• Title/Summary/Keyword: 환기 해석

Search Result 519, Processing Time 0.024 seconds

Numerical Simulation on Smoke Movement in Multi-Compartment Enclosure Fires under Pressurized Air Supply Conditions (급기가압 조건에서 복합 구획 공간 화재의 연기 거동에 대한 수치해석 연구)

  • Ko, Gwon Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the flow characteristics of fire smoke under pressurized air ventilation conditions by carrying out fire simulations on multi-compartment enclosure, including room, ancillary room and stair case. Fire simulations were conducted for the air-leakage test facility, which was constructed to measure the effective leakage area and aimed to improve the understandings of fire and smoke movement by analyzing the overall behaviors of fire smoke flow and pressure distributions of each compartment. The simulation results showed that the heat release rate of the fires was controlled sensitively by the amount of air supplied by the ventilation system. An analysis of the velocity distributions between the room and ancillary room showed that fire smoke could be leaked to the ancillary room through the upper layer of the door, even under pressurized air supply conditions. From these results, it was confirmed that the fire size and spatial characteristics should be considered for the design and application of a smoke control system by a pressurized air supply.

A Numerical Analysis on Forced Ventilation using Indoor Air Cleaner in an Apartment House (아파트주택에 있어서 실내공기청정기에 의한 환기의 수치해석)

  • 고재윤;김일겸;최병훈;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.217-223
    • /
    • 2001
  • There exist a number of approaches which can evaluate ventilation and indoor air quality. The measurement and analysis of indoor carbon dioxide concentrations can be useful for evaluating indoor air quality and ventilation. This paper describes a numerical analysis of carbon dioxide concentrations for evaluating indoor air quality and ventilation and the factors the need to be considered in their use. The conditions of this numerical analysis are tow types of positions and inlet velocities of ventilation system in a two-dimensional model of an apartment house. The simulation results could be used as a base data for further analysis for ventilation design of other industrial processes producing a proper ventilation system for a healthier and more comfortable environment in a building.

  • PDF

Unsteady Analysis of Indoor Radon in Apartment Buildings Considering Finishing Materials and Ventilation (마감재 및 환기를 고려한 공동주택 실내 라돈 농도의 비정상 해석)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.24-31
    • /
    • 2019
  • In this paper, we simulated a new apartment building by using radon emission test values from various building materials used as interior finishing materials. The simulations evaluated the radon concentration in the room according to the radon emissions and the ventilations for each type of finishing material (gypsum board, stone, tile and concrete). Overall concrete finish simulation case showed the highest concentration than the case using other materials due to the effect of wall area at the center of each room and the mean radon concentration at 1.5 m above the floor was slightly lower than the mean value at each center. In the case of the porch, pantry and bathroom, the radon concentration was high even when the same materials were used as in the other rooms.

Thermal Environment Analysis of a Room in Accordance with Ventilation Condition with Multi-Heat Sources (다수의 열원을 가지는 공간에서의 환기 조건에 따른 열환경 해석)

  • Kim, Jae-Jung;Son, Young-Gap;Chang, Seog-Weon;Ryu, Dong-Su
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.199-204
    • /
    • 2000
  • This paper reports a thermal environmental analysis of a room in accommodated with multi-heat sources according to ventilation condition. Two case modification have been investigated to obtain the lower temperature distribution in the room. The temperature distribution of the original room were found about $25{\sim}35^{\circ}C$. As a result, the use of, three ventilating fans and two electric fans are useful for room ventilation respectively, and using two electric fan is more recommendable in side of economical efficiency.

  • PDF

Numerical study for smoke behavior in case of train fires in railway tunnel with axial fan vents (강제환기 통풍구가 설치된 철도터널 열차화재에서 연기거동에 관한 수치해석적 연구)

  • Kim, Dong-Hyeon;Shin, Min-Ho;Moon, Jung-Joo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1998-2004
    • /
    • 2003
  • Numerical study were performed to analyze for fire safety in railway tunnel with forced ventilation vents. For the condition of train fires with heat release rate of 30 MW, unsteady three dimensional analysis were carried out to investigate the effects of smoke movements, the heat transfer and $CO_2$ concentrations and in double track tunnel with two vents. Among three operation modes of forced ventilations at two vents, the exhaust-exhaust mode of the vent represents the best performance for the evacuation of passengers to avoid the fire.

  • PDF

Numerical Analysis of the Kitchen Hood Ventilation System for Marine Environment (선박용 주방후드 환기시스템에 관한 수치해석)

  • Yi, Chung-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.96-101
    • /
    • 2015
  • This study regards distributions of flow in the ventilation system used in the kitchen hood in a ship. In this study, for describing the flow in the ventilation system, three-dimensional steady-state turbulence was assumed for the governing equation. When the plume was formed, three gases, CO, CO2, and HCL, in the flow field of the hood were considered as the plume, and it was assumed that the sum of concentrations of the gases was 100%. As a result, it could be confirmed that the plume was smoothly discharged when the flow rate of the supply was ten times lower than that of the exhaust.

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

Performance of A Fresh Water Generator Applied Plate Heat Exchangers and Flow in the Channel (판형열교환기를 적용한 청수제조장치의 성능 및 채널내 유동)

  • Jin, Z.H.;Ji, M.K.;Lee, K.S.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.5-10
    • /
    • 2009
  • 본 연구에서는 판형열교환기를 적용한 청수제조장치의 성능에 대하여 연구를 수행하였다. 판형열교환기는 자체의 높은 열전달 성능과 컴펙트한 장점으로 하여 산업에서 점차 널리 사용되고 있다. 또한 사용, 유지보수가 다른 종류의 열교환기에 비하여 편리하여 유연성 있게 사용할 수 있다. 본 실험에서는 세브론 각도가 60도인 전열판을 사용하였으며 이젝터의 작동으로 열교환기를 장착하고 있는 탱크내부에 진공압력을 유지함으로서 내부유체가 $51^{\circ}C{\sim}57^{\circ}C$에서 증발현상이 발생하는 것을 확인하였다. 또한 수치해석적 방법을 통하여 복잡하며 좁은 세브론전열판으로 이루어진 유로내의 유동특성을 파악할 수 있었다.

  • PDF

Numerical Analysis on the Development of a Ventilation Opening Louver for Marine (선박용 환기구 루버 개발을 위한 수치해석)

  • Yi, Chung-Seob;Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.30-35
    • /
    • 2017
  • This study is about distributions of flow in a ventilation system used in a louver for marine. In this study, to describe the flow in the ventilation opening louver, 3-dimensional steady-state turbulence was assumed to govern the equation. The flow field with pressure distribution according to the inlet velocity at the louver types is also compared. Flow analysis was performed for the louver numerical analysis on two types. The numerical analysis results in the louver blade indicated increased flow resistance at type-1.

The Characteristics of Ventilation in Railway Tunnel (철도터널의 환기특성에 관한 연구)

  • Yoo, Ji-oh;Shin, Hyun-Jun;Lee, Ho-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.2
    • /
    • pp.22-31
    • /
    • 2000
  • This study aimed at investigating the influence of tunnel length and area, drag coefficient, train velocity on the characteristics of ventilation in railway tunnel. The modified Subway Environment Simulation(SES) computer program has been used to calculate the flow velocity and longitudinal emission concentration with various condition. According to a series of numerical simulation, the influence of various parameter on maximum air flow velocity, purging length and emission concentration are estimated.

  • PDF