• Title/Summary/Keyword: 1인 구조자

Search Result 229, Processing Time 0.024 seconds

Chest compression efficiency for three methods of single-person rescuer infant cardiopulmonary resuscitation (1인 구조자 영아심폐소생술시 세 가지 가슴압박 방법의 가슴압박 효율성 비교 : 해양경찰교육원 신임경찰 교육생 대상으로)

  • Hwang, Soon-Jung;Yun, Jong-Geun;Kim, Jung Sun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.107-116
    • /
    • 2020
  • Purpose: We compared three chest compression methods to find an efficient method for performing infant cardiopulmonary resuscitation (CPR) for single rescuers and improving chest compressions quality. Methods: Thirty new marine police trainees at the Korea Coast Guard Education Institute were tested for five sessions using three methods of single rescuer infant CPR: two-finger chest compression, two-thumb encircling chest compression, and two-finger support chest compression. Results: The depth, accuracy, and number of compressions per minute of resuscitation were analyzed for the above three methods. The depth of two-finger chest compression, two-thumb encircling chest compression, and two-finger support chest compression was 3.53±0.20cm, 4.10±0.13cm, and 4.22±0.15cm, respectively. Accuracy was 23.86±12.59%, 54.11±10.8%, 71.55±18.81%, respectively, while the time for one cycle of 30 chest compression was 16.01±10.5 seconds, 16.45±0.85 seconds, and 16.56±0.91 seconds, respectively. Chest compression interruptions were 6.59±0.78 seconds, 7.17±0.37 seconds, and 6.97±0.35 seconds, respectively. The interruptions were consistent with the range of 5-10 seconds suggested by the American Heart Association. Conclusion: When one rescuer performs CPR for an infant in cardiac arrest, a comparative analysis of three methods showed that two-thumb encircling chest compression is the best for accuracy and efficiency of chest compressions.

Synthesis and characterization of sulfonated poly(arylene biphenylsulfone ether) copolymers containing hydroquinone moiety for polymer electrolyte membrane (고분자 전해질 멤브레인용 하이드로퀴논 부분이 포함된 설폰화된 폴리(아릴렌 비페닐설폰 에테르) 공중합체의 합성과 특성평가)

  • Yoo, Dong-Jin
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.121-127
    • /
    • 2010
  • In present work, sulfonated poly(arylene biphenyklsulfone ether) copolymers containing hydroquinone moiety were successfully synthesized using 4,4'-bis[(4-chlorophenyl)sulfonyl]-1,1'-biphenyl(BCPSBP), hydroquinone sulfonic acid potassium salt(sHQ), 4,4'-sulfonyldiphenol and evaluated their characteristics. Three kinds of polymer electrolyte membranes, PBPSEH-HQ00, PBPSEH-HQ10 and PBPSEH-HQ30 were prepared by using mole fraction of sulfonated hydroquinone(sHQ). The structure of the fabricated polymers was analyzed using NMR, IR and GPC. The Mw(weight-average molecular weights) of the polymers were in the range of 62,000-213,000 g $mol^{-1}$, and the molecular weight distribution (Mw/Mn) varied from 1.66-4.04. The thermal analysis of the copolymers was carried out by TGA and DSC. The temperature of Td5% and Td10% was decreased with the mole fraction of sHQ but Tg was increased with the mole fraction. The water uptake, IEC and ion conductivity were increased with increasing the ionic cluster of the polymers. The proton conductivity equal to 9.4 mS $cm^{-1}$ was measured for the PBPSEH-HQ30 membrane at $90^{\circ}C$ and 100% relative humidity. From the observed results it is clear that the prepared hydrocarbon membrane can be considered as suitable polymer electrolyte membrane for the application of PEMFC.

An Extended Scan Path Architecture Based on IEEE 1149.1 (IEEE 1149.1을 이용한 확장된 스캔 경로 구조)

  • Son, U-Jeong;Yun, Tae-Jin;An, Gwang-Seon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.7
    • /
    • pp.1924-1937
    • /
    • 1996
  • In this paper, we propose a ESP(Extended Scan Path) architecture for multi- board testing. The conventional architectures for board testing are single scan path and multi-scan path. In the single scan path architecture, the scan path for test data is just one chain. If the scan path is faulty due to short or open, the test data is not valid. In the multi-scan path architecture, there are additional signals in multi-board testing. So conventional architectures are not adopted to multi-board testing. In the case of the ESP architecture, even though scan paths either short or open, it doesn't affect remaining other scan paths. As a result of executing parallel BIST and IEEE 1149.1 boundary scan test by using, he proposed ESP architecture, we observed to the test time is short compared with the single scan path architecture. Because the ESP architecture uses the common bus, there are not additional signals in multi-board testing. By comparing the ESP architecture with conventional one using ISCAS '85 bench mark circuit, we showed that the architecture has improved results.

  • PDF

Optical Transmittance of Polybenzoxazole Precursor (폴리벤조옥사졸 전구체의 광투과도 연구)

  • 김대겸;김종화;최길영;오재민;이무영;박동원;이광섭;진문영
    • Polymer(Korea)
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2002
  • Poly(ο-hydroxyamide)s as polybenzoxazoles precursors were synthesized by polycondensation from 2,2'-bis(3-amino-4-hydroxyphenyl) hexafluoropropane and various bis-acids. And the polymers were modified to acid-sensitive polyamides by introducing tetrahydropyran in order to impart photosensitivity. A study of optical transmittance at 365 nm, according to the chemical structure of bis-acid, revealed that the polymer derived from 4,4'-oxydibenzoic acid showed better optical transparency than those from other bis-acids. This tendency of optical transmittance could be explained by formation of charge transfer complex. In case of the polymer derived from 4,4'-oxydibenzoic acid, the electron accepting characteristic of bis-acid is reduced by introduction of electron donating group, -O-. Thus, optical transmittance increased due to the diminished formation of intramolecular charge transfer complex. In addition, the optical transmittance increased with increasing the THP content in the polymer. This is attributed to the reduced intermolecular interaction by the loosening of the packing density of the polymer chain.

Historical and Social Environments and the Structure of The Nine Chapters on the Mathematical Art (역사(歷史) 사회(社會) 환경(環境)과 구장산술(九章算術의) 구조(構造))

  • Kang, Shin-Won
    • Journal for History of Mathematics
    • /
    • v.19 no.4
    • /
    • pp.1-12
    • /
    • 2006
  • The Nine Chapters on the Mathematical Art has dominated the history of Chinese mathematics. It served as a textbook not only in China but also in the neighbouring countries and regions. The book is anonymous like many Chinese classics. The Nine Chapters contains 246 problems and their solutions, some of which date back to before the Qin Dynasty $(221\sim207\;B.C)$ and it seems to have been written by various writers over many generations. In this paper, we will investigate the structure of the Nine Chapters from the view points of ancient social environments which entail eventually mathematics in the Nine Chapters.

  • PDF

A Comparative Analysis on Multiple Authorship Counting for Author Co-citation Analysis (저자동시인용분석을 위한 복수저자 기여도 산정 방식의 비교 분석)

  • Lee, Jae Yun;Chung, EunKyung
    • Journal of the Korean Society for information Management
    • /
    • v.31 no.2
    • /
    • pp.57-77
    • /
    • 2014
  • As co-authorship has been prevalent within science communities, counting the credit of co-authors appropriately is an important consideration, particularly in the context of identifying the knowledge structure of fields with author-based analysis. The purpose of this study is to compare the characteristics of co-author credit counting methods by utilizing correlations, multidimensional scaling, and pathfinder networks. To achieve this purpose, this study analyzed a dataset of 2,014 journal articles and 3,892 cited authors from the Journal of the Architectural Institute of Korea: Planning & Design from 2003 to 2008 in the field of Architecture in Korea. In this study, six different methods of crediting co-authors are selected for comparative analyses. These methods are first-author counting (m1), straight full counting (m2), and fractional counting (m3), proportional counting with a total score of 1 (m4), proportional counting with a total score between 1 and 2 (m5), and first-author-weighted fractional counting (m6). As shown in the data analysis, m1 and m2 are found as extreme opposites, since m1 counts only first authors and m2 assigns all co-authors equally with a credit score of 1. With correlation and multidimensional scaling analyses, among five counting methods (from m2 to m6), a group of counting methods including m3, m4, and m5 are found to be relatively similar. When the knowledge structure is visualized with pathfinder network, the knowledge structure networks from different counting methods are differently presented due to the connections of individual links. In addition, the internal validity shows that first-author-weighted fractional counting (m6) might be considered a better method to author clustering. Findings demonstrate that different co-author counting methods influence the network results of knowledge structure and a better counting method is revealed for author clustering.

Thermal and Optical Properties of Poly{1-(Cholesteryloxycarbonylalkanoyloxy)ethylene}s (폴리{1-(콜레스테릴옥시카보닐알카노일옥시)에틸렌}들의 열 및 광학 특성)

  • Jeong, Seung-Yong;Ma, Yung-Dae
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.144-152
    • /
    • 2009
  • The thermal and optical properties of poly {1-(cholesteryloxycarbonylalkanoyloxy) ethylene}s (PCALEn, n=2$\sim$8,10, the number of methylene units in the spacer) were investigated. All of the homologues formed monotropic cholesteric phases with left-handed helical structures. PCALEn with n=2 or 10, in constrast with PCALEn with $3{\leq}n{\leq}8$, did not display reflection colors over the full cholesteric range, suggesting that the helical twisting power of the cholesteryl group highly depends on the length of the spacer connecting the cholesteryl group to the polyethylene chain. The glass transition temperatures decreased with increasing n. The isotropic-cholesteric phase transition temperatures decreased with increasing n up to 7 and showed an odd-even effect. However it became almost constant when n is more than 7. This behavior is rationalized in terms of the change in the average shape of the side chain on varing the parity of the spacer. This rationalization also accounts for the observed variation of the entropy gain for the clearing transition. The thermal stability and degree of order in the mesophase and the temperature dependence of the optical pitch observed for PCALEn were significantly different from those reported for cellulose tri(cholesteryloxycarbonyl)alkanoates. The results were discussed in terms of the differences in the chemical structure and flexibility of main chain and the number of the mesogenic units per repeating unit.

Preparation and Characterization of Proton Conducting Crosslinked Membranes Using Polymer Blends (폴리머 블렌딩을 이용한 수소 전도성 가교형 막의 제조와 그 특성)

  • Kim, Jong-Hak;Lee, Do-Kyoung;Choi, Jin-Kyu;Seo, Jin-Ah;Roh, Dong-Kyu
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.311-317
    • /
    • 2007
  • Proton conducting crosslinked membranes have been prepared by polymer blending, which consist of poly(vinyl alcohol-co-ethylene) (PVA-co-PE) and poly(styrene sulfonic acid-co-maleic acid) (PSSA-co-PMA) at 50 : 50 wt ratio. Two kinds of PSSA-co-PMA copolymer with 3 : 1 and 1 : 1 the molar ratio of PSSA to PMA wereused as a proton conducting source. The ethylene content of PVA-co-PE was also changed as 0, 27 and 44 mol%. The membranes were thermally crosslinked via the esterification reaction between -OH of PVA and -COOH of PMA, as demonstrated by FT-IR spectroscopy (PVA-co-PE)/(PSSA-co-PMA) membranes with 3 : 1 the molar ratio of PSSA to PMA showed higher ion exchange capacity (IEC), lower water uptake and higher proton conductivity than those with 1 : 1 molar ratio. As the PE concentration increased, the IEC values, water uptake and proton conductivities decreased continuously. These properties were elucidated in terms of competitive effect between the concentration of sulfonic acid, hydrophilicity and the crosslinked structure of membranes.

Microstructural analysis of coal bottom ash-${Na_2}O-{Li_2O}$ system glass-ceramics (석탄 바닥재-${Na_2}O-{Li_2O}$계 결정화 유리의 미세구조 분석)

  • Kang, Seung-Gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • The glass-ceramics composed of coal bottom ash produced from a thermal power plant, $Na_{2}O$ and $Li_{2}O$ as a flux agent and $TiO_2$ as a nucleation agent were fabricated and its microstructures were analyzed. The nepheline was a major crystal phase in the glass-ceramics fabricated and its amount increased with $TiO_2$ addition. The glass-ceramics without $TiO_2$ addition had the thick surface crystals induced by a surface-crystallization mechanism and no crystal in the interior matrix. The surface crystallization, however, was restrained and the interior matrix was completely crystallized showing dendrite shape spread with fine particles < $1{\mu}m$ when added with $TiO_2$ above 4 wt%. For the glass-ceramics containing 6 wt% $TiO_2$, the $5{\mu}m$-long dendrite crystal; were interlocked each other which could suppress the crack propagation effectively at the external loading applied.

Cost Analysis of Fall Accidents in Domestic Construction Industry (국내 건설산업의 추락재해 비용 분석)

  • Sa, Young Bae;Choi, Sung Uk;Cho, Won Cheol;Lee, Tae Shik
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • This study analyzed the direct costs of fall accidents, which have the highest accident rate, for domestic construction industry workers. Firstly, the average insurance payment per person due to fall accidents in the construction industry is around 19 million won (18,971,000 won). Given that the average number of workers suffering fall accidents over ten years is 5,863, the total cost of losses from fall accidents is about 1.1 trillion won (111,360,000,000 won). Secondly, a cost-based economic feasibility analysis was done to develop nonstructural preventive measures for fall accidents. Since there was no data expressing the costs and effects of preventive measures in terms of monetary value, the economic feasibility analysis was attempted with a focus on how much the newly introduced preventive measures can reduce the accident loss costs due to fall accidents. Thirdly, if the accident loss size is grasped and the preventive measures for the causes of fall accidents are developed and strictly implemented, the insurance fee that can reduce the accident loss costs can be determined. Further study is needed to estimate the benefit of the accident loss cost reduction seen from the cost-based approach method.