• Title/Summary/Keyword: 환자피폭선량

Search Result 446, Processing Time 0.027 seconds

The Study of Optimal Acquisition Condition and Image Processing (최적의 촬영조건 및 영상처리에 관한 연구)

  • Lee, Yong-Gu;Shin, Jong-Ho;Seo, Kyoung-Eun;Choi, Yoo-Lee;Lee, Soo-Hyeon;Lee, Young-Jin;Kim, Hee-Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.221-226
    • /
    • 2014
  • In this paper, we achieved the study which determined the excellent diagnostic condition and searched the exposure condition with the minimum radiation exposure level having the equal diagnostic ability. To accomplish these study, chest phantom images with lesions and without ones were evaluated at various exposure conditions. With respect to the phantom with lesions and without ones, we obtained the chest PA imaging applied by photographing parts of DR apparatus and the images processed as histogram equalization and edge enhancement method. The images were acquired at the exposure conditions of 2.0, 2.5, 3.2, 4.0 and 5.0mAs. The morphological analysis was performed by ROC curves using the images obtained at each exposure condition. The exposure conditions with the most excellent diagnostic ability and with the equal diagnostic capability having the minimum radiation exposure level were determined by means of sensitivity, specificity and accuracy.

Effectiveness Evaluation of the Tube Voltage Measurement by using Additional Filter (부가필터를 이용한 kVp 측정의 실효성 평가)

  • Hwang, Jun-Ho;Lee, Kyung-Ho;Choi, Yoon-Bong;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.355-363
    • /
    • 2015
  • Advancement in the medical field provides an opportunity for the development of medical equipment and also enable accurate diagnosis for the inspection and the treatment of diseases. The aging of equipment due to the frequent operation produce uncertainty in the patient exposure dose, so a quality control was implemented by establishing a safety management system on a regular basis. The x-ray tube voltage (kVp), which is directly involved in the patient exposure dose and the life of the equipment, needs periodic performance for the quality control, but it has a limitation due to the time and the cost. In this study, we proposed a new method for measuring the kVp with ease by using the Y and Cu to solve the problem of the time and cost. We also evaluated the usefulness and the effectiveness of the new method and its accuracy through the kVp measurement. After securing the condition, the amount of the tube current and evaluating the usefulness and effectiveness of kVp measured using Y and Cu. The density range used was at 0.5-1.0, kVp was in the range of ${\pm}10%$, then, we recorded the change in concentration as % of Y and Cu. This experiment showed that when Cu and Y was at 75 kVp, concentration was the same, and when the kVp was changed to 65 ~ 85 %, a gradual increase in concentration to 85 ~ 110 % was noted.

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

Image Evaluation of Projection Method in Chest Radiography (흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • In this study, images taken using a grid and images taken using Air Gap Technique were evaluated in X-ray chest radiography. Subjective Evaluation The ROC (Receiver Operating Characteristic) evaluation was evaluated by 5 radiologists who had worked for more than 10 years in the radiology department of a university hospital. Objective evaluation SNR (Signal to noise ratio) was evaluated. As a result of the analysis, the Cronbach Alpha value was 0.714, which was significantly higher. In the Air Gap Technique, the distance between the phantom and the subject was set at 20 cm, and the image was taken with a tube voltage of 100 kVp, a tube current and a recording time of 8 mAs. In the ROC (Receiver Operating Characteristic) evaluation, the highest score was obtained with 18 score and an objective evaluation SNR (signal to noise ratio) of 6,149 scored. Also, in the imaging method using a grid, when the distance between the phantom and the constant receptor is 15 cm apart, and the tube voltage is 110 kVp, the tube current and the recording time are taken at 8 mAs, the ROC evaluation score is 19 and the objective evaluation SNR (Signal to noise ratio) is the highest with 6.622 scored. Therefore, if the Air Gap Technique imaging method is used, which overcomes the shortcomings such as delay in reading, increase in patient's exposure dose, and shortening of mechanical lifespan, as well as re-radiography due to the cut-off phenomenon of the grid that appears using the grid, the It is thought that it will be very helpful for chest imaging, including the case of using a portable X-ray imaging device.

Evaluation of the dose distribution in Mapcheck using Enhanced Dynamic Wedge (Enhanced Dynamic Wedge를 사용한 Mapcheck에서의 선량분포 평가)

  • Kang, Su-Man;Jang, Eun-Sun;Lee, Byung-Koo;Jung, Bong-Jae;Shin, Jung-Sub;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.343-349
    • /
    • 2012
  • Intensity Modulated Radiotherapy (IMRT) is increasing its use recently due to its benefits of minimizing the dose on surrounding normal organs and being able to target a high dose specifically to the tumor. The study aims to measure and evaluate the dose distribution according to its dynamic changes in Mapcheck. In order to verify the dose distribution by EDW angle($10^{\circ}$,$15^{\circ}$,$20^{\circ}$,$25^{\circ}$,$30^{\circ}$,$45^{\circ}$,$60^{\circ}$), field size (asymmetric field) and depth changes (1.5 cm, 5.0 cm) using IMRT in Clinac ix, a solid phantom was placed on the Mapcheck and 100MU was exposed by 6 MV, 10MV X-ray. Using a 6MV, 10MV energy, the percentage depth dose according to a dynamic changes at a maximum dose depth (1.5 cm) and at 5.0 cm depth showed the value difference of maximum 0.6%, less than 1%, which was calculated by a treatment program device considering the maximum dose depth at the center as 100%, the percentage depth dose was in the range between 2.4% and 7.2%. Also, the maximum value difference of a percentage depth dose was 4.1% in Y2-OUT direction, and 1.7% in Y1-IN direction. When treating a patient using a wedge, it is considered that using an enhanced dynamic wedge is effective to reduce the scattered dose which induces unnecessary dose to the surroundings. In particular, when treating a patient at clinic, a treatment must be performed considering that the wedge dose in a toe direction is higher than the dose in a heel direction.

Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward (방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가)

  • Kang, Seok-Jin;Lee, Doo-Hyeon;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.

Factors affecting radiation safety management of dental hygienist and anxiety of radiation exposure (치과위생사의 방사선 안전관리 실태 및 피폭 불안감에 영향을 미치는 요인)

  • Lee, Hye-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.432-439
    • /
    • 2018
  • The purpose of this study was to analyze the knowledge, attitudes, safety management behavior, and radiation anxiety of dental hygienists and to analyze affecting factors in order to improve the level of radiation safety management and reduce anxiety. The study period consisted of 280 dental hygienists working in Jeollabuk-do from September 10 to October 31, 2017 using the SPSS 12.0 program, frequency, descriptive statistics, and multiple regression analysis. The average knowledge level of radiation quality control was 8.07, and the correct answer rate was 75.3%. The attitude level was 96.1%, and the radiation safety management behavior was 4.11 for the photographer and 4.58 for the 'always wear a TLD (personal dosimeter) during radiography'. Patient radiation safety management behavior was 3.86, and the highest was '4.69' to confirm pregnancy of the woman before radiography. Radiation-covered lining was 3.86, and was the highest at 4.13 for 'I am concerned about fetal health when I am pregnant'. Factors affecting radiation exposure anxiety were lower radiation safety management behaviors, lower age, lower radiographic experience, higher educational background, higher monthly income, and higher job title (p<0.05). Based on the above results, dental hygienists had strong knowledge, attitudes, and safety management practices for radiation quality control. However, since anxiety related to radiation exposure was high, it is possible to improve radiation safety management level and reduce radiation exposure anxiety.

A Change in an Absorbed Dose of the Heart in General and Respiratory Control Radiation Treatment Plans (일반 및 호흡조절 방사선치료계획에서 심장의 흡수선량 변화)

  • Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.313-319
    • /
    • 2018
  • In radiation treatment, it is unavoidable to block the influence of scattered ray on a skin and prevent internal normal organs from being exposed to radiation. It is fair to say that radiation therapy aims to reduce an absorbed dose of normal tissues. In particular, in radiation therapy of left-sided breast cancer, the internal neighboring organs are normal breast tissues, the heart, and the lung. The side effects on the heart include cardioplegy and myocardial infarction. This study tried to observe changes in the volume and dose of the heart in general radiation therapy plan and respiratory control based radiation therapy plan for patients with left-sided breast cancer, and to find the heart's volume and dose generated by respiration. According to the 4D computer tomography (CT), a volume of the heart had $12.8{\pm}8.7cc$ on average, and its dose had $17.3{\pm}12.1cGy$ on average. The differences in the volume and dose may cause side effects in radiation treatment. Therefore, it is necessary to apply respiratory control technique to establish the radiation treatment plan based on an accurate position of the heart.

Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD) (전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가)

  • Lee, Joo-Ah;Back, Geum-Mun;Kim, Yeon-Soo;Son, Soon-Yong;Choi, Kwan-Woo;Yoo, Beong-Gyu;Jeong, Hoi-Woun;Jung, Jae-Hong;Kim, Ki-Won;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.125-134
    • /
    • 2014
  • This study is to provide basic information regarding photoneutron doses in terms of radiation treatment techniques and the number of portals in intensity-modulated radiation therapy (IMRT) by measuring the photoneutron doses. Subjects of experiment were 10 patients who were diagnosed with prostate cancer and have received radiation treatment for 5 months from September 2013 to January 2014 in the department of radiation oncology in S hospital located in Seoul. Thus, radiation treatment plans were created for 3-Dimensional Conformal Radiotherapy (3D-CRT), Volumetric-Modulated Arc Radiotherapy (VMAT), IMRT 5, 7, and 9 portals. The average difference of photoneutron dose was compared through descriptive statistics and variance analysis, and analyzed influence factors through correlation analysis and regression analysis. In summarized results, 3D-CRT showed the lowest average photoneutron dose, while IMRT caused the highest dose with statistically significance (p <.01). The photoneutron dose by number of portals of IMRT was $4.37{\pm}1.08mSv$ in average and statistically showed very significant difference among the number of portals (p <.01). Number of portals and photoneutron dose are shown that the correlation coefficient is 0.570, highly statistically significant positive correlation (p <.01). As a result of the linear regression analysis of number of portals and photoneutron dose, it showed that photoneutron dose significantly increased by 0.373 times in average as the number of portals increased by 1 stage. In conclusion, this study can be expected to be used as a quantitative basic data to select an appropriate IMRT plans regarding photoneutron dose in radiation treatment for prostate cancer.

Suggestion of A Practical Simple Calculation Method for Safe Transportation Time after Radioactive Iodine Treatment in Patients with Thyroid Cancer (갑상선암 환자에서 방사성옥소치료 후 안전하게 이동할 수 있는 시간을 계산하기 위한 실용적인 간편계산법 제안)

  • Park, Seok-Gun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3919-3925
    • /
    • 2015
  • When a patient with thyroid cancer is released from isolation after I-131 treatment and return to home using a vehicle, travel time should be controlled to reduce the amount of radiation to accompanying person. As the calculation of appropriate travel time is difficult, there is no patient-specific guideline until now. If we assume that there is no excretion and no physical decay during the relatively short travel time, calculation become quite simple; total radiation dose = dose rate ${\times}$ travel time. Results of this simple calculation and conventional calculation were compared using datum from 120 patients. Travel time calculated by simple method was 56% of conventional method in 0.3 m, 91% in 0.5 m and 96% in 1 m. Simple method was safe. It can be applied easily and also can be applied to the patients with hyperthyroidism treated by I-131.