• Title/Summary/Keyword: 0.9 V to 5 V

Search Result 2,861, Processing Time 0.037 seconds

Characteristics of the 2-D SSIMT using a CMOS Process (CMOS 공정을 이용한 2차원 SSIMT의 특성)

  • Song, Youn-Gui;Ryu, Ji-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.697-700
    • /
    • 2007
  • A novel 2-Dimensional Suppressed Sidewall Injection Magnetotransistor (SSIMT) with high linearity has been fabricated on the standard CMOS technology and experimentally verified. The novel 2-Dimensional SSIMT overcomes the restriction of the standard CMOS technology. Experimental results of the fabricated 2-Dimensional SSIMT show that the variation of each collector output currents are extremely linear as a function of magnetic field from -200mT to 200mT at $I_B = 1 mA,\;V_{CE} = 5 V\;and\;V_{SE} = 5 V$. The relative sensitivity shows up to 13 %/T. The measured nonlinearity of the fabricated device is about 0.9%.

Whole brain radiotherapy using four-field box technique with tilting baseplate for parotid gland sparing

  • Park, Jaehyeon;Yea, Ji Woon
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the efficacy and feasibility of four-field box whole brain radiotherapy (FB-WBRT) with tilting baseplate by comparing bilateral WBRT (B-WBRT). Methods and Materials: Between March 2016 and September 2018, 20 patients with brain metastases underwent WBRT using the four-field box technique. WBRT is performed with a dose of 30 Gy in 10 fractions daily. Two computed tomography simulations per person were performed. One was in the traditional supine position for B-WBRT and the other by applying the tilting acrylic supine baseplate to elevate the head by 40° for FB-WBRT. The B-WBRT used the field-in-field technique, which is the most commonly used method in our institution. The FB-WBRT comprised anterior, posterior, and bilateral beams. A wedge was applied in anterior and posterior fields to compensate for skull convexity. Results: The average of Dmean of both parotid glands was 10.2 Gy (range, 3.8 to 17.8 Gy) in B-WBRT and 5.4 Gy (range, 2.0 to 11.7 Gy) in FB-WBRT (p < 0.05). Compared to B-WBRT, FB-WBRT reduced the mean dose of the right and left parotid glands from 10.1 Gy to 4.9 Gy and from 10.4 Gy to 5.8 Gy, respectively (p < 0.05). Further, V5, V10, V15, V20, and V25 for the parotid gland decreased significantly in FB-WBRT (p < 0.05). The Dmax and Dmean of lens decreased according to the dose-volume histogram. Conclusion: Compared to B-WBRT, FB-WBRT with a tilting baseplate is a simple and effective method that takes feature of noncoplanar beam to protect the parotid gland.

Suggested and Preferred Amount of Clothing in a Winter Indoor Condition

  • Shim, Huen-Sup;Jeong, Woon-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.12
    • /
    • pp.1418-1424
    • /
    • 2011
  • This study proposes the suggested amount of clothing (SAC) and examines the preferred amount of clothing (PAC) for thermal comfort in mild cold conditions. Six male and nine female college students were systematically exposed to mild cold conditions by reducing the amount of clothing (Step I, 1.2clo ${\rightarrow}$ Step II, 1.0clo ${\rightarrow}$ Step III, 0.8clo ${\rightarrow}$ Step IV, 0.7clo). The subjects were then asked to adjust the amount of clothing to attain overall thermal comfort until they maintained thermal comfort for 10 minutes without changing the amount of clothing (Step V). The experiment was carried out in a climatic chamber at $19.5^{\circ}C$, 50%R.H. Body composition was measured and individual cold climate adaptability was surveyed before starting the experiment. Rectal temperature ($T^{re}$), skin temperature ($T_{sk}$), and oxygen consumption ($\dot{V}O_2$) were measured and the overall thermal sensation was voted in each step. PAC was obtained from the garments weight selected by each subject in Step V. SAC was proposed based on the change of oxygen consumption (${\Delta}\dot{V}O_2$). As a result, males showed higher $\bar{T}_{sk}$ and greater $O_2$ than females (p<.01). SAC obtained from $\dot{V}O_2$ were 652.0 (SE 3.9) g/$m^2$ for males and 766.0 (SE 2.5) g/$m^2$ for females and it was significantly different between groups (p<.01). PAC of males and females were 1.6 and 1.5 times heavier than SAC. In conclusion, females were more sensitive to the cold stress and recommended larger amount of clothing than males.

Growth and Optoelectrical Properties for $CuInS_2$ Single Crystal Thin Film ($CuInS_2$ 단결정 박막 성장과 광전기적 특성)

  • Hong, Kwang-Joon;Lee, Sang-Youl
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.230-233
    • /
    • 2004
  • The stochiometric mix of evaporating materials for the $CuInS_2$ single crystal thin films was prepared from horizontal furnance. Using extrapolation method of X-ray diffraction patterns for the $CuInS_2$ polycrystal, it was found tetragonal structure whose lattice constant $a_0$ and $c_0$ were $5.524\;{\AA}$ and $11.142\;{\AA}$, respectively. To obtain the single crystal thin films, $CuInS_2$ mixed crystal was deposited on throughly etched semi-insulator GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperature were 640 t and 430 t, respectively and the thickness of the single crystal thin films was $2{\mu}m$. Hall effect on this sample was measured by the method of van dot Pauw and studied on carrier density and temperature dependence of mobility. The carrier density and mobility deduced from Hall data are $9.64{\times}10^{22}/m^3,\;2.95{\times}10^{-2}\;m^2/V{\cdot}s$ at 293 K, respectively The optical energy gaps were found to be 1.53 eV at room temperature. From the photocurrent spectrum by illumination of perpendicular light on the c - axis of the thin film, we have found that the values of spin orbit coupling splitting ${\Delta}So$ and the crystal field splitting ${\Delta}Cr$ were 0.0211 eV and 0.0045 eV at 10 K, respectively. From PL peaks measured at 10K, 807.7nm (1.5350ev) mean Ex peak of the free exciton emission, also 810.3nm (1.5301eV) expresses $I_2$ peak of donor-bound exciton emission and 815.6nm (1.5201eV) emerges $I_1$ peak of acceptor-bound exciton emission. In addition, the peak observed at 862.0nm (1.4383eV) was analyzed to be PL peak due to donor-acceptor pair(DAP).

  • PDF

Study on Simulation of Runoff and Nitrogen for Application of LM3V Model in South Korea (LM3V 지면모델의 국내 적용성 평가를 위한 유출량 및 질소 모의 연구)

  • Jung, Chung Gil;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.4
    • /
    • pp.1-15
    • /
    • 2017
  • Eutrophication of surface waters is of concern worldwide, because it can result in many undesirable water-quality and ecological problems, such as hypoxic 'dead' zones and harmful algal blooms, both associated with considerable economic costs. In this study, we used LSM (Land Surface Model) to simulate nitrogen in five major rivers in the Southern Korean Peninsula. The main objective of this research was to enhance nitrogen data for input of LM3V model in South Korea. Input data for nitrogen fluxes were categorized into three sections including agriculture fertilizer, livestock manure, atmosphere deposition, biological fixation, and sewage pollutants were used as the nitrogen input. For using LM3V model, the nitrogen input data were regenerated by considering states of agriculture and industry in South Korea at a $1/8^{\circ}$ resolution. Then, we simulated stream/river flows and N loads throughout the entire drainage networks in South Korea at a $1/8^{\circ}$ resolution. By using the same parameters for the entire country ($100,210km^2$), composed of 5 river basins with varying climate and land use, the model simulates spatial (11 sites) and temporal (1999~2010) patterns of flows and nitrate-N loads are resonable by comparing observed flow and nitrate-N loads. The r (Pearson's linear correlation) for water temperature, flow and nitrate-N at river were 080~0.93, 0.62~0.92 and 0.5~0.9 respectively. Based on enhanced N input data and model results, we find that LM3V model as land surface model can be applied in South Korea with interaction of atmosphere and land conditions.

Effect of Application Rate of Dolomite in Three Media Containing Polyacrylic Acid Sodium Salt on Growth and Nutrient Contents of Potted Chrysanthemum 'Lima Honey' (Polyacrylic Acid Sodium Salt를 혼합한 세 종류 상토에 고토석회의 시비 수준이 포트멈 'Lima Honey'의 생육 및 무기원소 흡수에 미치는 영향)

  • Choi Jong-Myung;Wang Hyun-Jin;Won Mi-Kyong
    • Journal of Bio-Environment Control
    • /
    • v.15 no.1
    • /
    • pp.8-20
    • /
    • 2006
  • This research was conducted to determine the plant growth and nutrient contents of potted chrysanthemum 'Lima Honey' as influenced by application rate of dolomite in three root media, peatmoss+vermiculite (1:1, v/v), peatmoss+composted rice hall (1:1, v/v), and peatmoss+composted pine bark (1:1, v/v). All root media contained polyacrylic acid sodium salt (PASS) at a rate of $4.5g L^{-1}$. In crop growth at 40 and 80 days after transplanting, elevated application rates of dolomite up to $6.0g L^{-1}$ in three root media increased fresh and dry weights per plant. But the treatment of $9.0g L^{-1}$ had less fresh and dry weights than those of $6.0g L^{-1}$. Tissue phosphorus content decreased and those of Ca and Mg increased by the elevated application rates of dolomite. Elevated application rates of dolomite in three root media resulted in the increase of pH, EC, and the concentrations of K, Ca, and Mg at 43 days after transplanting. Those at 80 days after transplanting were also increased, but the differences among treatments were less significant as compared to those at 43 days after transplanting. From the results of dry weight in potted chrysanthemum 'Lima Honey', the proper application rate of dolomite to three root media containing PASS at a rate of $4.5g L^{-1}$ were $6.0g L^{-1}$.

The Characteristics of Creep for Two-Phase Ti-6Al-4V Alloy (Ti-6Al-4V 2상 합금의 크리프 특성(特性))

  • Park, Yong-Gwon;Choi, Jae-Ha;Wey, Myeong-Yong
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.15 no.4
    • /
    • pp.172-177
    • /
    • 2002
  • The steady-static creep behaviors of Ti-6Al-4V alloy, using the constant stress creep tester, were investigated over the temperature range of $510{\sim}550^{\circ}C$(0.42~0.44Tm) and the stress range of 200~275 MPa($20.41{\sim}28.06kg/mm^2$). The stress exponents(n) for the static creep deformation of this alloy were 9.85, 9.35, 9.24 and 8.85 at the temperature of 510, 525, 535 and $550^{\circ}C$, respectively. The stress exponent(n) decreased with increasing the temperature and became close to about 5. The apparent activation energies(Q) for the static creep deformation were 254.4, 241.8, 234.4 and 221.9 kJ/mole for the stress of 200, 225, 250 and 275MPa, respectively. The activation energy(Q) decreased with increasing the stress. From the above results, it can be concluded that the static creep deformation for Ti-6Al-4V alloy was controlled by the dislocation climb over the ranges of the experimental conditions. Larson-Miller Parameter(P) for the crept specimens of Ti-6Al-4V alloy under the static creep conditions was obtained as $P=(T+460)({\log}\;t_r+21)$. The failure plane observed by SEM showed up dimple phenomenon at all range.

Consequence of Synthetic Bone Substitute Used for Alveolar Cleft Graft Reconstruction (Preliminary Clinical Study)

  • Rawaa Y. Al-Rawee;Bashar Abdul-Ghani Tawfeeq;Ahmed Mothafar Hamodat;Zaid Salim Tawfek
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.478-487
    • /
    • 2023
  • Background The outcome of alveolar grafting with synthetic bone substitute (Osteon III) in various bone defect volumes is highlighted. Methods A prospective study was accomplished on 55 patients (6-13 years of age) with unilateral alveolar bone cleft. Osteon III, consisting of hydroxyapatite and tricalcium phosphate, is used to reconstruct the defect. Alveolus defect diameter was calculated before surgery (V1), after 3 months (V2), and finally after 6 months (V3) postsurgery. In the t-test, a significant difference and correlation between V1, V2, and V3 are stated. A p-value of 0.01 is considered a significant difference between parameters. Results The degree of cleft is divided into three categories: small (9 cases), medium (20 patients), and large (26 cases).The bone volume of the clefted site is divided into three steps: volume 1: (mean 18.1091 mm3); step 2: after 3 months, volume 2 resembles the amount of unhealed defect (mean 0.5109 mm3); and the final bone volume assessment is made after 6 months (22.5455 mm3). Both show statistically significant differences in bone volume formation. Conclusion An alloplastic bone substitute can also be used as a graft material because of its unlimited bone retrieval. Osteon III can be used to reconstruct the alveolar cleft smoothly and effectively.

Improved Charge Pump with Reduced Reverse Current

  • Gwak, Ki-Uk;Lee, Sang-Gug;Ryu, Seung-Tak
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.353-359
    • /
    • 2012
  • A highly efficient charge pump that minimizes the reverse charge sharing current (in short, reverse current) is proposed. The charge pump employs auxiliary capacitors and diode-connected MOSFET along with an early clock to drive the charge transfer switches; this new method provides better isolation between stages. As a result, the amount of reverse current is reduced greatly and the clock driver can be designed with reduced transition slope. As a proof of the concept, a 1.1V-to-9.8 V charge pump was designed in a $0.35{\mu}m$ 18 V CMOS technology. The proposed architecture shows 1.6 V ~ 3.5 V higher output voltage compared with the previously reported architecture.

Maximum Oxygen Consumption Determined by the Bruce and Inclined Treadmill Protocols

  • Kim, Kyu-Hwa;Kim, Hyeong-Jin;Kim, Kyoung-Soon
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.209-215
    • /
    • 1993
  • The aim of the present study was to derive regression equations for $\dot{V}o_{2max}\;vs.\;\dot{V}o_{2peak},\;and\;\dot{V}o_2\;vs.$ heart rate, exercise time, and other variables from maximal exercise tests on a treadmill using the Bruce and inclined protocols. Twelve male and 10 female Korean college students aged between 19 and 23 years voIunteered for this study. After the resting measurements, the subjects performed a maximal exercise on a treadmill according to the Bruce protocol. When the resting conditions were restored, the subjects performed another maximal exercise according to an inclined protocol where the speed was fixed at 8.05 $km{\cdot}h^{-1}$ and the grade was incremented starting from 09t by 2.5% for every 2 min. Peak $\dot{V}o_2$ observed during the Bruce exercise $(\dot{V}o_{2peak})$ was $37.7{\pm}2.4\;and\;31.7{\pm}1.8\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Peak $\dot{V}o_2$ observed during the inclined exercise was higher than $\dot{V}o_{2peak}$ during the Bruce exercise. Maximum $\dot{V}o_2$ value observed during the tyro exercises $(\dot{V}o_{2max})$ was $43.0{\pm}2.8\;and\;36.2{\pm}1.4\;ml\;kg^{-1}\;min^{-1}$ in the male and female groups, respectively. Thus, $\dot{V}o_{2peak}$ by the Bruce protocol was about 12% (male) or 13% (female) lower than $\dot{V}o_{2max}$, and a linear relationship was found between $\dot{V}o_{2peak}$ and $\dot{V}o_{2max}$. The peak values of % $\dot{V}o_{max}$ with the Bruce protocol were $89.2{\pm}3.3\;and\;87.5{\pm}3.6%$ and those with the inclined protocol $97.7{\pm}1.8\;and\;96.9{\pm}2.0%$ in the male and female groups, respectively. In the female group, $%\dot{V}o_{2max}$ at a given workload was higher than in the male group, while $\dot{V}o_{2}$ per kg body weight was the same. Maximum HR observed during the two exercises was $204{\pm}2\;and\;195{\pm}3\;beat\;min^{-1}$ in the male and female groups, respectively. Linear relationships were found, excluding the last points, between 1) $\dot{V}o_{2}$ and exercise time, 2) $\dot{V}o_{2}$ and $%\dot{V}o_{2max}\;and\;%HR_{max}$.

  • PDF