• Title/Summary/Keyword: . transformer

Search Result 4,329, Processing Time 0.029 seconds

A Study on the Development of Low-loss Type Hybrid Insulation Pole Transformers and (저손실형 복합절연 주상변압기 개발 및 단락특성에 관한 연구)

  • Min, Yun-Hong;You, Ho-Keun;Bae, Sun-Ki;Kim, Ho-Chul;Lee, Yun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.607-612
    • /
    • 2002
  • This paper presents the first domestic model product of hybrid Insulation low-loss type pole transformer, with increased overload ability, increased life, reduced loss, focusing improved short-circuit characteristics. The capacity of this transformer is 100 KVZ, rates first voltage 13200 V and secondary voltage 230/115 type. The volume of model transformer that was produced in high temperature using hybrid insulation can be reduced to 10-20% in comparison with that of present transformer with the same capacity. In this paper, we did short-circuit test and tested general characteristics of model transformer. In addition, we suggested design application new concept and methods thorough this experiment.

  • PDF

Vibration Characteristic Analysis of the Main Transformer for KTX (KTX 주변압기의 진동특성 분석)

  • Kim, Jin-Woo;Yang, Jae-Cheol;Heo, Min-Woong;Kim, Dae-Sik;Kim, Ho-Soon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.649-655
    • /
    • 2011
  • In this paper, the content to carry out the modal testing and to analyze the data as the target of the main transformer installed on KTX is mentioned. The main transformer for KTX is a structure which is over 10 Ton. For the possibility to occur a stress concentration phenomenon exists, the dynamic durability of the system is experimentally needed to understand. To do this, we obtained the vibration data using an accelerometer, an impact hammer, a measuring instrument and gained the frequency response function of the main transformer based on the acquisition data. In this content, when the theoretical model for structural analysis should be established, we think it will be used for the property verification of analytical model. Also, we expect that the measured and analysed data will offer basic research material to maintain the system and diagnose the condition by monitoring the natural frequency of the main transformer for KTX periodically.

  • PDF

Optimal Design of High Frequency Transformer for 150W Class Module-Integrated Converter

  • Yoo, Jin-Hyung;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.288-294
    • /
    • 2015
  • Recently, the module-integrated converter has shown an interest in the photovoltaic generation system. In this system, the high frequency transformer should be compact and efficient. The proposed method is based on the correlation characteristic between the copper and core loss to minimize the loss of transformer. By sizing an effective cross-sectional area and window area of core, the amount of loss is minimized. This paper presents the design and analysis of high frequency transformer by using the 3D finite element model coupled with DC-DC converter circuit for more accurate analysis by considering the nonlinear voltage and current waveforms in converter circuit. The current waveform in each winding is realized by using the ideal DC voltage source and switching component. And, the thermal analysis is performed to satisfy the electrical and thermal design criteria.

Optimal Design of a Transformer Core Using DEAS (DEAS를 이용한 변압기 코아의 최적설계)

  • Kim, Tae-Gyu;Kim, Jong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1055-1063
    • /
    • 2007
  • This paper introduces an optimal design technique for a 250-watt isolation transformer using an optimization method, dynamic encoding algorithm for searches (DEAS). Although the optimal design technique for transformers dates back to 1970s and various optimization methods have been developed so far, literature concerning global optimization for transformer core design is rarely found against its importance. In this paper, core configuration of the isolation transformer whose performance is computed by complex mathematical steps is optimized with DEAS. The optimization result confirms that DEAS can be successfully employed to transformer core design for various performance specifications only by adjusting weight factors in cost function.

Effect of Harmonics on the Cast-Resin Transformer Life Cycle (고조파가 몰드변압기 수명에 미치는 영향분석)

  • Kang, Chang-Seob;Lee, Hong-Gee;Lee, Un-Cheol;Yoon, Duck-Ryang
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.118-120
    • /
    • 1996
  • We've been reported recently that increase of installing big power converting equipment which makes harmonics result in damage on transformer for incoming and load. Specially, harmonics that cause overheat and aging is severer in cast-resin transformer a kind of dr type than in oil one. The goal of this paper is to prove the process for aging of transformer that result from harmonics in according to both of theory and actual measurement on site. And we introduce diagnostic methods to estimate aging condition of cast-resin transformer in accordance with simulation.

  • PDF

A study on the development of LVI tester and applying the winding deformation of transformers with this tester (LVI 시험기의 개발과 변압기 권선변형 분석의 적용에 관한 연구)

  • 조국희;김광화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.58-64
    • /
    • 2001
  • This paper is described about design and manufacture of the LVI tester and the model transformer. And we develope the analysis technology of the LVI test with using the developed LVI tester and the model transformer. The LVI tester is consisted of a main body, terminal boxes and cables. It is estimated that the tester has output characteristic to match ANSI specification. The winding deformation models are made of model transformer having tapes and we discuss about the analysis technology of LVI test using the tester and the model transformer.

  • PDF

Diagnosis and Evaluation of the Real Time Transformer by the Infrared Thermal Image Equipment (적외선 열화상 장비를 이용한 실시간 변압기 진단 및 평가)

  • Lee, Chul-Ku;Baek, Won-Gab;Kim, Sung-Dai
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.666-671
    • /
    • 2012
  • It was diagnosed customer transformers and other equipment by using non-contact infrared equipment. Examiners can identify not only abnormalities in real time in the field of the transformer immediately, as well as they were able to safely perform the scan. Thanks to successful transformer diagnosis, we can easily diagnose abnormalities of transformer itself which can be caused by deterioration of the oil used as overlaod or refrigerant and we can also diagnose abnomalities from low voltage bushing which can be result by external environmental factors and physical factors and abnomalities from its connections at the same time we found it is very useful at proactive diagnostics.

$SF_6$ Gas Insulated Transformer ($SF_6$가스절연 변압기)

  • Cho, G.J.;Cho, K.D.;Ha, Y.S.;Cho, K.B.;Noh, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.304-309
    • /
    • 1991
  • We introduce the trend, of several countries, to the gas insulated transformer recently coming into the spot light by the advantages of less weight, GIS-lization, low noise level and easiness to decrease environmental pollutions, and the insulating gases. the cooling media and the insulating materials used for transformer. Hereinafter, additively the design of proto type $SF_6$ gas insulated transformer (insulation, cooling), which was developed by us(HICO) from 1987. 2 through 1990. 3, the manufacturing processes(leak protection, pressure, drying of main body), the accessories, the protective system, the cooling system, the method and the results of test and the evaluation of economics compared with conventional oil-filled transformer are represented.

  • PDF

Low Voltage Impulse Test for Power Electric Instrunment Precaution Diagonsis Techniques (전력기기 예방진단 기술을 위한 저전압 충격시험)

  • Kwak, Hee-Ro;Kim, Jae-Chul;Kwan, Tae-Won;Yoon, Young-Beum;Son, Jin-Geun;Yun, Ji-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.281-285
    • /
    • 1991
  • In this paper, response characteristics by applying impulse into transformer windings in order to precaution diagonosis of power electric instrument are studied. A sample oilless transformer, an aging transformer and a good transformer are slected for models. The experimented results show that for testing the windings distortion and impedanced change of transformer the LVI method are suitable. Also, variation characteristic of output waveforms at time and frequency domain in order to efficient analysis is discussed. The results response that waveforms at frequency domain is very higher resolution at time domain.

  • PDF

Estimating the Effect of Overvoltage Results from Excitation Current Chopping in Short-circuit Transformer (여자전류 재단에 따른 단락 시험용 변압기의 절연영향 평가)

  • Oh, Seung-Ryle;Park, Ji-Hun;Park, Jong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.78-80
    • /
    • 2007
  • The residual flux in transformer's iron cores leads to a distortion of short-circuit current occasionally. And some considerable distortion may have effect on the validation of the test results. To avoid the substantial distortion, a suitable pretest is performed before the actual test. In case of applying this method there must be excessive overvoltage due to switching of an unloaded transformer and chopping of an excitation current. The purpose of this paper is estimate that the effect of the overvoltage results from this phenomenon on insulation performance of short-circuit transformer.

  • PDF