• Title/Summary/Keyword: 효율성 향상

Search Result 7,940, Processing Time 0.049 seconds

A Study on the Diffusion Factor of e-finance (e-Finance의 확산요인에 관한 연구)

  • Kim, Min-Ho;Song, Chae-Hun;Song, Sun-Yok;Cha, Sun-Kwon
    • International Commerce and Information Review
    • /
    • v.4 no.2
    • /
    • pp.253-277
    • /
    • 2002
  • Nowaday, the advanced technology in information and communication has been leading the dramatic change of transaction paradigm expansion from physical basis to electronic one. As we know, financial services support most of financial exchange between two business parties. So the expansion of electronic transaction paradigm affects to every financial institutions which provide financial services. Thus, financial institutions have accepted e-Finance systems and providing internet financial services to live in the competition. The purpose of this study is to contribute the qualitative enhancement of its customer service, rapid diffusion and accurate strategy establishment for e-Finance industry in the user side. Through the literature review and factor and reliability analysis, this study selects six diffusion factors such as efficiency of perceived e-Finance, reliability and safety of e-Finance in perceived e-Finance itself's characteristic; confidence, technical factors and the customer service quality of e-Finance system in perception on e-Finance System; inclination to innovation in the personal characteristic. According to result of hypothesis verification by using logistics regression analysis, technical factors and the customer service quality of e-Finance system in perception on e-Finance System and inclination to innovation in the personal characteristic gave statistically positive effect to the diffusion decision at the significant level 0.05 and 0.01. However efficiency of perceived e-Finance, reliability and safety of e-Finance in perceived e-Finance itself's characteristic didn't affect to diffusion decision and confidence of e-Finance system in perception on e-Finance System didn't have any statistical significancy. This study can be used as a basic material for the forward empirical study of diffusion factors in the user side and be able to apply to company and government policy making or embodiment, determination for customer service quality degree of financial institutions. But this study has some limitations like didn't touch satisfaction factors and its effect, only deal domestic customers and didn't use multi-regression analysis.

  • PDF

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.

Synthesis of Visible-working Pt-C-TiO2 Photocatalyst for the Degradation of Dye Wastewater (염료폐수 분해를 위한 가시광 감응형 Pt-C-TiO2 광촉매의 합성)

  • Hahn, Mi Sun;Yun, Chang Yeon;Yi, Jongheop
    • Clean Technology
    • /
    • v.11 no.3
    • /
    • pp.123-128
    • /
    • 2005
  • Among various metal oxides semiconductors, $TiO_2$ is the most studied semiconductor for environmental clean-up applications due to its unique ability in photocatalyzing various organic contaminants, its chemical inertness, and nontoxicity. $TiO_2$, however, has a few drawbacks to be solved such as reactivity mainly working under ultraviolet irradiation (${\lambda}$ < 387 nm) and electron - hole recombination on $TiO_2$. In this study, to extend the absorption range of $TiO_2$ into the visible range and enhance electron - hole separation, we synthesized platinum (Pt) deposited $C-TiO_2$. The presence of Pt as an electron sink has been known to snhance the separation of photogenerated electron-hole pairs and induce the thermal decomposition. The characterization of as-synthesized $Pt-C-TiO_2$ was performed by Transmission Electron Microscopic (TEM), the Brunuer-Emmett-Teller (BET) method, X-ray Diffractometer (XRD), UV-vis spectrometer (UV-DRS), and X-ray Photoelectron Spectroscopy (XPS). In order to estimate the photocatalytic activity of the synthesized materials, the photoelectron Spectroscopy (XPS). In order to estimate the photocatalytic activity of the synthesized materials, the photodegradation experiment of an azo dye (Acid Red 44; $C_{10}H_7N=NC_{10}H_3(SO_3Na)_2OH$)was carried out by using an Xe arc lamp (300 W, Oriel). A 420 nm cut-off filter was used for visible light irradiation. From the results, Pt-deposited $C-TiO_2$ showed a far superior phothdegradation activity to Degussa P25, the commercial product under the irradiation of visible light and enhanced photocatalytic activity of visible-working $C-TiO_2$. This is a useful result into the application for the purification system of dye wastewater using visible energy of sun light.

  • PDF

Usefulness of applying Macro for Brain SPECT Processing (Brain SPECT Processing에 있어서 Macro Program 사용의 유용성)

  • Kim, Gye-Hwan;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyeon-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: Diagnostic and functional imaging softwares in Nuclear Medicine have been developed significantly. But, there are some limitations which like take a lot of time. In this article, we introduced that the basic concept of macro to help understanding macro and its application to Brain SPECT processing. We adopted macro software to SPM processing and PACS verify processing of Brain SPECT processing. Materials and Methods: In Brain SPECT, we choose SPM processing and two PACS works which have large portion of a work. SPM is the software package to analyze neuroimaging data. And purpose of SPM is quantitative analysis between groups. Results are made by complicated process such as realignment, normalization, smoothing and mapping. We made this process to be more simple by using macro program. After sending image to PACS, we directly input coordinates of mouse using simple macro program for processes of color mapping, adjustment of gray scale, copy, cut and match. So we compared time for making result by hand with making result by macro program. Finally, we got results by applying times to number of studies in 2007. Results: In 2007, the number of SPM studies were 115 and the number of PACS studies were 834 according to Diamox study. It was taken 10 to 15 minutes for SPM work by hand according to expertness and 5 minutes and a half was uniformly needed using Macro. After applying needed time to the number of studies, we calculated an average time per a year. When using SPM work by hand according to expertness, 1150 to 1725 minutes (19 to 29 hours) were needed and 632 seconds (11 hours) were needed for using Macro. When using PACS work by hand, 2 to 3 minutes were needed and for using Macro, 45 seconds were needed. After applying theses time to the number of studies, when working by hand, 1668 to 2502 minutes (28 to 42 hours) were needed and for using Macro, 625 minutes (10 hours) were needed. Following by these results, it was shown that 1043 to 1877 (17 to 31 hours were saved. Therefore, we could save 45 to 63% for SPM, 62 to 75% for PACS work and 55 to 70% for total brain SPECT processing in 2007. Conclusions: On the basis of the number of studies, there was significant time saved when we applied Macro to brain SPECT processing and also it was shown that even though work is taken a little time, there is a possibility to save lots of time according to the number of studies. It gives time on technologist's side which makes radiological technologist more concentrate for patients and reduce probability of mistake. Appling Macro to brain SPECT processing helps for both of radiological technologists and patients and contribute to improve quality of hospital service.

  • PDF

Effects of Different Levels of Crushed Bamboo Chip on Performance and Carcass Characteristics in Holstein Steers (파쇄 대나무 급여수준이 젖소 거세우의 성장과 도체특성에 미치는 영향)

  • 안병홍;강춘성;추교문;조희웅
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.401-414
    • /
    • 2006
  • Twenty eight Holstein steers 12 months old and weighing about 300kg were andomly allotted into one of four groups being fed ammoniated rice straw(ARS) and substituted 30%, 40% and 50% crushed bamboo chip for ARS to determine the effects of different levels of bamboo chip on performance, digestibility and carcass characteristics. Daily weight gain was reduced as the substitution levels of bamboo chip for ARS as a roughage source increased but there were no differences in daily weight gain between steers fed ARS alone and 30% bamboo chip for ARS. Concentrates intakes were not different between treatments by the substitution levels of bamboo chip for the whole fattening period. Roughage intake tended to increase as the substitution levels of bamboo chip increased. Total feed intake was not affected by the substitution levels of bamboo chip. However, feed efficiency got worse with increasing levels of bamboo chip. Animals fed the roughage substituting 30% bamboo chip for ARS were higher in profit by 13% than animals fed ARS alone as a roughage source. Digestibilities of Dry matter(DDM) and crude fiber(DCF) were highest in animals fed ARS alone as a roughage source. DDM's were lower in higher substitution levels of crushed bamboo chip but there were no differences in DCF among animals fed different levels of bamboo chip as a roughage source. Crude protein digestibility was not affected by ammoniated rice straw or by the different levels of bamboo chip. Dressing percentage and backfat thickness were not affected by ammoniated rice straw or by the levels of bamboo chip but ribeye area was narrowed as the levels of bamboo chip increased. Beef color, fat color, texture, maturity and marbling score were not affected by feeding of ammoniated rice straw or by the levels of bamboo chip. According to these results, it may be concluded that profit can increase when Holstein bulls are castrated and roughage containing ammoniated rice straw plus 30% bamboo chip is offered.

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR) (Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim, Jin-Bae;Kang, Chung-Hwan;Kang, Sung-Jin;Park, Soo-In;Park, Jong-Won;Kim, Yeong-Su;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.64-77
    • /
    • 2002
  • DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

  • PDF

Developing National Science Assessment System:Scientific Knowledge Domain (국가 수준의 과학 지식 평가 체제 개발)

  • Kwon, Jae-Sool;Choi, Byung-Soon;Kim, Chan-Jong
    • Journal of The Korean Association For Science Education
    • /
    • v.18 no.4
    • /
    • pp.601-615
    • /
    • 1998
  • Establishing and evaluating science education policies and revising and monitoring the effectiveness of science curriculum should be based upon the results of systematic and scientific research studies. Advanced nations have already been administering and developing national level science assessments for these purposes. The science assessments administered in Korea have been reported having many limitations and problems, and not succeeded in providing data for science education policy making and curriculum reform. The major purpose of the study is developing national level science knowledge assessment system in order to identify longitudinal trends of elementary and secondary school students science knowledge achievements. The research team consisted of science education experts and teachers from various school levels, decided the directions and major elements of national level science knowledge assessment with the consultation of educational evaluation experts. Item developing ability of the researchers was improved by seminars? and workshops on national assessment in advanced nations and developing skills of writing science items. Nearly 500 items were developed and revised. Pilot test was administered with 958 students at various school levels. 380 items were selected and tested with 8766 students, and the characteristics were analyzed in terms of item response theory. The target populations for national level science knowledge assessment are 5th-grade of elementary school, 2nd-grade of middle school, 1st and 2nd-grade of high school students. The proper period for the assessment is February every year. Multi-stage clustered sampling method is desirable and rotated forms are recommendable for the test format. Bridge items should be introduced to compare the results of multiple tests, and various grades. Anchor items should also be used for longitudinal interpretations of the results. The items for elementary school require low to medium abilities, for middle school and first grade of high school require medium to high abilities and for 2nd-grade of high school high abilities. The discrimination ability of the items developed is high.

  • PDF

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.

Effect of Storage Temperature and Humidity on Water Vapor Permeability of Al-foil Laminate Paper (저장온도(貯藏溫度) 및 습도(濕度)가 알루미늄박(箔) 적층지(積層紙)의 수분투과율(水分透過率)에 미치는 영향(影響))

  • Park, Kil-Dong;Choi, Jin-Ho;Sung, Hyun-Soon;Hong, Soon-Keun
    • Korean Journal of Food Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.314-318
    • /
    • 1981
  • In order to improve the storage stability of spray and freeze dried red ginseng extract powder packed in a bottle, the water vapor permeability of Al-foil laminate paper used for cap closure and shelf life of those products on various storage temperatures and relative humidities were investigated. The thickness of the laminate paper was $93{\pm}3\:{\mu}m$ and its physical properties were equal to standard of ASTM (B-377-66) The absorption rate of the freeze dried powder was 2-6 times greater than that of the spray dried powder at $37^{\circ}C$. Therefore it was considered that the laminate could be used for cap closures for the spray dried powder but unsuitable for the freeze dried powder. The shelf life of the spray dried powder was longer than that of the freeze-dried powder at $37^{\circ}C$.

  • PDF

Effects of Dietary Probiotic Complex on Growth Performance, Blood Immunological Parameters and Fecal Malodor Gas Emission in Growing Pigs (복합 생균제 첨가가 육성돈의 생산성, 면역관련 혈액학적 지표 및 분내 유해가스 발생에 미치는 영향)

  • Jang, H.D.;Kim, H.J.;Cho, J.H.;Chen, Y.G.;Yoo, J.S.;Kim, I.H.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.501-508
    • /
    • 2007
  • This study was conducted to evaluate effect of probiotic complex(Lactobacillus acidophilus, Bacillus subtilis and Aspergillus oryzae) on growth performance, blood immunological parameters and fecal malodor gas emissions in growing pigs. Forty-eight pigs[(Landrace × Yorkshire) × Duroc, 25.31±1.29kg average initial body weight] were used in 35d growth trial. Dietary treatments included CON(basal diet), PC1(basal diet + 0.1% probiotic complex) and PC2(basal diet + 0.2% probiotic complex). From d 0 to 20, ADFI was significantly increased in PC1 and PC2 compared to CON(Linear effect, P=0.013). From d 21 to 35, ADFI was increased in PC1 compared to CON(Quadratic effect, P=0.024). For the whole period, ADFI was increased PC2 and PC1 compared to CON(Linear effect, P=0.009, Quadratic effect, P=0.004). For the whole period, ADG was increased in PC1 compared to CON(Quadratic effect, P=0.017). G/F was not affected by treatments. Dry matter digestibility in PC2 was higher than PC1 and CON(Linear effect, P=0.001). Nitrogen digestibility was significantly higher in PC2 and PC1 than CON(Linear effect, P=0.005). In blood immunological parameters, Total protein, IgG, red blood cell(RBC) and white blood cell(WBC) were increased in PC2 compared to PC1 and CON(Linear effect, P<0.001, Quadratic effect, P<0.001). In fecal malodor gas emission, ammonia and acetic acid were significantly reduced in PC2 compared to CON(Linear effect, P<0.02). Hydrogen sulfide was significantly reduced in PC2 compared to CON(Linear effect, P=0.0002, Quadratic effect, P=0.018). However, total mercaptans was not affected by treatments. Water content of feces was not significantly different among the treatments. In conclusion, 0.2 % probiotic complex improved ADFI, apparent dry matter and nitrogen digestibility, Total protein, IgG, RBC and WBC. Also, it decreased ammonia, acetic acid and hydrogen sulfide emissions in growing pigs.