• 제목/요약/키워드: 휨철근

검색결과 859건 처리시간 0.018초

CFS로 보강된 철근콘크리트 보의 휨내력향상효과에 관한 연구 (Improvement of Flexural Capacity of Reinforced Concrete Beams Retrofitted by CFS)

  • 이용택;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.203-211
    • /
    • 1999
  • This study is to examine the feasibility of carbon fiber sheet(CFS), a kind of fiber reinforced plastic(FRP), for a repair and reinforcement of R/C beams. The flexural strength of R/C beams, that were preloaded and then the cracks were repaired, maintains that of the uncracked R/C beams. The flexural strength of R/C beams increases with the reinforcement of CFS. In order to practically apply the repair and reinforcement method, further research is needed for the distribution, amount, and bond of CFS. In this study, an experiment was conducted for R/C beams reinforced with CFS, for various wrapping method and amounts of CFS. Experimental results showed the wrapping method increasing the bond area and amount of CFS layer caused the increase in the strength of the beams. It is found that the strength of CFS should be used as 70% of the maximum strength in retrofitting reinforced concrete beams in evaluating flexural capacity on the basis of ultimate strength design method.

  • PDF

하이브리드 조립형 보강 기법을 적용한 철근콘크리트 보의 휨 성능 평가에 관한 실험적 연구 (An Experimental Study on Flexural Performance of RC Beams Reinforced With Hybrid Prefabricated Retrofit Method)

  • 문상필;이성호;이영학;김민숙
    • 한국공간구조학회논문집
    • /
    • 제20권4호
    • /
    • pp.131-139
    • /
    • 2020
  • In this paper, the hybrid prefabricated retrofit method is suggested and examined. Six specimens were manufactured in order to evaluate their flexural performance of RC beams. Test parameters include the added beam depth, the thickness of bottom plate, the number of the steel plate with openings. The effects of these parameters on the flexural performance of reinforced concrete beams were examined. The load-deflection behavior and modes of cracks are presented from the test results. At the test result, the flexural capacity and the ductility of the hybrid prefabricated retrofit method was increased satbly. Also, comparing the flexural performance of RC beam and retrofitted RC beams, it was increased that the flexural strength is about 3.3 times, the ductility is about 2.55 times, and energy dissipation capacity is about 7.34 times.

인장철근배근량에 따른 U-플랜지 트러스 복합보의 휨 내력에 관한 실험연구 (Experimental Study on the Flexural Capacity of the U-Flanged Truss Hybrid Beam According to Reinforcement Amounts)

  • 오명호;박성진;김영호
    • 한국공간구조학회논문집
    • /
    • 제21권2호
    • /
    • pp.33-40
    • /
    • 2021
  • For the practical application of U-flanged Truss Hybrid beams, the flexural capacity of hybrid beams with end reinforcement details using vertical steel plates was verified. The bending test of U-flanged Truss Hybrid beams was performed using the same top chord under the compressive force, but with the thickness of the bottom plate and the amount of tensile reinforcement. The initial stiffness and maximum load of the specimen with tensile reinforcement have a higher value than that of the specimen without tension reinforcement, but the more tensile reinforcement, the greater the load decrease after the maximum load. In the case of the specimen with tensile reinforcement, because the test result value is 76% to 88% when compared with the flexural strength according to Korea Design Code, the safety of the U-flanged Truss Hybrid beam with the same details of the specimens can't ensure. Therefore, the development of new details is required to ensure that the bottom steel plate and the tensile reinforcement can undergo sufficient tensile deformation.

실험자료를 기반한 국내 원형단면 철근콘크리트 휨교각의 손상수준 별 횡변위비 산정 (Estimation of Drift Ratio by Damage Level for Flexural RC Piers With Circular Cross-Section Based on Experimental Data in Korea)

  • 남현웅;홍기증;김익현
    • 한국지진공학회논문집
    • /
    • 제26권6호
    • /
    • pp.255-265
    • /
    • 2022
  • In order to determine fragility curves, the limit state of piers for each damage level is suggested in this paper based on the previous test results in Korea, including our test results. In previous studies, the quantitative measures for damage levels of piers have been represented by curvature ductility, lateral drift ratio, or displacement ductility. These measures are transformed to lateral drift ratios of piers for consistency, and the transformed values are compared and verified with our push-over test results for flexural RC piers with a circular cross-section. The test specimens are categorized concerning the number of lap-splices in the plastic hinge region and whether seismic design codes are satisfied or not. Based on the collected test results in Korea, including ours, the lateral drift ratio for each pier damage level is suggested.

음향방출 기술을 이용한 철근콘크리트 보의 휨 파괴 손상평가 (Damage Assessment of Reinforced Concrete Beams Under Flexural Failure Mode Using Acoustic Emission Testing)

  • 김다위;이성로;박원석
    • 한국안전학회지
    • /
    • 제38권2호
    • /
    • pp.36-43
    • /
    • 2023
  • In this study, a four-point bending test was conducted to assess and detect the damage to reinforced concrete structures using the acoustic emission (AE) technique. Based on the crack investigation results, flexural failure was classified into four stages and compared with the characteristic analysis results of AE parameters. The parametric characterization indicated that the activity of the primary AE signal was high in the early stage, and that of the second signal increased after the flexural cracks stabilized. Because the secondary AE signal included noise generated by friction, parameter-based analysis for damage assessment was performed using the primary signal; the secondary signal was used as complement. The activity analyses of the primary and secondary signals effectively classified crack propagation; however, determining the macrocracks and yielding of reinforcing bars had certain limitations. Nevertheless, applying the damage index with cumulative AE energy is a complementary technique for detecting and assessing structure damage that well detects the occurrence of macrocracks.

유공강판 전단연결재로 보강된 강관말뚝머리의 구조 성능 평가 (The Structural Performance Evaluation of Steel Pipe Pile Cap with Perfobond Rib Shear Connector)

  • 구현본;김영호;강재윤
    • 대한토목학회논문집
    • /
    • 제28권6A호
    • /
    • pp.843-851
    • /
    • 2008
  • 본 연구에서는 현행 설계기준상의 강관말뚝머리 연결부 결합방법이 갖고 있는 전단키 용접, 철근 배근 및 정착길이 확보 등의 문제점을 개선하고자 결합용 구조 요소로 유공강판 전단연결재(Perforated Flat Shear Connector)를 활용한 새로운 보강방법을 고안하고 이에 대한 구조적 거동 특성을 실험적으로 규명하였다. 실험 결과, 유공강판 전단연결재를 활용한 보강방법은 기존 방법을 대체할 만한 동등 수준 이상의 구조 안전성은 물론 시공성 및 경제성 측면에서도 우수한 성능을 갖는 구조 시스템인 것으로 나타났으며, 이에 따라 효율적인 강관말뚝머리 연결부 보강방법의 하나로 자리매김할 것으로 기대된다.

보-기둥 접합부 비탄성 전단거동을 고려한 5층 철근콘크리트 보통모멘트골조의 비탄성 시간이력해석 (Inelastic Time History Analysis of a 5-Story RC OMRF Considering Inelastic Shear Behavior of Beam-Column Joint)

  • 강석봉;김태용
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.633-641
    • /
    • 2012
  • 이 논문에서는 비탄성 시간이력해석을 통해 보-기둥 접합부 비탄성 전단거동이 구조물 거동에 미치는 영향을 알아보기 위해 지반조건 $S_B$ 내진설계범주 C에 대해서 5층 철근콘크리트 보통모멘트골조를 KBC2009에 맞게 구조설계 하였다. 보 및 기둥 부재의 휨모멘트-곡률 관계는 fiber model로 확인하였으며 보-기둥 접합부 모멘트-회전각 관계는 simple and unified joint shear behavior model과 보-기둥 접합부 모멘트 평형관계를 이용하여 확인하였다. 이력거동은 IDARC 프로그램의 three-parameter model을 활용하여 나타내었다. 2400년 재현주기 수준의 최대지반가속도에 대한 비탄성 시간이력해석 결과 비탄성 보-기둥 접합부를 고려하는 경우 최대밑면전단력은 감소하나 최대지붕층변위, 최대층간변위는 차이가 없었으며 발생한 최대층간변위도 KBC2009의 허용층간변위를 만족하여 구조설계 과정에서 보-기둥 접합부의 비탄성 전단거동을 고려하지 않아도 문제가 없을 것으로 판단된다.

전단 철근 보강된 프리스트레스 PC와 CIP 합성보의 전단강도 (Shear Strength of Prestressed PC-CIP Composite Beams with Vertical Shear Reinforcement)

  • 서정일;박홍근;홍건호;강수민;김철구
    • 콘크리트학회논문집
    • /
    • 제27권4호
    • /
    • pp.399-409
    • /
    • 2015
  • 최근 들어, 모듈화된 건축물에 프리캐스트 콘크리트와 현장콘크리트를 합성한 복합화 공법사용이 증가하고 있다. 일반적으로 프리캐스트 콘크리트 부재는 공장에서 선제작된 PC부재에 휨 전단 성능 향상을 위한 프리텐션 도입이 가능하다. 현행구조 기준에서는 긴장력이 가해진 단일 단면의 전단강도식은 제시하지만, 프리캐스트 콘크리트와 현장 콘크리트 합성 단면의 수직 전단 강도식은 제시하지 못하고 있다. 이전 연구에서는 수직전단 보강이 없는 프리스트레스트 콘크리트와 현장타설 콘크리트 합성보의 전단 강도에 대하여 분석하였다. 따라서 본 연구에서는 수직 전단 보강된 프리스트레스트 콘크리트와 현장타설 콘크리트 합성보의 전단 강도 실험을 통하여 합성보 설계시 고려해야할 사항에 대하여 알아보았다. 변수로는 콘크리트의 면적비, 긴장재의 긴장력, 전단경간비, 그리고 전단철근비를 고려하였다. 실험 결과, 전단 강도는 긴장력이 가해진 단면적의 면적비, 긴장재의 긴장응력에 비례하여 증가하였고 전단 경간비가 증가할수록 감소하였다. 또한 압축대 콘크리트 강도에 따른 전단철근의 기여도 차이를 보였다.

이축방향 유사정적 실험에 의한 이주형 철근콘크리트 원형 교각의 내진 성능평가 (Seismic Performance Assessment of RC Circular Column-Bent Piers Subjected to Bidirectional Quasi-Static Test)

  • 정영수;박창규;이범기;송희원
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.121-128
    • /
    • 2005
  • 본 연구에서는 국내고속도로에서 많이 사용되고 있는 이주형 교각을 주하중방향에 따른 이축지진하중에서의 지진응답을 실험적으로 조사하였다. 실험체는 지름 400mm 높이 2,000mm인 이주형 원형 교각 6기 및 단주형 원형교각 1기를 제작하였으며, $0.1 f_{ck}A_g$ 크기의 축방향 하중작용하에서 횡방향 하중을 주하중방향을 교축방향과 교축방향으로 하여 이축으로 교번반복 재하하였다. 실험변수는 횡구속 철근비와 주하중방향으로 주하중이 교축방향인 실험체는 기존의 단주와 같이 하부에만 소성힌 지부가 발생하는 휨파괴 양상을 나타내었지만 주하중방향이 교축직각방향인 경우 교각의 하단부 뿐만 아니라 교각의 상부에서도 소성힌지가 발생하였으며, 주하중방향이 교축방향인 실험체보다 더 좋은 연성도를 나타내었다.

콘크리트피복 원형충전강관 기둥-강재보 접합부에 대한 반복하중실험 (Cyclic Loading Test for Composite Beam-Column Joints using Circular CEFT Columns)

  • 이호준;박홍근;최인락
    • 한국강구조학회 논문집
    • /
    • 제29권6호
    • /
    • pp.411-422
    • /
    • 2017
  • 본 연구에서는 콘크리트피복 원형충전강관 기둥을 적용한 합성구조 접합부의 거동특성과 내진성능을 평가하기 위하여, 기둥-플랜지 접합부에 대한 인장실험과 보-기둥 접합부에 대한 반복하중 실험을 수행하였다. 기둥-플랜지 인장실험은 피복콘크리트의 유무와 플랜지 폭, 인장철근 보강을 변수로 하여 5개의 실험체에 대하여 하중재하능력과 파괴모드를 분석하였다. 실험결과, 접합부에서의 플랜지 단부 폭을 200mm에서 350mm로 증가시킬 경우 연결부의 강도 및 강성이 각각 1.61배와 1.56배가 증가했고, 인장철근을 보강할 경우 추가적으로 강성과 강도가 각각 1.35배와 1.92배 증가했다. 접합부 반복하중 실험에서는 접합 상세를 변수로 3개의 외부접합부 실험체를 구성했다. 접합부 보강상세로는 인장철근 보강과 강관의 두께, 수직강판 보강을 고려하였다. 모든 접합부 실험체는 보에서 뚜렷한 휨항복이 발생하였으며 접합부의 손상은 제한적이었다. 특히, 강재보가 강관에 직접 용접되는 경우 보의 웨브를 통해서도 하중이 전달되기 때문에, 플랜지 인장실험 결과보다 보수적인 설계가 가능하며, 접합부 강관 두께를 증가시키거나 수직강판으로 보강한 경우에는 추가적으로 패널존의 전단내력이 증가하는 것으로 나타났다.