• Title/Summary/Keyword: . transformer

Search Result 4,311, Processing Time 0.031 seconds

Wideband Impedance Transformer Using a Coaxial Cable (동축선을 이용한 광대역 임피던스 트랜스포머)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.789-794
    • /
    • 2011
  • A coaxial-cable impedance transformer used in wideband frequency range is generally restricted to the fixed impedance transformation ratio as n2:1 or 1:n2(n: the number of coaxial cables). In this paper, we propose a new coaxial-cable impedance transformer to have an arbitrary impedance transformation ratio. We have fabricated three impedance transformers($50-{\Omega}$ to $25-{\Omega}$, $50-{\Omega}$ to $20-{\Omega}$ and $50-{\Omega}$ to $9-{\Omega}$) to confirm the operation characteristic of the suggested impedance transformer. The reflection characteristics (S11) of the fabricated $50-{\Omega}$ to $25-{\Omega}$ and $50-{\Omega}$ to $20-{\Omega}$ impedance transformer were less than -15dB over about 3-octaves frequency range and the reflection characteristic (S11) of the fabricated $50-{\Omega}$ to $9-{\Omega}$ impedance transformer was less than -15dB over about 1-octave frequency range, respectively.

Comparison of Reciprocal and Concentric Winding Arrangement of HTS Transformer (고온초전도 변압기의 교호 배치 권선과 동심형 배치 권선의 비교)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Lee, Sang-Jin;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-yop;Park, Chan-Bae
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.61-64
    • /
    • 2003
  • In HTS transformer with double pancake windings, the perpendicular component of leakage magnetic flux density ($B_{r}$ ) applied to HTS tapes of double pancake windings of HTS transformer acts as a cause to decrease the critical current in HTS tape. So, in this paper, HTS transformer with reciprocal arrangement winding is designed. And in order to investigate the$ B_{r}$ applied to HTS windings, the 2-D non-linear electromagnetic analysis of HTS transformer is performed by using the OPERA 2D. The maximum $B_{r}$ applied to winding of HTS transformer is 0.112 T and the characteristics of HTS transformer were also obtained. But in this type of winding arrangement, reciprocal arrangement, the generated ac-loss to the HTS windings is very high because of the applied $B_{r}$ to HTS windings. Therefore, in order to reduce the generated ac-loss to the HTS windings, the new design of HTS transformer with concentric winding arrangement is presented in this paper and the 2-D non-linear electromagnetic analysis and the ac-loss for HTS transformer with the concentric winding arrangement is also carried out.

  • PDF

Test and Analysis of 3-D of Leakage Impedances in a Single-Phase 1MVA HTS Transformer (단상 1MVA 고온초전도 변압기의 누설임피던스 3차원 해석 및 시험)

  • Kim, Sung-Hoon;Kim, Woo-Seok;Lee, Sang-Jin;Choi, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Hahn, Song-Yop;Song, Hee-Suck;Park, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1003-1005
    • /
    • 2003
  • In this paper, 3-D nonlinear electromagnetic analysis of a single phase 1MVA 22.9 kV/6.6 kV high temperature superconducting(HTS) transformer with double pancake windings was accomplished. The characteristics of 1MVA HTS transformer such as The efficiency, voltage regulation and % impedance voltage drop were obtained by the 3-D non-linear electromagnetic analysis. And in order to verify the 3-D non-linear electromagnetic analysis of a single phase 1MVA HTS transformer, a 1MVA test transformer with windings made of copper tapes with the same size as BSCCO-2223 HTS tape was manufactured. The energy conservation method to perform the analysis of leakage impedances of both a 1MVA HTS transformer and test transformer was used. The characteristic analysis such as efficiency, voltage regulation and % impedance voltage drop of transformer was performed. And the obtained values of both 1MVA HTS transformer and test transformer were compared.

  • PDF

Analysis of Power Quality by Transformer Inrush Current (변압기 여자돌입에 의한 전력품질 분석)

  • Seo, Hun-Chul;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Young-Sik;Cho, Burm-Sup
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.932-937
    • /
    • 2008
  • The transformer inrush current can cause a voltage drop by source impedance. This current can impact sensitive loads by the voltage drop. Therefore, it is necessary to take measures to limit this inrush current. This study, described in this paper, analyzes the power quality affected by transformer inrush current using the X power system in Korea. The Electromagnetic Transients Program(EMTP) is used to analyze the transient phenomenon. We discuss a method to model the hysteresis curve of the transformer in EMTP. We carried out various simulations to analyze the power quality during transformer energization. The analysis results of voltage drop by the inrush current occurrence when certain requirements are met are presented.

Analysis of Characteristics in Transformer by using Coupling Coefficient Type Equivalent Circuit (결합계수형 등가회로에 의한 변압기의 특성해석)

  • 이광직;김주홍
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.86-92
    • /
    • 1995
  • In the analysis of characteristic behaviors of a real transformer with coupling coefficient K is less than 1, this paper presents the more accurate and practical profits than the traditional analysis of the transformer treated as K∼1. This results from the use of the coupling coefficient type equivalent circuit of the transformer which includes K as positive parameter. Furthermore, a leakage transformer is analyzed in a unified method and the results of analysis are consistent with the practical measurements of the transformer. By using the above equivalent circuit, the characteristics referred to the load side are expressed as Thevenin voltage source and the leakage inductor (1-K2)L2. Therefore, these analysis about the output voltage and the damping factor in the transient state which are affected by the leakage inductor are confirmed to be an effective method.

  • PDF

High Efficiency Step-Down Flyback Converter Using Coaxial Cable Coupled-Inductor

  • Kim, Do-Hyun;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.214-222
    • /
    • 2013
  • This paper proposes a high efficiency step-down flyback converter using a coaxial-cable coupled-inductor which has a higher primary-secondary flux linkage than sandwich winding transformers. The structure of the two-winding coaxial cable transformer is described, and the coupling coefficient of the coaxial cable transformer and that of a sandwich winding transformer are compared. A circuit model of the proposed transformer is also obtained from the frequency-response curves of the secondary short-circuit and of the secondary open-circuit. Finally, the performance of the proposed transformer is validated by the experimental results from a 35W single-output flyback converter prototype. In addition, the proposed two-winding coaxial transformer is extended to a multiple winding coaxial application. For the performance evaluation of the extended version, 35W multi-output hardware prototype of the DC-DC flyback converter was tested.

A Study on the Transformer Design considering the Inrush Current Reduction in the Arc Welding Machine

  • Kim, In-Gun;Liu, Huai-Cong;Cho, Su-Yeon;Lee, Ju
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.374-378
    • /
    • 2016
  • The transformer used in an inverter type arc welding machine is designed to use high frequency in order to reduce its size and cost. Also, selecting core materials that fit frequency is important because core loss increases in a high frequency band. An inrush current can occur in the primary coil of transformer during arc welding and this inrush current can cause IGBT, the switching element, to burn out. The transformer design was carried out in $A_P$ method and amorphous core was used to reduce the size of transformer. In addition, sheet coil was used for primary winding and secondary winding coil considering the skin effect. This paper designed the transformer core with an air gap to prevent IGBT burnout due to the inrush current during welding and proposed the optimum air gap length.

Fabrication and Properties of Piezoelectric Transformer for Step-Down Voltage using Ceramic Stack Process (세라믹 적층공정을 이용한 강압용 압전변압기의 제작 및 특성)

  • Lee, Chang-Bae;Yoon, Jung-Rag
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.164-164
    • /
    • 2009
  • A multilayer piezoelectric transformer(MPT) for step-down voltage was made by ceramic stack process. And then, the characteristics of piezoelectric transformer, such as resonance frequency, matching impedance, electro-mechanical coupling coefficient, voltage gain, heat generation and efficiency, are analyzed. The piezoelectric transformer consists of a lead zirconate titanate ceramic with a high electromechanical quality factor. The piezoelectric transformer, with a multilayered construction in the thickness direction, was formed with dimensions 15mm long, 15mm wide and 5mm thick.

  • PDF

Expert System for Fault Diagnosis of Transformer

  • Kim, Jae-Chul;Jeon, Hee-Jong;Kong, Seong-Gon;Yoon, Yong-Han;Choi, Do-Hyuk;Jeon, Young-Jae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.1
    • /
    • pp.45-53
    • /
    • 1997
  • This paper presents hybrid expert system for diagnosis of electric power transformer faults. The expert system diagnose and detect faults in oil-filled power transformers based on dissolved gas analysis. As the preprocessing stage, fuzzy information theory is used to manage the uncertainty in transformer fault diagnosis using dissolved gas analysis. The Kohonen neural network takes the interim results by applying fuzzy informations theory as inputs, and performs the transformer fault diagnosis. The Proposed system tested gas records of power transformers from Korea Electric Power Corporation to verify the diagnosis performance of transformer faults.

  • PDF

Comparison of vibration and noise of higher utility factor Insulation Panel for Transformer (변압기용 고효율 차음판의 진동 및 소음 비교)

  • Jeong, J.H.;Lee, J.H.;Jeong, H.E.;Lim, D.S.;Kim, J.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.112-116
    • /
    • 2007
  • Highly damped insulation panel for transformer construction is needed in residential area because the making noise from transformer substation in inner city is appeared a lost of problem by increasing to conserve living environment. Therefor in this paper, the vibration and noise characteristic effect of cork-type and sponge-type that is attached between insulation panel and enforce beam in transformer is analized using real size transformer experimentally.

  • PDF