• Title/Summary/Keyword: 희석유량법

Search Result 12, Processing Time 0.185 seconds

Investigation for Streamflow Measurement of Small Stream using Dilution Discharge Method during Low Flow Season (갈수기 소하천에서 희석유량법을 이용한 유량측정의 적용성 검토)

  • Kim, Gee Hyeong;Kim, Jeongkon;Lee, Sanguk
    • Journal of Wetlands Research
    • /
    • v.8 no.4
    • /
    • pp.59-67
    • /
    • 2006
  • In this study, dilution discharge method to measure streamflow using water quality data at small streams during low flow season was applied and compared with the conventional method using flowmeter combined with cross-sectional measurement. Streamflow were measured using both methods in Dal-cheon around Naesok Wastewater Treatment Plant located in Boeun, Chugbuk. This stream is reported to suffer from excessive algal growth in spring. An average flowrate difference of $0.004m^3/sec$ was obtained between the two methods. Once further tested for various conditions, the simple water quality method suggested in this study can be used effectively to estimate stream flowrates during low flow seasons where no measuring facilities such as weirs and flowmeters are not available or water depths are too small to measure flow velocities and exact cross-sections.

  • PDF

Discharge Measurement Using Non-Contact Radar Surface Velocity Meter (비접촉식 레이더 표면 유속계를 이용한 유량 측정)

  • Kwon, Sung-Il;Kim, Yong-Jeon;Lee, Chan-Joo;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1841-1844
    • /
    • 2009
  • 일반 하천에서의 유량측정 방법은 하천 조건에 따라 다르다. 전통적인 방법으로는 구조물에 의한 방법, 유속계 측정에 의한 유속-면적법, 부자에 의한 방법, 그리고 희석법 등이 있다. 그러나 이러한 방법들은 측정 위험성을 가지고 있다. 홍수시 발생되는 고유속과 심한 난류, 거대한 부유물질들은 하천 접근에 어려움을 가져오고, 측정 기기의 파손 위험성뿐만 아니라 인명피해까지 발생시킬 가능성이 있다. 최근 기존 방법들의 문제점을 해결하기 위하여 음파, 초음파, 레이더 등을 이용한 유량 측정 방법과 장비들이 개발되었다. 본 연구에서 사용한 레이더 유속계는 하천의 표면유속을 측정하는 비접촉식 센서로 홍수기 전 미리 유속 측정 단면 측량을 실시한다면 홍수시에도 비교적 신속하고 안전하게 유속을 측정할 수 있다. 따라서 본 연구에서는 레이더 유속계를 충청북도 괴산군 달천에 위치한 수전교에 설치하여 괴산댐 방류량 및 동시유량 측정 성과와 비교하였다. 2007년 7월부터 2008년 8월까지 $36m^3/s\;\sim\;821m^3/s$의 사상에서 총 10회 측정한 결과, 레이더 유속계를 사용하여 측정한 유량의 상대오차는 댐방류량 대비 -3.3% $\sim$ 27.5%로 나타나 평균11.8%의 상대오차를 보였다. 레이더 유속계 측정과 동시에 실시한 유속-면적법 측정, ADCP법 측정의 상대오차는 각각 평균 5.7%, 6.5%로 나타난 것과 비교한다면 다소 높은 오차를 보였다. 그러나 측정 시간의 경우 수위에 따라 다소 차이는 있지만 레이더 유속계를 이용하면 30분 정도의 시간이 소요되었으며, 유속면적법은 1시간 이상, ADCP법은 40분의 시간이 소요되었다. 이와 같이 레이더 유속계는 다른 방법에 비해 정확성은 다소 떨어지지만 측정 속도와 안정성 면에서는 우수하다고 판단된다. 문제점으로 지적되는 정확도 측면의 경우 레이더 유속계로 측정되는 표면유 속과 평균 유속 사이의 보정계수 문제를 보완한다면 보다 정확한 측정이 가능할 것으로 판단된다.

  • PDF

The Study on the Production Method of Stepwise Dilution Gas for Odor Analysis with Orifice Tubes (오리피스 튜브에 의한 단계별 냄새 분석용 희석가스의 제조방법에 관한 연구)

  • Kim, Han-Soo;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • This study is to develop the production method of stepwise dilution gas for the evaluation of complex odor concentration by orifice tube. The basic orifice tube for 10 and 30 times of dilution sample was made at first, and with the combination of the basic orifice tubes we can continuously manufacture the stepwise dilution sample gas for air dilution sensory test ; 10, 30, 100, 300, 1,000, 3,000 times etc. The hole size of orifice tube was 0.84 mm for 10 times of dilution sample, and was 0.34 mm for 30 times. Dilution sample gas made with the basic orifice tube have an excellent reproducibility, 2%RSD. In addition, over 90% of correlation was shown between the sample made by the orifice tube and the sample by the syringe dilution method. Because there was no concentration drift of dilution gas with changes of connected pump flow, the basic orifice tube could be mounted directly with a vacuum suction box, and could be used simply as a tool for the evaluation of odor, especially on site.

Effect of the De-NOx Facility Operating Condition on NOx Emission in a 125 MW Wood Pellet Power Plant (125 MW급 우드펠릿 발전소에서 탈질설비 운전조건이 질소산화물 발생량에 미치는 영향)

  • Jeon, Moonsoo;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.18 no.3
    • /
    • pp.52-61
    • /
    • 2022
  • This study tested the effect of de-NOx Facility operating condition on Nox emisiion in a 125 MW wood pellet power plant in Yeongdong Eco Power Plant Unit 1, which is in operation. As SNCR urea flow rate increased, NOx emission gradually decreased, but ammonia slip after SCR increased. The boiler under test has a structure that is unfavorable to SNCR operation due to the high internal temperature, and the optimum location of the nozzle will be required. SCR dilution air temperature change did not affect the amount of NOx generated. Increasing SCR ammonia flow reduced the NOx emission at SCR outlet and also increased the NOx removal efficiency. However, the ammonia flow rate of 111 kg/h, which does not exceed the ammonia slip its own reference limit, is estimated to be the maximum operating standard. The increase in SCR mixer pressure reduced NOx emission and the removal efficiency was also measured to be the most effective variable to inhibit NOx production.

  • PDF

Determination of bromine in 1000 ㎍/g Cl standard solution by ID-ICPMS (동위원소희석 질량분석법에 의한 1000 ㎍/g 염소 표준용액 중 브롬 불순물 분석)

  • Park, Chang Joon;Suh, Jung Kee;Song, Hyun Joo;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The isotope dilution method was used for the determination of Br impurity in $1000{\mu}g/g$ Cl standard solution. Since relatively pure KCl salt was used for the preparation of the Cl standard solution, the Br impurity determination suffers from both spectral and non-spectral interferences due to the presence of a large amount of K and Cl matrices. AG2-X8 anion-exchange resin was employed to separate the Br analyte from the matrices, and RF power was raised to 1500 W and nebulizer gas flow rate was lowered to 0.77 L/min to reduce background from the $ArArH^+$ molecular ions. The Br impurity in the $1000{\mu}g/g$ Cl standard solution was determined to be 43.7 ng/g with the standard addition method. The analytical result was in good agreement with 41.2 ng/g (RSD 1.6%) determined by the isotope dilution method to lower uncertainty from poor reproducibility of the anion-exchange process.

A Study on Electrodeionization for Purification of Primary Coolant of a Nuclear Power Plant (원자력 발전소의 일차 냉각수 정화를 위한 전기탈이온법의 기초연구)

  • Yeon, Kyeong-Ho;Moon, Seung-Hyeon;Jeong, Cheorl-Young;Seo, One-Sun;Chong, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.73-86
    • /
    • 1999
  • The ion-exchange method for the purification of primary coolant has been used broadly in PWR(pressurized water reactor)-type nuclear power plants due to its high decontamination efficiency, simple system, and easy operation. However, its non-selective removal of metal and non-radionuclides shortens its life, resulting in the generation of a large amount of waste ion-exchange resin. In this study, the feasibility of electrodeionization (EDI) was investigated for the purification of primary cooling water using synthetic solutions under various experimental conditions as an alternative method for the ion exchange. The results shows that as the feed flow-rate increased, the removal efficiency increased and the power consumption decreased. The removal rate was observed as a 1000 decontamination factor(DF) at a nearly constant level. For the synthetic solution of 3 ppm TDS (Total Dissolved Solid), the power consumption was 40.3 mWh/L at 2.0 L/min of feed flow rate. The higher removal rate of metal species and lower power consumption were obtained with greater resin volume per diluting compartment. However, the flow rate of the EDI process decreased with the elapsed time because of the hydrodynamic resistivity of resin itself and resin fouling by suspended solids. Thus, the ion-exchange resin was replaced by an ion-conducting spacer in order to overcome the drawback. The system equipped with the ion-conducting spacer resolved the problem of the decreasing flow rate but showed a lower efficiency in terms of the power consumption, the removal rate of metal species and current efficiency. In the repeated batch operation, it was found that the removal efficiency of metal species was stably maintained at DF 1000.

  • PDF

Algal Bioassay for the Treated and Raw Wastewater in the Kyongan Stream (경안천에서 하수처리수와 생하수에 대한 algal bioassay)

  • Lee, Ok-Hee;Hwang, Soon-Jin;Cho, Kyung-Je;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.3 s.95
    • /
    • pp.192-198
    • /
    • 2001
  • The Kyongan Stream and the inlet part of Paltang Reservoir are under significant influence of the effluent of sewage wastewater treatment plant (SWTP) and untreated domestic wastewater (DOW). The fertility of wastewater was evaluated through bioassay using natural phytoplankton population diluted in five levels. The concentrations of $NH_4$, SRP and SRSi were positively correlated with the biomass of phytoplankton. P concentration showed stronger correlation (r = 0.959, p<0.001)than other nutrients. Compared with the initial concentrations, $NH_4$ concentrations in samples from SWTP and DOW decreased 96% and 7%, respectively during the cultivation, and those of SRSi decreased 97% and 60%. However, $NO_3$ concentrations in samples neither showed any particular change nor any increase. Chl-a concentration ranged between $20\;{\mu}g/l$ and $125\;{\mu}g/l$, which maximum value increased up to 83 times. Estimated from the relationship between chl-a and SRP, the P concentration that can maintain the biomass of algae under mesotrophic state (<25\;{mu}g$\;chl-a/l$) was $83\;{mu}g\; P/l$. The volume of flow to maintain this level solely by natural dilution was about $16{\sim}25$ times of in flowing volume in the stream. However, it is not feasible to tap water of such quantity. Therefore, it is imperative to build an advanced sewage wastewater treatment facility that can reduce $NH_4$ and SRP concentrations that promote the growth of phytoplankton in discharged water.

  • PDF

BN 코팅층의 광학 특성에 관한 연구

  • 김경태;이성훈;이건환
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.12-12
    • /
    • 2002
  • hexagonal Boron Nitride (hBN), rhombohedral Boron Nitride (rBN)과 고밀도의 wurzitic Boron N Nitride (wBN), cubic Boron Nitride (cBN) 등의 다양한 상을 갖는 Boron nitride는 그 결정구조에 따라 저밀도, 고밀도 박막으로 분류되며 이중 hBN과 rBN은 층간 결합이 약한 $sp^2$ 결합특성을 가지고, wBN 과 cBN은 강한 $sp^3$ 결합특성을 가지고 있다. 현재까지 $sp^3$결합을 갖는 BN의 우수한 특성을 응용하기 위한 수 많은 연구들이 있어왔다. 특히 cBN은 다이아몬드에 버금가는 높은 경도뿐만 아니라 높은 화 학적 안정성 및 열전도성 등 우수한 물리화학적 특성을 가지고 있어 마찰.마모, 전자, 광학 등의 여러 분야에서의 산업적 응용이 크게 기대되고 있다. 그러나 이와 같이 BN박막의 기계적 물성과 관련한 연 구는 많이 진행되어 왔으나 전기.전자적, 광학적 특성에 관한 연구는 미비한 실정이다. 따라서 본 연구에서는 BN박막의 또 다른 웅용 분야를 탐색하고자 ME - ARE (Magnetically Enhanced A Activated Reactive Evaporation)법 에 의 해 합성 된 BN박막의 광학적 특성 에 관하여 조사하였다. BN박 막합성 은 전자총에 의 해 증발된 보론과 질소.아르곤 플라즈마의 활성 화반응증착(Activated Reactive E Evaporation)에 의해 이루어졌다. 기존의 ARE장치와 달리 열음극(hot cathode)과 양극(anode)사이에 평 행자기장을 부가하여 플라즈마의 증대시켜 반웅효율을 높였다. 합성실험용 모재로는 기본적인 특성 분 석을 위해 p-type으로 도핑된 (100) Si웨이퍼를 $30{\times}40mm$크기로 절단 후, 10%로 희석된 완충불산용액 에 10분간 침적하여 표면의 산화층을 제거한 후 사용하였으며, 광학특성 분석을 위해 $30{\times}30mm$의 glass를 아세톤으로 탈지.세척한 후 사용하였다. 박막합성실험에서 BN의 광학적 특성에 미치는 공정변수의 영향을 파악하기 위하여, 기판바이어스 전압, discharge 전류, $Ar/N_2$가스 유량비 등을 달리하여 증착하였다. 증착된 박막은 FTIR 분석을 통하 여 결정성을 확인하였으며, AFM 분석을 통하여 코팅층의 두께를 측정하였고, UV - VIS spectormeter를 이용하여 투광특성을 평가하였다.

  • PDF

c-BN 박막의 박리특성 향상에 관한 연구

  • 이성훈;변응선;이건환;이구현;이응직;이상로
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.124-124
    • /
    • 2000
  • 다이아몬드에 버금가는 높은 경도뿐만 아니라 높은 화학적 안정성 및 열전도성 등 우수한 물리화학적 특성을 가진 입방정 질화붕소(cubic boron nitride)는 마찰.마모, 전자, 광학 등의 여러 분야에서의 산업적 응용이 크게 기대되는 재료이다. 특히 탄화물형성원소에 대해 안정하여 철계금속의 가공을 위한 공구재료로의 응용 또한 크게 기대된다. 이 때문에 각종의 PVD, CVD 공정을 이용하여 c-BN 박막의 합성에 대한 연구가 광범위하게 진행되어 많은 성공사례들이 보고되고 있다. 그러나 c-BN 박막의 유용성에도 불구하고 아직 실제적인 응용이 이루어지지 못한 것은 c-BN 박막의 증착직후 급격한 박리현상 때문이다. 본 연구에서는 평행자기장을 부가한 ME-ARE(Magnetically Enhanced Activated Reactive Evaporation)법을 이용한 c-BN 박막의 합성에서 적용한 증착공정 인자들의 변화에 따른 박리특성 고찰과 함께 다층박막화 및 제 3원소 혼입 방법을 적용하여 박리특성 향상 정도를 조사하였다. BN 박막합성은 전자총에 의해 증발된 보론과 (질소+아르곤) 플라즈마의 활성화반응증착(Activated Reactive Evaporation)에 의해 이루어졌다. 기존의 ARE 장치와 달리 열음극(got cathode)과 양극(anode) 사이에 평행자기장을 부가하여 플라즈마의 증대시켜 반응효율을 높였다. 합성실험용 모재로는 p-type으로 도핑된 (100) Si웨이퍼를 30$\times$40mmzmrl로 절단 후, 10%로 희석된 완충불산용액에 10분간 침적하여 표면의 산화층을 제거한 후 사용하였다. 박막실험실에서의 주요공정변수는 기판바이어스 전압, discharge 전류, Ar/N2가스유량비이었다. 합성된 박막의 결정성 분석을 FTIR을 이용하였으며, BN 박막의상 및 미세구조관찰을 위해 투과전자현미경(TEM;Philips EM400T) 분석을 병행하였고, 박막의 기계적 물성 평가를 위해 미소경도를 측정하였다. 박리특성의 고찰은 대기중에서의 자발적 박리가 일어나 90%이상의 박리가 진행된 시점까지의 시간을 측정하였고, 증착직후 박막의 잔류응력 변화와 연관하여 고찰해 보았다.

  • PDF

c-BN 박막의 박리현상에 미치는 공정인자의 영향

  • 이성훈;변응선;이건환;이구현;이응직;이상로
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.148-148
    • /
    • 1999
  • 다이아몬드에 버금가는 높은 경도뿐만 아니라 높은 화학적 안정성 및 열전도성 등 우수한 물리화학적 특성을 가진 입방정 질화붕소(cubic Boron Nitride)는 마찰.마모, 전자, 광학 등의 여러 분야에서의 산업적 응용이 크게 기대되는 자료이다. 특히 탄화물형성원소에 대해 안정하여 철계금속의 가공을 위한 공구재료로의 응용 또한 기대되는 재료이다. 특히 탄화물형성원소에 대해 안정하여 철계금속의 가공을 위한 공구재료로의 응용 또한 크게 기대된다. 이 때문에 각종의 PVD, CVD 공정을 이용하여 c-BN 박막의 합성에 대한 연구가 광범위하게 진행되어 많은 성공사례들이 보고되고 있다. 그러나 이러한 c-BN 박막의 유용성에도 불구하고 아직 실제적인 응용이 이루어지지 못한 것은 증착직후 급격한 박리현상을 보이는 c-BN 박막의 밀착력문제때문이다. 본 연구에서는 평행자기장을 부가한 ME-ARE(Magnetically Enhanced Activated Reactive Evaporation)법을 이용하여 c-BN 박막을 합성하고, 합성된 c-BN 박막의 밀착력에 미치는 공정인자의 영향을 규명하여, 급격한 박리현상을 보이는 c-BN 박막의 밀착력 향상을 위한 최적 공정을 도출하고자 하였다. BN 박막 합성은 전자총에 의해 증발된 보론과 (질소+아르곤) 플라즈마의 활성화반응증착(activated reactive evaporation)에 의해 이루어졌다. 기존의 ARE장치와 달리 열음극(hot cathode)과 양극(anode)사이에 평행자기장을 부여하여 플라즈마를 증대시켜 반응효율을 높혔다. 합성실험용 모재로는 p-type으로 도핑된 (100) Si웨이퍼를 30$\times$40 mm크기로 절단 후, 100%로 희석된 완충불산용액에 10분간 침적하여 표면의 산화층을 제거한후 사용하였다. c-BN 박막을 얻기 위한 주요공정변수는 기판바이어스 전압, discharge 전류, Ar/N가스유량비이었다. 증착공정 인자들을 변화시켜 다양한 조건에서 c-BN 박막의 합성하여 밀착력 변화를 조사하였다. 합성된 박막의 결정성 분석을 FTIR을 이용하였으며, Bn 박막의 상 및 미세구조관찰을 위해 투과전자현미경(TEM;Philips EM400T) 분석을 병행하였고, 박막의 기계적 물성 평가를 위해 미소경도를 측정하였다. 증착된 c-BN 박막은 3~10 GPa의 큰 잔류응력으로 인해 증착직후 급격한 박리현상을 보였다. 이의 개선을 위해 증착중 기판바이어스 제어 및 후열처리를 통해 밀착력을 수~수백배 향상시킬 수 있었다. c-BN 박막의 합성을 위해서는 증착중인 박막표면으로 큰 에너지를 갖는 이온의 충돌이 필요하기 때문에 기판 바이어스가 요구되는데, c-BN의 합성단계를 핵생성 단계와 성장 단계로 구분하여 인가한 기판바이어스를 달리하였다. 이 결과 그림 1에서 나타낸 것처럼 c-BN 박막의 핵생성에 필요한 기판바이어스의 50% 정도만을 인가하였을 때 잔류응력은 크게 경감되었으며, 밀착력이 크게 향상되었다.

  • PDF