• Title/Summary/Keyword: 히스테리시스 밴드

Search Result 27, Processing Time 0.078 seconds

Capacitance-Voltage Characterization of Ge-Nanocrystal-Embedded MOS Capacitors (Ge 나노입자가 형성된 MOS 캐패시터의 캐패시턴스와 전압 특성)

  • Park, Byoung-Jun;Choi, Sam-Jong;Cho, Kyoung-Ah;Kim, Sang-Sig
    • Journal of IKEEE
    • /
    • v.10 no.2 s.19
    • /
    • pp.156-160
    • /
    • 2006
  • Capacitance versus voltage (C-V) curves of Ge-nanocrystal (NC)-embedded MOS capacitors with and without a single capping Al2O3 layer are characterized in this work. C-V curves of the Ge-NC-embedded MOS capacitor with the A12O3 layer are counterclockwise in the voltage sweeps, which indicates tile presence of charge storages in the Ge NCs by the tunnelling of charge carriers between the Si substrate and the Ge NCs. In the Ge-NC-embedded MOS capacitor without Al2O3 layer, clockwise hysteresis of the C-V curves and leftward shifts of the flat band voltages are observed for the embedded MOS capacitor without the Al2O3 layer. It is suggested that the characteristics of the C-V curves are due to the charge trapping at oxygen vacancies within a SiO2 layer. In addition, the illumination of the white light enhances the lower capacitance part of the C-V hysteresis. The origin for the enhancement is discussed in this paper.

  • PDF

$SnO_2$ 나노 입자가 분산된 Poly(methylmethacrylate) 박막 층을 사용하여 제작한 유기 쌍안정성 소자의 전기적 성질

  • Gwak, Jin-Gu;Yun, Dong-Yeol;Jeong, Jae-Hun;Lee, Dae-Uk;Son, Dong-Ik;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.210-210
    • /
    • 2010
  • 저항 구조를 가진 유기 쌍안정성 소자는 비휘발성 기억 소자 중에서 구조가 간단하고 제작비용이 저렴하며 플렉시블이 용이한 장점 때문에 많은 연구가 진행되고 있다. 유기물/무기물 복합재료를 사용한 유기 쌍안정성 소자 제작에 대한 연구는 많이 진행되어 왔지만, 넓은 에너지 밴드 갭을 가진 $SnO_2$ 나노 입자가 삽입된 고분자 박막을 기반으로 제작한 유기 쌍안정성 소자에 대한 연구는 상대적으로 미흡하다. 본 연구에서는 Poly(methyl methacrylate) (PMMA) 박막 안에 분산된 $SnO_2$ 나노 입자를 사용하여 제작한 유기 쌍안정성 소자의 전기적인 특성을 관찰하였다. 소자를 제작하기 위해 나노 입자의 전구체인 Tin 2-ethylhexanoate (95%) 2.4 mmol을 dibutyl ether (99.3%) 10 ml에 용해시킨 후, 용매열 화학적 방법을 사용하여 용매 안에서 $SnO_2$ 나노 입자를 합성하였다. 용매 안에 들어있는 1 wt%의 $SnO_2$ 나노 입자와 100 mg의 PMMA를 2 ml의 클로로벤젠에 용해하여 고분자 용액을 제작하였다. 하부 전극 역할을 하는 indium tin oxide가 증착된 유리 기판 위에 고분자 용액을 스핀 코팅하고, 열을 가해 용매를 제거하여 $SnO_2$ 나노 입자가 분산되어 있는 PMMA 박막을 형성하였다. 그 위에 Al 전극을 증착하여 기억 소자를 완성하였다. 제작된 유기 쌍안정성 소자의 전류-전압 (I-V) 측정 결과에서는 동일한 전압에서 서로 크기가 다른 전류가 흐르는 I-V 곡선의 히스테리시스 특성이 나타났다. 그러나 $SnO_2$ 나노 입자가 없는 PMMA 박막으로 형성된 유기 쌍안정성 소자에서는 I-V 곡선의 히스테리시스 특성이 나타나지 않았다. 따라서 PMMA 박막 안에 삽입된 $SnO_2$ 나노 입자가 유기 쌍안정성 소자의 메모리 효과에 결정적인 영향을 준 것을 알 수 있었다. 전류-시간 측정 결과에서는 소자의 ON/OFF 비율이 시간에 따라 큰 변화 이 없이 1000 사이클 이상 지속적으로 유지 하고 있음을 보여 줌으로써 유기 쌍안정성 소자를 장시간 사용할 수 있음을 나타내 주었다.

  • PDF

Adaptive Hysteresis Band Current Control Independent of the Back EMFs (역기전력에 무관한 가변 히스테리시스 밴드 전류 제어)

  • Kim, Kyeong-Hwa;Cho, Kwan-Yuhl;Chung, Se-Kyo;Oh, Dong-Seong;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1172-1175
    • /
    • 1992
  • The conventional adaptive hysteresis band current control technique has disadvantages such that on-line calculation of the hysteresis band is very complex, therefore, the adaptive hysteresis band must be stored in the look-up table. In this paper, a new simplified adaptive hysteresis band current control technique with phase decoupling is presented. The adaptive band is independent of the back EMFs. Using this adaptive band and the phase decoupled current error, the modulation frequency is fixed at nearly constant and the PWM inverter has optimal switching pattern.

  • PDF

Direct Torque Control according to Flux and Torque of Hysterisis Band (자속 및 토오크 히스테리시스 밴드폭에 따른 직접토오크 제어)

  • Choi, Youn-Ok;Jeong, Sam-Yong;Kim, Dae-Gon;Kim, Pyung-Ho;Cho, Geum-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1206-1208
    • /
    • 2001
  • Direct torque control(DTC) of AC motor has the fast torque and flux dynamic responses even though it has very simple scheme to implement. DTC is also very simple in its implementation because it needs only two hysteresis comparators and switching vector table for both flux and torque control. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple, switching frequency and current harmonics. Therefore, authors analysis flux and torque hysteresis bands is suggested considering switching frequency and harmonic distortion of currents.

  • PDF

A Double Band Hysteresis Current Control Method (이중밴드 히스테리시스 전류 제어 방식)

  • Oh W.H.;Yoo C.H.;Shin E.C.;Park S.M.;Noh H.Y.;Yoo J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.579-583
    • /
    • 2003
  • Hysteresis controllers are intrinsically robust to system parameters, exhibit very high dynamic response and are suitable for simple implementation. But the current control using a conventional hysteresis controller has the disadvantage that high switching frequency may happen due to lack of coordination among individual hysteresis controllers of three phases. This will of course increase the switching loss. In addition, the current error is not strictly limited. So, in this paper to reduce the switching frequency, a double band hysteresis current controller is proposed. The presented control system was tested with digital simulation in the Borland C++ program and demonstrate the advantage of proposed hysteresis current controller.

  • PDF

Direct Torque Control of Induction Motor Using Optimal Hysteresis Band Amplitude (최적의 히스테리시스 밴드 크기를 이용한 유도전동기의 직접토크제어)

  • Jeong, Byeong-Ho;Shin, Sa-Hyun;Lim, Byung-Ok;Lee, Kang-Youn;Cho, Geum-Bae;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1208-1210
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Synthesis of Ti-SBA-15 Doped with Lanthanide Ions and Their Photocatalytic Activity (란탄족 이온이 도핑된 Ti-SBA-15의 합성 및 그들의 광촉매 활성)

  • Hong, Seong-Soo
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2020
  • Ti-SBA-15 catalysts doped with lanthanide ions (Ln/Ti-SBA-15) were successfully synthesized using conventional hydrothermal method. In addition, they were characterized by XRD, FT-IR, DRS, BET, and PL. The activity of these materials on the photocatalytic decomposition of methylene blue under ultraviolet light irradiation was also examined. Ti-SBA-15 catalysts doped with various lanthanide ions maintained their mesoporous structure. The pore size and pore volume of Ln/Ti-SBA-15 materials decreased but their surface area increased upon the doping of lanthanide ion. Ln/Ti-SBA-15 materials exhibited the type IV nitrogen isotherm with desorption hysteresis loop type H2, which was characteristic of mesoporous materials. The size of hysteresis increased in the doping of lanthanide ions on Ti-SBA-15 material. There was no absorption in the visible region (> 400 nm) regardless of the doping of lanthanide ions to TiO2 particles, while the broad bands at 220 nm appeared at the Ln/Ti-SBA-15 samples, indicating the framework incorporation of titanium into SBA-15. 1 mol% Pr/ Ti-SBA-15 catalysts showed the highest photocatalytic activity on the decomposition of methylene blue but the Ti-SBA-15 catalysts doped with Eu, Er, and Nd ions showed lower activity compared to pure Ti-SBA-15 catalyst. The PL peaks appeared at about 410 nm at all catalysts while the excitonic PL signal was proportional to the photocatalytic activity for the decomposition of methylene blue.

A Study of Using Optimal Hysteresis Band Amplitude for Direct Torque Control of Induction Motor (유도전동기 직접토크제어의 히스테리시스 밴드 크기의 최적화에 관한 연구)

  • Jeong B.H.;Kim S.K.;Park J.K.;Oh G.K.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.812-815
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Reduction Method of Torque Ripple in Induction Motor using DTC with Constant Switching Frequency (일정 스위칭 주파수를 가지는 유도전동기 직접토크제어의 토크리플 저감기법)

  • La, Koang-Kyun;Shin, Myoung-Ho;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1257-1259
    • /
    • 2000
  • 직접토크제어(DTC)가 빠른 포크 응답을 가지고있다는 것은 널리 알려진 사실이다. 이것은 기존의 벡터 제어와는 달리 공간 전압벡터에 의해 직접적으로 토크와 자속이 제어되기 때문이다. 이로 인해 직접토크제어 기법은 그것이 도입되어진 1980년대 중반 이래로 노크의 빠른 응답을 필요로 하는 분야에 점차적으로 적용되어져 왔다. 하지만 이런 장점에도 불구하고 직접토크제어는 히스테리시스 밴드, 속도 그리고 전동기 파라메타의 변화에 따른 스위칭 주파수의 변화와 토크 리플의 증가, 좋은 성능을 위한 높은 제어 주기 등의 몇 가지 단점을 가지고 있었다. 그래서 DTC의 단점들을 해결하기 위해 여러 연구들이 이루어져 왔다. 본 논문에서는 이들 단점들 중 하나인 토크리플을 개선하려한다. 다른 논문들에서도 일정 주파수를 가지는 여러 제어 기법을 사용하여 직접토크제어의 단점을 해결하려 했지만 너무 복잡하고 큰 성능을 나타내지 못했으며 몇몇 논문들은 오히려 직접토크제어의 장점인 빠른 응답성을 잃는 결과도 가져왔다. 그래서 본 논문은 간단한 개념을 가지고 토크리플을 줄이며 일정 스위칭 주파수를 가지므로 DSP를 사용하여 제어하기 용이한 직접토크제어기법을 제안하려 한다.

  • PDF

A Study on Double Band Hysteresis Current Control based on 3-Level Inverter to reduce the harmonic component in output current of FACTS devices (FACTS 기기의 고조파 저감을 위한 이중밴드 히스테리시스 전류 제어에 관한 연구)

  • Choi, Won-Kyoung;Choi, Jeong-Hye;Kim, Bum-Sik;Shin, Eun-Chul;Lee, Sang-Bin;Yoo, Ji-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.180-182
    • /
    • 2005
  • The current control using a conventional hysteresis controller of a STATCOM based on two level VSI (Voltage Source Inverter) has high switching frequency and variable modulation frequency. This will increase the switching loss. In addition, the current error is not strictly limited So, in this paper to reduce the switching frequency and to maintain the constant modulation frequency, a novel double band hysteresis current controller based on 3-level VSI is proposed. A conventional hysteresis current control and a novel hysteresis current control was tested with digital simulation and verified the advantage of the novel hysteresis current controller.

  • PDF