Vibration Characteristic Analysis of the Main Transformer for KTX

KTX 주변압기의 진동특성 분석

  • 김진우 (한국철도공사 연구원 기술연구처) ;
  • 양재철 (현대중공업(주) 전기전자시스템사업본부 변압기 개발부) ;
  • 허민웅 (현대중공업(주) 전기전자시스템사업본부 변압기 설계부) ;
  • 김대식 (한국철도공사 연구원 기술연구처) ;
  • 김호순 (한국철도공사 연구원 기술연구처)
  • Published : 2011.10.20

Abstract

In this paper, the content to carry out the modal testing and to analyze the data as the target of the main transformer installed on KTX is mentioned. The main transformer for KTX is a structure which is over 10 Ton. For the possibility to occur a stress concentration phenomenon exists, the dynamic durability of the system is experimentally needed to understand. To do this, we obtained the vibration data using an accelerometer, an impact hammer, a measuring instrument and gained the frequency response function of the main transformer based on the acquisition data. In this content, when the theoretical model for structural analysis should be established, we think it will be used for the property verification of analytical model. Also, we expect that the measured and analysed data will offer basic research material to maintain the system and diagnose the condition by monitoring the natural frequency of the main transformer for KTX periodically.

Keywords