Chemical Composition, Nutritional Value, and Saponin Content in the Spring Sap of Acer mono (고로쇠나무 수액(樹液)의 화학적(化學的) 성분(成分), 영양가치(營養價置)와 사포닌 함유(含有) 여부(與否)에 관(關)한 연구(硏究))

  • Lee, Kyung Joon;Park, Jong Young;Park, Kwan Hwa;Park, Hoon
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.4
    • /
    • pp.415-423
    • /
    • 1995
  • This study was conducted to analyze the chemical composition, nutritional contents, and saponin in the xylem sap of Acer mono Max. From Feb 25 to Mar 4, 1994, spring sap was collected by making holes with 1.7cm diameter on the trunk of trees in Mt. Baekwoon and Mt. Jiri. Sugars were quantified by HPIC, amino acids by amino acid analyzer, saponins by TLC, HPLC, and $^1H$ & $^{13}C$ NMR. Major component of the sap was sucrose at a concentration range of 0.68 to 2.01%. Following minor components were found: glucose at 0.03-0.11%, and fructose at 0.01-0.03% as sugars, lipid at 0.03%, threonine at 0.152%, lysine at 0.038%, arginine at 0.068% as amino acids, ash at 0.1%, Ca at 175ppm, Fe at 2ppm, P at 19ppm, K at 16ppm, Na at 31ppm as minerals, vitamin $B_1$ at 0.6ppm, vit. $B_2$ at 0.1ppm, and vit. C at 19ppm. A trace of phenolic compounds was found by TLC, while saponin commonly reported in high-quality ginseng roots was not found in maple sap. It is concluded that sap of Acer mono contains a good variety of natural compounds such as sugars, amino acids, Ca, Fe, and vitamins to serve as an excellent source of very natural and health-promoting drink.

  • PDF

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

MHC Class II Allele Association in Korean Children With IgA Nephropathy and its Role as a Prognostic Factor (한국인 IgA 신병증 환아에서 MHC Class II유전자형과 예후와의 관계 분석)

  • Kim Pyung Kil;Yook Jinwon;Kim Ji Hong;Jang Yoon Soo;Shin Jeon-Soo;Choi In-Hong
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.33-39
    • /
    • 2000
  • Purpose: Our study was designed to investigate the association of MHC Class II (DR, DQ) allele with IgA nephropathy and its significance as a prognostic factor for progression to ESRD Material and Methods: 69 children with IgA nephropathy with normal renal function(serum creatinine $\leq$ 1.5mg/dL) was classified as group A and 70 patients who received renal transplantation due to IgA nephropathy were selected as group B. The HLA-DQB1 and HLA-DRB1 alleles were studied by polymerase chain reaction using sequence specific primers. We have compared the difference in alleles between these two groups and with normal control and also examined any possible effect of the MHC class II genes on the histopathological severity and prognosis of IgAN. Results: Mean age was $8.8{\pm}2.9$ years in group A and $35.0{\pm}15.5$ years in group B. Male to female ratio was 2.8:1 in group A and 2.5:1 in group B. There was a significantly higher frequency of HLA-$DQB1^*03\;and\;DQB1^*05$ in Group B. The frequency of HLA-$DQB1^*0302\;and\;^*05031$ allele had increasing tendency in Group B(P<0.05). HLA-$DRB1^*03\;and\;^*05$ were more common in Group B(P<0.05). HLA-$DRB1^*04$ allele was the most common DR alleles in both group, but there was no statistical significance. There were no significant correlation with MHC class 13 genes on the hjstopathological severity in Group A. Conclusion: In conclusion, $HLA-DQB1^*0302\;and\;HLA-DQB1^*05031 $ allele seemed to be more common in transplanted patients compared to group with normal renal function suggesting that this allele is associated with poor prognosis in IgAN. However larger studies and follow up are required to confirm this due to uncharacterized heterogeneity in etiopathogenesis of IgA nephropathy and possibly one or more than one gene may exert influence in determining susceptibility to the diseases.

  • PDF

Analysis of Nutritional Components and Physicochemical Properties of Hot-air Dried Jerusalem Artichoke (Helianthus tuberosus L.) Powder (열풍 건조한 돼지감자 분말의 영양성분 및 이화학적 특성 분석)

  • Kim, Ha-Neul;Yu, Seok-Yeong;Yoon, Won-Byong;Jang, Sun-Min;Jang, Yong-Jin;Lee, Ok-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.73-78
    • /
    • 2014
  • This study investigated the nutritional components and physicochemical characteristics of Jerusalem artichoke. The moisture, crude protein, crude fat, crude ash and carbohydrate content of the Jerusalem artichoke were $5.06{\pm}0.08$, $8.30{\pm}0.26$, $0.70{\pm}0.16$, $5.04{\pm}0.03$, and 80.90%, respectively. The total sugar content of Jerusalem artichoke was $50.48{\pm}1.11$ mg/g, and the Hunter color space coordinates were $L=94.16{\pm}0.03$, $a=0.32{\pm}0.01$ and $b=0.30{\pm}0.01$. The water binding capacity and water activity of the Jerusalem artichoke were $4.06{\pm}0.16$ g/g and $0.245{\pm}0.005$, respectively. The total amino-acid content of the Jerusalem artichoke was $1.337{\times}10^4$ mg/kg, and essential amino acid was 2,737 mg/kg. The total free sugar of the Jerusalem artichoke was 4.12%. Linoleic acid (0.21%) was found to be a common fatty acid in the Jerusalem artichoke. Among the minerals, potassium (2,489 mg%) was found to be the most abundant in the Jerusalem artichoke. The total phenol and flavonoid contents were $3.06{\pm}0.07$ mg GAE/g and $1.89{\pm}0.03$ mg QE/g, respectively. The vitamin C content of the Jerusalem artichoke was $3.43{\pm}0.07$ mg%.

Studies on Growth and Biomass Production of Abies koreana Seedlings under Different Relative Light Intensity (상대광도 차이에 따른 구상나무 유묘의 생장과 물질생산에 관한 연구)

  • 조혜경;홍성각;김종진
    • Journal of Korea Foresty Energy
    • /
    • v.20 no.2
    • /
    • pp.58-68
    • /
    • 2001
  • This study was carried out to investigate the growth and biomass production of Abies koreana seedlings under different relative light intensity. The 5-year-old potted seedlings were grown for 24 months under different light intensity of 100%, 50%, 30%, 10% and 2% of the natural full light intensity. The results were as follows: 1. Height growth was similar in the seedlings under different light intensities except in 2% of the full sun light intensity, having shown the lowest height growth. 2. Root collar diameter growth was reduced gradually by decreasing of the relative light intensity. 3. The seedlings which were grown under relatively low light intensity showed the later starting date of the stem growth in the next spring and showed the smaller number of new needles, and the smarter number and the shorter length of new shoot of the seedlings. 4. Total dry mass including the dry mass of leaves, shoot and root was reduced by decreasing of the relative light intensity. 5. In case of the seedling grown in one year shading condition, the ratio of the dry mass of current-year needles and stem to that of the above one-year-old needles and stem was ranged from 0.99$\pm$0.25 to 1.06$\pm$0.06 and was not significally different among the seedlings grown under 100%, 50% and 30% of the relative light intensity. And the radio was ranged from 0.60$\pm$0.04 to 0.52$\pm$0.03 in the seedlings grown under 10% and 2% of the relative light intensity, respectively. In case of the seedling grown in two years shading, the ratio of the dry mass of current-year needles and stem to that of the above one-year-old needles and stem was ranged from 0.79$\pm$0.04 to 1.00$\pm$0.03 and was not significally different among the seedlings grown under 100, 50, 30% and 10% of the relative light intensity. And the ratio was 0.29$\pm$0.03 in the seedlings grown under 2% of the relative light intensity, respectively. 6. T/R ratio of the seedlings grown in one year shading condition was ranged from 3.35$\pm$0.33 to 4.61$\pm$0.25 and was not significantly different among the relative light intensities of 100%, 50%, 30% and 10%. The seedlings grown under 2% of relative light intensity showed the highest T/R ratio of 7.36$\pm$0.15. In case of the two years shadings the T/R ratio was ranged from 1.76$\pm$0.11 to 3.12$\pm$0.19 and increased as relative light intensity decreased except 2.01$\pm$0.14 in 2% of relative light intensity.

  • PDF

A Comparison of Gases and Heavy Metals in Blood between Urban and Rural Teenager (도시(都市)와 농촌(農村) 약년자(若年者)의 혈액(血液)가스 및 중금속(重金屬) 함량(含量) 비교(比較))

  • Lee, Sang-Sook;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.129-136
    • /
    • 1985
  • This paper is carried out to determine the venous blood gas components and heavy metals, such as lead, cadmium and copper, in blood between urban and rural teenager. The subjects were 34 in urban, Taegu city and 37 in rural, Euisung-Gun. But smokers were excluded. The specimens were sampled in May, 1985. The heavy metals were analyzed by atomic absorption spectrophotometry (IL. 551) and carboxy-Hb, Met-Hb, Hb, $O_2\;and\;CO_2$, blood gas analyzer (IL. 1301) and CO-oximeter (IL. 282). In urban group, $PO_2\;and\;O_2-Hb$ were significantly lower than in rural (p<0.01, p<0.03, respectively), and ${HCO_3}^{-}\;and\;TCO_2$ were significantly higher than in rural (p<0.01, p<0.01, respectively). CO-Hb concentration was rather higher in the rural group than the urban (p<0.03), other Met-Hb was higher in urban group than in the rural (p<0.01). Lead and cadmium were also significantly higher in the urban group (p<0.03, p<0.02, respectively).

  • PDF

Water Quality of Some Spring Waters in Pusan Area (부산시내에 산재하는 몇몇 약수터 약수의 수질)

  • KIM Yong-Gwan;CHO Hyeon-Seo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.6
    • /
    • pp.538-544
    • /
    • 1985
  • This study was carried cut to evaluate the water quality of spring waters in Pusan area(see Fig. 1). In this experiment, twenty-five water samples were collected from 5 stations from December 1983 to August 1984. Range and mean values of constituents of the samples are as follows: pH $5.80{\sim}7.25$, 6.60; water temperature $6.0{\sim}23.0^{\circ}C,\;12.9^{\circ}C$; total residue $33.0{\sim}325mg/l$, 121.2mg/l; alkalinity $4.75{\sim}51.6mg/l$, 24.1mg/l; hardness $9.47{\sim}85.0mg/l$, 30.3mg/l; electrical conductivity $0.495{\sim}2.750{\times}^2{mu}{\mho}/cm,\;1.239{\times}10^2{\mu}{\mho}/cm$;turbidity $0.54{\sim}7.80$NTU, 2.04NTU; $KMnO_4$ consumed $0.51{\sim}8.47mg/l$, 1.96mg/l; chloride ion $4.91{\sim}36.0mg/l$, 12.55mg/l; fluoride ion ND-0.30ppm, 0.08ppm; nitrate-nitrogen ND-8.94mg/l, 1.94m:g/l; nitrite-nirogen ND-0.10mg/l, 0.03mg/l; ammonia-nitrogen ND-0.16mg/l, 0.03mg/l: phosphate-phosphorus ND-0.09mg/l, 0.03mg/l; silicate-silicious $0.42{\sim}22.7ng/l$, 7.96mg/l; copper ND-10.5ppb, 2.46ppb; lead ND-22.7ppb, 3.54ppb; zinc ND-103ppb, 21.33ppb; iron $20.3{\sim}2,800ppb$, 801.72ppb, respectively. Arsenic, cyan, cadmium, manganese, mercury, chrome and phenol were not detected. Total residue, electrical conductivity, turbidity and chloride ion of station 1 (Milrakdong) were higher than others as 178.1mg/l, $2.127{\times}10^2{\mu}{\mho}/cm$, 3.16NTU and 16.32mg/l. The concentration of silicious had a great influence on precipitation. The concentration of fluoride ion of spring waters was lower as 0.08ppm than the criterion for drinking water as 1ppm, while iron was exceed 2.7 times as 801.72ppb.

  • PDF

Usefulness of $^{18}F$-FDG PET/CT in Locoregional Recurrence of Differentiated Thyroid Cancer: Comparison PET/CT to PET and Neck Ultrasonography for Biopsy-proven Lesions (갑상선유두암 재발 진단에서 $^{18}F$-FDG PET/CT와 경부초음파검사 병용의 유용성: PET, 경부초음파검사 그리고 혈청 티로글로불린 (thyroglobulin)의 비교)

  • Kim, Kun-Ho;Shong, Min-Ho;Seo, Young-Duk;Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.411-420
    • /
    • 2009
  • Purpose: The aim of this study was to investigate the usefulness of $^{18}F$-FDG PET/CT with neck ultrasonography (neck US) in patients with recurrent, papillary thyroid cancer. Material and methods: This retrospective study (December 2006 to April 2008) enrolled sixty-one patients (ninety-one lesions) who underwent high-dose $^{131}I$-ablation therapy after total thyroidectomy, and evaluated recurred papillary thyroid cancer. All lesions were confirmed by histopathology and compared histopathologic findings to PET, PET/CT, and neck US findings. Results: In sixty-one patients (57 women, 4 men; age range, 24-81 years, mean 49 years; 61 papillary carcinomas), the sensitivity, specificity, accuracy of $^{18}F$-FDG PET/CT was 87.2%, 64.0%, 78.1% on a patient basis and 92.3%, 66.7%, 80.9% on a lesion basis, respectively. The sensitivity, specificity, accuracy of $^{18}F$-FDG PET was 71.8% (p=0.03), 59.0% (p=1.00), 67.2% (p=0.03) on a patient basis and 78.8% (p<0.01), 64.1% (p=1.00), 72.5% (p=0.02) on a lesion basis, respectively. The sensitivity, specificity, accuracy of neck US was 71.1% (p=0.07), 52.2% (p=0.75), 63.9% (p=0.05) on a patient basis and 71.2% (p<0.01), 61.5% (p=1.00), 67.0% (p=0.06) on a lesion basis, respectively. Combined $^{18}F$-FDG PET/CT with neck US improved the sensitivity, specificity, accuracy to 94.7% (p=0.50), 82.6% (p=0.13), 90.2% (p=0.03) on a patient basis and 96.2% (p=0.50), 89.7% (p<0.01), 93.4% (p<0.01) on a lesion basis, respectively. Conclusion: $^{18}F$-FDG PET/CT demonstrated significantly higher sensitivity than neck US for the detection of recurred papillary thyroid cancer lesions. Furthermore, combined $^{18}F$-FDG PET/CT with neck US showed more improved sensitivity, specificity, accuracy for diagnosis of recurrent papillary thyroid cancer.

Crystal Structure and Mossbauer Studies of 57Fe Doped TiO2 (57Fe가 치환된 TiO2의 결정학적 및 뫼스바우어 분광학적 연구)

  • Lee, Hi-Min;Shim, In-Bo;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.6
    • /
    • pp.237-242
    • /
    • 2003
  • $Ti_{1-x}$$^{57}$ F $e_{x}$ $O_2$(0.0$\leq$x$\leq$0.07) compounds were fabricated using the sol-gel method, and the crystal structure and magnetic properties were investigated as a function of doped $^{57}$ Fe concentration. X-ray diffraction patterns showed a pure anatase single phase, without any segregation of Fe into particulate. With varying $^{57}$ Fe concentration, we could observe unusual magnetic phenomena in these materials. Doping $^{57}$ Fe into the Ti $O_2$ nonmagnetic semiconductor formed magnetic properties, but the gradual increase of $^{57}$ Fe concentration decreased rapidly the ferromagnetic properties rather than enhanced the ferromagnetic properties. Obvious ferromagnetic behavior was shown for the samples with x$\leq$0.01, while paramagnetic behavior was shown for the sample with x$\geq$0.03. These phenomena could be verified using Mossbauer measurement. Separation of the ferromagnetic phase (sextet) and the paramagnetic phase (doublet) of the samples with different $^{57}$ Fe concentration was characterized. Samples with x$\leq$0.01 have sextet and doublet simultaneously, but samples with x$\geq$0.03 have only doublet at room temperature. This indicates that the sample x$\leq$0.01 have the ferromagnetic phase at room temperature. This result corresponded with the M-H loops referenced above and reveals an interesting feature that there is a critical limit of $^{57}$ Fe concentration (0.01$\leq$0.01 samples was fundamentally attributable to the paramagnetic phase as well as the ferromagnetic phase.e.

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.