• Title/Summary/Keyword: 흉부 후.전 방사선검사

Search Result 79, Processing Time 0.021 seconds

Rate of Transformation and Normal Range about Cardiac Size and Cardiothoracic Ratio According to Patient Position and Age at Chest Radiography of Korean Adult Man (한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;Kim, Yun-Min;Jung, Hong-Ryang;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.179-186
    • /
    • 2017
  • Purpose of this study is present the normal range of cardiac size and cardiothoracic ratio according to patient position(chest PA and AP) and age of Korean adult male on digital chest X - ray, And to propose a mutually compatible conversion rate. 1,024 males were eligible for this study, among 1,300 normal chest patients who underwent chest PA and low-dose CT examinations on the same day at the 'S' Hospital Health Examination Center in Seoul From January to December 2014. CS and CTR were measured by Danzer (1919). The mean difference between CS and CTR was statistically significant (p<0.01) in Chest PA (CS 135.48 mm, CTR 43.99%) and Chest AP image (CS 155.96 mm, CTR 51.75%). There was no statistically significant difference between left and right heart in chest PA and AP images (p>0.05). CS showed statistically significant difference between Chest PA (p>0. 05) and Chest AP (p<0.05). The thorax size and CTR were statistically significant (p<0.01) in both age and chest PA and AP. Result of this study, On Chest AP image CS was magnified 15%, CTR was magnified 17% compare with Chest PA image. CS and CTR were about 10% difference by changing posture at all ages.

Analysis of the Influence of Examination Gowns on the Image and the Suitable Fabrics for Chest AP Examinations on DR X-ray Systems (디지털 X-선 시스템에서 흉부 전·후 방향 검사 시 검사복이 영상에 미치는 영향과 적정 검사복 원단의 분석)

  • Eun-Bi Baek;Yoo-Jin Jeong;Su-Bin Lim;Sang-Jo Park;Yeong-Cheol Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.865-872
    • /
    • 2023
  • The purpose of this study was to analyze fabrics suitable for use as examination gowns to determine whether examination gowns affect imaging during anterior to posterior chest examinations(Chest AP) on a digital X-ray system. Examination gowns in use at five medical centers in Seoul were collected and included modal, tencel, cotton, and rayon fabrics. The selection of fabrics was based on studies that reported fabrics with good tactile, absorbent, stretchable, and wrinkle resistance. Phantoms of five hospital gowns and four fabrics, arranged in overlapping layers from one to eight, were created and examined on a digital X-ray system in both Chest AP examination. The images examined were subjected to a first-step profile analysis, a second-step signal intensity averaging analysis, and a third-step microscopic analysis. The results showed that all nine materials had an increasing impact on the image as the number of layers of fabric increased, with the modal fabric having the least impact on the image in the first, second, and third analyses. In conclusion, as the resolution of digital x-ray systems increases, the impact of examination clothing on the image will increase, and research to find suitable materials for examination clothing will continue to be necessary.

Bacteriological Research for the Contamination of Equipment in Chest Radiography (영상의학과 흉부 엑스선 촬영 기기의 세균 오염도)

  • Choi, Seung Gu;Song, Woon Heung;Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.395-401
    • /
    • 2015
  • The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

A Study of Magnification of Cardiac Size and Cardiothoracic Ratio on Chest Posteroanterior Projection in Digital Radiography System (디지털방사선 환경에서 흉부 후.전방향 검사 시 심장과 심흉비 확대에 관한 연구)

  • Joo, Young-Cheol;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.195-196
    • /
    • 2014
  • 현재 디지털방사선 환경으로 변화하고 있는 추세에 과거 필름-스크린 방식에서 사용되던 흉부 후 전 방향 검사 시 초점 영상 수신부 간의 거리가 디지털방식의 장비에도 여전히 적용되고 있다. 이에 본 연구에서는 3개의 DR장비에서 각 영상수용체의 제조특성을 고려하였을 때 실제 심장 및 심흉비의 확대정도에 대해 알아보고, 임상에서 DR 장비를 이용한 Chest PA 검사 시 심장 및 심흉비의 확대도에 대한 정보를 제공하고자 한다.

  • PDF

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

Metastatic Malignant Fibrous Histiocytoma in Lung -One Case Report- (폐로의 전이성 악성 섬유성 조직구종 -1예 보고-)

  • 이석열;이만복;이길노;고은석
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.671-674
    • /
    • 1999
  • At OPD follow-up in December 1998, chest x-ray of a 42-year-old female showed a solit ary pulmonary nodule at a superior basal segment in the right lower lobe. After percut aneous transthoracic needle aspiration failure, wedge resection of the superior basal segment of lower lobe in right lung was performed for diagnosis and therapy. Three years ago, she had received surgery to remove a mass in the left buttock. The mass was pathologically diagnosed as malignant fibrous histiocytoma. She subsequently received 4500 rad radiotherapy for 35 days. Pathology confirmed metastatic malignant fibrous histiocytoma of the lung.

  • PDF

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

New Paradigm for Patients with Pulmonary Nodule Expecting Thoracoscopic Resection (흉강경수술이 예상되는 폐결절 환자에서의 새로운 방침)

  • 조민섭;심성보;왕영필;조건현;서종희;곽문섭;이선희;김학희;문석환
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.748-753
    • /
    • 2003
  • Background: The pulmonary nodules (PN), when indicated, need thoracoscopic resection, especially in cases of non-diagnostic or technically infeasible PCNA (percutaneous needle aspiration). In the difficult situations of small or deeply seated PN, several techniques facilitating thoracoscopy have been used for detecting them. Our new protocol for managing PN was developed and prospectively reviewed. Material and Method: In the procedure of PCNA, we firstly placed the tip of the needle in the center of, or just in contact with PN under CT guidance, and loaded one or two segments of platinum radiomarker inside the needle after removing the stylet. Then, we forced the radiomarker to move to the tip of the needle by pushing the stylet. Finally, if the tip of the needle was not within PN, it was reoriented to the their center to obtain the sample for PCNA. Result: Between May 1999 and May 2000, radiomarkers were successfully placed in 28 PN of 26 patients, with the exception of one. In 18 (85%) of 21 nodules needing throacoscopy, intraoperative fluoroscopy was used to detect them or guide stapling resection during thoracoscopy. Conclusion: The advantages of this technique are that there is that there is no need for further localization for thoracoscopy even in cases of unsuccessful PCNA, and it was more effective in respect to both cost and time. Therefore, this strategy for PN expecting thoracoscopy will be helpful to patients and medical staff alike.

An Effect to the Exposure Index and Entrance Surface Dose according to the Sub-ROI in Chest PA Radiography (흉부 후·전방향 검사 시 보조관심영역의 변화가 노출지수와 입사표면선량에 미치는 영향)

  • Yong-Hui Jang;Ho-Chan An;Han-Yong Kim;Dong-Hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.685-691
    • /
    • 2023
  • This study aims to raise awareness of the exposure index according to the Sub-ROI in clinical use by studying the effect of Sub-ROI's change on exposure index and dose during Chest PA examination. In this study, to examine the changes in EI and ESD according to the Sub-ROI setting, the irradiation conditions were set to 120 kVp, 200 mA, 2 mAs, and the SID was fixed to 180cm. Five types of Sub-ROI were used. The average value of EI according to the Sub-ROI's change was 135.58 ± 0.89 in AEC, 100.80 ± 0.80 in VR, 143.43 ± 0.76 in HR, 103.22 ± 0.68 in LS, and 102.79 ± 0.84 in SS. The mean value of ESD was 30.28±0.50 µGy in AEC, 30.16 ± 0.44 µGy in VR, 30.30 ± 0.46 µGy in HR, 30.23 ± 0.46 µGy in LS, and 30.28 ± 0.51 µGy in SS. As a result of this study, based on the AEC mode recommended by the manufacturer, the VR (25.7%), LS (23.9%), and SS (24.2%) modes decreased, and the HR mode increased by 5.7%. However, ESD was not affected by the Sub-ROI's change. Therefore, Sub-ROI may change EI during the Chest PA examination, it is considered that Sub-ROI should be used appropriately when setting protocols in clinical use.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.