• Title/Summary/Keyword: . transformer

Search Result 4,335, Processing Time 0.036 seconds

Influence of a Neutral Line on the Quench Behaviors of a Transformer Type SFCL (변압기형 초전도 한류기의 퀜치특성에 대한 중성선의 영향)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Koo, Kyung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2212-2213
    • /
    • 2008
  • In this paper, we studied the method for simultaneous quenching of a transformer type superconducting fault current limiter (SFCL) with two superconducting elements connected in series. Only an element between two elements of the transformer type SFCL was quenched like the case of the resistive type SFCL. By this quenching characteristics, the power burden of the superconducting element was increased. In order to solve this problem, we connected the neutral line between two superconducting elements and the center of secondary coils. The two elements were all quenched in the transformer type SFCL with a neutral line. As a result, the power burden of superconducting elements was decreased, so it was efficient for the increase of power capacity of the transformer type SFCL.

  • PDF

Study on Aging Characteristics and Chemical Composition of Hydrogenated Transformer Oil

  • Qian, Yi-Hua;Huang, Yi-Bin;Fu, Qiang;Zhong, Zhen-Sheng
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.588-594
    • /
    • 2013
  • Under the condition of Baader aging, the chemical composition variation and the influence of transformer oil aging on electrical properties such as dielectric loss factor and physic-chemical properties such as interfacial tension were studied in the aging precess. Moreover, the correlation between hydrogenated transformer oil electrical and physic-chemical properties and its chemical composition variation were also investigated. The results show that these parameters of physic-chemical and electrical properties of hydrogenated transformer oil relate to each other and have closed correlation with chemical composition.

Highly miniaturized and low impedance RFIC/MMIC impedance transformer for application to the wireless communication components in Vessel (선박 무선통신 소자에의 응용을 위한 초소형 저임피던스 RFIC/MMIC용 임피던스 변환기의 설계)

  • Lee, Kyung-Sik;Yun, Young
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.417-422
    • /
    • 2005
  • Using the novel microstripline with periodically perforated ground metal, a miniaturized 1/4 ${\lambda}$ transformer was fabricated. The line width of the 1/4 ${\lambda}$ transformer was 20${\mu}m$ and the size of it was 0.0085$mm^2$, which is 1.2% of conventional one. The 1/4 ${\lambda}$ transformer exhibited good RF performances from 10 to 25GHz.

  • PDF

A Study on the Driven and Analysis of T5 Application Circuits using a Characteristics of Piezoelectric Transformer (압전 변압기 특성을 이용한 T5급 응용회로 동작 및 해석에 관한 연구)

  • Lee, Hae-Chun;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.113-118
    • /
    • 2010
  • In This Paper, at the PSPICE model is presented by Piezoelectric Transformer and CCFL and equivalent circuit of fluorescent light. Highly effective fluorescent light release for next generation is developed for 35W supremacy model three wave length T5 fluorescent lamps. Lighting a candle experiment of T5 fluorescent lamps is carried out by employing Piezoelectric Transformer power-factor improvement circuit and inverter. PLL method is used for supplying a correct frequency of Piezoelectric Transformer operating.

A Study on the Characteristics of Circular Piezoelectric Transformer which has Crescent-Shaped Input Electrode (Crescent-Shaped Input Type 원형압전변압기의 특성)

  • Jeong, Seong-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.234-235
    • /
    • 2005
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. The piezoelectric transformers operated in each transformer's resonance vibration mode. The electrodes and poling directions on commercially available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor ($k_p,\;k_{15}$) becomes effective rather than the transverse mode coupling factor ($k_{31}$).

  • PDF

Gas detection charracteristic of Transformer Oil Gas Detector (변압기 절연유중 가스 검출장치의 가스 감지 특성)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Lee, Suck-Woo;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.323-324
    • /
    • 2005
  • To found out the degradation characteristic of transformer insulation, insulation materials and electrodes are deposited into transformer oil. They used to heated and make flashover. Due to the thermal and electrical stress added to insulation materials, the density of carbon dioxide and hydrogen included in transformer oil was increased. The gas density can measured by using the gas density detection equipment of gas sensor and air circulation method.

  • PDF

Design and Analysis of the 300 W Planar Transformer (300 W급 평면 변압기의 설계 및 분석)

  • ;;;;;Ustinov Evgeniy
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.502-507
    • /
    • 2004
  • The forward planar transformer, which had power capacity of 300 W, input voltage of 220 V, output voltage of 15 V, and switching frequency of 300 KHz, was designed and manufactured by using the planar core with large effective area and the flat copper leadframes for miniaturization and high efficiency of the switching mode power supply (SMPS). As well as, a forward converter equipped with the above mentioned planar transformer was manufactured and electromagnetic characteristics were investigated. The numerical value of turns for 1st and 2nd winding were 15 and 2 respectively The self inductance of 1st winding was 1.592 mH, very low leakage inductance of 2.7 $\mu$H, and the coupling factor of 0.928 were obtained at switching frequency of 300 KHz. The high efficiency of 88.62 % for the SMPS equipped with planar transformer was obtained at power capacity of 300 W.

The Relationship between Wind Power Generation Grid-connected Transformer Winding Connection and Fault Current in MATLAB & SIMULINK (MATLAB & SIMULINK에서 풍력발전 계통연계 변압기결선과 고장전류와의 관계)

  • An, Hae-Joon;Kim, Hyun-Goo;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.307-309
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

Diagnosis for the Transformer depend on Moisture and Furfural Detecting in Oil (절열유중의 수분 및 Furfural 검출을 이용한 유입변압기 상태진단)

  • Choi Gwang-beom;Eo Soo-young;Kweon Dong-jin;Lee Dong-joon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.546-552
    • /
    • 2005
  • In this paper, a present condition with gas-in-oil diagnosis which used to condition analysis for oil insulated transformer is investigated and reason why hydrogen used to basic diagnosis for the transformer is described. This paper gives an overview of background knowledge that should to consider as moisture detecting of oil immersed paper and how could we approach to life expectancy of oil insulated transformer through detecting furfural compound.

A Study of Insulation Design of a Gas Transformer Using Extra Turns.) (여유턴 방식에 의한 가스변압기의 절연 설계에 관한 연구)

  • Heo, Woo-Heng;Ha, Young-Sik;Hong, Jung-Pyo;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.3
    • /
    • pp.115-121
    • /
    • 2001
  • This paper deals with the electrical insulation design of a gas insulated power transformer based on extra turns method satisfying the impulse test performed in the worst condition. The calculation of electrical strength in insulation structure was done by 2D finite element method. The gas insulated power transformer was manufactured by selecting the optimum arrangement among design results. the validity of the design result is verified by the impulse test of manufactured machine.

  • PDF