• Title/Summary/Keyword: 1 step protection

Search Result 136, Processing Time 0.024 seconds

Study of Indirect Attack Method of Aerial Fire Firefighting by Helicopter on Forest Fire (헬기에 의한 산불공중간접진화 방법에 관한 연구)

  • Bae, Taek-Hoon;Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • Among the method of aerial fire firefighting, the indirect attack is efficiency way to protect main facilities and it is the aerial fire line construction. According to this study is suggested the fire line construction strategy of indirect attack by helicopter suitable Korea forest fire on theory consideration of indirect attack and experience in practical scene. This study defined that main key points of the fire line construction are accuracy, large quantity, and quickness. Main protection facilities are devided as caution area, warning area, danger area and concern area. Also, it suggested stage-by-stsge from 1 step to 3 step for the aerial fire firefighting correspondence strategy and the fire line construction model. I regard that this study's indirect attack method of the aerial fire firefighting of the fire line construction may be understand about indirect attack tactics and application of indirect attack which is assistance to raise of capability of the aerial fire firefighting with effectiveness and efficiency.

Unusual Mitochondrial DNA Polymorphism of the Blue Mussel (Mytilus edulis) Species Complex on the Southern Coast of Korea

  • Iksoo Kim;Byung-Yoon Min;Myung-Hee Yoon;Myong-Suk Yoo;Doh-Hoon Kim
    • Animal cells and systems
    • /
    • v.3 no.1
    • /
    • pp.79-87
    • /
    • 1999
  • Mitochondrial DNA (mtDNA) from 54 specimens of the blue mussel (Mytilus edulis) species complex sampled from the southern coast of Korea was assayed for polymorphism with a portion of the COIII gene (336 bp). Fifteen haplotypes were found. PAUP, one-step networks, and PHYLIP analyses revealed the presence of two clearly differentiated mitochondrial clades (termed clades B and E), separated by 3.6% of minimum sequence divergence. The distribution pattern of the species appears to be consistent with category II of the phylogeographic pattern sensu (Avise et al., 1987): the presence of two discontinuous and distinct mtDNA genotypes in the same geographic region. This unusual mitochondrial polymorphism was explained by the presence of the Mediterranean species, M. galloprovincialis, possessing mtDNA of both M. galloprovincialis and M. edulis.

  • PDF

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.

LDL-Antioxidant activity of 6-hydroxyeugenol from Spiraea blumei

  • Lee, Dae-Woo;Kim, Ju-Ryoung;Lee, Woo-Song;Cho, Kyung-Hyun;Bae, Ki-Hwan;Jeoung, Tae-Sook
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.265.1-265.1
    • /
    • 2003
  • Low density lipoprotein (LOL) is the major cholesterol carrier in the blood stream. Also, LDL oxidation has been proposed as an important step in the formation of atherosclerotic lesion. Thus, protection of LDL from oxidation is needed to prevent or to retard the progression of atherosclerosis. In this study, 6-hydroxyeugenol was isolated from the methanolic extract of the Spiraea blumei and the sructure was elucidated by spectroscopic data analysis. (omitted)

  • PDF

Improved User Privacy in SocialNetworks Based on Hash Function

  • Alrwuili, Kawthar;Hendaoui, Saloua
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.1
    • /
    • pp.97-104
    • /
    • 2022
  • In recent years, data privacy has become increasingly important. The goal of network cryptography is to protect data while it is being transmitted over the internet or a network. Social media and smartphone apps collect a lot of personal data which if exposed, might be damaging to privacy. As a result, sensitive data is exposed and data is shared without the data owner's consent. Personal Information is one of the concerns in data privacy. Protecting user data and sensitive information is the first step to keeping user data private. Many applications user data can be found on other websites. In this paper, we discuss the issue of privacy and suggest a mechanism for keeping user data hidden in other applications.

MU Fluence Reconstruction based-on Delivered Leaf Position: for IMRT Quality Assurance (세기조절방사선치료의 정도관리를 위한 모니터유닛 공간분포 재구성의 효용성 평가)

  • Park, So-Yeon;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Ye, Sung-Joon
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • The measurement-based verification for intensity modulated radiation therapy (IMRT) is a time-and labor-consuming procedure. Instead, this study aims to develop a MU fluence reconstruction method for IMRT QA. Total actual fluences from treatment planning system (TPS, Eclipse 8.6, Varian) were selected as a reference. Delivered leaf positions according to MU were extracted by the dynalog file generated after IMRT delivery. An in-house software was develop to reconstruct MU fluence from the acquired delivered leaf position data using MATLAB. We investigated five patient's plans delivered by both step-and-shoot IMRT and sliding window technologies. The total actual fluence was compared with the MU fluence reconstructed by using commercial software (Verisoft 3.1, PTW) and gamma analysis method (criteria: 3%/3 mm and 2%/1 mm). Gamma pass rates were $97.8{\pm}1.33$% and the reconstructed fluence was shown good agreement with RTP-based actual fluence. The fluence from step and shoot IMRT was shown slightly higher agreement with the actual fluence than that from sliding window IMRT. If moving from IMRT QA measurements toward independent computer calculations, the developed method can be used for IMRT QA. A point dose calculation method from reconstructed fluences is under development for the routine IMRT QA purpose.

Evaluation of Cyst Loss in Standard Procedural Steps for Detecting of Giardia lamblia and Cryptosporidium parvum in Water

  • Kim, Kyung-Ju;Jung, Hyang-Hee;Lee, Ki-Say
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.4
    • /
    • pp.368-371
    • /
    • 2006
  • The standard procedure outlined by the United States Environmental Protection Agency (US EPA) in Method 1623 for analyzing Giardia lamblia cysts and Cryptosporidium parvum oocysts in water samples consists of filtration, elution, centrifugal concentration, immunomagnetic separation (IMS), and immunofluorescence assay (IFA) followed by microscopic examination. In this study, the extent of (oo)cyst loss in each step of this procedure was evaluated by comparing recovery yields in segmented analyses: (i) IMS + IFA, (ii) concentration + IMS + IFA, and (iii) filtration/elution + concentration + IMS + IFA. The complete (oo)cyst recovery by the full procedure was $52{\sim}57%$. The (oo) cyst loss in the IMS step was only $0{\sim}6%$, implying that IMS is a fairly reliable method for (oo)cyst purification. Centrifugal concentration of the eluted sample and pellet collection before IMS resulted in a loss of $8{\sim}14%$ of the (oo)cysts. The largest (oo)cyst loss occurred in the elution step, with $68{\sim}71%$ of the total loss. The permeated loss of (oo)cysts was negligible during filtration of the water sample with a $1.0-{\mu}m$ pore polyethersulfone (PES) capsule. These results demonstrated that the largest fraction of (oo)cyst loss in this procedure occurred due to poor elution from the filter matrix. Improvements in the elution methodology are therefore required to enhance the overall recovery yield and the reliability of the detection of these parasitic protozoa.

Analytical method for determination of 41Ca in radioactive concrete

  • Lee, Yong-Jin;Lim, Jong-Myoung;Lee, Jin-Hong;Hong, Sang-Bum;Kim, Hyuncheol
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1210-1217
    • /
    • 2021
  • The analysis of 41Ca in concrete generated from the nuclear facilities decommissioning is critical for ensuring the safe management of radioactive waste. An analytical method for the determination of 41Ca in concrete is described. 41Ca is a neutron-activated long radionuclide, and hence, for accurate analysis, it is necessary to completely extract Ca from the concrete sample where it exists as the predominant element. The decomposition methods employed were the acid leaching, microwave digestion, and alkali fusion. A comparison of the results indicated that the alkali fusion is the most suitable way for the separation of Ca from the concrete sample. Several processes of hydroxide and carbonate precipitation were employed to separate 41Ca from interferences. The method relies on the differences in the solubility of the generated products. The behavior of Ca and the interfering elements such as Fe, Ni, Co, Eu, Ba, and Sr is examined at each separation step. The purified 41Ca was measured by a liquid scintillation counter, and the quench curve and counting efficiency were determined by using a certified reference material of known 41Ca activity. The recoveries in this study ranged from 56 to 68%, and the minimum detectable activity was 50 mBq g-1 with 0.5 g of concrete sample.

Effects of the structural strength of fire protection insulation systems in offshore installations

  • Park, Dae Kyeom;Kim, Jeong Hwan;Park, Jun Seok;Ha, Yeon Chul;Seo, Jung Kwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.493-510
    • /
    • 2021
  • Mineral wool is an insulation material commonly used in passive fire protection (PFP) systems on offshore installations. Insulation materials have only been considered functional materials for thermal analysis in the conventional offshore PFP system design method. Hence, the structural performance of insulation has yet to be considered in the design of PFP systems. However, the structural elements of offshore PFP systems are often designed with excessive dimensions to satisfy structural requirements under external loads such as wind, fire and explosive pressure. To verify the structural contribution of insulation material, it was considered a structural material in this study. A series of material tensile tests was undertaken with two types of mineral wool at room temperature and at elevated temperatures for fire conditions. The mechanical properties were then verified with modified methods, and a database was constructed for application in a series of nonlinear structural and thermal finite-element analyses of an offshore bulkhead-type PFP system. Numerical analyses were performed with a conventional model without insulation and with a new suggested model with insulation. These analyses showed the structural contribution of the insulation in the structural behaviour of the PFP panel. The results suggest the need to consider the structural strength of the insulation material in PFP systems during the structural design step for offshore installations.

Effects of Small Scale Post-Harvest Facility and Hygiene Education on the Level of Microbial Safety in Korean Leeks Production (영양부추 생산농가의 소규모 수확후 처리시설 적용과 위생교육에 따른 미생물학적 안전성 향상 효과)

  • Kim, Se-Ri;Kim, Jin-Bae;Lee, Hyo-Sup;Lee, Eun-Sun;Kim, Won-Il;Ryu, Song-Hee;Ha, Jihyung;Kim, Hwang-Yong;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.249-257
    • /
    • 2015
  • The purposes of this study were to develop a small scale post-harvest facility, and consequently to evaluate the effects of applying the facility along with hygiene education on the level of microbial safety in Korean leeks production. A total of 135 samples were collected at three Korean leeks farms in Yangju, Gyeonggi province. Food safety indicators (Aerobic plate count (APC), coliform count, and Escherichia coli) and foodborne pathogens (E. coli O157:H7, Salmonella spp., Staphylococcus aureus, Listeria monocytogenes, and Bacillus cereus) on/in the samples were assessed. The microbial load measured as APC with harvesting tools such as comb, chopping board, and knife, at the farms where the small scale post-harvest facility had been operated (Farms A and B) was lower than that at another farm having no post-harvest facility (Farm C) by 1.44~2.33 log CFU / $100cm^2$. Moreover, the chopping board from Farm C was observed being contaminated with B. cereus at 6.03 log CFU / $100cm^2$. The coliform counts from the samples increased by 0.57~1.89 log CFU/g after leeks was submerged in ground water for washing. E. coli was recovered from leeks, soil, and the ground water used in the washing process, while no E. coli O157:H7, Salmonella spp., and L. monocytogenes was detected. Our results indicated that the small scale post-harvest facility developed in this study as well as the hygiene education played an important role in enhancing the level of microbial food safety in the leeks production environment. However, a disinfection technique could be needed during the washing step in order to prevent a potential contamination.