• Title/Summary/Keyword: . transformer

Search Result 4,329, Processing Time 0.038 seconds

A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires (전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구)

  • Hwang, Jin-Kwon
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2009
  • Several electrical loads such as inrush current, normal operation arcing and non-sinusoidal loads have normal current waveforms similar to arc waveforms. To detect arcs in such loads, therefore, it is necessary to analyze difference between current waveforms with or without arcs. In this paper, using apparatuses of arc generation in UL 1699, arcs are generated in these loads and, then, arc current waveforms are investigated in both the time and the frequency domains to find arc characteristics. This investigation shows that arc current signals have shoulders at some zero current points in the time domain and increment of spectrum magnitude in all over frequency domain. It also shows that the arc characteristics at normal operation arcing and non-sinusoidal loads are detected more easily in the frequency domain than in the time domain. This investigated arc characteristics are expected to be utilized as the basis of development of arc-fault circuit interrupters.

Voltage Control of Power System Connected to a Wind Farm by Using STATCOM and Reactive Power Compensators (STATCOM과 조상설비를 이용한 풍력단지가 연계된 전력계통의 전압제어)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2737-2743
    • /
    • 2015
  • The wind power plant must be able to produce reactive power at the POI bus of a wind farm connected to power system to keep or control the voltage of POI bus. But, the reactive power capability of wind turbines may not be sufficient to control the voltage of POI bus due to the reactive power losses in connection lines between wind farm and POI bus. The solution of this problem is to install an external STATCOM. The proposed cooperative control method of STATCOM and conventional reactive power compensators such as Switched-shunt and tap changing transformer can control the voltage of POI bus more efficiently. The simulation results are shown that the voltage drop of POI Bus of Test System with the arbitrary load change rate to initial loads is improved more than 60% and the voltage of load bus is maintained more than 95% of rated voltage.

A Design Method for Dynamic Selection of SOA Services (SOA 서비스의 동적 선택 설계 기법)

  • Bae, Jeong-Seop;La, Hyun-Jung;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.2
    • /
    • pp.91-104
    • /
    • 2008
  • Service-Oriented Computing (SOC) is the development method that published services are selected and composed at runtime to deliver the expected functionality to service clients. SOC should get maximum benefits not only supporting business agility but also reducing the development time. Services are selected and composed at runtime to improve the benefits. However, current programming language, SOC platforms, business process modeling language, and tools support either manual selection or static binding of published services. There is a limitation on reconfiguring and redeploying the business process to deliver the expected services to each client. Therefore, dynamic selection is needed for composing appropriate services to service clients in a quick and flexible manner. In this paper, we propose Dynamic Selection Handler (DSH) on ESB. we present a design method of Dynamic Selection Handler which consists of four components; Invocation Listener, Service Selector, Service Binder and Interface Transformer. We apply appropriate design patterns for each component to maximize reusability of components. Finally, we describe a case study that shows the feasibility of DSH on ESB.

A Study on characteristics of the forward type high frequency pulse power supply for lamp type ozonizer (램프형 오존발생기용 Forward type 고주파 펄스 전원장치의 특성에 관한 연구)

  • 김경식;김동희;이광식;원재선;송현직
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.89-96
    • /
    • 2000
  • This paper describes the forward type pulse power supply which is the simple circuit configuration and easy to be managed using a power semiconductor switching device(Power-MOSFET) in the view of commercialization. The maximum value of output pulse voltage of the proposed pulse power supply system can be realized by the variation of phase angle($\phi$) of bridge rectifier circuit and also its pulse period is determined by the duty ratio of Power-MOSFET. The principle of basic operating and the operating characteristics of the forward type pulse power supply are estimated by the switching frequency, the variation of phase angle($\phi$)It is shown that theoretical and experimental results are in good agreement by comparing simulation and experimental results of proposed pulse power supply when a lamp type ozonizer can be used as a load. This proposed pulse power system shows that it can be practically used in the future as a power source system in various fields.

  • PDF

An Analysis and Optimum Design of o Neutral Line Harmonics Eliminating Reactor (중성선 영상고조파 저감용 특수 Reactor 최적설계 연구)

  • Shin, Pan-Seok;Chung, Gyo-Bum;Kim, Han-Deul;Kim, Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.33-41
    • /
    • 2006
  • In the modem power distribution systems, there are lots of zero-phase current harmonics in the neutral power line due to much usages of the controlled switching devices, various semiconductor power converting systems, OA(Office Automation) equipments, PC etc. In order to minimize the current harmonics a zero-phase neutral line current eliminating reactor (NHER) is designed and analyzed its performance using the finite element program. For the design of NHER a program is developed using C++ program. To verify the program a case model(380/220[V], 200[A]) is designed and analyzed by the developed program. As the results of the optimal design, the core loss is reduced by 26[%] with eliminating of the current harmonics. Especially the ninth harmonics is much reduced as compared with the others. When the design of NHER is adapted to the load of the power system, the eliminating effect and efficiency of the device will be much better

Verification on the Calculated Geoelectric Field on Power Grid during Geomagnetic Disturbances (지자기 교란으로 인한 전력망 유도전기장 예상값 검증)

  • Park, Sung Won;Yoo, Chung-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.94-100
    • /
    • 2015
  • Coronal mass ejection (CME) released due to solar flare explosion cause geomagnetic disturbance. The induced current by massive geomagnetic disturbance can cause damage to the transformer. The calculated geoelectric field is a major parameter of the geomagnetically induced current (GIC). The method applying a Fourier transform has a high accuracy but it needs all data measured for 24 hours. And the other method applying a integral equation can calculate in real time but it requires to check an accuracy. To reduce the gap between the calculated results of two methods, it adjusts the integration section. As a result, the correlation between two calculated geoelectric fields is high, and the event time and direction of the calculated current is the same as that of the measured current, and it's accuracy rate is above 92 percent.

The Piezoelectric Properties of (Na0.5K0.5)NbO3-K5.4Cu1.3Ta10O29 Ceramics with Various K5.4Cu1.3Ta10O29 Doping and Sintering Temperatures

  • Yoon, Jung Rag;Lee, Chang-Bae;Lee, Serk Won;Lee, Heun-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.6
    • /
    • pp.283-286
    • /
    • 2012
  • (1-X)$(Na_{0.5}K_{0.5})NbO_3-XK_{5.4}Cu_{1.3}Ta_{10}O_{29}$ (NKN-KCT) lead-free piezoelectric ceramics have been synthesized by the conventional solid state sintering method, and their sinterability and piezoelectric properties were investigated. Typically, this material is sintered between 1,025 and $1,100^{\circ}C$ for 2 hours to achieve the required densification. Crystalline structures and Microstructures were analyzed by X-ray diffraction and scanning electron microscope. The density, dielectric constant (${\varepsilon}_r$), piezoelectric constant $d_{33}$, electromechanical coupling factor $k_p$ and mechanical quality factor $Q_m$ value of the NKN ceramics depended upon the KCT content and the sintering temperature. In particular, the KCT addition to NKN greatly improved the mechanical quality factor $Q_m$ value. The ceramic with X = 1.0 mol% sintered at $1,050^{\circ}C$ exhibited optimum properties (${\varepsilon}_r$=246, $d_{33}$=95, $k_p$=0.38 and $Q_m$=1,826). These results indicate that the ceramic is a promising candidate material for applications in lead free piezoelectric transformer and filter materials.

A Study on the Stability of the Accelerating Voltages in Scanning Electron Microscopy (주사전자현미경에서 가속전압의 안정성 연구)

  • Bae, Moon-Seob;Oh, Sang-Ho;Cho, Yang-Koo;Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.51-59
    • /
    • 2004
  • The high acceleration voltage system used in scanning electron microscope were designed and manufactured to test its stability. The Cockcroft-Walton circuits are used both in the cathode voltage up to -30 kV and in the Wehnelt cylinder of -2 kV. The operating voltage of 6 V was applied to the heating of the filament. The wave forms which are formed in the second leg of the high voltage transformer were observed in the oscilloscope with 2 V of DC input. When the high voltages were in the range between 5 kV and 12 kV, the highest value of the stabilities of the generated voltages was obtained as 0.002%.

Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump (제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석)

  • Yoon, Jun Seong;Kwon, Oh Kyung;Cha, Dong An;Bae, Kyung Jin;Kim, In Gwan;Kim, Min Soo;Park, Chan Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

A Study on Fault Location Estimation Technique Using the distribution Ratio of Catenary Current in AC Feeding System (전차선 전류 분류비를 이용한 교류전기철도 고장점 표정기법에 관한 연구)

  • Jung, Ho-Sung;Park, Young;Kim, Hyeng-Chul;Min, Myung-Hwan;Shin, Myong-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.5
    • /
    • pp.404-410
    • /
    • 2011
  • In AC feeding system, the fault location is calculated by using ratio of current absorbed in the neutral point of AT(Automatic Transformer) or by measuring reactance. In this way, however, an estimation error can be happened due to the many reasons. In addition, for measuring currents in the neutral point of AT, other measuring devices and communication equipments are additionally required. In order to solve the disadvantages, this paper suggests a novel technique using the distribution ratio of catenary current. The proposed technique uses existing protective relays and measures catenary current. With the measured data, we can calculate the distribution ratio of catenary current and determine fault location. Through the simulated results, we derived the correlation between current ratio and fault location. Using this technique, additional equipments and expenses can be reduced. Besides, fault location can be determined more correctly.