• Title/Summary/Keyword: 힘 측정

Search Result 564, Processing Time 0.031 seconds

The effect of heat to remove cement on implant titanium abutment and screw (시멘트 제거를 위해 가한 열이 임플란트 티타늄 지대주와 나사에 미치는 영향)

  • Yi, Hyo-Gyoung;Gil, Ki-Sung;Lee, Jung-Jin;Ahn, Seung-Geun;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.179-187
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effect of heat applied to disintegrate cement on the removal torque value and fracture strength of titanium abutment and abutment screw. Materials and methods: Implants, titanium abutments and abutment screws were prepared for each 20 piece. Implant abutments and screws were classified as the control group in which no heat was applied and the experimental group was heated in a vacuum furnace to $450^{\circ}C$ for 8 minutes and cooled in air. The abutments and screws were connected to the implants with 30 Ncm tightening torque at interval 10 minutes and the removal torque value was measured 15 minutes later. And the fracture strength of abutment screw was measured using universal testing machine. Results: The mean removal torque value was $27.84{\pm}1.07Ncm$ in the control group and $26.55{\pm}1.56Ncm$ in the experimental group and showed statistically significant difference (P < .05). The mean fracture strength was $731.47{\pm}39.46N$ in the control group and $768.58{\pm}46.73N$ in the experimental group and showed statistically no significant difference (P > .05). Conclusion: The heat applied for cement disintegration significantly reduced the removal torque value of the abutment screw and did not significantly affect fracture strength of the abutment screw. Therefore, in the case of applying heat to disintegrate cement it is necessary to separate the abutment screw or pay attention to the reuse of the heated screw. However further studies are needed to evaluate the clinical reuse of the heated screw.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF

Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique (다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구)

  • Kim, Dong-Wook;Choi, Yu-Sung;Jo, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.343-358
    • /
    • 2011
  • As implant treatment has become popular, lots of different shapes and materials of the implant upper component have been supplied. And there are also diverse reports about failures including loosening of the abutment screw which is one of the most common reason. Purpose : The purpose of this study is to find out how different screw tightening orders and methods influence on screw loosening according to the different connection systems. The upper component was fabricated by casting method. After fabricating master models that are precisely attached to the upper component, 5 experimental models each for the external connection system and internal connection system were fabricated using splinting impression technique. First, to find out the influence of the screw tightening order, screws were tightened in 3 orders; 1-2-3-4, 2-3-1-4, 2-4-3-1. After tightening, removal torque values (RTV) of each group was measured. And also to find out the influence of screw tightening method, a model with 2-3-1-4 screw tightening order was tightened with 30 Ncm at one time(1-step method) and the RTV was compared with the same order group (2-3-1-4) in the 2 step method. In the external connection system, RTV appeared significantly lower in group 2-3-1-4 than group 2-4-3-1 (p<0.05). And also in the internal connection system, the RTV of group 2-3-1-4 appeared significantly lower than that of group 2-4-3-1 and 1-2-3-4 (p<0.05). When comparing the tightening number of the screw without considering the screw tightening order, the first tightened screw appeared significantly higher RTV than the second one in the external connection system (p<0.05), however there was no significant difference from the first tightened screw to the last tightened screw in the internal connection system. And there was no statistically significant difference between the two screw tightening methods in both internal and external connection system. In the comparison of external and internal connection system, each RTV appeared 16.27 Ncm and 14.25 Ncm and appeared as a statistically significant difference (p<0.05). There was a significant difference in RTV measured according to the screw tightening order. The lowest RTV appeared in the groups started tightening from the middle. There was also a significant difference in RTV between the two connection system groups. A further study is needed to find out the influence factors in RTV and also a study is required related to the load condition.

The Experimental Study for Myocardial Preservation Effect of Ischemic Preconditioning (허혈성 전조건화 유발이 심근보호에 미치는 영향에 관한 실험적 연구)

  • 이종국;박일환;이상헌
    • Journal of Chest Surgery
    • /
    • v.37 no.2
    • /
    • pp.119-130
    • /
    • 2004
  • Decrease in cardiac function after open heart surgery is due to an ischemia induced myocardial damage during surgery, and ischemic preconditioning, a condition in which the myocardial damage does not accumulate after repeated episodes of ischemia but protects itself from damage after prolonged ischemia due to myocytes tolerating the ischemia, is known to diminish myocardial damage, which also helps the recovery of myocardium after reperfusion, and decreases incidences of arrythmia. Our study is performed to display the ischemic preconditioning and show the myocardial protective effect by applying cardioplegic solution to the heart removed from rat. Material and Method: Sprague-Dawley male rats were used, They were fixed on a modified isolated working heart model after cannulation. The reperfusion process was according to non-working and working heart methods and the working method was executed for 20 minutes in which the heart rate, aortic pressure, aortic flow and coronary flow were measured and recorded. The control group is the group which the extracted heart was fixed on the isolated working heart model, recovered by reperfusion 60 minutes after infusion and preserved in the cardioplegic solution 20 minutes after the working heart perfusion and aortic cross clamp, The thesis groups were divided into group I, which ischemic hearts that were hypoxia induced were perfused by cardioplegic solution and preserved for 60 minutes; group II, the cardioplegic solution was infused 45 seconds (II-1), 1 minutes (II-2), 3 minutes (II-3), after the ischemia induction, 20 minutes after working heart perfusion and aortic cross clamp; and group III, hearts were executed on working heart perfusion for 20 minutes and aortic cross clamp was performed for 45 seconds (III-1), 1minute (III-2), 3 minutes (III-3), reperfused for 2 minutes to recover the heart, and then aortic cross clamping was repeated for reperfusion, all the groups were compared based on hemodynamic performance after reperfusion of the heart after preservation for 60 minutes. Result: The recovery time until spontaneous heart beat was longer in groups I, II-3, III-2 and III-3 to control group (p<0.01). Group III-1 (p<0.05) had better results in terms of recovery in number of heart rates compared to control group, and recovered better compared to II-1 (p<0.05). The recovery of aortic blood pressure favored group III-1 (p<0.05) and had better outcomes compared with II-1 (p<0.01). Group III-1 also showed best results in terms of cardiac output (p<0.05) and group III-2 was better compared to II-2 (p<0.05). Group I (p<0.01) and II-3 (p<0.05) showed more cardiac edema than control group. Conclusion: When the effects of other organs are dismissed, protecting the heart by infusion of cardioplegic solution after enforcing ischemia for a short period of time before the onset of abnormal heart beats for preconditioning has a better recovery effect in the cardioplegic group with preconditioning compared to the cardioplegic solution itself. we believe that further study is needed to find a more effective method of preconditioning.

Effect of Physical Training on Pulmonary Function (체력단련(體力鍛鍊)이 폐기능(肺機能)에 미치는 효과(效果))

  • Nam, Pal-Soo;Hwang, Soo-Kwan;Kim, Hyeong-Jin;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.37-43
    • /
    • 1981
  • In the present study, an effort was directed to elucidate the effect of the physical training on the pulmonary function. Twenty-four male athletics major students who have undergone regular physical training for more than five years were randomly chosen as the athletic subjects, and 12 regular male students who have not been engaged in any form of regular physical exercise or training were chosen as the non-athletic subjects, and a comparison was made between the two groups. The following were mainly observed by spirometry for the study; respiratory rate, tidal volume, vital capacity, maximum voluntary ventilation(MVV), forced expiratory volume for 1 second$(FEV_1)$, percent $FEV_1$ to forced vital capacity$(FEV_1%)$, forced expiratory flow for initial 1 liter$(FEF_{0.2-1.2}L)$, and forced mid-expiratory flow$(FEF_{\;25-75}%)$. The results obtained are summarized as follow. 1) The respiratory rate, tidal volume, and vital capacity showed no significant difference between athletes and non-athletes. The MVV in athletes was significantly (p<0.01) increased to $148.1{\pm}3.1\;L/min$ comparing with $118.3{\pm}9.1\;L/min$ in non-athletes. 2) $FEV_1$ was $3.310{\pm}0.070\;L$ in athletes and $2.779{\pm}0.104$ in non-athletes; $FEV_1%\;83.63{\pm}1.29%$ in athletes and $75.33{\pm}1.75%$ in non-athletes, both showing significant(p<0.01) increase in athletes. 3) $FEF_{0.2-1.2}L$ was $297.1{\pm}13.5\;L/min in athletes and $222.7{\pm}15.0\;L/min$ in non-athletes; $FEF_{\;25-75}%$ was $3.543{\pm}0.109\;L/sec$ in non-athletes, both showing significant(p<0.01) increase in athletes. 4) Some discussions were made on these results. The lung volumes showed no significant difference between the two groups. But MVV, $FEV_1$, $FEV_1%$, $FEF_{0.2-1.2}L$ and $FEF_{25-75}%$ in athletes were significantly(p<0.01) higher than in non-athletes. It is therefore concluded that the athletes have more powerful respiratory muscles, or higher compliance of the lung and thorax than the non-athletes.

  • PDF

Effect of orthodontic force on the amount of tooth movement and root resolution in rat (교정력이 흰쥐의 치아이동량과 치근흡수에 미치는 영향)

  • Kim, Il-Gon;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.551-562
    • /
    • 1999
  • This study was undertaken to investigate the relation between orthodontic force magnitude and the amount of tooth movement. And more light force application for reducing root resorption Twenty-four rats were divided into three experimental groups(A, B, C) based on force magnitude and application method. Springs of 50g force were applied to A group, springs of 100g force were applied to B group and springs of 25g force were applied to C group initially, and after 4 days springs of C group were changed to springs of 50g force. Two kinds of $sentally^{(R)}$(GAC U.S.A.) closed coil spring, 50g and 100g, were used. And we made 25g springs by heat treatment process of 50g springs. Each spring was inserted between the maxillary central incisor and the maxillary left first molar. Amounts of tooth movement were measured everyday by digital caliper($Digimatic^{(R)}$, Mitutoyo, Japan) under inhalation anesthesia for 15 days. After 15 days, all rats were sacrificed and histological samples were obtained with Hematoxyline-Eosin stain and Masson's trichrome stain. Following conclusion were made; 1. Group B showed the mean cumulative tooth movement of $2.19{\pm}0.41mm$ at 15th day, which was greatest among three groups, followed by group C($2.06{\pm}0.10mm$), group A($1.90{\pm}0.49mm$) respectively. however, there was no statistically difference among three groups. 2. All groups showed general tooth movement pattern and A, B, C group finished lag phase at 9th, 8th, 7th day, but there was no statistical significance. 3. Group A,B,C showed root resorption and especially group B showed the most severe root resorption and group C showed milder root resorption than other groups. According to the above results, large initial force with the development of a flirty widespread hyalinized zone may cause severe root resorption, so initial force should be applied lightly to reduce hyalinized area and eventually root resorption and then increased force will induce efficient tooth movement.

  • PDF

Effects of heat treatment on the load-deflection properties of nickel-titanium wire (니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화)

  • Chang, Soo-Ho;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.349-359
    • /
    • 2006
  • Objective: Nickel-titanium alloy wire possesses excellent spring-back properties, shape memory and super-elasticity. In order to adapt this wire to clinical use, it is necessary to bend as well as to control its super-elastic force. The purpose of this study is to evaluate the effects of heat treatment on the load-deflection properties and transitional temperature range (TTR) of nickel-titanium wires. Methods: Nickel-titanium wires of different diameters ($0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ and $0.0215"\;{\times}\;0.028"$) were used. The samples were divided into 4 groups as follows: group 4, posterior segment of archwire (24 mm) without heat treatment; group 2, posterior segment of archwire (24 mm) with heat treatment only; group 3, anterior segment with bending and heat treatment; group 4, anterior segment with bending and 1 sec over heat treatment. Three point bending test was used to evaluate the change in load-deflection curve and obtained DSC (different scanning calorimetry) to check changes in $A_f$ temperature. Results: In the three point bending test, nickel-titanium wires with heat treatment only had higher load-deflection curve and loading and unloading plateau than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment had lower Af temperature than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment and bending had higher load-deflection curve than nickel- titanium wires with heat treatment and nickel-titanium wires without heat treatment. Nickel-titanium with heat treatment of over 1 sec and bending had the highest load-deflection curve. Nickel-titanium wires with heat treatment and bending had lower Af temperature, Nickel-titanium wires with heat treatment of over Af sec and bending had the lowest Af temperature. Conclusion: From the results of this study, it can be stated that heat treatment for bending of Nickel-titanium wires does not deprive the superelastic property but can cause increased force magnitude due to a higher load-deflection curve.

Changes in midpalatal suture area and adjacent periodontal tissues of individual tooth following rapid palatal expansion in young adult dogs ; Histomorphologic and immunohistochemical study (유성견 급속 구개확장시 정중구개봉합부 및 치아주위 조직 변화에 관한 조직형태학적 및 면역조직화학적 연구)

  • Lee, Ju-Young;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.317-333
    • /
    • 2000
  • The purpose of this study was to determine the proliferative activity of the osteoblasts and fibroblasts in the midpalatal area and to investigate the adjacent periodontal tissues of individual tooth following rapid expansion of the palate. Ten young adult dogs, aged approximately ten months, were used in the experiment. The experimental design was consisted of 1 week expansion group(Group E1, 3 dogs), 2 week expansion group(Group E2, 3 dogs), 2 week expansion and 2 week retention group(Group E3, 3 dogs), and control group(Group C, 1 dog). For each group, expansion screw was activated one time per day(1/4 turn;$90^{\circ}$) following Hyrax-screw application. The experimental animals in each group were sacrificed at 1, 2 and 4 weeks following palatal expansion. Maxillary tissue blocks were obtained and prepared ior the histomorphologic and immunohistochemical studies. Light mcroscope, polarizing microscope, and soft X-ray apparatus were used in this study, and following results were obtained. 1. In polarizing microscopic study, the expansion groups(E1 & E2) showed blue color representing bone resorption and new bone formation in midpalatal suture area. E3 groups skewed less blue color compared to the E1 and E2 group. But yellow color increased by calcification in the E3 groups. 2. Immunohistochemical study revealed that positive responses of the osteoblasts to PCNA and undifferentiated fibroblasts to EGF in E1 group were somewhat increased. Positive response to PCNA and EGF were increased in fibroblasts and the osteoblasts forming new bone in E2 group. In E3 group, the positive response cell concentrated the periphery of edge of palatal process in both PCNA and EGF. 3. Throughout the expansion period(E1 & E2), light microscopic study showed the edges of the extensive resorption and new palatal processes, indicating bone remodeling within the suture. E3 group exhibited less remodeling of midpalatal suture area. E2 group and E3 group showed cementum formation and resorption at the apex of 3rd premolar and 1st molar E3 group exhibited extensive hyalinized zone on the cervical portion of buccal side of 1st molar. 4. Soft X-ray analysis of E1 group showed hypomineralized defect and microfractures in various parts of the suture areas when compared with control animals. There was no significant difference in the degree of mineralization in the midpalatal suture region between the C and E3 groups. Tooth axis showed tipping of 3rd premolar and 1st molar in the E2 group and E3 group. Based upon these experimental results, it is concluded that the undifferentiated mesenchymal cells always presented in midpalatal suture area following RPE. Differentiated osteoblasts and fibroblasts possess proliferating cellular activity until the 2 week retention period. The posterior teeth are tend to tip buccally as RPE force applied. Retention group exhibited irreversible response with severe hyalinized zone on the buccal surface of the first molar.

  • PDF

Comparison of the Strain on the Alveolar Ridge According to the Occlusal Scheme of Complete Dentures (총의치 교합양식에 따른 응력 분포 양상 비교연구)

  • Choi, Won-Jun;Lim, Young-Jun;Kim, Chang-Whe;Kim, Myung-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • The purpose of this study was to compare the strain on the alveolar ridge in the centric, eccentric and protrusive position according to the occlusal scheme (bilateral balanced occlusion with 33 degree anatomical teeth, group B; monoplane occlusion with non-anatomical teeth, group M; lingualized occlusion with 33 degree anatomical teeth and non-anatomical teeth, group L; of complete dentures. Experimental dentures were set bilateral balanced occlusion, lingualized occlusion and monoplane occlusion. They are analysed through T-Scan II(Tekscan, Boston, U.S.A) and 1.5mm thick layer was removed from the denture-supporting surface of resin model and then replaced with silicone to simulate resilient edentulous ridge mucosa. A $4{\times}6$ linear strain gauge is attached to the $1^{st}$ premolar and $1^{st}$ molar area. The strain values are recorded according to the occlusal scheme in the centric, eccentric and protrusive position after uniformly applying 50 N and 150 N force through a Universal Testing Machine(instron$^{(R)}$ 5567, Bluehill 2.0 software ,U.S.A.) with the models mounted in the articulator. When performing centric and protrusive occlusion, the three groups of occlusal scheme were compared in the anterior region and in the posterior region. The strains of each group were also compared in the working side and in the non-working side during eccentric excursion. It was observed that the strain in the bilateral balanced occlusion showed a higher value than the lingualized occlusion and monoplane occlusion in every position except the non-working side. However, during the eccentric movement the strain value in the non-working side showed the lowest value in the bilaterally balanced occlusion. The strain change amount from the working side or centric occlusion to non-working side and also the strain variation rate within the non-working side showed the highest value in bilateral balanced occlusion.