• Title/Summary/Keyword: 힘 측정

Search Result 566, Processing Time 0.032 seconds

COMPARISON OF COMPRESSIVE STRENGTH AND SURFACE MICROHARDNESS BETWEEN FLOWABLE COMPOSITE RESIN AND GIOMER (유동성 자이오머와 복합 레진의 압축 강도 및 표면 미세 경도 비교)

  • Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.4
    • /
    • pp.383-388
    • /
    • 2012
  • The aim of this study was to compare the compressive strength and the surface microhardness of Beautifil flow (Shofu, Kyoto, Japan) with $Filtek^{TM}$ Z350, Z350XT (3M ESPE, USA). Fifteen specimens from each material were fabricated for testing. Compressive strength was measured by using a universal testing machine at a crosshead speed of 1 mm/min. Surface microhardness values were measured by using Vickers hardness tester under 4.9 N load and 10 seconds dwelling time. The compressive strength of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $218.7{\pm}18.4$ MPa and Group 1 $Filtek^{TM}$ Z350 was $205.5{\pm}27.1$ MPa. Group 3 Beautifil flow F00 was $176.5{\pm}30.3$ MPa, and Group 4 Beautifil flow F10 was $173.4{\pm}26.2$ MPa. The compressive strength of Group 2 is higher than Group 3 and 4 (p < 0.05). The surface microhardness of Group 2 $Filtek^{TM}$ Z350XT shows the highest value as $39.1{\pm}2.1$ and Group 4 Beautifil flow F10 was $27.9{\pm}1.8$. And Group 3 Beautifil flow F00 was $23.1{\pm}1.1$, Group 1 $Filtek^{TM}$ Z350 was $20.4{\pm}0.9$. There was a statistical significant difference in surface microhardness between all groups (p < 0.05). In conclusion, the compressive strength of giomer was below the level of flowable composite resin. However, the surface microhardness of giomer is comparable to that of flowable composite resin. Giomer would be the good alternative to composite resin, if there is improvement of the compressive strength of giomer.

Fracture resistance of zirconia and resin nano ceramic implant abutments according to thickness after thermocycling (지르코니아와 레진나노세라믹 임플란트 지대주의 두께에 따른 열순환 후 파절저항)

  • Lee, Jung-Won;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.144-150
    • /
    • 2017
  • Purpose: The aim of this in vitro study is to investigate load bearing capacity of esthetic abutments according to the type of material and wall thickness. Materials and methods: 70 specimens equally divided into seven groups according to their abutment wall thicknesses. The abutments prepared with titanium 0.5 mm wall thickness were used as a control group (Ti-0.5), whereas zirconia abutments and resin nano ceramic abutments with wall thickness 0.5 mm, 0.8 mm and 1.0 mm were prepared as test groups (Zir-0.5, Zir-0.8, Zir-1.0 and RNC-0.5, RNC-0.8, RNC-1.0). All specimens were tested in a universal testing machine to evaluate their resistance to fracture and all of them underwent thermo-cycling before loading test. Mean fracture values of the groups were measured and statistical analyses were made using two-way ANOVA. Results: Zir-1.0 showed the highest mean strength ($2,476.3{\pm}342.0N$) and Zir-0.8 ($1,518{\pm}347.9N$), Ti-0.5 ($1,041.8{\pm}237.2N$), Zir-0.5 ($631.4{\pm}149.0N$) were followed. The strengths of RNC groups were significantly lower compared to other two materials (RNC-1.0 $427.5{\pm}72.1$, RNC-0.8 $297.9{\pm}41.2$) and the strengths of all the test groups decreased as the thickness decreases (P < .01). RNC-0.5 ($127.4{\pm}35.3N$) abutments were weaker than all other groups (P < .05). Conclusion: All tested zirconia abutments have the potential to withstand the physiologic occlusal forces in anterior and posterior regions. In resin nano ceramic abutments, wall thickness more than 0.8 mm showed the possibility of withstanding the occlusal forces in anterior region.

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

Tongue and lip strength in children with and without speech sound disorders (말소리장애 아동과 일반 아동 간 입술 및 혀 근력 비교 연구)

  • Jicheol Bang;Ji-Wan Ha;Seong-Tak Woo;Hyunjoo Choi;Sungdae Na;Sung-Bom Pyun
    • Phonetics and Speech Sciences
    • /
    • v.16 no.3
    • /
    • pp.59-69
    • /
    • 2024
  • Among the subgroups of speech sound disorder (SSD), the motor speech disorder (MSD) group is characterized by weak articulatory force. This study quantitatively measured and compared articulatory muscle strength between SSD and typically developing (TD) children. The Iowa Oral Performance Instrument (IOPI) was used to measure lip and tongue strength in 15 children with SSD and 15 TD children. We additionally measured peak lip and tongue pressure and endurance, and analyzed the correlation between each strength measure and the percentage of consonants correct (PCC). The findings were as follows: First, lip strength for the bilabial sounds did not differ between the two groups in the initial position but was significantly weaker in the SSD group in the final position. Tongue strength for alveolar sounds was weaker in the SSD group than in the TD group for the initial and final positions. Second, for lip and tongue strength, the difference in voicing features was significant in the TD group but not in the SSD group. Third, the peak pressure and endurance of the lips and tongue were significantly lower in the SSD group than in the TD group. Fourth, significantly higher static correlations were observed between most strength measures and the PCC. These findings suggest that weakness in articulatory motor execution may be an unrecognized underlying problem of SSD with unknown origin.

Comparison of bracket bond strength in various directions of force (교정용 브라켓에 가해지는 힘의 방향에 따른 결합강도의 비교)

  • Lee, Hyun-Jung;Lee, Hyung-Soon;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.359-370
    • /
    • 2003
  • The purpose of this study was to evaluate the bond strength of orthodontic brackets bonded to metal bar with chemically cured adhesive (Ortho-one, Bisco Co, USA) in various types and directions of force application. Three types of metal bracket with different bracket base configurations; Micro-Loc base(Tomy Co, Japan), Chessboard base(Daesung Co, Korea), Non-etched Foil-Mesh base(Dentaurum, Germany); were used in this study. Peel, shear, tensile bond strengths were measured by universal testing machine and compared each other. The peel force directions applied were $0^{\circ},\;15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ},\;75^{\circ},\;90^{\circ}$ And then, in consideration of the different surface area of the bracket bases, the bond strength Per unit area were calculated and compared. The results obtained were summarized as follows: 1. The bond strengths according to the types and the directions of the forces were greatest at the shear forces in all three bracket base configuration groups(p<0.01). 2. As the peel force direction grew higher in degree, peel bond strength decreased. The Patterns of peel bond strength change according to force direction was similar in all three bracket base configurations. The minimum bond strength was 60 degree-peel bond strengths in all three bracket base configurations. 3. In Micro-Loc base group, minimum peel bond strength$(_{60}PBS)$ was in $29\%$ level of shear bond strength and $52\%$ level of tensile bond strength. In Chessboard base group, $_{60}PBS$ was in $34\%$ level of shear bond strength and $61\%$ level of tensile bond strength. In Non-etched Foil-Mesh base group, $_{60}PBS$ was in $34\%$ level of shear bond strength and $55\%$ level of tensile bond strength. 4. The bond strengths per unit area were lowest in Non-etched Foil-Mesh base group and highest in Chessboard base group(p<0.05). However, there were no differences in shear bond strength, tensile bond strength, $75^{\circ}\;and\;90^{\circ}$ per unit area between Micro-Loc and Chessboard base groups.

The Kinematics Analysis of the Badminton High Clear Motion in Woman Middle School Student (여자중학생 배드민턴 하이클리어 동작의 운동학적 분석)

  • Kim, Chang-Bum;Ryu, Jae-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.91-107
    • /
    • 2002
  • This research got the following conclusion as result that analyzed high clear action kinematically to 4 C girls' junior high school badminton players who are situated in Chungchong-bukdo. 1. Most of the subject didn't rotate their right shoulder and elbow joint at back swing and moved speedy to shuttle cock. And an cooperation action of joint decreases displaying only a good action on both subject`s specification joint part. 2. When the subject S1 and S2 swing slowly and largely the joint of shoulder and elbow and then the speed of right wrist and racket head is fast, the cooperation action of joint is better than other subject. 3. An angle change of right shoulder showed angle that all subjects are great being caused in softness of joint and angular velocity was exposed that load enough Impact force and increase the speed of racket head as angular velocity decreases rapidly in Impact except subject S3. 4. All subjects of right elbow angle change showed similar form and was exposed that subject S2 sees form of impact stage serious bends from back swing and do not use force effectively in angular velocity. 5. Angle of right wrist appeared that the speed of shuttle cock is decelerated because fast bends of wrist is not formed shortly after Impact because all subject do not accomplish big angle shortly after back swing. Angular velocity can assume that the subject S1 and S4 are using and move fast strong snap shot offering angular velocity value of Impact stage sound (-). 6. While size of Impact stage knee angle accomplishes angle that is big both subject, hip joint angles sees small angle and is playing swing that do on upper body and arm without using strong waist force that is composition action with knee and hip joint.

Physical Properties of Pericarp in a Walnut Cultivar, 'Yongdong' (호도나무 '영동' 품종 과피의 물리적 특성)

  • Lee, Uk;Lee, Moon-Ho;Byun, Kwang-Ok;Jung, Myung-Suk
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.4
    • /
    • pp.455-461
    • /
    • 2007
  • This research was processed on morphological and physical characteristics of 'Yongdong' cultivar nuts. (1)Morphological properties of 'Yongdong' cultivar nuts were significantly different from the control, native species, in respect of all properties. (2) 'Yongdong' cultivar nuts showed higher figures than the native species on 9 items of morphological properties (kernel weight, size, length and width of pad on suture and etc.), whereas other 6 items (height of pad on suture, thickness of shell and septem, fragment numbers of isolated kernel, roundness index, and etc.) showed lower figures than those of the control. (3) In physical properties of the nut shells, 'Yongdong' cultivar was superior to the control at all items with the exception of compressive prove distance. Accordingly, it was also verified as effective cultivar of shelled walnut with suture line direction applied the minimum strength. (4) 'Yongdong' cultivar, 21.9 kg, was approximately twice lower than the control, 42.6 kg, on maximum compressive weight. It was demonstrated that the 'Yongdong' cultivar characterized by easily crushing shell by small strength was great in cracking properties. (5) On the study of yield strength, the native species being twice higher than 'Yongdong' cultivar showed the properties of the small elasticity and the shell hardness. While, the suture line of 'Yongdong' cultivar having the lowest yield strength 15.6 kg and 16.0 kg was identified the shell crushed easily. (6) The movement distance of the compressive prove of 'Yongdong' cultivar, 4.2 mm, was longer than that of the control, 2.7 mm. Subsequently, it means that the amount of loss possibly occurring to distribution process was not great, whereby productive value was high. (7) The compressive strength of the suture line of 'Yongdong' cultivar, $9.1kg/cm^2$, was much lower than total average of that $12.4kg/cm^2$. It was also statistically different with other properties. (8)The hardness examination by the compressive position revealed that the suture line of 'Yongdong' cultivar, $149.8kg/cm^2$, was lowest in contrast with the control, $300.9kg/cm^2$.

Development and Reliability of Intraoral Appliance for Diagnosis and Control of Bruxism (이갈이 진단 및 조절용 구내장치의 개발과 신뢰도 조사)

  • Kim, Seung-Won;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.1
    • /
    • pp.69-77
    • /
    • 2005
  • The purposes of this study were to develop and introduce a novel intraoral appliance for bruxism composed of power switch and biofeedback device and further to examine inter- and intra-reliability of the appliance prior to clinical tests. The newly-developed appliance consisted of detection sensors, a central processing unit (CPU), a reactor and a storage unit and a displayer. Compact-sized, waterproof switches were selected as bruxism detection sensor and any sensor activation by clenching or grinding event was processed at the CPU and transmitted, by radio wave, to the reactor and storage unit and triggered auditory or vibratory signal, subsequently producing biofeedback to the patient with bruxism. The data on bruxing event in the storage unit can be displayed on the computer, making it possible analyzing frequency, duration and nature of bruxism. Cast models were obtained from ten volunteers with normal occlusion to evaluate reliability of the appliances. For inter-operator reliability on the intraoral appliances, each operator of the two fabricated the appliance for the same subject and compared the minimal contact forces provoking auditory biofeedback reaction in vertical, lateral and central directions. Intra-operator reliability was also investigated on the appliances made by a single operator at two separate times with an interval of two days. Conclusively, the newly-developed appliance is compact and safe to use in oral circumstance and easy to make. Furthermore, it had to be proven reliability excellent enough to apply in clinical settings. Thus, it is assumed that this appliance with the processor and the storage of data and auditory or vibratory biofeedback function is available and useful to analyze and control bruxism.

Detorque values of abutment screws in a multiple implant-supported prosthesis (다수 임플란트 지지 보철물에서 지대주 나사의 풀림 토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.280-286
    • /
    • 2010
  • Purpose: This study evaluated the detorque values of screws in a multiple implant-supported superstructure using stone casts made with 2 different impression techniques. Material and methods: A fully edentulous mandibular master model and a metal framework directly connected to four implants (Br${\aa}$nemark $System^{(R)}$; Nobel Biocare AB) with a passive fit to each other were fabricated. Six experimental stone casts (Group 1) were made with 6 non-splinted impressions on a master cast and another 6 experimental casts (Group 2) were made with 6 acrylic resin splinted impressions. The detorque values of screws ($TorqTite^{(R)}$ GoldAdapt Abutment Screw; Nobel Biocare AB) were measured twice after the metal framework was fastened onto each experimental stone cast with 20 Ncm torque. Detorque values were analyzed using the mixed model with the fixed effect of screw and reading and the random effect of model for the repeated measured data at a .05 level of ignificance. Results: The mean detorque values were 7.9 Ncm (Group 1) and 8.1 Ncm (Group 2), and the mean of minimum detorque values were 6.1 Ncm (Group 1) and 6.5 Ncm (Group 2). No statistically significant differences between 2 groups were found and no statistically significant differences among 4 screws were found for detorque values. No statistically significant differences between 2 groups were also found for minimum detorque values. Conclusion: In a multiple external hexagon implant-supported prosthesis, no significant differences between 2 groups were found for detorque values and for minimum detorque values. There seems to be no significant differences in screw joint stability between 2 stone cast groups made with 2 different impression techniques.

The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials (구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향)

  • Lee, Ah-Reum;Chung, Chung-Hoon;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • Purpose: This study is designed to investigate the various impacts of different types of scaler tips such as cooper alloy base tip and the others on the surface roughness of teeth and implant by the method which is currently in clinical use. Materials and methods: Four different types of disc shaped porcelain, titanium, zirconia, and Type III gold alloy dental materials sized 15 mm diameter, 1.5 mm thickness were used for the experiment. Plastic hand curette (Group PS), cooper alloy new tip (Group IS), and stainless steel tip (Group SS) were used as testing appliances. A total of 64 specimens were used for this study; Four specimens for each material and appliance group. Surface roughness was formed with 15 degree angle in ultrasonic scaler tip and with 45 degree angle in hand curette of instrument tip and the specimen surface with 5 mm long, one horizontal-reciprocating motion per second for 30 seconds by 40 g force. To survey the surface roughness of each specimen, a field emission scanning electron microscope, an atomic force microscope, and a surface profiler were used. (Ra, ${\mu}m$). Results: According to SEM, most increased surface roughness was observed in SS group while IS groups had minimal roughness change. Measurement by atomic force microscope presented that the surface roughness of SS group was significantly greater than those of PS, IS and control groups in the type III gold alloy group (P<.05). IS group showed lesser surface roughness changes compared to SS group in porcelain and gold alloy group (P<.05). According to surface profiler, surface roughness of SS group showed greater than those of PS, IS and control groups and IS group showed lesser than those of SS group in all specimen groups. Type III gold alloy group had large changes on surface roughness than those of porcelain, titanium, zirconia (P<.05). Conclusion: The result of this study showed that newly developed copper alloy scaler tip can cause minimal roughness impacts on the surface of implant and dental materials; therefore this may be a useful alternative for prophylaxis of implant and restored teeth.