• 제목/요약/키워드: 홴성능

검색결과 62건 처리시간 0.022초

덕트가 있는 축류홴의 유동 및 음향장 해석 (An Analysis of the Flow and Sound Field of a Ducted Axial Fan)

  • 전완호;정기훈;이덕주
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.15-23
    • /
    • 2000
  • The present work describes the prediction method for the unsteady flow field and the acoustic pressure field of a ducted axial fan. The prediction method is comprised of time-marching free-wake method, acoustic analogy, and the Kirchhoff-Helmholtz BEM. The predicted sound signal of a rotor is similar to the experiment one. We assume that the rotor rotates with a constant angular velocity and the flow field around the rotor is incompressible and inviscid. Then, a time-marching free-wake method is used to model the fan and to calculate the flow field. The force of each element on the blade is calculated by the unsteady Bernoulli equation. Lowson's method is used to predict the acoustic source. The newly developed Helmholtz-Kirchhoff BEM lot thin body is used to calculate tile sound field of the ducted fan. The ducted fan with 6 blades is analysed and the sound field around the duct is calculated.

  • PDF

에어컨 용 횡단류 홴의 특정 주파수 소음 성분의 저감 대책에 관한 연구 -날개의 랜덤 배열과 경사진 스태빌라이저에 대한 연구- (A Study on the Reduction of Discrete Frequency Tones of a Cross-Flow Fan of Air-Conditioners -Studies on the Random Distribution of Fan Blades and the Skewed Stabilizers-)

  • 구형모
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.870-878
    • /
    • 1998
  • The cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll casing is widely used in many air-ventilating and air-conditioning devices. Its ooperating points of high efficiency and loading conditions frequently induce a annoying sharp tonal component of discrete frequency on the noise spectrum, which is open called as a BPF(Blade-Passing-Frequency) noise and degrades the sound quality of the devices. this BPF tone has been one of the defects of the cross-flow fan. This study proposes two methods in order to reduce this tonal noise component, which are the random distributions of the fan blades and the skewed shapes of the stabilizer. The proposed methods are verified by a simple analytical model and are applied in manufacturing the cross-flow fan and the stabilizer samples. Some experiments are carried out to verify the reduction capability of BPF tones of above two schemes and the experimental results are analyzed. The comparison between two method is also carried out.

  • PDF

운전점이 다른 소형 축류홴의 난류 유동장 고찰 (Investigation on the Turbulent Flow-Field of a Small-size Axial Fan with Different Operating Points)

  • 김장권
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.40-47
    • /
    • 2008
  • The turbulent flow characteristics around a small-size axial fan(SSAF) for a refrigerator are strongly dependent upon the operating points. Four operating points such as $\phi$ =0.1, 0.18, 0.25 and 0.32 were adopted in this study to investigate three-dimensional turbulent flow characteristics around the SSAF by using a fiber-optic type Laser Doppler Anemometer(LDA) system. Downstream mean velocity profiles of the SSAF along the radial distance show that axial and tangential velocity components exist predominantly, except $\phi$ = 0.1, and have a maximum value at $r/R{\fallingdotseq}0.8$, but radial velocity component having a relatively small value only turns flow direction to the outside or the central part of the SSAF. The turbulent intensity shows that the radial component exists most greatly after $r/R{\fallingdotseq}0.5$. Downstream turbulent kinetic energy at $\phi$ = 0.25 and 0.32 together has the largest peak value at $r/R{\fallingdotseq}0.9$.

  • PDF

축류형 홴 성능 및 소음에 영향을 미치는 설계변수 분석 (Design Parameter Analysis on the Performance and Noise of Axial Fan)

  • 김기황;이승배;주재만
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.275-281
    • /
    • 2001
  • While basic input parameters for the performance and noise of axial fan are flow rate, pressure rise, rotating speed, and fan diameter, the geometric parameters of blade are sweep angle, solidity, and camber angle. The sweep angle does not affect fan performance much, but on fan noise significantly. Solidity and camber angle are very critical design parameters acting on the fan performance directly. The solidity and camber angle are closely related, therefore they have to be carefully determined for the low-noise and high-performance fan. In This paper, different design points are selceted and also geometric parameters are deliberately changed for the comparison of fan noise. As a result, at the same performance, the input rotational speed affects radiated noise more significantly than others. When solidity and camber angle are increased more than those by iDesignFan/sup TM/ program, more noise is experienced. The blade sweep method and blade numbers at same solidity are observed to results in different levels of performance and noise.

  • PDF

축류 마이크로 홴의 전산해석 및 성능시험 (A Numerical Analysis and Experiment for Micro-Fans)

  • 조진수;변태균;박왕식;전창근
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

원심 전향익 송풍기 제품규격 KS B 6326의 개정 해설 (Revision of Forward Curved Bladed fans: KS B 6326)

  • 이승배;김회룡;김광용;정근화
    • 한국유체기계학회 논문집
    • /
    • 제4권1호
    • /
    • pp.46-51
    • /
    • 2001
  • The revision is proposed for forward curved bladed fans in order to make the KS B 6326 established in 1987 in agreements with newly revised KS standards. This proposal includes modification of Aplication range, numbering system, classification based on performance, and allowing dimensions for specified sizes.

  • PDF

원심 전향익 송풍기 제품규격 KS B 6326의 개정 (Revision of Forward Curved Bladed Fans: KS B 6326)

  • 이승배;김회룡;김광용;정근화
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.104-109
    • /
    • 2000
  • The revision was proposed for forward curved bladed fans in order to make the KS B 6326 established in In in agreements with newly revised KS standards. This proposal includes modification of Application range, numbering system classification based on performance, and allowing dimensions for specified sizes.

  • PDF

단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측 (Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet)

  • 김명호;김병재
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.892-897
    • /
    • 2020
  • 본 연구에서는 간접식 증발냉각 장치의 냉각 성능을 예측하고 다양한 공기 유량 및 물 분무 유량 조건을 만족하는 성능 상관식을 제안한다. 기존의 플라스틱 열교환기는 공조 공간의 크기에 따라 금형을 새로 제작해야 하기 때문에 높은 효율에도 불구하고 잘 사용하지 않았다. 한편 단프라시트는 일반적으로 두께가 얇아 열교환이 우수하고, 특히 제작이 매우 용이하다. 따라서 열교환기를 단프라시트로 제작할 경우 금형이 별도로 필요하지 않아 열교환기 제작 비용을 크게 절감할 수 있다. 이에 본 연구에서는 단프라시트로 다채널 열교환기를 제작하여 간접식 증발냉각 장치를 제작하였다. 성능 실험장치는 열교환기, 물 분사 노즐, 터보홴, 항온조, 순환 펌프, 온도 센서, 습도 센서, 차압식 유량계 및 자료획득 장치로 구성하였다. 증발냉각 시 공기 유량이 증가하면 유용도가 감소하였고, 수공비에 따라 유용도 최적점이 존재하였다. 등온 조건에서 냉각 성능을 예측하는 상관식과 실내 환기 온도와 외기 상태를 반영하는 성능 상관식을 제안하였다. 상관식들의 냉각 성능 오차는 4 % 이내였다.

차량용 MR 홴 클러치의 제어성능 평가 : 실험적 고찰 (Control Performance Evaluation of MR Fan Clutch for Automotive : Experimental Investigation)

  • 김은석;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.500-505
    • /
    • 2009
  • This paper presents temperature control of engine cooling system using a controllable magnetorheological (MR) fan clutch. An appropriate size of MR fan clutch is devised and modeled on the basis of Bingham model. Subsequently, an optimization to determine design parameters such as width of housing is undertaken by choosing the reciprocal of the controllable torque as an objective function. Under consideration of spatial limitation, design parameters are optimally determined using finite element analysis. A sliding mode controller is then designed to control the angular velocity of the MR fan clutch using experimentally determined parameters. The designed controller is experimentally implemented and control performances of the MR fan clutch system are evaluated.

  • PDF