• Title/Summary/Keyword: 흡수 감쇠

Search Result 145, Processing Time 0.028 seconds

Development and applicability study of customized porcelain packaging technology using 3D printed TPU material (TPU 소재 3D 출력물을 이용한 도자기 맞춤형 포장 기술 개발 및 적용성 연구)

  • Oh Seungjun
    • Conservation Science in Museum
    • /
    • v.31
    • /
    • pp.39-54
    • /
    • 2024
  • We wanted to check The feasibility of substituting the manual ceramic packaging technology with 3D digital technology using cotton pad packaging material was examined. To examine the shock absorption, vibration resistance and compression resistance of 3D packaging material printed out by using TPU material, composite vibration, and packaging compression and drop tests were conducted. As the results of the tests, the 3D packaging material displayed vibration resistance that has been improved by approximately 10~20% based on the damping ratio of the composite vibration test, compression resistance performances that are more than 5 times higher, and shock absorption performance was also improved as the packaged object was not broken in the six-sided drop test. Based on these results, it is determined that it would be possible to secure the reusability of the ceramic packaging materials and simplify packaging techniques, and to present diversity in the packaging materials and packaging technologies.

Influence of Blue-Emission Peak Wavelength on the Reliability of LED Device (청색 피크 파장이 LED 소자에 미치는 영향)

  • Han, S.H.;Kim, Y.J.;Kim, J.H.;Jung, J.Y.;Kim, H.C.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.3
    • /
    • pp.164-170
    • /
    • 2012
  • The dependance of degradation on the blue-peak wavelength is investigated with the blue light-emitting diode (LED) of InGaN/GaN with respect to the optical and the electrical characteristics of the devices. The LED devices emitting the blue-peak wavelength ranging from 437 nm to 452 nm is prepared to be stressed for a long aging time with three different currents of 60 mA, 75 mA and 90 mA, respectively. The degradation of optical intensity is observed with and without phosphor in the devices. The device without phosphor has been degraded significantly as the wavelength of blue-peak is decreased while the optical intensity of LED device with phosphor become less sensitive than that of device without phosphor. The electrical property does not depend on the emission peak wavelength. However, the series-resistance of LED device is slowly increased as the aging time is increased. The deformation of device is observed severely the short wavelength of blue-peak even with the same current since the short wavelength is absorbed substantially at the materials of device during the aging time. Consequently, in order to enhance the lifetime of LED devices, it is important to understand the optical degradation property of the materials against the specific wavelengths emitted from the blue chip.

Latching Control Technology for Improvement of Extracted Power from Wave Energy Converter (파력발전기 추출파워 향상을 위한 래칭 제어기법)

  • Cho, Il Hyoung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.282-290
    • /
    • 2015
  • In this study, a latching control technology, proposed by Sheng et al.(2015), was applied in order to maximize the extraction efficiency of WEC (Wave Energy Converter), which is the heaving buoy coupled with linear electric generator. The latching control is the phase-control technique for improving the wave energy conversion with appropriate latching duration of keeping the buoy fixed. From the time-domain analysis in regular waves, the latching control technology can significantly improve the heave velocity and extracted power, even though the resonance condition is not satisfied. By using the latching control technology, the draft of buoy as well as the required PTO damping force can be significantly reduced along with increased extracted power, which is a big advantage in manufacturing the WEC.

Hydropneumatic Modeling and Dynamic Characteristic Analysis of a Heavy Truck Semi-active Cabin Air Suspension System (대형 트럭 반능동형 캐빈 공기 현가시스템의 유공압 모델링 및 동특성 해석)

  • Lee, Kwang-Heon;Jeong, Heon-Sul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.57-65
    • /
    • 2011
  • In this paper, a hydropneumatic modeling and dynamic analysis of a heavy truck semi-active cabin air suspension system is presented. Semi-active cabin air suspension system improves driver's ride comfort by controlling the damping characteristics in accordance with driving situation. So it can reduce vibration between truck frame and cabin. Semi-active cabin air suspension system is consist of air spring, leveling valve and CDC shock absorber, and full cabin system are mathematically modelled using AMESim software. Simulation results of components and full cabin system are compared with experimental data of components and test results of a cabin using 6 axis simulation table. It is found that the simulation results are in good agreements with test results, and the hydropneumatic model can be used well to predict dynamic characterics of heavy truck semi-active cabin air suspension system.

Performance Analysis of Short Range Inter-Vehicle DS/CDMA Communication System (근거리 차량간 DS/CDMA 통신시스템의 성능 분석)

  • Oh, Se-Kab;Kang, Heau-Joh;Choi, Yong-Surk;Cho, Sung-Joon
    • Journal of Advanced Navigation Technology
    • /
    • v.4 no.2
    • /
    • pp.143-151
    • /
    • 2000
  • In this paper, short range IVC(Inter-Vehicle Communication) channel is modeled in three kinds considering rain attenuation and oxygen absorption. And the performance of DS/CDMA communication system in one path Rician model suitable for platton driving which is the final goal of AVHS(Advanced Vehicle & Highway System) is analyzed. Also, the reflection coefficients in 60 GHz is calculated. For the performance improvement both BCH channel coding and MRC diversity reception technique are adopted. The BER performance is evaluated as a function of packet length, Rician depth and the distance between vehicles.

  • PDF

Seismic Performance of a Hollow Composite Column (강합성 중공 기둥의 내진 성능)

  • Han, Taek Hee;Kim, Jung Hun;Lim, Nam Hyoung;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.215-226
    • /
    • 2008
  • A column test was performed for a hollow composite column to evaluate its seismic performance. The seismic performances of a hollow composite column and a reinforced concrete (RC) column were evaluated and compared by quasi-static tests. Lateral displacements and lateral loads of the column specimens were measured during tests. Ductilities, absorbed energy, equivalent damping ratios, and damage indices were calculated from the recorded data. From the test results, the hollow composite column showed a seismic performance superior to the column in terms of double moment capacity, ultimate energy, and energy absorption.

Particle Monitoring Using Ultrasound in the Gas Flow (초음파를 이용한 기체 유동장내 분진 모니터링)

  • Jhang Kyung-young;Kim Joo-chul;Kim Hong-jun;Hwang Won-ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.78-85
    • /
    • 2004
  • The particle amount monitoring technique using ultrasound is proposed to determine the proper maintenance time of the filter in the supply process of pure gas in the unit of oxygen plant. There are advantages that it is adaptable in high temperature and high pressure, and it is not disturbed by being exposed in the gas flow, and it can be implemented very economically. The applicability of the ultrasonic technique is pre-studied through the theoretical analysis for the dependency of attenuation of ultrasonic wave on the particles in the gas flow. For the purpose, absorption, scattering and dispersion models are considered, and the attenuation by absorption and the change rate of the propagation speed are calculated fur the specific range of particle size and the ultrasonic wave frequency. It was expected by simulation that the absorptive attenuation by particles was the most sensitive to the change of particle amount. The experimental result showed high correspondence with the theoretical expectation so that this ultrasound attenuation measurement was proved to be highly effective for monitoring the amount of floating particles in the gas flow.

Evaluation of Seismic Performance for an Internally Confined Hollow CFT Column (내부 구속 중공 CFT 기둥의 내진 성능 평가)

  • Han, Taek Hee;Kim, Sung Nam;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2007
  • Column tests were performed for a new type of column, the internally confined hollow concrete filled tube column (ICH CFT column), to evaluate its seismic performance. The seismic performances for two types of ICH CFT columns and a general solid RC column were evaluated and compared by quasi-static tests. The displacements and the lateral loads of column specimens were measured during tests. Ductilities, absorbed energy, equivalent damping ratios, damage indices were calculated from recorded data. From the test results, the ICH CFT column shows superior seismic performances with double moment capacity and larger energy absorbing capacity over that of a solid RC column.

항내 정온계산 위한 BOUSS-2D 모형의 반사특성 검토

  • Ha, Chang-Sik;Kim, Tak-Gyeom;Kim, Jong-Hun;Yu, Ha-Sang
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.65-66
    • /
    • 2018
  • 국내 항만의 건설 및 확장 보수를 위한 설계 단계에서의 평면배치 검토시 항내측으로 내습하는 파랑변형특성에 대한 정밀한 평가는 필수적이다. 이에 따라 많은 수학적 모델들이 연안역과 항만에서의 파랑전파와 변형에 대해 개발되어 왔다. 특히 항내정온도의 해석은 항만 사용성 측면에서 매우 중요하며 실제 해상의 파랑상태와 유사한 불규칙파로의 해석이 요구되어 지고 있다. 항내정온도 해석에 있어서 항내파랑장 형성에 크게 영향을 미치는 구조물의 반사율을 효과적으로 적용하는 것은 매우 중요하다. 하지만, 구조물의 반사율은 이론계산이 어렵고, 일반적으로는 모형실험 혹은 현지관측에 의해 추정된다. 따라서, 일반적인 경우 비용 및 시간상의 제약으로 인해 평면 파랑모형으로 정온도 해석시 반사율의 적용은 구조형식별로 연구자들에 의해 개략 제시된 반사율을 적용하고 있다. 특히, 다방향 불규칙파의 적용시에 경계조건으로는 다방향 불규칙파를 효과적으로 제어할 수 있는 부분반사 경계면과 계산영역 밖으로 나가는 파랑에 대해서 인공적인 흡수층 또는 감쇠층(artificial damping layer)을 설정하여 반사를 제어하는 기법을 많이 적용하고 있다. 이때 항만구조물의 부분반사는 파랑제원에 따른 damping layer의 parameter의 조정에 의해 구조물의 구조형식별 반사율을 적절히 재현할 필요성이 있다. 본 연구에서는 불규칙파를 대상으로 damping layer의 parameter(무차원 감쇠계수, 감쇠층의 두께)등의 변화에 따른 반사율의 변화특성을 고찰하고, 향후 부분반사 경계면으로 damping layer가 적용되는 평면 파랑모형의 정온도 해석시 부분반사의 적용에 대한 기초자료를 제공하고자 한다.

  • PDF

Dose Characteristics of Total-Skin Electron-Beam Irradiation with Six-Dual Electron Fields (Six-Dual 전자선 조사면에 의한 전신 피부 조사의 선량 특성)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.337-345
    • /
    • 1998
  • Purpose : To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated Materials and Method : The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of target-skin distance (TSD) and full collimator size (35*35 $cm^2$ on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cm * 105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. Results : The full width at half maximum(FWHM) of dose profile was 130 cm in large field of 105*105 $cm^2$ The width of $100\pm10\%$ of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose unifomity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80$\%$ depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. Conclusion : The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within$\pm10\%$ difference except the protruding area of skin which needs a shield and deeply curvatured region of skin which needs boosting dose.

  • PDF