polygonized. In other words, the boundary surface composed of polygons such as a triangle and a rectangle should be required to visualize the regions into 3D because illumination effects, which makes the object shaded and seen in 3D, cannot be applied directly to the points.