• Title/Summary/Keyword: 효과측정

Search Result 15,467, Processing Time 0.044 seconds

A Meta-Analytic Review of Effects of Brain-Based Education (뇌기반 교육의 효과에 대한 메타분석)

  • Jang, Hwan Young;Jang, Bong Seok
    • Journal of Practical Engineering Education
    • /
    • v.12 no.1
    • /
    • pp.41-47
    • /
    • 2020
  • This study aims to investigate effects of brain-based learning. 27 primary studies were selected through rigorous search process and analyzed through meta-analytic methods. Research findings are as follows. First, the total effect size was .67. Second, the effect of dependent variables was academic achievement, cognitive domain, and affective domain in order. Third, with respect to types of cognitive domain, the effect was self-regulation, creativity, competence, communication, and research ability in order. Fourth, the effect of affective domains was sociality, learning interest, and subject attitude in order. Fifth, regarding development of cognitive ability, the effect size was combined, brain training, learning environments, and right brain activities in order. Sixth, the effect of learning activities was memory improvement and attention enhancement in order.

MEASUREMENTS OF FREQUENCY SHIFT DUE TO POLARIZATION ANISOTROPY AND FREQUENCY PULLING EFFECT (레이저반사경의 비등방평과 주파수 당김효과에 의한 발진 주파수 편이 측정)

  • 서호성
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.182-184
    • /
    • 1990
  • 633M He-Ne 레이저의 반사경의 비등방성에 의한 발진 주파수 편이 및 레이저 매질의 분산특성 때문에 기인하는 레이저 주파수 당김효과를 측정하였다. 내부 반사경형 레이저 공진기에서 발진하는 종모드사이의 맥놀이 신호를 RF-스펙트럼 분석기로 분석하므로써 90kHz의 주파수 편이량차를 측정하였다.

  • PDF

유산균의 항산화 효과

  • Choe, Seung-Ho;Yang, Hui-Jin;Lee, Su-Won
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.294-296
    • /
    • 2005
  • Lactobacillus 및 Streptococcus 속의 유산균을 사용하여 유산균이 가지는 항산화 효과를 측정하였다. DPPH 법을 사용하여 전자공여능을 측정한 결과, L. casei가 43.54%로 가장 높았으며 L. acidophilus는 33.43%, 그리고 S. thermophilus가 7.1%로 가장 낮은 항산화 효과를 나타내었다. 유산균 파쇄액의 SOD 유사활성은 L. acidophilus가 15.68%, L. casei는 19.86%, S. thermophilus는 49.3%로 전자공여능의 측정 결과와는 달리 S. thermophilus가 가장 뛰어난 SOD 유사활성을 나타내었다.

  • PDF

Development of Digital Filter and Damper for Improving Accuracy of Measurement of Application Amount of Disinfectants of Disinfection Vehicle (방역차량의 약제 살포량 측정 정확성 개선을 위한 디지털 필터와 댐퍼 개발)

  • Baek, Seunghwan;Park, Donghyeok;Park, Hana;Lee, Chungu;Rhee, Joongyong
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.148-148
    • /
    • 2017
  • 방역 차량의 약액탱크, 차량의 연료, 워셔액 등의 탱크 내부에는 잔존량을 측정하기 위해 기둥과 floating box로 이루어진 부력식 수위레벨센서가 사용되고 있으나 액체레벨에 따라 float이 상하로 움직이는 측정원리상 차량 주행 중 정확성이 매우 떨어진다(Park et al. 2016). 방역차량이 주행 중 분사할 때, 슬로싱 현상과 방역소독기의 노즐과 펌프에서 발생하는 진동으로 인해 기존의 부력식 센서를 이용한 약제 살포량 측정방법은 정확성이 매우 떨어지는 경향이 있다. 본 연구의 목적은 방역차량이 주행하면서 분사할 때, 수위레벨 센서를 이용한 약제살포량 측정의 정확성을 개선하는 것으로 디지털 칼만필터, Low pass filter와 댐퍼를 제작하여 이용했다. 본 연구에서는 압력식 레벨센서를 이용해 약액탱크의 높이당 단면적과 수위를 측정하여 약제살포량을 계산했다. Python 2.7을 이용해 디지털 칼만필터와 Low pass filter(LPF)를 구현하였으며 3D프린터를 이용해 댐퍼를 제작했다. 실내에서 슬로싱 현상을 인공적으로 만들어 필터와 댐퍼의 수위 측정 정확성 개선효과를 확인 후 실제 방역차량에 부착하여 비포장도로에서 주행하면서 분사할 때 필터와 댐퍼의 효과를 확인하였다. 댐퍼의 공극률(p)을 바꿔가며 수위 측정 정확성 개선효과를 확인하였다. 실내, 현장 실험 결과, 칼만필터가 LPF보다 개선효과가 더 크지만 데이터 50개 처리에 1.71초의 시간지연이 발생했다. 댐퍼는 수위센서를 고정시키고 유체의 운동을 방해하여 이상치와 큰 오차제거에 효과적이었다. 칼만필터와 댐퍼를 동시에 이용할 경우, 수위 측정정확성 $R^2$는 0.9985, 0.9981로 ${\pm}4.3cm$의 범위내에서 수위를 측정할 수 있었다. 필터의 시간지연과 수위 측정정확성을 고려하여 데이터 기록간격을 3초로 설정하면 ${\pm}3cm$이내에서 약탱크 내 수위를 측정할 수 있었다. 공극률(p)가 0.294, 0.291, 0.17에서 측정정확성 $R^2$는 각각 0.9897, 0.9858, 0.9872 로 p가 0.294에서 개선효과가 가장 좋았으나 개선효과의 차이는 크지 않았다.

  • PDF

A Study on Developing and Applying a Tool for Measuring Achievements of Reading Programs for Children (어린이 독서프로그램의 성과 측정 도구 개발과 적용에 관한 연구)

  • Choi, Yoon Kyung;Chung, Yeon Kyoung
    • Journal of the Korean Society for information Management
    • /
    • v.31 no.1
    • /
    • pp.7-29
    • /
    • 2014
  • The purpose of this study was to develop and evaluate a measuring scale for the effect of reading programs for children. First, in literature review, the effects and children's reading programs performance scales were analyzed, and then independent variables, dependent variables, and control variables for children's reading achievements were defined. Second, survey questionnaires for children, librarians, program instructors, and heads of child centers were designed to measure dependent variables and control variables on the scale. Third, the questionnaires for children were distributed to 10 public libraries participating in <2013 The Reading with Library> programs for two times in the early and the late time of the programs. Also, the survey questionnaires of 30 librarians, program instructors, and heads of the child centers were carried. Finally, all of the data were collected and analyzed in time series, and the improvements for the scale were proposed.

A Study on the Measurement of Tissue Blood Flow by the Self-Mixing Effect of Laser Diode (레이저 다이오드의 자기혼합 효과를 이용한 조직혈류 측정에 관한 연구)

  • Ko, Ran-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 1994
  • This paper describes the measurement of tissue blood flow by the the self-mixing effect of laser diode. A Laser doppler signals due to the moving object and the tissue blood flow were detected by the self-mixing effect of laser diode. The Doppler shifted frequency was changed linearly with the driving frequency of moving object and was increase after the exercise. The results of in-vivo experiment were consistent with the result of exercise physiology.

  • PDF

Speed estimation of sound-emitted objects through convergence of sound information analysis and smart device technology (음향 정보 분석과 스마트 기기 기술의 융합을 통한 사물의 속력 측정)

  • Nam, Yong-Wook;Kim, Yong-Hyuk
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.233-240
    • /
    • 2015
  • In this paper, we present an algorithm that estimates the speed of a moving object only using its sound information. In general, the speed gun projects the incident light onto a moving object and measures the frequency variation of the scattered light. Then the speed is measured by this frequency difference. In our study, instead of light information, we measure the speed by sound frequency difference when the object is coming and moving away. In our experiments on the speed measurement, on average the error of 6.08% was obtained. Utilizing this algorithm for smart device, we can measure the speed of a moving object without sensor that measures the frequency of the light.

Development of Measures of Information Security Policy Effectiveness To Maximize the Convergence Security (융합보안 강화를 위한 정보보안 정책 효과성 측정도구 개발)

  • Yim, Myung-Seong
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.4
    • /
    • pp.27-32
    • /
    • 2014
  • The information security policy is one of the most important tools for organization to manage the implementation and ensure the organizational security. However, we do not have metrics for measuring its effectiveness. The ultimate purpose of this study is to develop the measures of information security policy effectiveness. To do this, this study review data quality and information quality literatures and investigate appropriate subfactors for information security policy. Rooted in these concepts, we suggest accuracy, completeness, interpretability, and relevance from content aspect and understandability, concise representation, and amount from form aspect as factors for information security policy effectiveness.

A Measurement Algorithm for the Cornea Curvature in Automatic Refracto-Keratometer (자동 시각 굴절력 곡률계의 각막 곡률 측정 알고리즘)

  • Sung, Won;Park, Jong-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.517-519
    • /
    • 2002
  • 본 논문은 자동 시각 굴절력 곡률계의 전자 부문에 연동될 곡률 측정 알고리즘을 소개한다. 만약 자동화된 시스템이 광학계로부터 나오는 영상을 이용하여 내부 처리를 거친 후 정확 시각 측정치를 검사자에게 알려줄 수 있다면 잘못 측정되는 측정 횟수를 크게 줄일 수 있을 것이다. 본 연구는 형태학적 필터링(morphological filtering)과 그레이-레벨의 신호 강조(signal enhance) 기술들을 이용하여 자동시각 굴절력 곡률계에 연동될 각막 곡률 측정 알고리즘을 개발하였다. 알고리즘에서는 광학계로부터 도출된 링 모양 광원의 화상을 처리하기 위해서 새로운 방법을 사용하는 대신에 굴절력 측정을 위해서 6개의 점으로 구성된 화상을 처리하는 방식으로 변형 적용시킨다. 이 때 링의 띠를 6개의 덩어리점으로 변형하는 과정만을 제외하면 굴절력 화상을 처리하는 방식과 같게 된다. 이는 알고리즘의 간결화와 측정 시간을 줄이는 효과를 얻게 된다. 그리하여 본 각막 곡률 측정 알고리즘은 정한 측정 값 도출이 어려운 시각 영상에 적용되어 효과적으로 오차를 줄임으로써 보다 효율적인 시각 측정을 가능하게 하였다.

  • PDF

A Study on Validation of the Shielding Effectiveness Measurement Method of the Concrete Containing Electric Arc Furnace Oxidizing Slag (전기로산화슬래그를 활용한 콘크리트의 차폐효과 측정 방법의 유효성 검증 연구)

  • Jang, Hong-Je;Lee, Han-Hee;Choi, Hyo-Sik;Song, Tae-Seung;Cho, Won-Seo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.478-482
    • /
    • 2021
  • In this paper, methods for manufacturing shielding concrete by recycling steelmaking slag discarded as industrial waste and measuring the shielding effectiveness of the shielding concrete were studied. By comparing the result of shielding effectiveness measurement of this concrete block with shielding effectiveness measurement of the structure constructed with this concrete, the measurement system for measuring shielding effectiveness of the concrete block was verified. The size of the concrete stru ctu re is 2.9 × 2.9 × 3.4m and the concrete block is 0.3 × 0.3 × 0.2m. The frequ ency band u sed for mesu rement is 600MHz - 2GHz, the types of concrete u sed to measu re the shielding effectiveness are general concrete and concrete containing electric arc furnace oxidizing slag. In the case of the concrete structure, reinforcing rebars are installed at intervals of 15cm for stru ctu ral safety, as the frequ ency increase, the electromagnetic wave properties of rebars gradu ally decreased, there was a slight difference in the measurement results. In conclusion, the measurement result of shielding effectiveness of the concrete block is similar to the result of the concrete structure. It is thought that it can be sufficiently utilized for electromagnetic wave engineering design, and the concrete shielding effectiveness measurement system using standard specimens was verified.