• Title/Summary/Keyword: 1,2,4-trimethylbenzene

Search Result 23, Processing Time 0.023 seconds

Bacterial Reverse Mutation Test of 1,2,4-trimethylbenzene (1,2,4-trimethylbenzene의 미생물복귀돌연변이시험)

  • Kim, Soo-Jin;Cho, Hae-Won;Rim, Kyung-Taek;Maeng, Seung-Hee;Kim, Hyeon-Yeong
    • Environmental Analysis Health and Toxicology
    • /
    • v.21 no.4 s.55
    • /
    • pp.317-322
    • /
    • 2006
  • We have investigated the genotoxicity of 1,2,4-trimethylbenzene using Ames reverse mutation test. In Ames reverse mutation test, 1,2,4-trimethylbenzene treatment at the dose of 100, 50, 25, 12.5, $6.25{\mu}g/plate$ did not induce mutagenicity in Salmonella typhimurium TA98, TA100, TA1535, TA1537 and in Escherichia coli WP2uvrA with and without metabolic activation. These results indicate that 1,2,4-trimethylbenzene has no mutagenic potential under the rendition in this study.

Analysis of the Metabolites of 1,2,4-Trimethylbenzene by Capillary Electrophoresis (모세관 전기영동법을 이용한 1,2,4-트리메틸벤젠 대사체의 분석)

  • Kang, Jong-Seong;Hong, Cheong-Hee;Lim, Jeong-Mi;Lee, Yong-Moon;Jang, Jae-Yeon
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.326-331
    • /
    • 1999
  • The metabolites of 1,2,4-trimethylbenzene (TMB) were synthesized and determined by capillary electrophoresis (CE). The optimum conditions of CE for the separation and determination of 3,4-, 2,4-, 2,5-dimethylbenzoic acid and 3,4-, 2,4-, 2,5-dimethylhippuric acid from the rat urine were as following: the fused silica capillary($75{\mu}m$ i.d. ${\times}$ 36 cm length, 29 cm to detector) was used and kept at $15^{\circ}C$. The applied voltage was 10㎸ and compounds were detected at UV 210 mnm and 254 nm. The running electrolyte was 0.1 M phosphate buffer (pH 7) containing 15 mM of ${\beta}-CD$ and 3% of 2-propanol. The relative amount of the metabolite of 1,2,4-TMB in the rat urine was 56.7% of 3,4-isomer, 30.5% of 2,4-isomer and 12.8% of 2,5-isomer. This method can be applied to the analysis of TMB-metabolites in human urine.

  • PDF

Rapid Analytical Method of Volatile- and Semivolatile Organic Compounds in Water and their Monitoring in Water Treatment Plants (물 시료 중 휘발성 및 반휘발성 유기물질들의 빠른 분석법 및 정수처리 단계별 모니터링)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.240-250
    • /
    • 2004
  • A gas chromatography-mass spectrometric (GC-MS) assay method was developed for the rapid and sensitive determination of volatile- and semivolatile organic compounds in water. Two hundreds mL of water sample was extracted in a 250 mL separatory funnel with 1 ml of pentane at pH 6.5. Fluorobenzene and 1,2-dichlorobenzene-d4 as internal standards were added to water sample and the solution was mechanically shaken for 5 min and analyzed by GC-MS (selected ion monitoring) without more any concentration or purification steps. The peaks had good chromatographic properties and the extraction of these compounds from water also gave relatively high recoveries with small variations. The range of detection limits of the assay was 0.5-10 ng/L. Turnaround time for up to about 40 samples was one day. This method is simple, convenient, and can be learned easily by relatively inexperienced personnel. This method was used to analyze 15 volatile- and semivolatile organic compounds in water of a Lake, and raw and treated water from three Water Treatment Plants in Korea. As the analytical results, benzene, toluene, xylene, isopropylbenzene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, naphthalene and 2,4,6-trichlorophenol were detected at concentrations of up to 0.4, 1.9, 1.3, 0.2, 1.8, 13.0, 1.7 and $1.1{\mu}g/L$, respectively. But chlorobenzene, trichloroethylene, tetrachloroethylene, ethylbenzene, n-butylbenzene and dibromochloropropane levels during that period were not significant. The removal effect of the compounds in three Water Treatment Plants was calculated. The compounds studied were generally removed during conventional water treatment, especially during the active carbon filtration.

Determination of 3,4-Dimethylhippuric Acid and Creatinine from the Urine of Workers Exposed to 1,2,4-Trimethylbenzene (1,2,4-트리메틸벤젠에 피폭된 노동자의 뇨 중 3,4-디메틸히푸르 산과 크레아티닌의 정량)

  • Lim, Jeong-Mi;Jang, Jae-Yeon;Lee, Yong-Moon;Kang, Jong-Seong
    • YAKHAK HOEJI
    • /
    • v.41 no.6
    • /
    • pp.692-697
    • /
    • 1997
  • Creatine and 3,4-Dimethylhippuric acid (3,4-DMHA), a glycine conjugate of 1,2,4-trimethyl-benzene (1,2,4-TMB) were determined in the urine of workers exposed to 1,2,4-TMB vapor. The best condition for the simultaneous determination of 3,4-DMHA and creatine by high performance liquid chromatography was obtained by reverse phase $C_{18}$ column (4.6${\times}$150mm, 5${\mu}m$) as stationary phase and 20% acetonitrile in 20mM phosphate buffer (pH 3.0) containing 4mM sodium octylsulfate(SOS)as mobile phase. The recovery of 3,4-DMHA spiked to blank urine in the range of 1~5${\mu}g$/ml was about 96%. The concentration of urinary 3,4-DMHA of workers had a positive correlation with the environmental level of 1,2,4-TMB (r=0.866). The data suggest that urinary 3,4-DMHA concentration is a useful biological index for 1,2,4-TMB exposure.

  • PDF

Reactions of Trimethylbenzenes over Mordenite Catalysts (모더나이트 촉매상에서 트리메틸벤젠의 반응)

  • Byoung Joon Ahn;Hak Ze Chon
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.3
    • /
    • pp.166-171
    • /
    • 1981
  • The reactions of trimethylbenzenes were investigated over dealuminated, cation-exchanged mordenite catalysts. Higher reaction temperature favored the formation of disproportionation products. In the reaction of 1,2,4-trimethylbenzene, the formation of 1,3,5-trimethylbenzene and the disproportionation products decreased sharply with reaction time. The product distribution, especially the distribution of trimethylbenzenes, suggests that the effective pore diameter of Ba-exchanged dealuminated mordenite catalysts lies somewhere between 8.1 and 8.6${\AA}$.

  • PDF

A Study on the Characteristic Trace of Water Quality Pollutants in the Industrial Wastewater (업종별 산업폐수의 수질오염물질 배출 특성)

  • Park, Sun Ku;Kim, Sung Soo;Ko, Oh Suk
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.141-150
    • /
    • 1999
  • Twenty organic chemical substances, tetrachloroethylene, toluene, ethylbenzene, p-xylene, m-xylene, isopropyl benzene, stylene, bromobenzene, 1,3,5-trimethylbenzene, 2-chlorotoluene 1,2,4-trimethylbenzene, p-isopropyltoluene, 4-chlorotoluene, n-butylbenzene, 1,2,4-trichlorobenzene, naphthalene, tert-butylbenzene, sec-butylbenzene, phenol, isopropyl benzene hydroperoxide were isolated from untreated and treated wastewater collected at 76 companys of 9 types industry in the basin of Young San River. Their organic compounds were elucidated by Gas Chromatography/Mass Spectrometry (GC/MS) and by comparison with each standard reagents. Especially, phenol compound is detected from effluent water but not detected from plant wastewater in the chemical industry. Heavy metal, which are Cr, Mn, Cu, Zn, Cd, Pb, As, Al and Fe, are contained in the plant wastewater of all industry, Fe, Al of them is more detected than the other metals in plant wastewater. Cr, Cd, Pb, As is contained much in plant wastewater of electricity and electron, metal molding industry. Nine metals is nearely treated when plant wastewater is treated, and then the concentration of each other metals is detected below water quality standard or not detected by using AA.

  • PDF

포항공단지역 산업체 특성별 VOCs 배출 특성 분석

  • Kim, Jong-Tae;Gwon, Gi-Dong;Kim, Mo-Geun;Lee, Hwa-Su;Mun, Seung-Jae;Jeon, Hui-Dong;Jo, Wan-Geun
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.92-94
    • /
    • 2006
  • 포항공단의 VOCs 배출특성을 분석한 결과 업체에 따른 특성, 공정에 따른 특성이 매우 다양한 것으로 나타났다. 이는 사용하는 원료, 부원료 및 연료 등이 다양하고, 생산하는 제품에 따라 공정의 특성에도 차이가 있기 때문인 것으로 사료된다. 5개 업체에서 모두 발견된 물질은 BTEXS이며, 일부 업체에서는 Chloroform, 1-ethyl-4-methylbenzene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene등의 물질도 함께 검출되었다.

  • PDF

The study on the measurement of volatile organic compounds in the air of A and B industrial area (모 공단 대기 중 휘발성 유기화합물 측정에 관한 연구)

  • Shin, Ho-Sang;Ahn, Hye-Sil
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.130-144
    • /
    • 2004
  • Recently, the air pollution in A and B industrial area has become one of the most important issues, then 60 VOCs in the area were measured using a highly sensitive method. The VOCs were adsorbed onto Carbotrap using air sampler and subsequently desorbed by a thermal desorber system into gas chromatograph-mass spectrometry (TDS-GC-MS). The peaks of all compounds had good chromatographic properties and offered very sensitive response for the EI-MS (SIM). Method detection limits (MDL) ranged from 0.01 to 0.1 ppt(v/v), and linearities of calibration curves were over 0.995. We analyzed total 90 atmosphere air samples of A and B industrial complex using the method. Benzene, toluene, ethylbenzene, xylene, n-hexane, fluorotrichloromethane, carbon tetrachloride, 1,2-dichloroethane, 1,1,1-trichloroethane, trichloroethylene, tetrachloroethylene, styrene, 1,3,5-trimethylbenzene, 1,2,4-trimethylbenzene, sec-butylbenzene and naphthalen were identified as the major compounds in the air, and their average concentrations were 0.81, 5.02 1.30, 3.0, 0.81, 37.9, 0.07, 0.15, 0.15, 0.79, 0.06, 0.33, 0.03, 0.12, 0.23, and 0.35 ppb(v/v), respectively. The concentrations of VOCs were low in summer and high in fall or winter. When the concentrations detected in air compare with WHO's norm, no case exceed it.

Concentration level of Volitile Organic Compounds about the Air of Source Boundary Site in Seongseo Industrial Complex (대구성서산업단지 발생원부지경계 대기 중 휘발성유기화합물질의 농도수준)

  • An Sang-Young;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2005
  • The concentrations of volatile organic compounds(VOCs) in the ambient air were measured at various point(Source, source boundary) in Seongseo industrial complex during May to November 2003. Air samples were collected in Silcocan canister $(1{\ell},\;6{\ell})$ and analyzed using a cryogenic preconcentration system and GC/MSD. We identified 37 species by the US EPA(TO-14 method). The result showed a variety distribution of the con­centration, Higher concentrations of BTX, Styrene, 1,3,5-Trimethylbenzene, 1,2,4-Trimethylbenzene were observed at the sampling sites. They seemed to be emitted from the facility of wastewater treatment, reaction tank of chemistry factory and facility of Tenter. The concentrations of VOCs contents in Seongseo industrial complex were generally higher than those in Yeosu complex and Ulsan complex, although those were similar in Sihwa­Banwol complex.

Characteristics of Aromatic Hydrocarbons Measured in an As-built Building (입주 전 신축 건물의 사무실내 방향족 탄화수소의 농도 특성)

  • 나광삼;배귀남;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.5
    • /
    • pp.545-552
    • /
    • 2000
  • Eight aromatic hydrocarbons were quantified in a newly constructed building before occupancy during the period of November 1997 to January 1998. Air samples were collected in 6 L stainless steel canisters for 8 hours based on working hour. It was found that the measured total concentration of aromatic hydrocarbons decreases rapidly with time up to a steady-state value. However, the fractions for each aromatic hydrocarbon were greatly changed with time. The concentration ratios of indoor to outdoor for aromatic hydrocarbons are greater than 1 during early period of the measurement, and the ratios decrease with time. The concentrations of toluene, m+p-xylene, ethylbenzene, and o-xylene are much higher than those of styrene, 1, 2, 4-trimethylbenzene, and 1, 3, 5-f trimethylbenzene in indoor air. The concentration fractions of m+p-xylene, ethylbenzed, and o-xylene in indoor air are about twice as hight as those in outdoor air measured during the similar period. It was concluded that the aromatic hydrocarbons were emitted from building materials, paints, and adhesives in an-built building.

  • PDF