• 제목/요약/키워드: . transformer

검색결과 4,311건 처리시간 0.028초

변압기 권선공정에서의 수주 제작품의 단위공정 일정관리 시스템 개발과 다중회귀분석을 이용한 계획 리드타임 산출 및 관리 방안 (Unit Process Scheduling System Development and Calculation and Control Method of Planned Leadtime Using Multiple Linear Regression under Make to Order Manufacturing System in Transformer Winding Process)

  • 강대완;강창욱;강해운
    • 산업경영시스템학회지
    • /
    • 제31권3호
    • /
    • pp.117-124
    • /
    • 2008
  • Ultra-high voltage transformer industry has characteristic of small quantity batch production system by other order processing unlike general mass production systems. In this industry, observance of time deadline is very important in market competitive power security and company continued existence. The transformer winding is a process that rolls a coil is coated with an electric insulation material in order to generate the required voltage using the voltage fluctuation. The winding process is very important production process in the extra-high voltage transformer manufacturing industry because winding process is core process that occupy weight about half of whole process and is process that decide current ratio of transformer. This paper proposes a statistical calculation and control method of planned leadtime on the basis of real data and informations for the A company in transformer winding process. Moreover, we develop unit process scheduling system.

Flat Transformer를 적용한 고밀도 전원장치 설계 (Design of the High Density Power Supply with Flat Transformer)

  • 백주원;김종현;유동욱;김종수;류명효
    • 전력전자학회논문지
    • /
    • 제10권3호
    • /
    • pp.248-256
    • /
    • 2005
  • 본 논문에서는 중$\cdot$대용량 고밀도 전원 장치에 적합한 플랫 트랜스포머(Flat Transformer)를 사용하여 다양한 출력의 DC/DC 변환장치를 설계하는 방법을 제시하였다. 플랫 트랜스포머 모듈은 다수의 트랜스포머를 병렬로 구성하여 제작하고, 이차 권선이 항상 1턴으로 구성되므로 기존의 트랜스포머에 비해 누설 인덕턴스가 크게 감소하게 되어 고주파 스위칭에 적합한 형태를 가지고 있다. 본 논문에서는 플랫 트랜스포머의 성능을 증명하기 위하여 750W급 AC/DC 변환기를 구성하여 다양한 출력을 갖는 전원 장치를 제작/실험하였다.

하나의 코아로 집적화된 PFC 인덕터와 LLC 공진변압기 적용 AC-DC 컨버터 (AC-DC Converter using the PFC Inductor and LLC Resonant Transformer with an Integrated Magnetic Core)

  • 노영재;강철하;메아스사란;김은수;원종섭;김동희;이영수
    • 전력전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.262-272
    • /
    • 2015
  • An integrated two-in-one transformer applicable to PSUs for a 120 W LED TV is proposed. This transformer comprises a PFC inductor and an LLC transformer placed and integrated on an E-I-E type magnetic core. Performance is evaluated by observing the coupling coefficients of the proposed two-in-one transformer under various air gap topologies. Among the topologies studied, an integrated transformer with centered air gap shows stable operational characteristics with a minimized mutual coupling (interference). Furthermore, applicability of the proposed integrated transformer to PSUs for a 120 W LED TV is studied from the viewpoint of integrating different magnetic components into one core, resulting to low weight, low cost, and high power density.

새로운 양방향 지능형 반도체 변압기의 동작과 성능 분석 (Operation and Performance Analysis of New Bidirectional Intelligent Semiconductor Transformer)

  • 김도현;이병권;한병문;이준영;최남섭
    • 전력전자학회논문지
    • /
    • 제18권2호
    • /
    • pp.169-177
    • /
    • 2013
  • This paper proposes a new configuration of bidirectional intelligent semiconductor transformer with rating of 1.9kV/127V, 2kVA. The proposed transformer consists of high-voltage high-frequency AC-DC rectifier, and low-voltage DC-DC and DC-AC converters. The operational feasibility of proposed transformer was verified by computer simulation with PSCAD/EMTDC software. Based on the simulation results, a hardware prototype with rating of 1.9kV/127V, 2kVA was built and tested in the lab to confirm the feasibility of hardware implementation. Using three units of this transformer, a 3-phase transformer with rating of 3.3kV/220V, 6kVA can be built.

일체형 주상용 몰드 변압기의 온도분포 및 특성 비교 (Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding)

  • 조한구;이운용;강택수;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

3상 10kVA 더블 팬케익 코일형 고온초전도 변압기 특성시험 결과 (Test Results of a Three Phase 10㎸A HTS Transformer With Double Pan Cake Coils)

  • 이승욱;이희준;차귀수;이지광;최경달;류경우;한송엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.101-106
    • /
    • 2003
  • The high temperature superconductor transformers gain interests from the industries. This paper described construction and test results of 10㎸A HTS transformer Three phase transformer with double pancake windings were constructed. To reduce the leakage magnetic field, secondary coil were placed between the two primary coils. BSCCO-2223 wire. silicon sheet steel core and FRP cryostats were used to construct the transformer. Three coils were stacked in one cryostat. Two double pancake coils were connected in series for the primary coil and one double pancake coil was used for the secondary coil. Total number of turns of the primary winding and the secondary winding were 112turns and 98urns, respectively, The rated voltages of each winding were 440/220V. The rated currents of each winding were 13.1/26.2A. After the tests of basic properties of the three phase HTS transformer using no-load test, short-circuit test and full-load test, continuous operation of 100 hours with pure resistive load has been carried out. Test results proved over-load capability and reliability of the HTS transformer.

Effect of the Addition of Benzotriazole on the Streaming Electrification Properties in Transformer Oil

  • Shin, Jong-Yeol;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권6호
    • /
    • pp.288-291
    • /
    • 2010
  • Accidents can occur as a result of streaming electrification when transformer oil is used as an insulating oil in large ultra-high voltage transformers. Methods for adding a streaming electrification inhibitor to reduce the streaming electrification has been studied extensively. In this paper, in order to develop a method for reducing streaming electrification effectively, 4 different specimens were prepared by the addition of benzotriazole (BTA) to a virgin specimen with constant stirring. The specimens were examined to determine the appropriate amount of BTA addition that would suppress the streaming electrification most effectively. The results showed that the streaming electrification characteristics of the specimen in the streaming transformer oil were best when the amount of BTA addition was about 10 ppm. The streaming electrification current was reduced by adding 30 ppm BTA until the temperature reached $65^{\circ}C$. The polarity of the streaming electrification current was negative when the temperature exceeded $65^{\circ}C$. Therefore, the streaming electrification current, which can be a cause of transformer accidents, can be suppressed in large ultra high voltage transformer oil. This paper reports on the optimal amount of BTA addition and the best conditions for controlling the streaming velocity of transformer oil.

The Neural-Fuzzy Control of a Transformer Cooling System

  • Lee, Jong-Yong;Lee, Chul
    • International Journal of Advanced Culture Technology
    • /
    • 제4권2호
    • /
    • pp.47-56
    • /
    • 2016
  • In transformer cooling systems, oil temperature is controlled through the use of a blower and oil pump. For this paper, set-point algorithms, a reset algorithm and control algorithms of the cooling system were developed by neural networks and fuzzy logics. The oil inlet temperature was set by a $2{\times}2{\times}1$ neural network, and the oil temperature difference was set by a $2{\times}3{\times}1$ neural network. Inputs used for these neural networks were the transformer operating ratio and the air inlet temperature. The inlet set temperature was reset by a fuzzy logic based on the transformer operating ratio and the oil outlet temperature. A blower was used to control the inlet oil temperature while the oil pump was used to control the oil temperature difference by fuzzy logics. In order to analysis the performance of these algorithms, the initial start-up test and the step change test were performed by using the dynamic model of a transformer cooling system. Test results showed that algorithms developed for this study were effective in controlling the oil temperature of a transformer cooling system.

변압기(變壓器) 절연유(絶緣油) 열화(劣化)센서의 특성연구(特性硏究) (A study on the characteristics of degradation sensor for transformer insulation oil)

  • 전영갑;선종호;강동식;김문덕;권동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1765-1768
    • /
    • 1996
  • It is well known that the degradation transformer oil is mainly effected to the failure of transformer. In this paper it is discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor composed with base ring, electrodes and porous ceramic passed through the transformer oil and checked the transformer oil condition with sensor's leakage current. It is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts it is examined the characteristics of V-T-I and DC 2 KV and other examinations. It is verified that ionized transformer caused by the expansion of oil temperature increase in the leakage current of porous ceramic sensor. It is certificated that the leakage current of other parts of porous ceramic is very small (about 2 %) than the porous ceramic and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

압전변압기를 이용한 LCD Backlight 구동 (LCD Backlight Drive Using The Piezoelectric Transformer)

  • 임성운;최연호;원철호;구본호;김이국
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.28-33
    • /
    • 2003
  • 기계적인 에너지를 전기적인 에너지로 변환시키는 장치인 압전변압기는 고전압\ulcorner고효율의 소형변압기이다. 압전변압기는 노트북용 LCD backlight 구동장치로 적합하며, 공진주파수에서 동작시 거의 정현파에 가까운 교류파형을 출력하는 장치이다. 본 논문에서는 입력 DC 전압으로부터 FET를 구동시키는 게이트 신호로 변환시킨 다음 LC공진을 통하여 정현파를 생성시켜 압전변압기를 구동시키는 인버터에 대하여 논의하였다. 실험결과 압전변압기의 전압 이득과 공진주파수는 부하에 비례하며, 전압 이득은 입력전압의 변화에는 무관하게 나타났다.