• Title/Summary/Keyword: 1-3 Piezoelectric Composite

Search Result 64, Processing Time 0.027 seconds

Piezoelectric Properties on the Thickness of Specimens with PZT/Epoxy Composite Materials of 1-3 Connectivity (PZT/Epoxy (1-3형) 복합재료의 두께변화에 따른 압전특성)

  • 김용혁;김호기;김진수;이덕출
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.1
    • /
    • pp.7-14
    • /
    • 1988
  • In this paper, piezoelectric composite materials of 1-3 connectivity were prepared by using "dicing-filling" technique with PZT ceramics and epoxy polymers, and the dependence of piezoelectric properties on the thickness of specimens was investigated. In case that the PZT volume percent is 18.1%, according to an increment of thickness, the dielectric constant of composites( 33) is unchangeable, which is about 200, the piezoelectric coefficient (d33) is somewhat increased, which is about 240-280 (PC/N) and the electromechanical coupling factor of thickness mode(kt) is proportioned, but radial mode(kp) is constant.

  • PDF

3-D Underwater Object Restoration Using Ultrasonic Transducer Fabricated with 1-3 Type Piezoceramic/Polymer Composite and Neural Networks (1-3형 복합압전체로 제작한 초음파 트랜스듀서와 신경회로망을 이용한 3차원 수중 물체복원)

  • Jo, Hyeon-Cheol;Lee, Gi-Seong;Choe, Heon-Il;Sa, Gong-Geon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.456-461
    • /
    • 1999
  • In this study, the characteristics of Ultrasonic Transducer fabricated with PZT-Polymer 1-3 type piezoelectric ceramic/polymer composite are investigated. 3-D underwater object restoration using the self-made ultrasonic transducer and modified SCL(Simple Competitive Learning) neural network was presented. The ultrasonic transducer was satisfied with the required condition of commerical ultrasonic transducer in underwater. The modified SCL neural network using the acquired object data $16\times16$ low resolution image was used for object restoration of $32\times32$ high resolution image. The experimental results have shown that the ultrasonic transducer fabricated with PZT-Polymer 1-3 type piezoelectric ceramic/polymer composite could be applied for SONAR system.

  • PDF

Piezoelectric and acoustic properties of piezoceramic/polymer 1-3 composites (압전 세라믹/Polymer 1-3 Composites의 압전 및 음향 특성)

  • Choi, H.I.;SaGong, G.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.727-729
    • /
    • 1992
  • In this study, the piezoelectric composites with 1-3 connectivity have been studied. A piezoelectric ceramics PZT prepared by Flux method is used as a filler in a epoxy Eccogel polymer matrix. The piezoelectric coefficients were increased as PZT volume% increases, and resonance frequency was moved to lower frequency as the sample thickness increased. The acoustic matching impedance with water is lowered than single phase PZT ceramics.

  • PDF

Improvement of Piezoelectric Performance of the CNT/PVDF Composite Film by Enhancing Conductivity of the PEDOT:PSS Electrodes (PEDOT:PSS 전극의 전도도향상에 의한 CNT/PVDF 복합막의 압전성능 개선)

  • Lim, Young-Taek;Lee, Sunwoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.11
    • /
    • pp.716-719
    • /
    • 2016
  • In this paper, we fabricated flexible CNT/PVDF (carbon nanotube / polyvinylidene fluoride) piezoelectric composite device with flexible poly(3,4-ethylenedioxythiophene) : polystyrene sulfonate (PEDOT:PSS) conducting polymer electrode using spray coating method. We tried to improve the piezoelectric performance from the CNT/PVDF composite film by enhancing electrical conductivity of the PEDOT:PSS electrodes. Electrical conductivity of the PEDOT:PSS electrode was enhanced by dipping it into the EG (ethylene glycol) solvent. Changes of chemical composition of the PEDOT:PSS electrode were analyzed with the dipping time by XPS (x-ray photoelectron spectroscopy) in terms of oxygen (O1s). Finally, Piezoelectric performances such as output voltage and current were measured with the dipping time. We found that enhanced electrical conductivity of the PEDOT:PSS electrodes resulted in improvement of the piezoelectric performance of the CNT/PVDF films.

Development of Underwater Wide-band Acoustic Transducer Using the 1-3 Piezoelectric Composite (1-3형 압전복합체를 이용한 광대역 수중 음향 트랜스듀서 개발)

  • Lee, Kyung-Woo;So, Hyoung-Jong;Lim, Sil-Mook;Kim, Won-Ho;Kim, Dae-Yun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.424-431
    • /
    • 2008
  • Recently, it is required that acoustic transducers for underwater detection and communication sensor have wide bandwidth and low operating frequency. In this research, the new acoustic transducer is proposed. This transducer is tonpilz type, and made of 1-3 piezoelectric composites as a driving parts. The developed transducer is evaluated the TVR(transmission voltage response) and RVS(receiving voltage sensitivity) characteristics around $4{\sim}14\;kHz$ frequency range and is compared to conventional tonpilz transducer made of solid piezoelectric ceramics as a driving parts. The resonance frequency of the developed transducer is decreased by 30% and the -3 dB bandwidth is increased by 90%, compared to conventional transducer with same dimensions. The value of TVR is decreased by 9 dB and The value of RVS is the same at resonance frequency.

Study on Non-contact Ultrasonic Transducer for Measurement of Fruit Firmness (과실 경도측정을 위한 비접촉 초음파 변환기 연구)

  • Lee, Sang-Dae;Ha, Tae-Hoon;Kim, Ki-Bok;Kim, Man-Soo
    • Journal of Biosystems Engineering
    • /
    • v.35 no.3
    • /
    • pp.189-196
    • /
    • 2010
  • This study was conducted to develop an non-contact ultrasonic transducer for measurement of fruit firmness. The center frequency of non-contact ultrasonic transducer was 500 kHz. As an active element of non-contact ultrasonic transducer, the 1-3 piezoelectric composite material was selected. That material has high piezoelectric properties such as electro-mechanical coupling factor, $k_t$ and piezoelectric voltage constant, $d_{33}$ and also that material has low acoustical impedance which enables to matching the acoustical impedances between piezoelectric material and air. As a front matching material between 1-3 piezoelectric composite material and air, various kinds of paper with different thickness were tested. To control the dead-zone of the fabricated non-contact ultrasonic transducer, the backing material composed of epoxy resin and tungsten powder were made and evaluated. The fabricated non-contact ultrasonic transducer for fruit showed that the cneter frequency, bandwidth and beamwidth were approximately 480 kHz, 30 % and 12 mm, respectively. It was concluded that non-contact measurement of apple firmness would be possible by using the fabricated non-contact ultrasonic transducer.

Quantitative Nondestructive Evaluation in Composite Beam Using Piezoelectric Transducers (압전 변환기를 이용한 복합재료 보의 비파괴 평가)

  • Lee, Sang-Hyoup;Choi, Young-Geun;Kim, Sang-Tae
    • Composites Research
    • /
    • v.20 no.3
    • /
    • pp.31-36
    • /
    • 2007
  • A quantitative prediction method for initial crack length in a carbon/epoxy (CF/EP) composite beam using active piezoelectric transducers was established in this study. Wavelet Transform (WT)-based signal processing and identification technique in time-frequency domain was developed to facilitate the determination of damage presence and severity. Dynamic response of a CF/EP composites beam containing a continuously expanding crack, coupled with a pair of active piezoelectric disks, was examined under a narrow band excitation, and then applied with the proposed signal processing technique.

Spatially filtered multi-field responses of piezothermoelastic cylindrical shell composites

  • Tzou, H.S.;Bao, Y.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.2
    • /
    • pp.111-124
    • /
    • 1996
  • New active "intelligent" structural systems with integrated self-sensing, diagnosis, and control capabilities can lead to a new design dimension for the next generation high-performance structures and mechanical systems. However, temperature effects to the piezoelectric transducers are not fully understood. This paper is concerned with a mathematical modeling and analysis of a laminated piezothermoelastic cylindrical shell composite exposed to mechanical, electric, and thermal fields. Generic shell equations and solution procedures are derived. Contributions of spatial and time components in the mechanical, electric, and temperature excitations are discussed, and their analytical solutions derived. A laminated cylindrical shell composite with fully distributed piezoelectric layers is used in a case study; its multi-field step and impulse responses are investigated. Analyses suggest that the fully distributed actuators are insensitive to even modes due to load averaging and cancellation. Accordingly, these even modes are filtered from the total response and only the modes that are combinations of m = 1, 3, 5, ${\cdots}$ and n = 1, 3, 5, ${\cdots}$ participating in dynamic response of the shell.

Characteristics of The 1-3 Piezoelectric Composite Transducer Manufactured by Dicing-Filling Method (Dicing-Filling 방법으로 제작된 1-3 압전복합변환자의 특성)

  • Kim, W.S.;Yun, U.H.;Ok, C.I.;Kim, S.B.;Lee, J.K.;Lee, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.33-37
    • /
    • 2000
  • The 1-3 piezoelectric composite transducer with 75 volume percents PZT was fabricated by the dicing-filling method. The resonance modes of the 1-3 transducer have been studied with electric impedance measurement as a function of frequency. The fundamental frequencies of the planar and thickness mode were observed at 0.95MHz and 1.63MHz respectively, but the lateral mode was not observed. In the thickness mode, the electromechanical coupling coefficient of the 1-3 piezoelectric composite transducer, 0.54, was very closed to that of the single phase PZT(0.52). The pulse-echo response by exciting the 1-3 transducer with an electric pulse was observed from the water/reflector interface, and analyzed bandwidth by the spectrum of the impulse response. The quality factor Q for the 1-3 transducer was observed as 1.5 smaller than that of the single phase(80) and then the 1-3 transducer may be used to the broad band type transducer applications.

  • PDF

Development of 1-3 Piezo-Composites made by the method of "Dice & Fill" and Estimation of Their Piezoelectric Characteristics (Dice & Fill 방식을 이용한 1-3 복합재 압전진동자 개발 및 압전특성 평가)

  • 김영덕;정우철;김광일;김흥락;김동수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.869-872
    • /
    • 2000
  • The aim of present work was to fabricate the piezoelectric composite materials of low megahertz applications such as non-destructive testing of materials. Among all the various composites, those with PZT rods embedded in Spurrs epoxy with regular periodicity (1-3 connectivity) was fabricated by dice and fill method. The fabricated size of the PZT cell were 0.18X0.18, 0.28X0.28mm$^2$, respectively. And the volume ratio of the PZT cell were 52, 64%, respectively. The resonant frequency and anti-resonant frequency of the composites were 3.5 MHz and 4.3MHz, respectively. The piezoelectric coupling coefficient were about 38 and 37% and the mechanical quality factor were about 12.7 and 22. These value were very different from these of bulk PZT Plate.

  • PDF