• Title/Summary/Keyword: 휨철근

Search Result 859, Processing Time 0.02 seconds

FE Analysis of the Composite Action in the Composite Beam subjected to the Hogging Moment (부모멘트를 받는 합성보의 전단합성 거동에 대한 유한요소해석)

  • Shin, Hyun-Seop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.4048-4057
    • /
    • 2013
  • In the composite beam subjected to the hogging moment it is very difficult to evaluate the influence of the reduction of slab stiffness due to cracks and their development on the horizontal shear behavior of shear connection. In this study, a 3D FE model is developed by which one can analyze the composite action in the composite beam subjected to the hogging moment. In this FE model, each structural member and shear connection are modeled as similar as possible to details of the composite beam. Bending behaviour, and composite action which could not be analyzed using the existing 1D or 2D FE model are investigated by the 3D model. Analysis results show that the reinforcement ratio and crack behaviour of the slab are main factors which exert a strong influence on the composite action. According to the analysis results about load-slip behavior, initial crack of slab and yielding of rebars have a influence on the slip stiffness of shear connection. The existing experimental results, that the design of partial interaction can be more efficient in designing of shear connection of the composite beams, are indirectly verified by the FE analysis.

Characteristics of Shear Behavior of Reinforced Concrete Beams Strengthened with Near Surface Mounted CFRP Strips (CFRP 스트립 표면매립공법으로 보강된 철근콘크리트 보의 전단거동 특성)

  • Han, Sang Hoon;Hong, Ki Nam;Shin, Byoung Gil;Lim, Jin Mook;Kwak, So Shin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.178-189
    • /
    • 2011
  • Tests and analyses were performed in this study to assess the shear strength of Reinforced Concrete(RC) members strengthened by the Near Surface Mounted(NSM) technique in shear, which is drawing attention as an alternative to the Carbon Fiber Reinforced Polymer(CFRP) bonding strengthening technique. Four-point bending tests were performed on 7 RC specimens without any shear reinforcement. The test variables such as the inclination of CFRP strip (45 degrees and 90 degrees), and the spacing of CFRP strip (250mm, 200mm, 150mm, 100mm) were considered. Through the testing scenarios, the effect of each test variable on the failure mode and the shear strength of the RC members strengthened by the NSM technique in shear were assessed. The test results show that the specimens with CFRP strips at 45 degrees go to failure as a result of the strip fracture, but the specimens with CFRP strips at 90 degrees go to failure as a result of the slip of strips. Strips at 45 degrees was the more effective than strips at 90 degrees, not only in terms of increasing beam shear resistance but also in assuring larger deformation capacity at beam failure. In addition, the RBSN analysis appropriately predicted the crack formation and the load-displacement response of the RC members strengthened by the NSM technique in shear.

Finite Element Analysis of Reinforced Concrete Masonry Infilled Frames with Different Masonry Wall Thickness Subjected to In-plane Loading (채움벽 두께에 따른 철근콘크리트 조적채움벽 골조의 면내하중에 대한 유한요소해석)

  • Kim, Chungman;Yu, Eunjong;Kim, Minjae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.85-93
    • /
    • 2016
  • In this study, finite element analyses of masonry infilled frames using a general purpose FE program, ABAQUS, were conducted. Analysis models consisted of the bare frame, infilled frames with masonry wall thickness of 0.5B and 1.0B, respectively. The masonry walls were constructed using the concrete bricks which were generally used in Korea as infilled wall. The material properties of frames and masonry for the analysis were obtained from material tests. However, four times increased the tensile strength was used for 1.0B wall, which is seemingly due to the differences in locating the bricks. The force-displacement relation and development of crack from the FE analysis were very similar to those from the experiments. From the FEA results, contact force between the frame and masonry, distribution of shear force and bending moments in frame members were analyzed. Obtained contact stress shows a trianglur distribution, and the contact length for 0.5B speciment and 1.0B specimen were close to the value estimated using ASCE 41-06 equation and ASCE 41-13 equation, respectively. Obtained shear force and bending moment distribution seems to replicate actual behavior which originates from the contact stress and gap between the frame and masonry.

Indeterminate Strut-Tie Model and Load Distribution Ratio of Continuous RC Deep Beams (II) Validity Evaluation (연속지지 RC 깊은 보의 부정정 스트럿-타이 모델 및 하중분배율 (II) 적합성 평가)

  • Chae, Hyun-Soo;Kim, Byung-Hun;Yun, Young-Mook
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.13-22
    • /
    • 2011
  • In this study, ultimate strengths of 51 continuous reinforced concrete deep beams were evaluated by the ACI 318M-08's strut-tie model approach implemented with the presented indeterminate strut-tie model and load distribution ratio of the companion paper. The ultimate strengths of the continuous deep beams were also estimated by the shear equations derived based on experimental results, conventional design codes based on experimental and theoretical shear strength models, and current strut-tie model design codes. The validity of the presented strut-tie model and load distribution ratio was examined through the comparison of the strength analysis results classified according to the primary design variables of shear span-to-effective depth ratio, flexural reinforcement ratio, and concrete compressive strength. The present study results of ultimate strengths obtained using the indeterminate strut-tie model and load distribution ratio of the continuous deep beams agree fairly well with those obtained using other approaches. In addition, the present approach reflected the effect of the primary design variables on the ultimate strengths of the continuous deep beams consistently and accurately. Therefore, the present study will help structural designers to conduct rational and practical strut-tie model designs of continuous deep beams.

Creep Behavior of Pultruded Ribbed GFRP Rebar and GFRP Reinforced Concrete Member (인발성형된 이형 GFRP 보강근과 GFRP 보강 콘크리트 부재의 크리프 거동)

  • You, Young-Jun;Park, Young-Hwan;Kim, Hyung-Yeol;Choi, Jin-Won;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.187-194
    • /
    • 2013
  • Fiber reinforced polymer (FRP) has been gathering interest from designers and engineers for its possible usage as a replacement reinforcement of a steel reinforcing bar due to its advantageous characteristics such as high tensile strength, non-corrosive material, etc. Since it is manufactured with various contents ratios, fiber types, and shapes without any general specification, test results for concrete members reinforced with these FRP reinforcing bars could not be systematically used. Moreover, since investigations for FRP reinforced members have mainly focused on short-term behavior, the purpose of this study is to evaluate long-term behaviors of glass FRP (GFRP) reinforcing bar and concrete beams reinforced with GFRP. In this paper, test results of tensile and bond performance of GFRP reinforcing bar and creep behavior are presented. In the creep tests, results showed that 100 years of service time can be secured when sustained load level is below 55% of tensile strength of GFRP reinforcing bar. A modification factor of 0.73 used to calculate long-term deflection of GFRP reinforced beams was acquired from the creep tests for GFRP reinforced concrete beams. It is expected that these test results would give more useful information for design of FRP reinforced members.

Effect of Concrete Strength on Stirrup Effectiveness in Shear Behavior of Concrete Beams (보의 전단거동에서 콘크리트 압축강도가 스터럽 유효성에 미치는 영향)

  • 이영재;서원명;김진근;박찬규
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.6
    • /
    • pp.173-182
    • /
    • 1996
  • An experimental research was carried out to investigate the effect of thc compressive strength of concrete on the stirrup effectiveness in shear behavior of concrete beams. For this purpose. total 24 beams of section dimension of $300{\times}600mm$ were tested: 4 specimens without web reinforcement and 20 specimens with web reinforcement in the form of vertical stirrups. Main variables were two levels(norma1 and high strength) of the compressive strength of concrete and six types of t h e shear rcinfor.cement ratios. Prior to experiment, for given sections and assumed material constants, the reference shear reinforcement ratio(${\rho}_vACI$) which leads to the flexure failure using the provisions of the ACI Building Code(AC1 318-95) was calculated. and the shear reinforcement ratios were relatively selected from the value of ${\rho}_vACI$. From test results, it was shown that thc safety factor of ACI eyuation for p1,ediction of shear strength was decreased with increasing the compressive strength of concrete in beams without stirrups. However. it was observed that as the amount of' stirrup is increased, the safety factor for high strength conci,ete beams with high stirrup ratio is ensured more than that for normal strength concrete beams. Therefore i t appears that the stirrup effectiveness of high strength concrete beams is greater than that of normal strength concrete beams.

An Experimental study on the Structural Performance by the Depth Variation of Capacity of U-shaped composite Beam (U-형 복합보의 춤 변화에 따른 구조성능에 관한 실험적 연구)

  • Ha, Sang-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.111-118
    • /
    • 2020
  • The U-shaped composite beam used in this study consist of a reinforced concrete structure, a beam steel structure supporting the slab, a reinforced concrete structure, and a U-shaped steel plate. The U-shaped composite beam was developed for the purpose of using it as a parking lot because it is highly constructible and has low floor height and long span. For the improvement of constructivity, the U-shaped composite beam ends are planned with standardized H-shaped steel and connected directly to the columns, and the middle of the U-shaped composite beam consists of U-shaped steel plates folded in U-shaped form using thin steel plates (t=6) instead of H-shaped steel. In the middle of the composite beam, where U-shaped steel plates are located, the depth of U-shaped beam may be planned to be small so as to satisfy the height limit of the parking lot. It is important to grasp the structural performance according to the change of depth because low beam depth is advantageous for the reduction of the floor height, but it is a inhibitor to the structural behaviors of U-shaped composite beam. In addition, since U-shaped composite beams are a mixture of steel frame structures, reinforced concrete structures and U-shaped steel plates, securing unity has a great influence on securing structural performance. Therefore, in this study, a structural experiment was conducted to understand the structural performance according to the depth change for U-shaped composite beam. A total of three specimens were planned, including two specimens that changed the depth using a criteria specimen planned for a general parking lot. The results of the experiment showed that the specimens who planned the depth greatly had better structural performance such as yield strength, maximum strength, and energy than the standard specimen.

Monitoring the Structural Behavior of Reinforced RC Slabs Using Optical Fiber-embedded CFRP Sheets (광섬유 매립 CFRP 시트를 활용한 RC 슬래브의 구조적 거동 모니터링 기술 개발)

  • Kim, Jaehwan;Jung, Kyu-San;Kim, Byeong-Cheol;Kim, Kun-Soo;Park, Ki-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.311-322
    • /
    • 2022
  • This study performed 4-point flexural tests of reinforced concrete to which was attached a distributed optical fiber sheet and carbon fiber reinforced polymer (CFRP) sheets in order to assess the effect of the CFRP sheets and the applicability of a BOTDR sensor simultaneously. To evaluate the reinforcing effect, various degrees of CFRP sheet attachment were manufactured, and to evaluate the sensing ability, strains obtained from a BOTDR sensor were compared with strains measured from electric resistance strain gauges that were attached to the concrete surface. From the results, the reinforcing effects were evidently different according to the attachment type of the CFRP sheets, and it was confirmed that the main influencing factor on the reinforcing effect was the type of attachment rather than the attachment area. The reinforced concrete structural behavior was visualized with strains measured from the BOTDR sensor as load increased, and it was identified that load was concentrated in the CFRP reinforced area. Strains from the BOTDR sensor were similar to those from the electric resistance strain gauge; thereby a BOTDR sensor can be effective in the analysis of structural behaviorsof massive infrastructure. Finally, the strain from a BOTDR sensor was high where CFRP sheet fall-off occurs, and it would therefore be efficient to track local damage locations of CFRP sheets by utilizing a BOTDR sensor.

Structural Performance Evaluation of Reinforced Concrete Column Reinforced with Aramid Fibers and PET Fibers (아리미드섬유와 PET섬유시트로 보강한 철근콘크리트 기둥의 구조성능평가)

  • Dong-Hwan Kim;Min-Su Jo;Jin-Hyeung Choi;Woo-Rae Cho;Kil-Hee Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.78-85
    • /
    • 2023
  • This study evaluates the performance of reinforced concrete columns using hybrid fiber sheets for structural behavior. The purpose of this method is to improve the load-bearing capacity of the reinforced structure by impregnating a hybrid fiber sheet, which is woven by arranging aramid and glass fibers uniaxially and attached to an aged concrete structure requiring reinforcement with epoxy. In particular, not only the weight reduction of the material obtained by using a fiber lighter than the steel material, but also the low-strength, high-toughness fiber element among the fibers used delays the brittle fracture of the high-strength, low-toughness fiber element. The low-strength, high-toughness fiber element among the fibers used delays the brittle fracture of the high-strength, low-toughness fiber element, resulting in weight reduction compared to steel. The study conducted structural tests on four specimens, with the hybrid reinforcement method and failure mode as main variables. Specimen size and loading conditions were chosen to be comparable with previous studies. The structural performance of the specimen was evaluated using energy dissipation capacity and ductility. Analysis shows that excellent results can be obtained with the hybrid fiber sheet reinforcement.

Analysis on the Influence of Moment Distribution Shape on the Effective Moment of Inertia of Simply Supported Reinforced Concrete Beams (철근콘크리트 단순보의 유효 단면2차모멘트에 대한 모멘트 분포 형상의 영향 분석)

  • Park, Mi-Young;Kim, Sang-Sik;Lee, Seung-Bae;Kim, Chang-Hyuk;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.93-103
    • /
    • 2009
  • The concept of the effective moment of inertia has been generally used for the deflection estimation of reinforced concrete flexural members. The KCI design code adopted Branson's equation for simple calculation of deflection, in which a representative value of the effective moment of inertia is used for the whole length of a member. However, the code equation for the effective moment of inertia was formulated based on the results of beam tests subjected to uniformly distributed loads, which may not effectively account for those of members under different loading conditions. Therefore, this study aimed to verify the influences of moment shapes resulting from different loading patterns by experiments. Six beams were fabricated and tested in this study, where primary variables were concrete compressive strengths and loading distances from supports, and test results were compared to the code equation and other existing approaches. A method utilizing variational analysis for the deflection estimation has been also proposed, which accounts for the influences of moment shapes to the effective moment of inertia. The test results indicated that the effective moment of inertia was somewhat influenced by the moment shape, and that this influence of moment shape to the effective moment of inertia was not captured by the code equation. Compared to the code equation, the proposed method had smaller variation in the ratios of the test results to the estimated values of beam deflections. Therefore, the proposed method is considered to be a good approach to take into account the influence of moment shape for the estimation of beam deflection, however, the differences between test results and estimated deflections show that more researches are still required to improve its accuracy by modifying the shape function of deflection.